{"product_id":"co2-o2-nh3-fixed-gas-detection-system-laboratory","title":"CO2, O2 and NH3 Fixed Gas Safety System for Laboratories \u0026 Pharma | Multi-Gas Monitoring with Alarms","description":"\u003cp\u003e\u003cstrong\u003e🚨 Protect Laboratories \u0026amp; Pharma Facilities from CO2, O2 and Ammonia Hazards\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eMSC2-CO2-O2-NH3 System: CO2, O2, and NH3 Fixed Gas Detection System is an advanced multi-gas safety solution designed for continuous monitoring of carbon dioxide, oxygen and ammonia (NH3) in laboratory, pharmaceutical and research environments.\u003c\/p\u003e\n\u003cp data-start=\"536\" data-end=\"876\"\u003eLaboratories and pharma facilities often face multiple gas hazards simultaneously from CO2 buildup and oxygen displacement to toxic ammonia exposure.\u003c\/p\u003e\n\u003cp data-start=\"878\" data-end=\"1094\"\u003eBuilt on the MSC2 multi-gas safety platform, this system uses remote sensors to detect hazards at the source: triggering alarms, activating ventilation, and integrating with BMS systems for immediate response.\u003c\/p\u003e\n\u003ch2\u003eFeatures\u003c\/h2\u003e\n\u003cp\u003e•    Triple Gas Monitoring (CO2 + O2 + NH3)\u003cbr\u003e•    Remote Sensor Detection\u003cbr\u003e•    Designed for Labs \u0026amp; Pharma\u003cbr\u003e•    Audio\/Visual Alarms + Relays\u003cbr\u003e•    Multi-Gas Expandable Platform\u003cbr\u003e•    BMS \u0026amp; PLC Integration Ready\u003cbr\u003e•    Custom Configurations\u003cbr\u003e•    Flexible Power Options\u003cbr\u003e•    IP65 Rugged Enclosure\u003c\/p\u003e\n\u003ch2 data-end=\"1875\" data-start=\"1853\" data-section-id=\"101sl6h\"\u003e📦 What’s Included?\u003c\/h2\u003e\n\u003cul data-end=\"2265\" data-start=\"1877\"\u003e\n\u003cli data-end=\"1936\" data-start=\"1877\" data-section-id=\"438bkx\"\u003eMSC2 Fixed Gas Detection Controller (Main Display Unit)\u003c\/li\u003e\n\u003cli data-end=\"1966\" data-start=\"1937\" data-section-id=\"c0ypip\"\u003e(3) Remote Gas Sensors (CO2, O2, and NH3)\u003c\/li\u003e\n\u003cli data-end=\"2088\" data-start=\"2045\" data-section-id=\"zyx6sy\"\u003e(2) Audible \u0026amp; Visual Horn\/Strobe Alarms\u003c\/li\u003e\n\u003cli data-end=\"2132\" data-start=\"2089\" data-section-id=\"io3u1f\"\u003ePre-Configured Alarm Relays\u003c\/li\u003e\n\u003cli data-end=\"2186\" data-start=\"2133\" data-section-id=\"1hwy61f\"\u003ePower Supply Compatibility (100–240 VAC \/ 24 VDC)\u003c\/li\u003e\n\u003cli data-end=\"2229\" data-start=\"2187\" data-section-id=\"1kfu224\"\u003eWall-Mount Hardware \u0026amp; Installation Kit\u003c\/li\u003e\n\u003cli data-end=\"2265\" data-start=\"2230\" data-section-id=\"12t0ca\"\u003eUser Manual \u0026amp; Quick Start Guide\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv class=\"specifications\"\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cb\u003eGas Types: \u003c\/b\u003eCO2 (Carbon Dioxide), O2 (Oxygen), NH3 (Ammonia)\u003c\/li\u003e\n\u003cli data-end=\"2427\" data-start=\"2359\" data-section-id=\"ebfih5\"\u003e\n\u003cstrong data-end=\"2387\" data-start=\"2361\"\u003eCO2 Measurement Range:\u003c\/strong\u003e 0–5,000 ppm (custom ranges available)\u003c\/li\u003e\n\u003cli data-end=\"2467\" data-start=\"2428\" data-section-id=\"yl5m4e\"\u003e\n\u003cstrong data-end=\"2455\" data-start=\"2430\"\u003eO2 Measurement Range:\u003c\/strong\u003e 0–25% Vol\u003c\/li\u003e\n\u003cli data-end=\"2537\" data-start=\"2468\" data-section-id=\"r324fe\"\u003e\n\u003cstrong data-end=\"2496\" data-start=\"2470\"\u003eNH3 Measurement Range:\u003c\/strong\u003e 0–100 ppm (expandable up to 5,000 ppm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHousing Type C\/E: \u003c\/strong\u003ePolycarbonate\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInstallation: \u003c\/strong\u003eWall Mounted\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eKnockouts for Cable Entry: \u003c\/strong\u003eStandard 6x M20\/25\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIngress Protection: \u003c\/strong\u003eIP65\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTemperature Range: \u003c\/strong\u003e-13°F to 140°F (-25°C to 60°C)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHumidity Range: \u003c\/strong\u003e15-95% RH non-condensing\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Supply:\u003c\/strong\u003e 100-240 VAC or 24VDC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Consumption: \u003c\/strong\u003e24 V DC | Max. 60 mA (1.5 VA), w\/ sensor, w\/o WAO\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAlarm Relay (3): \u003c\/strong\u003e5 A Dry Contact Configurable\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTransistor Output (2):\u003c\/strong\u003e 24 V DC\/0.1 A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAnalog Input (2\/3): \u003c\/strong\u003e4-20mA compatible\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAnalog Output Signal (1): \u003c\/strong\u003eFault \u0026amp; range monitoring included\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eController Dimensions:\u003c\/strong\u003e 5.12 x 5.12 x 2.95 in. (130 x 130 x 75 mm)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eController Weight:\u003c\/strong\u003e 1.32 lbs. (0.6 kg)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"specifications\"\u003e\n\u003ch3\u003eWarranty\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e1 year - See \u003cstrong\u003e\u003ca href=\"https:\/\/www.co2meter.com\/pages\/terms-conditions\" title=\"CO2Meter Terms and Conditions\"\u003eCO2Meter Terms and Conditions.\u003c\/a\u003e\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"documents\"\u003e\n\u003cdiv class=\"data-sheets\"\u003e\n\u003ch2\u003eDocuments\u003c\/h2\u003e\n\u003cp style=\"text-align: left;\"\u003e\u003ca title=\"Gaslab Fixed Gas Detector Datasheet\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/DS-MSC2-CO2-O2-NH3-SYSTEM_-_Carbon_Dioxide_CO2_Oxygen_O2_Ammonia_NH3_Fixed_Gas_Safety_Detection_System.pdf\" target=\"_blank\"\u003e\u003cimg alt=\"Gaslab Fixed Gas Detector DataSheet\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/CO2METER_PDF.png?1093\"\u003e\u003c\/a\u003e\u003ca rel=\"noopener\" title=\"Gaslab Fixed Gas Detector Datasheet\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/DS-MSC2-CO2-O2-NH3-SYSTEM_-_Carbon_Dioxide_CO2_Oxygen_O2_Ammonia_NH3_Fixed_Gas_Safety_Detection_System.pdf\" target=\"_blank\"\u003e\u003cstrong\u003e\u003cspan style=\"color: red;\"\u003eData Sheet (pdf) - MSC2 Detector\u003c\/span\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cimg alt=\"Gaslab Fixed Ammonia Gas Detector\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/CO2METER_PDF.png?1093\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/MAN_GA_MSC2_MSB2_CO2Meter-compressed_1.pdf?v=1755194606\"\u003e\u003cstrong\u003e\u003cspan style=\"color: red;\"\u003eManual\u003c\/span\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/MAN_GA_MSC2_MSB2_CO2Meter-compressed_1.pdf?v=1755194606\"\u003e\u003c\/a\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"CO2Meter","offers":[{"title":"MSC2-CO2-O2-NH3-System: CO2, O2, \u0026 NH3 Fixed Gas Detection System for Laboratories \u0026 Pharma","offer_id":43987877265606,"sku":"MSC2-CO2-O2-NH3-System","price":4699.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/MSC2-Fixed-CO2-O2-NH3-System-3_Remote-2-Horn-Strobes.jpg?v=1775752398","url":"https:\/\/www.co2meter.com\/es-mx\/products\/co2-o2-nh3-fixed-gas-detection-system-laboratory","provider":"CO2 Meter","version":"1.0","type":"link"}