PM2008M-M Cubic Particulate Matter Sensors

PM2008M-M Cubic Particulate Matter Sensors
Normaler Preis €35,98

POs or wholesale quantity discounts click here

Cubic's PM1.0, PM2.5, and PM10 combined Particulate Matter Sensors deliver fast, accurate and stable performance at an incredibly low price. They are designed to be used stand-alone or as the foundation of an OEM indoor air quality PM detector.

Features

  • Advanced laser scattering technology
  • Real-time output PM1.0, PM2.5, PM10 in μg/m³
  • Small, compact structure
  • All-metal shielding for strong anti-interference
  • High accuracy, high sensitivity and quick response
  • Industry-standard UART, I²C outputs
  • Four types of measuring modes: single/continuous/timing/dynamic
  • RoHS and Reach compliant

Models

  • PM2008M-M: High Accuracy PM Sensor Module - UART, I2C, PWM, with inlet and outlet ports on the same side. Better accuracy at very low PM levels.
  • PM2012SE-A: Compact PM Sensor Module - UART, I2C. Opposite side ports.

PM2008M-M Specifications

  • Operating principle: Laser scattering
  • Measured particle range: 0.3μm~10μm
  • Measurement range: 0~5,000μg/m³
  • Resolution: 1μg/m³
  • Accuracy: (GRIMM, 25±2℃, 50 ±10%RH)
  • PM2.5/PM1.0:: 0~35μg/m³, ±5μg/m³, 35~500μg/m³, ±15% reading
  • PM10: 0~100μg/m³, ±25μg/m³, 101~500μg/m³, ±25% reading
  • Response time: 1 sec
  • Time to first reading: ≤ 8 seconds
  • Power supply: DC 5V±0.1V, ripple wave<50mV
  • Working current: ≤100mA
  • Standby current: ≤200μA
  • Dimensions: W48*H40*D12 mm
  • Digital output 1: UART: 3.3VDC, I2C 3.3-5VDC
  • Digital output 2: PWM (customized)
  • MTTF: 110,000 hours (continuous turn on)
  • Working condition: -10°C ~ 60°C, 0-95%RH (non-condensing)
  • Storage condition: -40°C ~ 80°C, 0-95%RH (non-condensing)
  • Weight: 6g

CU-PM2012SE-A Specifications

  • Operating principle: Laser scattering
  • Measured particle range: 0.3μm~10μm
  • Measurement range: 0~5,000μg/m³
  • Resolution: 1μg/m³
  • Accuracy: (GRIMM, 25±2℃, 50 ±10%RH)
  • PM2.5/PM1.0:: 0~100μg/m³, ±10μg/m³, 101~500μg/m³, ±10% reading
  • PM10: 0~100μg/m³, ±25μg/m³, 101~500μg/m³, ±25% reading
  • Response time: 1 sec
  • Time to first reading: ≤ 8 seconds
  • Power supply: DC 5V±0.1V, ripple wave<50mV
  • Working current: ≤100mA
  • Standby current: ≤200μA
  • Dimensions: W38*H35*D12 mm
  • Digital output: UART/I2C: 3.3VDC/5VDC(Level)
  • MTTF: 110,000 hours (continuous turn on)
  • Working condition: -10°C ~ 60°C, 0-95%RH (non-condensing)
  • Storage condition: -40°C ~ 80°C, 0-95%RH (non-condensing)
  • Weight: 6g

Warranty

  • 90 days - See CO2Meter Terms and Conditions.

Cubic Software

Software supplied by the manufacturer lets you test and read single sensors using UART or multiple sensors in series using I2C.

Particle sensor software Particle Sensor Software (zip)

A cable to connect the sensors is not included. We suggest:

CU-PM2008M-M - LATTECH 5 PIN JST Cable

CU-PM2012SE-A - Harwin M50-3120545 On-board Connector

  • Data Sheets

  • Manuals

  • Technical Documents

  • Videos

  • Additional Resources

  • Case Studies

Customer Reviews

Be the first to write a review
0%
(0)
0%
(0)
0%
(0)
0%
(0)
0%
(0)

"Easy to install, easy to set up, and easy calibration - just what I was looking for."

- Phillip Farrar
Water Plant Superintendent

Read More Reviews...