The Remote data logger with display is designed for applications where carbon dioxide levels need to be measured in a remote location (100 feet or more away), while being displayed locally on a data-logging head unit. It includes a CO2 level transmitter tethered to a head unit that displays the current CO2 reading. The head unit includes built-in memory, so it can be detached and connected to a computer to download the logged data. 

In addition to data-logging, the remote head unit includes a relay that can actively control ventilation or CO2 generation systems, and a built-in buzzer to warn when CO2 levels exceed a programmed limit.

Free Easy-to-use Software for Download

This device is compatible with CO2 Meter's fully-featured data acquisition system (DAS) software. This software has been built from the ground up to allow for easy configuration, data collection, and calibration of your data logger. Available completely free of charge on our website, this software allows you to download logs, analyze, and export your data in report form, and as a CSV file for importation into industry-standard data logging packages.

Download Latest Software Here

Typical Applications

  • Poultry Production
  • Livestock / Poultry Transport
  • Incubation Applications
  • Hydroponics / Forced Ventilation 
  • Transportation of MAP (modified atmosphere packaging) Produce
  • Remote Monitoring of Livestock
When connected to the remote transmitting sensor the head unit automatically begins data collection upon power-up. 

Specifications

  • 12-24VDC Input
  • 240V 10A Relay with NC and NO contacts
  • Repeatability: ± 20 ppm ± 1 % of measured value
  • Accuracy: ± 30 ppm ± 5 % of measured value
  • Sensor Life Expectancy: > 15 years
  • Maintenance Interval: no maintenance required
  • Self-Diagnostics: complete function check of the sensor module
  • Warm-up Time: < 1 min. (@ full specs < 15 min)

Warranty
  • 90 Days