{"title":"Suppliers","description":"","products":[{"product_id":"k-30-co2-sensor-module","title":"030-8-0006 K30 10,000 ppm CO2 Sensor","description":"\u003cp\u003eThe \u003cspan style=\"color: rgb(17, 94, 103);\"\u003e\u003cstrong\u003eK30 10,000ppm CO2 Sensor Module (030-8-0006)\u003c\/strong\u003e\u003c\/span\u003e is an industry favorite known for its low-cost, accuracy, long life and low maintenance. It is used in hundreds of HVAC and IAQ products and applications. In addition, this CO2 sensor is easy to program with several output options to meet virtually any OEM project specifications.\u003c\/p\u003e\n\u003ch2\u003eFeatures\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eIdeal for residential, commercial, HVAC or IAQ applications\u003c\/li\u003e\n\u003cli\u003eSimple to install, pre-calibrated and ready-to-use\u003c\/li\u003e\n\u003cli\u003e2 analogue outputs, 2 digital outputs\u003c\/li\u003e\n\u003cli\u003eProven reliability, low cost, maintenance free\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eModels\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eK30 CO2 Sensor\u003c\/strong\u003e (030-8-0006) - for integration into high-volume OEM products.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eK30 CO2 Sensor with Custom Outputs\u003c\/strong\u003e (030-8-0006-C) - Customize analog or digital outputs for your application. After ordering, email or fax the \u003ca title=\"Custom Outputs E-Mail Form\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/SE-0018-Configuration-Options-Form-2022.pdf\"\u003eCustom Outputs PDF form\u003c\/a\u003e and we will pre-configure your sensor’s settings. If the form is not received, your sensor will be delivered with default settings.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eK30 CO2 Sensor Development Kit\u003c\/strong\u003e (CM-0024) - Easy to use, simply plug the sensor module into your PC via USB. Use our free \u003ca title=\"Gaslab Software\" href=\"https:\/\/www.co2meter.com\/pages\/downloads\"\u003eGasLab® software\u003c\/a\u003e to measure and graph carbon dioxide in real time or for data logging.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSensor Development Kit\u003c\/strong\u003e (CM-200) - Easy to use, simply plug the sensor into the PCB and plug it into your PC via USB. Use our free \u003ca href=\"\/en-ca\/pages\/downloads\" title=\"Gaslab software\"\u003eGasLab® software\u003c\/a\u003e to measure and graph carbon dioxide or use our \u003ca href=\"https:\/\/github.com\/co2meter-org\/ExampleCode\" title=\"Source code on Github\" rel=\"noopener\" target=\"_blank\"\u003elibrary of source code on Github\u003c\/a\u003e to build your own application or for OEM batch testing\/configuration. Order sensors on this page, then \u003ca href=\"https:\/\/www.co2meter.com\/products\/gas-sensor-development-kit\" title=\"Gas Sensor Development Kit\"\u003eorder the Devkit here\u003c\/a\u003e.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan style=\"color: #286adc;\"\u003e\u003cstrong\u003eWe recommend that all first-time users purchase either the CM-0024 or CM-200 Development Kit for fastest and easiest results.\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cdiv class=\"specifications\"\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCO2 Measurement:\u003c\/strong\u003e non-dispersive infrared (NDIR)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMeasurement Range:\u003c\/strong\u003e 0 – 10,000 ppm (0-5,000 ppm within specifications)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRate of Measurement:\u003c\/strong\u003e every 2 seconds\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAutomatic Background Calibration (ABC):\u003c\/strong\u003e enabled unless specified\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eResponse Time Diffusion:\u003c\/strong\u003e 20 seconds\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eResponse Time Sample Draw:\u003c\/strong\u003e 2 seconds @ .5 l\/min tube gas flow\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWarm-up Time:\u003c\/strong\u003e \u0026lt; 1 min. (@ full specs \u0026lt; 15 min)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutputs:\u003c\/strong\u003e 2 analog, 2 digital\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProgrammable Range:\u003c\/strong\u003e 0-10,000 ppm (custom configuration required)\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRepeatability:\u003c\/strong\u003e ± 20 ppm ± 1 % of measured value within specifications\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAccuracy:\u003c\/strong\u003e ± 30 ppm ± 3 % of measured value within specifications\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaintenance Interval:\u003c\/strong\u003e no maintenance required\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSelf-Diagnostics:\u003c\/strong\u003e complete function check at startup\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDimensions:\u003c\/strong\u003e 51 x 58 x 14 mm (Length x Width x approximate Height)\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSensor Life Expectancy:\u003c\/strong\u003e \u0026gt; 15 years\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eConforms with Standards\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eEmission: EN61000-6-3:2001\u003c\/li\u003e\n\u003cli\u003eImmunity: EN61000-6-2:2001\u003c\/li\u003e\n\u003cli\u003eCompliant with ANSI\/ASHRAE Standard 62.1-2022\u003c\/li\u003e\n\u003cli\u003eCompliant with RESET grad B\u003c\/li\u003e\n\u003cli\u003eCompliant with WELL Building Standard® (WELL v2™)\u003c\/li\u003e\n\u003cli\u003eRoHS directive 2002\/95\/EG\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eElectrical \/ Mechanical\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003ePower Input: 5.5-14 VDC, stabilized to within 10% (external protection circuits required)\u003c\/li\u003e\n\u003cli\u003eCurrent Consumption: 40 mA average\u003c\/li\u003e\n\u003cli\u003eSampling Method: diffusion (tube cap optional)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eWarranty\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e90 days - See\u003ca title=\"Terms and Conditions\" href=\"https:\/\/www.co2meter.com\/pages\/terms-conditions\"\u003e CO2Meter Terms and Conditions.\u003c\/a\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"documents\"\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/rmtplusstoragesenseair.blob.core.windows.net\/docs\/publicerat\/PSH0131.pdf\"\u003e\u003cimg alt=\"Datasheet\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/CO2METER_PDF.png?1094\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/rmtplusstoragesenseair.blob.core.windows.net\/docs\/publicerat\/PSH0131.pdf\"\u003e\u003cstrong\u003e\u003cspan style=\"color: red;\"\u003e Data Sheet (pdf)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/Drawing_K30_K33_Revised_2023.pdf?v=1692893892\"\u003e\u003cimg alt=\"CO2 sensor drawing\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/CO2METER_PDF.png?1094\"\u003e\u003cstrong\u003e\u003cspan style=\"color: red;\"\u003e Dimensional Drawings Tube Cap Adapter (pdf)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/SenseairISO.pdf?v=1679586340\"\u003e\u003cimg alt=\"Senseair ISO Certification\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/CO2METER_PDF.png?1093\"\u003e\u003cstrong\u003e\u003cspan style=\"color: red;\"\u003e Senseair ISO Certification (pdf)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003ch3\u003eCustom Output\u003c\/h3\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/Output_Configuration_in_CO2_Engine_K30_Revised8.pdf?v=1653007118\"\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/CO2METER_PDF.png?1094\"\u003e\u003cstrong\u003e\u003cspan style=\"color: red;\"\u003e Custom Output Configuration Options (pdf)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca title=\"SE-0018 Configuration Options\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/SE-0018-Configuration-Options-Form-2022.pdf\"\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/CO2METER_PDF.png?1094\"\u003e\u003cstrong\u003e\u003cspan style=\"color: red;\"\u003e Custom Outputs E-Mail Form (pdf)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003ch4\u003eInstructions:\u003c\/h4\u003e\n\u003cp\u003e1. Download the PDF form above and save to your hard drive.\u003cbr\u003e2. Open the PDF and enter your values in the fields. Save.\u003cbr\u003e3. Please specify in the form if you wish the ABC\u003cbr\u003e(Automatic Background Calibration) on or off.\u003cbr\u003e4. Please specify in the form if you want to program the\u003cbr\u003esensor for communication with RS-485.\u003cbr\u003e5. Email as an attachment to sales@co2meter.com and reference your order code.\u003cbr\u003e6. Select \u003cstrong\u003eK30 1% Custom\u003c\/strong\u003e (030-8-0006-C) and complete your order.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"manuals\"\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/rmtplusstoragesenseair.blob.core.windows.net\/docs\/publicerat\/PSP110.pdf\"\u003e\u003cimg alt=\"Manual\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/CO2METER_PDF.png?1094\"\u003e\u003cstrong\u003e\u003cspan style=\"color: red;\"\u003e K30 1% Manual (pdf)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/DS-SenseAir-K30-CO2-Sensor-Revised-2023.pdf?v=1692893893\"\u003e\u003cimg alt=\"Datasheet\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/CO2METER_PDF.png?1094\"\u003e\u003cstrong\u003e\u003cspan style=\"color: red;\"\u003e K30 Terminal Descriptions (pdf)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/AN145-sensor-development-kit-quick-start-guide.pdf?v=1650749355\"\u003e\u003cimg alt=\"Quick Start Guide\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/CO2METER_PDF.png?1094\"\u003e\u003cstrong\u003e\u003cspan style=\"color: red;\"\u003e Devkit Quick Start Guide (pdf)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/AN_SE_0020_Sensor_Calibration_Procedure_2023.pdf?v=1692893892\"\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/CO2METER_PDF.png?1094\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/AN_SE_0020_Sensor_Calibration_Procedure_2023.pdf?v=1706541759\"\u003e\u003cstrong\u003e\u003cspan style=\"color: red;\"\u003e Sensor Calibration Procedure (pdf)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"technical-documents\"\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/rmtplusstoragesenseair.blob.core.windows.net\/docs\/Dev\/publicerat\/TDE2336.pdf\"\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/CO2METER_PDF.png?1094\"\u003e\u003cstrong\u003e\u003cspan style=\"color: red;\"\u003e Modbus Communication (pdf)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/rmtplusstoragesenseair.blob.core.windows.net\/docs\/Dev\/publicerat\/TDE4700.pdf\"\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/CO2METER_PDF.png?1094\"\u003e\u003cstrong\u003e\u003cspan style=\"color: red;\"\u003e I2C Communication (pdf)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/SenseAirCommGuide.zip?v=1638914112\"\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/assets\/zip.gif\"\u003e\u003cstrong\u003e\u003cspan style=\"color: red;\"\u003e I2C \u0026amp; Modbus Communication Example Code (zip)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/AN141-Labview-examples.zip?v=1647477681\"\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/assets\/zip.gif\"\u003e\u003cstrong\u003e\u003cspan style=\"color: red;\"\u003e Labview Examples for SenseAir K-30 (zip)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/AN_144_SE_0018_Revised8_CO2Meter.pdf?v=1710164404\"\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/CO2METER_PDF.png?1094\"\u003e\u003cstrong\u003e\u003cspan style=\"color: red;\"\u003e Web Application Using PHP and K30 DevKit (pdf)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/AN137-K30-sensor-raspberry-pi-Revised8.pdf?v=1653006660\"\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/assets\/zip.gif\"\u003e\u003cstrong\u003e\u003cspan style=\"color: red;\"\u003e Raspberry Pi UART Instructions (pdf)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/AN137-K30-sensor-raspberry-pi.zip?v=1653006700\"\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/assets\/zip.gif\"\u003e\u003cstrong\u003e\u003cspan style=\"color: red;\"\u003e Raspberry Pi UART Sample Code (zip)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/AN126-K3x-sensor-arduino-uart_2023.pdf?v=1692893893\"\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/CO2METER_PDF.png?1094\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/AN126-K3x-sensor-arduino-uart_2023.pdf?v=1715030056\"\u003e\u003cstrong\u003e\u003cspan style=\"color: red;\"\u003e Arduino UART Instructions (pdf)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/AN126-K3x-sensor-arduino-uart.zip?v=1653006884\"\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/assets\/zip.gif\"\u003e\u003cstrong\u003e\u003cspan style=\"color: red;\"\u003e Arduino UART Sample Code (zip)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/AN102-K30-Sensor-Arduino-I2C-2023.pdf?\"\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/CO2METER_PDF.png?1094\"\u003e\u003cstrong\u003e\u003cspan style=\"color: red;\"\u003e Arduino I2C Instructions (pdf)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/AN102-K30-Sensor-Arduino-I2C.zip?v=1653007039\"\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/assets\/zip.gif\"\u003e\u003cstrong\u003e\u003cspan style=\"color: red;\"\u003e Arduino I2C Sample Code (zip)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/AN_144_SE_0018_Revised8_CO2Meter.pdf?v=1710164404\"\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/CO2METER_PDF.png?1094\"\u003e\u003cstrong\u003e\u003cspan style=\"color: red;\"\u003e Troubleshooting Arduino or Raspberry Pi (pdf)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"case-studies\"\u003e\n\u003cp\u003e\u003ca title=\"CO2 Sensors compared\" href=\"\/en-ca\/blogs\/news\/6926946-senseair-k30-vaisala-cmm222c-elt-s100-kcd-an100-and-ge-sensing-t6615-sensor-comparison\"\u003eSenseAir K30, Vaisala CMM222C, ELT S100, KCD AN100 and GE Sensing T6615 Sensor Comparison\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca title=\"CO2 Monitoring during composting article\" href=\"\/en-ca\/blogs\/news\/co2-monitoring-and-composting-applications\"\u003eMonitoring CO2 Levels Critical for Compost Success\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca title=\"Haney test uses CO2 sensor\" href=\"\/en-ca\/blogs\/news\/haney-test-co2-sensor-soil-health\"\u003eHaney Test Uses CO2 Sensor to Measure Soil Health\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca title=\"K-30 CO2 sensor school science fair project\" href=\"\/en-ca\/blogs\/news\/15302513-school-science-fair-project-uses-co2meter-sensors\"\u003eSchool Science Fair Projects Using SenseAir CO2 Sensors\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca title=\"K30 sensor and Arduino Uno\" href=\"\/en-ca\/blogs\/news\/student-science-fair-project-co2-sensor-arduino\"\u003eStudent project combines CO2 sensor, Arduino Uno\u003c\/a\u003e\u003ca title=\"K30 sensor and CRDS CO2 measurement comparison\" href=\"\/en-ca\/blogs\/news\/senseair-co2-sensor-competes-with-crds-unit-that-costs-thousands-more\"\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"software\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv class=\"accessories\"\u003e\n\u003ch3\u003eAccessories\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003ca title=\"CO2Meter Gas Sensor Development Kit\" href=\"https:\/\/www.co2meter.com\/products\/gas-sensor-development-kit\"\u003e\u003cstrong\u003eGas Sensor Development Kit \u003c\/strong\u003e\u003c\/a\u003e- CM-0024 designed to provide customers with an easy drop-in solution. Includes our free \u003ca href=\"https:\/\/www.co2meter.com\/pages\/downloads\" title=\"Gaslab data logging software\"\u003eGaslab data logging software\u003c\/a\u003e. Sensor sold separately.\u003c\/li\u003e\n\u003cli\u003e\n\u003ca title=\"CO2Meter Sensor Tube Cap Adapter\" href=\"\/en-ca\/products\/sensor-flow-through-director\"\u003e\u003cstrong\u003eTube Cap Adapter\u003c\/strong\u003e\u003c\/a\u003e changes the sensor from reading CO2 in the air to a sample draw sensor. Use with a pump, tubing and filters to read CO2 levels in enclosed containers.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003ca href=\"\/en-ca\/products\/gas-sensor-micro-pump\"\u003eSample Draw Pump Kit\u003c\/a\u003e\u003c\/strong\u003e includes all the components you need with a sample draw sensor to create a closed CO2 measurement system.\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"\/en-ca\/products\/probe-enclosure-development-kit\" title=\"View the Probe Enclosure for Development Kits\"\u003e\u003cstrong\u003eProbe Enclosure\u003c\/strong\u003e\u003c\/a\u003e. Includes hydrophobic filters, protects the sensor when used in hostile environments.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e","brand":"Senseair","offers":[{"title":"030-8-0006 - K30 10,000ppm CO2 Sensor Module","offer_id":42786804793542,"sku":"030-8-0006","price":85.8,"currency_code":"USD","in_stock":true},{"title":"030-8-0006-C - K30 10,000ppm CO2 Custom Sensor (include form)","offer_id":19366342,"sku":"030-8-0006-C","price":142.0,"currency_code":"USD","in_stock":true},{"title":"CM-0024 - K30 Development kit","offer_id":43943390445766,"sku":"CM-0024","price":252.0,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/030-8-0006_K30_10_000ppm_CO2_Sensor_d86a0e88-d394-4f56-a14a-fa4dbd9513d3.jpg?v=1753284223"},{"product_id":"k33-environmental-logger-co2-sensor","title":"033-8-0007 K33 ELG 10,000ppm CO2 + RH\/T Data Logging Sensor","description":"\u003cp\u003eThe \u003cspan style=\"color: #115e67;\"\u003e\u003cstrong\u003e033-8-0007 \u003c\/strong\u003e\u003c\/span\u003e\u003cstrong\u003e\u003cspan style=\"color: #115e67;\"\u003eK33 ELG CO2 Data Logging Sensor\u003c\/span\u003e \u003c\/strong\u003e\u003cem\u003e(formerly known as SE-0020)\u003c\/em\u003e is designed to monitor up to 1% CO2, Temperature and %RH. This sensor is ideal for low power applications where keeping power consumption at minimum is vital.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMeasures up to 10,000ppm CO2\u003c\/li\u003e\n\u003cli\u003eBuilt-in Memory for Data Logging\u003c\/li\u003e\n\u003cli\u003eMultiple Industry standard I\/O options\u003c\/li\u003e\n\u003cli\u003eIndividually calibrated for high performance\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eModels\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e033-8-0007:  K33 ELG 1% CO2 Sensor Only\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e- for integration into high-volume OEM products. Contact us directly for wholesale pricing on large quantities of this sensor.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCM-0026: K33 ELG 1% CO2 Sensor Development Kit\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e- Easy to use, simply plug the sensor module into your PC via USB.\u003cspan\u003e \u003c\/span\u003e\u003cspan\u003eUse it for evaluation, rapid application development or for experiments. The Devkit includes a K33 ELG sensor with pre-soldered connectors that provide power and connectivity. UART to USB Bridge cable, universal power supply and AA battery pack included. \u003c\/span\u003eUses our free GasLab® software to measure and graph carbon dioxide, to configure the sensor or for data logging.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv class=\"specifications\"\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCO2 Measurement:\u003c\/strong\u003e Non-dispersive infrared (NDIR)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMeasurement Range:\u003c\/strong\u003e 0 – 10,000 ppm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRate of Measurement:\u003c\/strong\u003e every 20 seconds\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eResponse time:\u003c\/strong\u003e 30 seconds\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWarm up time:\u003c\/strong\u003e\u003cspan data-mce-fragment=\"1\"\u003e \u0026lt; 1 min. (@ full specs \u0026lt; 15 min)\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAccuracy:\u003c\/strong\u003e ± 30ppm ± 3% of measured value\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTemperature Range:\u003c\/strong\u003e -40 to 60C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTemperature Accuracy:\u003c\/strong\u003e ± 0.4C at 25C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRelative Humidity Range:\u003c\/strong\u003e 0-100% RH non-condensing\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRelative Humidity Accuracy:\u003c\/strong\u003e ± 3% RH\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMeasurement Method:\u003c\/strong\u003e diffusion\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAvailable Output:\u003c\/strong\u003e Analog\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCommunication options:\u003c\/strong\u003e UART and I2C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eData logging:\u003c\/strong\u003e 30 seconds to 18 hours sample interval for CO2, RH \u0026amp; T\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOptional:\u003c\/strong\u003e Support for real-time measurement with software\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMemory:\u003c\/strong\u003e 5,400 log entries maximum, includes timestamp, co2, temp, RH. 1 additional analog input to the log available\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaintenance Interval\u003c\/strong\u003e: no maintenance required\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCurrent Firmware\u003c\/strong\u003e: 510-00103 rev 0.04 \u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDimensions\u003c\/strong\u003e: 2.0 × 2.25 × 0.5 inches\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSensor Life Expectancy:\u003c\/strong\u003e \u0026gt;15 years\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eElectrical \/ Mechanical\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Input:\u003c\/strong\u003e 6-14 VDC max rating, stabilized to within 10%\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMax Current:\u003c\/strong\u003e 250 mA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCurrent Consumption:\u003c\/strong\u003e 40 mA average\u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eDevelopment Kit\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e6’ (1.8m)\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"caps\"\u003eUSB\u003c\/span\u003e -UART bridge cable (non-standard)\u003c\/li\u003e\n\u003cli\u003e6VDC universal wall power supply with connector for sensor 120\/240 VAC 50\/60 Hz\u003c\/li\u003e\n\u003cli\u003e4x AA battery pack w\/ connector for sensor \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eWarranty\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e90 days - See CO2Meter Terms and Conditions\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"documents\"\u003e\n\u003ch3\u003eDocuments\u003c\/h3\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/rmtplusstoragesenseair.blob.core.windows.net\/docs\/publicerat\/PSH0127.pdf\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/CO2METER_PDF.png?1094\" alt=\"Datasheet\"\u003e\u003cstrong\u003e\u003cspan style=\"color: red;\"\u003e Data Sheet (pdf)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/rmtplusstoragesenseair.blob.core.windows.net\/docs\/publicerat\/PSP145.pdf\"\u003e\u003cimg alt=\"Manual\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/CO2METER_PDF.png?1094\"\u003e\u003cstrong\u003e\u003cspan style=\"color: red;\"\u003e Manual (pdf)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/rmtplusstoragesenseair.blob.core.windows.net\/docs\/Dev\/publicerat\/TDE2336.pdf\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/CO2METER_PDF.png?1094\" alt=\"Modbus Guide\"\u003e\u003cstrong\u003e\u003cspan style=\"color: red;\"\u003e Modbus Guide (pdf)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/rmtplusstoragesenseair.blob.core.windows.net\/docs\/Dev\/publicerat\/TDE4700.pdf\"\u003e\u003cimg alt=\"I2C Communication Guide\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/CO2METER_PDF.png?1093\"\u003e\u003cstrong\u003e\u003cspan style=\"color: red;\"\u003e I2C Communication Guide (pdf)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/SenseAirCommGuide.zip?v=1638914112\"\u003e\u003cimg alt=\"\"\u003e\u003cstrong\u003e\u003cspan style=\"color: red;\"\u003e Communication Protocols Manuals (zip)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/AN_SE_0020_Sensor_Calibration_Procedure_2023.pdf?v=1706541759\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/CO2METER_PDF.png?1094\" alt=\"\"\u003e\u003cstrong\u003e\u003cspan style=\"color: red;\"\u003e Sensor Calibration Procedure (pdf)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003ch3\u003eCase Studies\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003ca href=\"\/en-ca\/blogs\/news\/senseair-co2-sensor-compares-favorably-against-vaisala-co2-probe\" title=\"SenseAir CO2 Sensor Compares Favorably Against Vaisala CO2 Probe\"\u003eSenseAir CO2 Sensor Compares Favorably Against Vaisala CO2 Probe\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"software\"\u003e\n\u003ch3\u003eFree Easy-to-use GasLab™ Software\u003c\/h3\u003e\n\u003cp\u003eThis device uses GasLab® software for setup, calibration, data logging, and real-time data analysis. GasLab® makes it easy to export data into a .CSV file that can be imported into any industry-standard software or spreadsheet. GasLab® runs on Windows XP or higher, and free to use with our products.\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"\/en-ca\/pages\/downloads\"\u003e\u003cimg alt=\"Download Latest Software Here\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/download-drivers.gif?1253980035\"\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"accessories\"\u003e\n\u003ch3\u003eAccessories\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003ca href=\"\/en-ca\/products\/sensor-tube-cap-kit\"\u003eTube Cap Adapter CM-0114\u003c\/a\u003e - easily converts K33 ELG from an ambient sensor air to an IN\/OUT tube sampling sensor. Use with Sample Draw Pump Kit for a complete sampling solution.\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"\/en-ca\/products\/gas-sensor-micro-pump\"\u003eSample Draw Pump Kit\u003c\/a\u003e - includes pump, hose, filters\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"\/en-ca\/products\/usb2-0-extension-cable\"\u003e\u003cspan class=\"caps\"\u003eUSB\u003c\/span\u003e Extension Cable\u003c\/a\u003e - extend USB cable \u003cspan\u003e16 ft. (5m)\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Senseair","offers":[{"title":"033-8-0007 - K33 ELG 1% CO2 Temp \u0026 RH Sensor","offer_id":42821041127622,"sku":"033-8-0007","price":198.0,"currency_code":"USD","in_stock":true},{"title":"CM-0026 - K33 ELG 1% CO2 + RH\/T Development Kit","offer_id":40170011066566,"sku":"CM-0026","price":362.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/033-8-0007K33ELG10_000ppmCO2_RH_TDataLoggingSensorlCO2Meter_SE-0020_c5160b6b-424e-4928-8f37-190111f93b83.jpg?v=1753284218"},{"product_id":"k-33-icb-co2-sensor","title":"033-9-0027 K33 ICB 30% CO2 Sensor","description":"\u003cp\u003eThe\u003cstrong\u003e \u003cspan style=\"color: #115e67;\"\u003e(033-9-0027) K33 ICB CO2 sensor\u003c\/span\u003e \u003c\/strong\u003e\u003cem\u003e(formerly known as the SE-0026)\u003c\/em\u003e is designed to measure up to 30% carbon dioxide in real time in biological or scientific applications where artificially high levels of CO2 are maintained in an enclosed apparatus.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eLong-life NDIR CO2 Sampling Sensor\u003c\/li\u003e\n\u003cli\u003eEasy communication using industry standard I\/O\u003c\/li\u003e\n\u003cli\u003eLittle interference or cross sensitivity from NO2 below and CO above\u003c\/li\u003e\n\u003cli\u003eProperly configured, can take a sample containing almost 100% humidity\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eModels\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCM-0027 K33 ICB 30% CO2 Sensor Development Kit\u003c\/strong\u003e - Easy to use, simply plug the sensor module into your PC via USB. \u003cspan\u003eThe Devkit includes a K33 ICB sensor with pre-soldered connectors that provide power and connectivity. Use it for evaluation, rapid application development or for experiments. \u003c\/span\u003eUses our free GasLab® software to measure and graph carbon dioxide, to configure the sensor or for data logging.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e033-9-0027: K33 ICB 30% CO2 Sensor Only\u003c\/strong\u003e - for integration into high-volume OEM products. Contact us directly for wholesale pricing on large quantities of this sensor. \u003ca href=\"https:\/\/www.co2meter.com\/collections\/10-co2\/products\/k-33-icb-10-co2-sensor\" title=\"high accuracy 10% co2 sensor\"\u003eFor higher accuracy 10% CO2 model click here\u003c\/a\u003e.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv class=\"specifications\"\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMeasurement Range:\u003c\/strong\u003e 0 – 300,000 ppm (0-30%)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCO2 Measurement:\u003c\/strong\u003e non-dispersive infrared (NDIR)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eResponse Time:\u003c\/strong\u003e \u0026lt;20s, diffusion or tube IN\/OUT (0.2l\/minute gas flow)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRate of Measurement:\u003c\/strong\u003e every 30 seconds\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAccuracy:\u003c\/strong\u003e \u003cspan data-teams=\"true\"\u003e±0.5% vol  ±3% of measured value\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRepeatability:\u003c\/strong\u003e \u003cspan\u003e± 0.1% vol. CO2 ± 2% of measured value\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eResolution:\u003c\/strong\u003e 0.01% \/ 100ppm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMeasurement Method:\u003c\/strong\u003e Sampling \u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCommunication Options:\u003c\/strong\u003e UART or I2C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAvailable Outputs:\u003c\/strong\u003e Digital\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSensor Life Expectancy:\u003c\/strong\u003e \u0026gt; 15 years\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaintenance Interval:\u003c\/strong\u003e no maintenance required\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSelf-Diagnostics:\u003c\/strong\u003e complete function check of the sensor module on startup\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eSensor Electrical \/ Mechanical\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Input:\u003c\/strong\u003e 5-14 VDC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCurrent Consumption:\u003c\/strong\u003e 40 mA average\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMax Current:\u003c\/strong\u003e 250 mA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDimensions:\u003c\/strong\u003e 2.0 × 2.25 × 0.62 inches\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eDevelopment Kit Includes \u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e6’ (1.8m)\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"caps\"\u003eUSB\u003c\/span\u003e -UART bridge cable (non-standard)\u003c\/li\u003e\n\u003cli\u003e6VDC universal wall power supply with connector for sensor 120\/240 VAC 50\/60 Hz\u003c\/li\u003e\n\u003cli\u003e4x AA battery pack w\/ connector for sensor\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eWarranty\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e90 days - \u003ca title=\"See CO2Meter Terms and Conditions\" href=\"https:\/\/www.co2meter.com\/pages\/terms-conditions\"\u003eSee CO2Meter Terms and Conditions\u003c\/a\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"documents\"\u003e\n\u003ch3\u003eDocuments\u003c\/h3\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/rmtplusstoragesenseair.blob.core.windows.net\/docs\/publicerat\/PSH0130.pdf\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/CO2METER_PDF.png?1094\" alt=\"Datasheet\"\u003e\u003cstrong\u003e\u003cspan style=\"color: red;\"\u003e Data Sheet (pdf)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/rmtplusstoragesenseair.blob.core.windows.net\/docs\/publicerat\/PSP141.pdf\"\u003e\u003cimg alt=\"Quick Start Guide\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/CO2METER_PDF.png?1094\"\u003e\u003cstrong\u003e\u003cspan style=\"color: red;\"\u003e Manual (pdf)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/SenseairISO.pdf?v=1613679881\"\u003e\u003cimg alt=\"Senseair ISO Certification\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/CO2METER_PDF.png?1093\"\u003e\u003cstrong\u003e\u003cspan style=\"color: red;\"\u003e Senseair ISO Certification (pdf)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/SenseAirCommGuide.zip?v=1638914112\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/assets\/zip.gif\" alt=\"\"\u003e\u003cstrong\u003e\u003cspan style=\"color: red;\"\u003e Communication Protocols Manuals (zip)\u003cbr\u003e\u003c\/span\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/AN_SE_0020_Sensor_Calibration_Procedure_2023.pdf?v=1706541759\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/CO2METER_PDF.png?1094\" alt=\"\"\u003e\u003cstrong\u003e\u003cspan style=\"color: red;\"\u003e Sensor Calibration Procedure (pdf)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003ca\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/AN171-K33-ICB-10-30-Sensor-Comparison.pdf?v=1653014626\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/CO2METER_PDF.png?1094\" alt=\"\"\u003e\u003cstrong\u003e\u003cspan style=\"color: red;\"\u003e 10% vs 30% ICB Sensor Accuracy Comparison (pdf)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003ch3\u003eCase Studies\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003ca title=\"K33 Sensor used for auto emission testing\" href=\"\/en-ca\/blogs\/news\/13380573-emission-reduction-in-diesel-engines-tested-with-k-33-co2-sensor\"\u003eEmission Reduction in Diesel Engines Tested with K-33 CO2 Sensor\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"software\"\u003e\n\u003ch3\u003eFree Easy-to-use Gaslab™ Software\u003c\/h3\u003e\n\u003cp\u003eThis device uses GasLab® software for setup, calibration, data logging, and real-time data analysis. GasLab® makes it easy to export data into a .CSV file that can be imported into any industry-standard software or spreadsheet. GasLab® runs on Windows XP or higher, and is free to use with our products.\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"\/en-ca\/pages\/downloads\"\u003e\u003cimg alt=\"Download Latest Software Here\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/download-drivers.gif?1253980035\"\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"accessories\"\u003e\n\u003ch3\u003eAccessories\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003ca href=\"\/en-ca\/products\/gas-sensor-micro-pump\"\u003eSample Draw Pump Kit\u003c\/a\u003e - includes pump, hose, filters\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"\/en-ca\/products\/usb2-0-extension-cable\"\u003eUSB Extension Cable\u003c\/a\u003e - extend USB cable 16 ft. (5m)\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"\/en-ca\/products\/probe-enclosure-development-kit\" title=\"Probe Enclosure for Development Kits\"\u003eProbe Enclosure for Development Kits\u003c\/a\u003e with hydrophobic filters.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e","brand":"Senseair","offers":[{"title":"033-9-0027: K33 ICB 30% CO2 Sensor","offer_id":19003982,"sku":"033-9-0027","price":164.0,"currency_code":"USD","in_stock":true},{"title":"CM-0027: K33 ICB 30% CO2 Sensor Dev Kit","offer_id":1074136612884,"sku":"CM-0027","price":362.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/033-9-00027K33ICB30_CO2SensorlCO2Meter.jpg?v=1753284217"},{"product_id":"cozir-2000-ppm-co2-sensor","title":"CozIR®-A 2,000 ppm CO2 Sensor","description":"\u003cp\u003e\u003cspan\u003eThe \u003cspan style=\"color: rgb(17, 94, 103);\"\u003e\u003cstrong\u003eCozIR®-A 2,000 ppm CO2 sensor\u003c\/strong\u003e\u003c\/span\u003e is designed to monitor carbon dioxide levels indoors. It is ideal for monitoring CO2 in buildings, schools, offices, or anywhere indoor air quality is important for the personal comfort of the occupants.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eFeatures\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eLow Power Consumption\u003c\/li\u003e\n\u003cli\u003e2 measurements per second\u003c\/li\u003e\n\u003cli\u003eSensor Life Expectancy \u0026gt; 15 years\u003c\/li\u003e\n\u003cli\u003eIndustry-Standard Serial Communication\u003cb\u003e\u003cbr\u003e\u003c\/b\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eModels\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eGC-0010: CozIR®-A 2,000 ppm CO2 Sensor\u003c\/strong\u003e - \u003cspan\u003efor integration into high-volume OEM products.\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e\u003ca href=\"\/en-ca\/pages\/rfq\"\u003eContact us directly\u003c\/a\u003e\u003cspan\u003e \u003c\/span\u003efor wholesale pricing on large quantities of this sensor.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCM-0187: CozIR®-A Development Kit\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e-\u003cspan\u003e \u003c\/span\u003e\u003cspan\u003eEasy to use, simply plug the sensor module into your PC via USB. Use our free GasLab® software to measure and graph carbon dioxide, to configure the sensor, or for data logging.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCM-0047: Tube Cap Adapter\u003c\/strong\u003e\u003cspan\u003e - \u003c\/span\u003e\u003cstrong\u003eThis adapter has been discontinued.\u003c\/strong\u003e\u003cspan\u003e I\u003c\/span\u003e\u003cspan\u003ef you are looking for a tube cap adapter\u003c\/span\u003e\u003cspan\u003e, please contact us directly at \u003cstrong\u003eSales@CO2Meter.com\u003c\/strong\u003e\u003c\/span\u003e\u003cspan\u003e - you MUST provide us with which sensor you have purchased for a proper \u003c\/span\u003e\u003cspan\u003esolution.\u003c\/span\u003e\u003c\/p\u003e\n\u003cdiv class=\"specifications\"\u003e\n\u003cul\u003e\n\u003cli\u003eSensing Method: NDIR with Gold-plated optics\u003c\/li\u003e\n\u003cli\u003eSample Method: Diffusion (Optional Sampling with Tube Cap)\u003c\/li\u003e\n\u003cli\u003eMeasurement Range: 0-2,000 ppm (parts per million)\u003c\/li\u003e\n\u003cli\u003eMeasurement Rate: 0.5 sec \/ measurement\u003c\/li\u003e\n\u003cli\u003eAccuracy: ±50 ppm ± 3% of reading\u003c\/li\u003e\n\u003cli\u003eResolution: 1ppm\u003c\/li\u003e\n\u003cli\u003ePressure Dependence: 0.13% of reading per mm Hg\u003c\/li\u003e\n\u003cli\u003eNoise measurement: \u0026lt; 10 ppm\u003c\/li\u003e\n\u003cli\u003eAuto Calibration Default (can be changed in software)\u003c\/li\u003e\n\u003cli\u003eSerial communication 9600\/ 8\/ 1\/ n\u003c\/li\u003e\n\u003cli\u003eAnalog voltage output proportional to CO2 concentration\u003c\/li\u003e\n\u003cli\u003eSensor Life\u003cspan\u003e \u003c\/span\u003eExpectancy:\u003cspan\u003e \u003c\/span\u003e\u0026gt; 15 years\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eGeneral Performance\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eWarm-up Time: \u0026lt; 10 seconds (1.2s to first reading)\u003c\/li\u003e\n\u003cli\u003eOperating Conditions: 0°C to 50°C, 0-95% RH, 500 mbar to 40 bar\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eElectrical\/Mechanical\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003ePower Input: 3.3-5.5VDC (3.3V recommended)\u003c\/li\u003e\n\u003cli\u003eAverage Power Requirements: \u0026lt; 1.5mA @ 3.3V\u003c\/li\u003e\n\u003cli\u003ePeak current: 33mA\u003c\/li\u003e\n\u003cli\u003eWeight 20 grams\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eWarranty\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e90 days - See CO2Meter Terms and Conditions.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"documents\"\u003e\n\u003ch3\u003eDocuments\u003c\/h3\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/CozIR-A_Data_Sheet_Rev_4.11_-_Updated_Logo.pdf?v=1751037749\"\u003e\u003cimg alt=\"Datasheet\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/CO2METER_PDF.png?1093\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/CozIR-A_Data_Sheet_Rev_4.11_-_Updated_Logo.pdf?v=1751037749\"\u003e\u003cstrong\u003e\u003cspan style=\"color: red;\"\u003e Data Sheet (pdf) \u003c\/span\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/Manual_GC_0024_0025_0026_Revised8.pdf?v=1650749301\"\u003e\u003cimg alt=\"COZIR Manual\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/CO2METER_PDF.png?1093\"\u003e\u003cstrong\u003e\u003cspan style=\"color: red;\"\u003e Manual (pdf)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/CO2Meter-GSS-Cozir-A-User-Guide-Rev_4.1.pdf\"\u003e\u003cimg alt=\"COZIR GSS User Guide\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/CO2METER_PDF.png?1093\"\u003e\u003cstrong\u003e\u003cspan style=\"color: red;\"\u003e GSS COZIR A User Guide (pdf)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/AN145-sensor-development-kit-quick-start-guide.pdf?v=1650749355\"\u003e\u003cimg alt=\"Quick Start Guide\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/CO2METER_PDF.png?1093\"\u003e\u003cstrong\u003e\u003cspan style=\"color: red;\"\u003e DevKit Quick Start Guide (pdf)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/Mechanical_Diagram_-_CozIR-A_Cased-CO2Meter.pdf\"\u003e\u003cimg alt=\"Dimensional Sheet\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/CO2METER_PDF.png?1093\"\u003e\u003cstrong\u003e\u003cspan style=\"color: red;\"\u003e Dimensional Drawings (pdf)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/Mechanical_Diagram_-_CozIR-A_Cased-CO2Meter.pdf\"\u003e \u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/CO2METER_PDF.png?1093\" alt=\"Dimensional Sheet\"\u003e\u003c\/a\u003e \u003cspan style=\"color: #ff2a00;\"\u003e\u003ca title=\"Sensor Evaluation Kit\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/CO2_Sensor_Evaluation_Kit_User_Guide_9_June_2021_Rev_1.4.pdf?v=1640009264\" style=\"color: #ff2a00;\"\u003eSensor Evaluation\u003c\/a\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cstrong\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/2027_FM_ISO_Certificate.pdf?v=1742814585\"\u003e\u003cspan style=\"color: red;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/CO2METER_PDF.png?1094\" alt=\"GSS Quality Certification\"\u003e\u003cspan style=\"color: rgb(255, 42, 0);\"\u003e Quality Certificate - ISO9001 (pdf)\u003c\/span\u003e\u003c\/span\u003e\u003c\/a\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cbr\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"software\"\u003e\n\u003ch4\u003eFree Easy-to-use GasLab™ Software\u003c\/h4\u003e\n\u003cp\u003eThis device uses GasLab® software for setup, calibration, data logging, and real-time data analysis. GasLab® makes it easy to export data into a .CSV file that can be imported into any industry-standard software or spreadsheet. GasLab® runs on Windows XP or higher, and free to use with our products\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"\/en-ca\/pages\/downloads\"\u003e\u003cimg alt=\"Download Latest Software Here\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/download-drivers.gif?1253980035\"\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"accessories\"\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"\/en-ca\/products\/gas-sensor-micro-pump\"\u003eSample Draw Pump Kit\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e","brand":"GSS","offers":[{"title":"CozIR®-A 2,000ppm CO2","offer_id":72168722,"sku":"GC-0010","price":142.0,"currency_code":"USD","in_stock":false},{"title":"CozIR®-A Development Kit","offer_id":209887967,"sku":"CM-0187","price":175.0,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/products\/cozir-a-2000-ppm-co2-sensor-130252.jpg?v=1753284200"},{"product_id":"k-30-fr-co2-sensor","title":"030-8-0010 K30 FR Fast Response 10,000 ppm CO2 Sensor","description":"\u003cp\u003eThe \u003cspan style=\"color: #115e67;\" data-mce-style=\"color: #115e67;\"\u003e\u003cstrong\u003eK30 FR Fast Response 10,000 ppm CO2 Sensor 030-8-0010\u003c\/strong\u003e\u003c\/span\u003e \u003cem\u003e(formerly known as SE-0117)\u003c\/em\u003e is optimized for fast response time.\u003c\/p\u003e\n\u003cp\u003eThe sample cell is well protected by a particle filter and is designed for fast diffusion without any need for external pump. In addition, there is a tube inlet to be able to feed on-line test gas through the sensor.\u003c\/p\u003e\n\u003cp\u003eThe module is designed for high volume production with full traceability by sensor serial number on all manufacturing processes and key components. Every sensor is individually calibrated and is provided with UART digital interface.\u003c\/p\u003e\n\u003cp\u003eThe K30 FR is designed for simple integration into products that requires a fast update rate of CO2 measurement. The sensor can be used in a wide range of applications where fast changes need to be detected, such as gas leakage in the food and pharmaceutical packaging industry. Other uses are human occupancy detection and leakage detection in industry environments.is a low-cost sensor solution for OEMs who want to integrate CO2 sensors into applications like high speed bottling head-space testing.\u003c\/p\u003e\n\u003ch2\u003eFeatures\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eOptimized for incredibly fast response (2 seconds!)\u003c\/li\u003e\n\u003cli\u003eBuilt-in tube inlet with fast diffusion with or without pump\u003c\/li\u003e\n\u003cli\u003eFlexible analog and digital outputs\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eCompliant with ANSI\/ASHRAE, WELL, and RESET grad B standards\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eModels\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eK30 FR 10,000 ppm Sensor\u003c\/strong\u003e (030-8-0010) - For integration into high-volume OEM products.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eK30 CO2 Sensor Development Kit\u003c\/strong\u003e (CM-0126) - Easy to use, simply plug the sensor module into your PC via USB. Use our free \u003ca href=\"https:\/\/www.co2meter.com\/pages\/downloads\" title=\"Gaslab Software\"\u003eGasLab® software\u003c\/a\u003e to measure and graph carbon dioxide in real time or for data logging.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSensor Development Kit\u003c\/strong\u003e (CM-200) - Easy to use, simply plug the sensor into the PCB and plug it into your PC via USB. Use our free \u003ca title=\"Gaslab software\" href=\"\/en-ca\/pages\/downloads\"\u003eGasLab® software\u003c\/a\u003e to measure and graph carbon dioxide or use our \u003ca rel=\"noopener\" title=\"Source code on Github\" href=\"https:\/\/github.com\/co2meter-org\/ExampleCode\" target=\"_blank\"\u003elibrary of source code on Github\u003c\/a\u003e to build your own application or for OEM batch testing\/configuration. Order sensors on this page, then \u003ca title=\"Gas Sensor Development Kit\" href=\"https:\/\/www.co2meter.com\/products\/gas-sensor-development-kit\"\u003eorder the Devkit here\u003c\/a\u003e.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan style=\"color: #286adc;\" data-mce-style=\"color: #286adc;\"\u003e\u003cstrong\u003eWe recommend that all first-time users purchase either the CM-0126 or CM-200 Development Kit for fastest and easiest results\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cdiv class=\"specifications\"\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCO2 Measurement:\u003c\/strong\u003e Non-dispersive infrared (NDIR)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMeasurement Method:\u003c\/strong\u003e Diffusion\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMeasurement Range:\u003c\/strong\u003e 0 - 10,000 ppm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRate of Measurement:\u003c\/strong\u003e 2Hz (once every 0.5 seconds)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eResponse Time:\u003c\/strong\u003e 2 seconds @ .5 l\/min tube gas flow\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAvailable Outputs:\u003c\/strong\u003e 2 digital and 2 analog (scalable Analog voltage outputs)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProgrammable Range:\u003c\/strong\u003e 0-10,000 ppm (custom configuration required)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCommunication Options:\u003c\/strong\u003e UART or I2C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRepeatability:\u003c\/strong\u003e ± 20 ppm ± 1 % of measured value\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAccuracy:\u003c\/strong\u003e ± 30 ppm ± 3 % of measured value\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSensor Life Expectancy:\u003c\/strong\u003e \u0026gt; 15 years\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaintenance Interval:\u003c\/strong\u003e no maintenance required\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDimensions (L x W x H): \u003c\/strong\u003e51 x 57 x 14mm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWarm-up Time:\u003c\/strong\u003e \u0026lt; 1 min. (@ full specs \u0026lt; 15 min)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eConformance with the standards\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eEmission: EN61000-6-3:2001\u003c\/li\u003e\n\u003cli\u003eImmunity: EN61000-6-2:2001\u003c\/li\u003e\n\u003cli\u003eRoHS directive 2002\/95\/EG\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eElectrical \/ Mechanical\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eDimensions: 51 × 57 × 14 mm (L x W x H)\u003c\/li\u003e\n\u003cli\u003ePower Input: 5-14 VDC, stabilized to within 10% (external protection circuits required)\u003c\/li\u003e\n\u003cli\u003eMax Current: 300 mA\u003c\/li\u003e\n\u003cli\u003eCurrent Consumption: 70 mA average\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eWarranty\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e90 days - See\u003ca href=\"https:\/\/www.co2meter.com\/pages\/terms-conditions\" title=\"Terms and Conditions\"\u003e CO2Meter Terms and Conditions\u003c\/a\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"documents\"\u003e\n\u003cdiv class=\"manuals\"\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/Senseair-K30-FR-CO2Meter.pdf?v=1738682766\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/CO2METER_PDF.png?1094\" alt=\"DataSheet\"\u003e\u003cstrong\u003e\u003cspan style=\"color: red;\" data-mce-style=\"color: red;\"\u003e DataSheet (pdf)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/rmtplusstoragesenseair.blob.core.windows.net\/docs\/publicerat\/PSP109.pdf\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/CO2METER_PDF.png?1094\" alt=\"Operation Manual\"\u003e\u003cstrong\u003e\u003cspan style=\"color: red;\" data-mce-style=\"color: red;\"\u003e Operation Manual (pdf)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/Drawing_K30_K33_Revised8.pdf?v=1653005062\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/CO2METER_PDF.png?1094\" alt=\"CO2 sensor drawing\"\u003e\u003cstrong\u003e\u003cspan style=\"color: red;\" data-mce-style=\"color: red;\"\u003e Dimensional Drawings (pdf)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"http:\/\/\/co2meters.com\/Documentation\/Other\/SenseairISO.pdf\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/CO2METER_PDF.png?1093\" alt=\"Senseair ISO Certification\"\u003e\u003cstrong\u003e\u003cspan style=\"color: red;\" data-mce-style=\"color: red;\"\u003e Senseair ISO Certification (pdf)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cbr\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/AN_SE_0020_Sensor_Calibration_Procedure_2023.pdf?v=1706541759\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/CO2METER_PDF.png?1094\" alt=\"\"\u003e\u003cstrong\u003e\u003cspan style=\"color: red;\" data-mce-style=\"color: red;\"\u003e Sensor Calibration Procedure (pdf)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"technical-documents\"\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/AN_144_SE_0018_Revised8_CO2Meter.pdf?v=1702565512\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/CO2METER_PDF.png?1094\" alt=\"\"\u003e\u003cstrong\u003e\u003cspan style=\"color: red;\" data-mce-style=\"color: red;\"\u003e Web Application Using PHP and K30 DevKit (pdf)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/AN137-K30-sensor-raspberry-pi-Revised8.pdf?v=1653006660\"\u003e\u003c\/a\u003e\u003ca style=\"font-size: 0.875rem;\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/AN126-K3x-sensor-arduino-uart_2023.pdf?v=1715030056\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/CO2METER_PDF.png?1094\" alt=\"\"\u003e\u003cstrong\u003e\u003cspan style=\"color: red;\" data-mce-style=\"color: red;\"\u003e Arduino UART Instructions (pdf)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/AN126-K3x-sensor-arduino-uart_2023.pdf?v=1715030056\"\u003e\u003c\/a\u003e\u003ca style=\"font-size: 0.875rem;\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/AN_144_SE_0018_Revised8_CO2Meter.pdf?v=1702565512\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/CO2METER_PDF.png?1094\" alt=\"\"\u003e\u003cstrong\u003e\u003cspan style=\"color: red;\" data-mce-style=\"color: red;\"\u003e Troubleshooting Arduino or Raspberry Pi (pdf)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"software\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv class=\"accessories\"\u003e\n\u003ch2\u003eAccessories\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003ca title=\"CO2Meter Gas Sensor Development Kit\" href=\"https:\/\/www.co2meter.com\/products\/gas-sensor-development-kit\"\u003e\u003cstrong\u003eGas Sensor Development Kit \u003c\/strong\u003e\u003c\/a\u003e- designed to provide customers with an easy drop-in solution. Includes our free \u003ca href=\"https:\/\/www.co2meter.com\/pages\/downloads\" title=\"Gaslab data logging software\"\u003eGaslab data logging software\u003c\/a\u003e. Sensor sold separately.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003ca href=\"\/en-ca\/products\/gas-sensor-micro-pump\"\u003eSample Draw Pump Kit\u003c\/a\u003e\u003c\/strong\u003e includes all the components you need with a sample draw sensor to create a closed CO2 measurement system.\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"\/en-ca\/products\/probe-enclosure-development-kit\" title=\"View the Probe Enclosure for Development Kits\"\u003e\u003cstrong\u003eProbe Enclosure\u003c\/strong\u003e\u003c\/a\u003e. Includes hydrophobic filters, protects the sensor when used in hostile environments.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e","brand":"Senseair","offers":[{"title":"030-8-0010: K30-FS Fast Response 1% CO2 Sensor","offer_id":79643982,"sku":"030-8-0010","price":49.0,"currency_code":"USD","in_stock":true},{"title":"CM-0126: K30 FR Sensor Development Kit","offer_id":43943405322438,"sku":"CM-0126","price":252.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/030-8-0010K30FRFastResponse10_000ppmCO2SensorlCO2Meter.jpg?v=1753284195"},{"product_id":"k-30-co2-sensor","title":"030-7-0007 K30 10% CO2 Sensor","description":"\u003cdiv style=\"text-align: left;\"\u003eThe \u003cspan style=\"color: #115e67;\"\u003e\u003cstrong\u003eK30 10% (100,000 ppm) CO2 sensor\u003c\/strong\u003e\u003c\/span\u003e \u003cstrong\u003e\u003c\/strong\u003e(\u003cem\u003eformerly known as SE-0118)\u003c\/em\u003e is a high performance CO2 sensor used commonly in scientific, medical, and biological applications. It is an accurate, low-cost solution for OEMs products like CO2 safety alarms or leak detectors.\u003c\/div\u003e\n\u003ch2\u003eFeatures\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eBuilt on tested K30 Sensor platform\u003c\/li\u003e\n\u003cli\u003eSimple to install, pre-calibrated and ready-to-use\u003c\/li\u003e\n\u003cli\u003eProven reliability, low cost\u003c\/li\u003e\n\u003cli\u003eFlexible analog and digital outputs\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eModels\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e030-7-0007 - K30 10% CO2 Sensor\u003c\/strong\u003e - F\u003cspan\u003eor integration into high-volume OEM products.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e030-7-0007-C - K30 10% CO2 Sensor with Custom Outputs \u003c\/strong\u003e-  Customize analog or digital outputs for your application. After ordering, email or fax the \u003cmeta charset=\"utf-8\"\u003e \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/SE-0018-Configuration-Options-Form-2022.pdf\" title=\"Custom Outputs E-Mail Form\"\u003eCustom Outputs PDF form\u003c\/a\u003e under the Documents tab and we will custom-configure your sensor’s settings. If the form is not received, your sensor will be delivered with the default specifications.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCM-0049 - K30 CO2 Sensor Development Kit\u003c\/strong\u003e - Easy to use, simply plug the sensor module into your PC via USB. Use our free \u003ca title=\"Gaslab Software\" href=\"https:\/\/www.co2meter.com\/pages\/downloads\"\u003eGasLab® software\u003c\/a\u003e to measure and graph carbon dioxide in real time or for data logging.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCM-200 - Sensor Development Kit\u003c\/strong\u003e - Easy to use, simply plug the sensor into the PCB and plug it into your PC via USB. Use our free \u003ca title=\"Gaslab software\" href=\"\/en-ca\/pages\/downloads\"\u003eGasLab® software\u003c\/a\u003e to measure and graph carbon dioxide or use our \u003ca rel=\"noopener\" title=\"Source code on Github\" href=\"https:\/\/github.com\/co2meter-org\/ExampleCode\" target=\"_blank\"\u003elibrary of source code on Github\u003c\/a\u003e to build your own application or for OEM batch testing\/configuration. Order sensors on this page, then \u003ca title=\"Gas Sensor Development Kit\" href=\"https:\/\/www.co2meter.com\/products\/gas-sensor-development-kit\"\u003eorder the Devkit here\u003c\/a\u003e.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan style=\"color: #286adc;\"\u003e\u003cstrong\u003eWe recommend that all first-time users purchase either the CM-0049 or CM-200 Development Kit for fastest and easiest results.\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cdiv class=\"specifications\"\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCO2 Measurement:\u003c\/strong\u003e non-dispersive infrared (NDIR)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMeasurement Method:\u003c\/strong\u003e Diffusion\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMeasurement Range:\u003c\/strong\u003e 0-100,000 ppm (0-10%)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRate of Measurement:\u003c\/strong\u003e  0.5Hz (every 2 seconds)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eResponse Time Diffusion:\u003c\/strong\u003e 20 seconds\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAccuracy:\u003c\/strong\u003e \u003cmeta charset=\"utf-8\"\u003e±30ppm ±3% of reading\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWarm-up Time:\u003c\/strong\u003e \u0026lt; 1 minute\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAvailable Outputs:\u003c\/strong\u003e 2 analog, 2 digital\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eScalable Analog voltage outputs\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eAnalog output pre-set to 3% - up to 10% available upon request\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eEach digital output has threshold and hysteresis \u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProgrammable Range:\u003c\/strong\u003e 0-100,000 ppm (custom configuration available)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCommunication Options:\u003c\/strong\u003e UART or I2C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSensor Life Expectancy:\u003c\/strong\u003e \u0026gt;15 years\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eConformance with Standards\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eEmission: EN61000-6-3:2001\u003c\/li\u003e\n\u003cli\u003eImmunity: EN61000-6-2:2001\u003c\/li\u003e\n\u003cli\u003eRoHS directive 2002\/95\/EG\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eElectrical \/ Mechanical\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eDimensions: 51 × 57 × 14 mm (Length x Width x approximate Height)\u003c\/li\u003e\n\u003cli\u003ePower Input: 4.5-14 VDC, stabilized to within 10% (external protection circuits required)\u003c\/li\u003e\n\u003cli\u003eMax Current: 300 mA\u003c\/li\u003e\n\u003cli\u003eCurrent Consumption: 40 mA average, \u0026lt; 300mA peak\u003c\/li\u003e\n\u003cli\u003eSampling Method: Diffusion (sampling kit optional)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eWarranty\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e90 days - See\u003ca title=\"Terms and Conditions\" href=\"https:\/\/www.co2meter.com\/pages\/terms-conditions\"\u003e CO2Meter Terms and Conditions.\u003c\/a\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"documents\"\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/rmtplusstoragesenseair.blob.core.windows.net\/docs\/publicerat\/PSH0131.pdf\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/CO2METER_PDF.png?1094\" alt=\"Data Sheet\"\u003e\u003cstrong\u003e\u003cspan style=\"color: red;\"\u003e Data Sheet (pdf)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/K30_10_co2_Sensor_SE-0118_Data_Sheet_Rev1220.pdf\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/CO2METER_PDF.png?1094\" alt=\"Manual\"\u003e\u003cstrong\u003e\u003cspan style=\"color: red;\"\u003e Manual (pdf)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/AN145-sensor-development-kit-quick-start-guide.pdf?v=1650749355\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/CO2METER_PDF.png?1094\" alt=\"Quick Start Guide\"\u003e\u003cstrong\u003e\u003cspan style=\"color: red;\"\u003e Devkit Quick Start Guide (pdf)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/Drawing_K30_K33_Revised8.pdf?v=1653005062\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/CO2METER_PDF.png?1094\" alt=\"CO2 sensor drawing\"\u003e\u003cstrong\u003e\u003cspan style=\"color: red;\"\u003e Dimensional Drawings (pdf)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"http:\/\/\/co2meters.com\/Documentation\/Other\/SenseairISO.pdf\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/CO2METER_PDF.png?1093\" alt=\"Senseair ISO Certification\"\u003e\u003cstrong\u003e\u003cspan style=\"color: red;\"\u003e Senseair ISO Certification (pdf)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/rmtplusstoragesenseair.blob.core.windows.net\/docs\/Dev\/publicerat\/TDE4700.pdf\"\u003e\u003cimg alt=\"\"\u003e\u003cstrong\u003e\u003cspan style=\"color: red;\"\u003e I2C \u0026amp; Modbus Communication Manuals (zip)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/AN_SE_0020_Sensor_Calibration_Procedure_2023.pdf?v=1706541759\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/CO2METER_PDF.png?1094\" alt=\"\"\u003e\u003cstrong\u003e\u003cspan style=\"color: red;\"\u003e Sensor Calibration Procedure (pdf)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/AN141-Labview-examples.zip\"\u003e\u003cimg alt=\"\"\u003e\u003cstrong\u003e\u003cspan style=\"color: red;\"\u003e Labview Examples for SenseAir K-30 (zip)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/AN_144_SE_0018_Revised8_CO2Meter.pdf\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/CO2METER_PDF.png?1094\" alt=\"\"\u003e\u003cstrong\u003e\u003cspan style=\"color: red;\"\u003e Web Application Using PHP and K30 DevKit (pdf)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/AN137-K30-sensor-raspberry-pi-Revised8.pdf?v=1653006660\"\u003e\u003cimg alt=\"\"\u003e\u003cstrong\u003e\u003cspan style=\"color: red;\"\u003e Raspberry Pi UART Instructions (pdf)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/AN137-K30-sensor-raspberry-pi.zip?v=1653006700\"\u003e\u003cimg alt=\"\"\u003e\u003cstrong\u003e\u003cspan style=\"color: red;\"\u003e Raspberry Pi UART Sample Code (zip)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/AN126-K3x-sensor-arduino-uart_2023.pdf?v=1715030056\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/CO2METER_PDF.png?1094\" alt=\"\"\u003e\u003cstrong\u003e\u003cspan style=\"color: red;\"\u003e Arduino UART Instructions (pdf)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/AN126-K3x-sensor-arduino-uart.zip?v=1679587755\"\u003e\u003cimg alt=\"\"\u003e\u003cstrong\u003e\u003cspan style=\"color: red;\"\u003e Arduino UART Sample Code (zip)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/AN102-K30-Sensor-Arduino-I2C-2023.pdf\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/CO2METER_PDF.png?1094\" alt=\"\"\u003e\u003cstrong\u003e\u003cspan style=\"color: red;\"\u003e Arduino I2C Instructions (pdf)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/AN102-K30-Sensor-Arduino-I2C.zip?v=1679587755\"\u003e\u003cimg alt=\"\"\u003e\u003cstrong\u003e\u003cspan style=\"color: red;\"\u003e Arduino I2C Sample Code (zip)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/AN_144_SE_0018_Revised8_CO2Meter.pdf?v=1702565512\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/CO2METER_PDF.png?1094\" alt=\"\"\u003e\u003cstrong\u003e\u003cspan style=\"color: red;\"\u003e Troubleshooting Arduino or Raspberry Pi (pdf)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/K30_10_Custom_Configuration_Form.pdf?v=1683822650\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/CO2METER_PDF.png?1094\" alt=\"\"\u003e\u003cstrong\u003e\u003cspan style=\"color: red;\"\u003e K30 10% Custom Configuration Form (pdf)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"software\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv class=\"accessories\"\u003e\n\u003ch3\u003eAccessories\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003ca title=\"CO2Meter Gas Sensor Development Kit\" href=\"https:\/\/www.co2meter.com\/products\/gas-sensor-development-kit\"\u003e\u003cstrong\u003eGas Sensor Development Kit \u003c\/strong\u003e\u003c\/a\u003e- designed to provide customers with an easy drop-in solution. Includes our free \u003ca href=\"https:\/\/www.co2meter.com\/pages\/downloads\" title=\"Gaslab data logging software\"\u003eGaslab data logging software\u003c\/a\u003e. Sensor sold separately.\u003c\/li\u003e\n\u003cli\u003e\n\u003ca title=\"CO2Meter Sensor Tube Cap Adapter\" href=\"\/en-ca\/products\/sensor-flow-through-director\"\u003e\u003cstrong\u003eTube Cap Adapter\u003c\/strong\u003e\u003c\/a\u003e changes the sensor from reading CO2 in the air to a sample draw sensor. Use with a pump, tubing and filters to read CO2 levels in enclosed containers.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003ca href=\"\/en-ca\/products\/gas-sensor-micro-pump\"\u003eSample Draw Pump Kit\u003c\/a\u003e\u003c\/strong\u003e includes all the components you need with a sample draw sensor to create a closed CO2 measurement system.\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"\/en-ca\/products\/probe-enclosure-development-kit\" title=\"View the Probe Enclosure for Development Kits\"\u003e\u003cstrong\u003eProbe Enclosure\u003c\/strong\u003e\u003c\/a\u003e. Includes hydrophobic filters, protects the sensor when used in hostile environments.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e","brand":"Senseair","offers":[{"title":"030-7-0007 - K30 10% CO2 Sensor","offer_id":79646062,"sku":"030-7-0007","price":136.4,"currency_code":"USD","in_stock":true},{"title":"030-7-0007-C - K30 10% CO2 Sensor Custom","offer_id":788193247252,"sku":"030-7-0007-C","price":185.9,"currency_code":"USD","in_stock":true},{"title":"CM-0049 - K30 10% Sensor Development Kit","offer_id":43943410335942,"sku":"CM-0049","price":219.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/030-7-0007K3010_CO2Sensor_CO2Meter.jpg?v=1753284193"},{"product_id":"lp8-miniature-co2-sensor","title":"005-0-0001 Senseair LP8 10,000ppm CO2 Sensor","description":"\u003cp\u003eThe \u003cspan style=\"color: #115e67;\" data-mce-style=\"color: #115e67;\"\u003e\u003cstrong\u003e005-0-0001 \u003c\/strong\u003e\u003cstrong\u003eLP8 miniature 10,000 ppm CO2 sensor \u003c\/strong\u003e\u003c\/span\u003e(\u003cem\u003eformerly known as SE-0038) \u003c\/em\u003eis designed to monitor up to 10,000ppm CO2 concentrations in long-term battery or solar-powered applications.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eUltra-small footprint NDIR sensor\u003c\/li\u003e\n\u003cli\u003eOne measurement requires only \u003cspan data-mce-fragment=\"1\"\u003e11.9 mJ of energy\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003eDesigned for long-term battery operation\u003c\/li\u003e\n\u003cli\u003eVariable measurement period to save energy\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eA wide range of voltages (2.9-5.5V) enables a variety of power options. For example it can be powered by 3 alkaline 1.5V batteries, or a single 3.6V Li-SOCl2 battery for a more compact alternative.\u003c\/p\u003e\n\u003ch3\u003eModels\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e005-0-0001 LP8 Sensor Only\u003c\/strong\u003e - \u003cspan\u003efor integration into high-volume OEM products.\u003c\/span\u003e \u003ca href=\"https:\/\/www.co2meter.com\/pages\/rfq\" target=\"_blank\"\u003eContact us directly\u003c\/a\u003e for wholesale pricing on large quantities of this sensor.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv class=\"specifications\"\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCO2 Measurement:\u003c\/strong\u003e non-dispersive infrared (NDIR)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMeasurement Range:\u003c\/strong\u003e 0-10,000ppm CO2\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAccuracy:\u003c\/strong\u003e ± 50ppm, ± 3% of reading\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eResponse Time:\u003c\/strong\u003e 30 seconds\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMeasurement Method:\u003c\/strong\u003e Diffusion\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMeasurement Period:\u003c\/strong\u003e \u0026gt;15 seconds\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAvailable Output:\u003c\/strong\u003e Digital only\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCommunication:\u003c\/strong\u003e UART (host-slave protocol)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaintenance Interval:\u003c\/strong\u003e no maintenance required\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSelf-Diagnostics:\u003c\/strong\u003e complete function check on startup\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDimensions: \u003c\/strong\u003e\u003cspan data-mce-fragment=\"1\"\u003e32.7 × 19.7 × 8 mm (LxWxH)  \u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight: \u003c\/strong\u003e\u0026lt;8 grams\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSensor Life Expectancy:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e\u0026gt;15 years\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eElectrical \/ Mechanical\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Input:\u003c\/strong\u003e 2.9-5.5 VDC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMax Current: \u003c\/strong\u003e0.6 mA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCharge per measurement:\u003c\/strong\u003e 3.6mC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnergy per measurement:\u003c\/strong\u003e 11.9mJ @ 3.3V\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eWarranty\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e90 days - See CO2Meter Terms and Conditions \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"documents\"\u003e\n\u003ch3\u003eDocuments\u003c\/h3\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/rmtplusstoragesenseair.blob.core.windows.net\/docs\/Dev\/publicerat\/PSH1233.pdf\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/CO2METER_PDF.png?1094\" alt=\"CO2 Sensor Documention\"\u003e\u003cstrong\u003e\u003cspan style=\"color: red;\" data-mce-style=\"color: red;\"\u003e LP8 Sensor Datasheet (pdf)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/rmtplusstoragesenseair.blob.core.windows.net\/docs\/Dev\/publicerat\/PSP1334.pdf\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/CO2METER_PDF.png?1094\" alt=\"CO2 Sensor Documention\"\u003e\u003cstrong\u003e\u003cspan style=\"color: red;\" data-mce-style=\"color: red;\"\u003e LP8 Sensor Manual (pdf)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/AN_170_SE_0037_CO2_Sensor_Development_Kit_Revised8.pdf?v=1653015508\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/CO2METER_PDF.png?1094\" alt=\"CO2 Sensor Documention\"\u003e\u003cstrong\u003e\u003cspan style=\"color: red;\" data-mce-style=\"color: red;\"\u003e LP8 Sensor Power Options (pdf)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/AN_SE_0038_AN162_Revised8.pdf?v=1653015739\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/CO2METER_PDF.png?1094\" alt=\"CO2 Sensor Documention\"\u003e\u003cstrong\u003e\u003cspan style=\"color: red;\" data-mce-style=\"color: red;\"\u003e LP8 to Arduino via UART (pdf)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/SenseairISO.pdf?v=1613679881\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/CO2METER_PDF.png?1093\" alt=\"Senseair ISO Certification\"\u003e\u003cstrong\u003e\u003cspan style=\"color: red;\" data-mce-style=\"color: red;\"\u003e Senseair ISO Certification (pdf)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"software\"\u003e\u003c\/div\u003e\n\u003cdiv class=\"accessories\"\u003e\u003c\/div\u003e","brand":"Senseair","offers":[{"title":"LP8 CO2 Sensor","offer_id":22021514759,"sku":"005-0-0001","price":88.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/005-0-0001SenseairLP810_000ppmCO2SensorlCO2Meter_SE-0038.jpg?v=1753284191"},{"product_id":"25-percent-oxygen-sensor","title":"LOX-O2 UV Flux 25% Oxygen Smart Sensor","description":"\u003cp\u003eThe \u003cspan style=\"color: #115e67;\"\u003e\u003cstrong\u003eLOX-O2 UV Flux 25% Oxygen Sensor\u003c\/strong\u003e\u003c\/span\u003e (\u003cem\u003eformerly known as OX-0052)\u003c\/em\u003e is designed to be used anywhere 0-25% oxygen levels are required. This makes it a valuable safety sensor anywhere inert gases are stored or used.\u003c\/p\u003e\n\u003cp\u003eThe sensor benefits from lower power requirements than electrochemical and galvanic sensors, while providing a longer lifetime due to the non-depleting sensing principle.\u003c\/p\u003e\n\u003cp\u003eThe \u003cstrong\u003eLOX-O2\u003c\/strong\u003e is ppO2 and temperature compensated, enabling linear operation over a wide range without the need for additional system components. It does not contain lead or any other hazardous materials and has negligible cross sensitivity to other gases.\u003c\/p\u003e\n\u003ch2\u003eFeatures\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eInternally temperature compensated, no cross sensitivity\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eDirect communication to UART, no signal conditioning circuitry required\u003c\/li\u003e\n\u003cli\u003eContains no hazardous materials; RoHS \u0026amp; REACH compliant\u003c\/li\u003e\n\u003cli\u003eHigh Accuracy; Maintenance Free\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eModels\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eLOX-O2 Sensor\u003c\/strong\u003e – for integration into high-volume OEM products or for hobbyists.\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eCM-42950 \u003c\/b\u003e– O2 25% Smart Sensor w\/ MX Board (\u003cspan\u003eSame functionality as the development kit without USB cable or software). \u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCM-42951\u003c\/strong\u003e – Oxygen Smart Sensor w\/ Development Kit\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSensor Development Kit\u003c\/strong\u003e (CM-200) - Easy to use, simply plug the sensor into the PCB and plug it into your PC via USB. Use our free \u003ca href=\"\/en-ca\/pages\/downloads\" title=\"Gaslab software\"\u003eGasLab® software\u003c\/a\u003e to measure and graph carbon dioxide or use our \u003ca href=\"https:\/\/github.com\/co2meter-org\/ExampleCode\" title=\"Source code on Github\" rel=\"noopener\" target=\"_blank\"\u003elibrary of source code on Github\u003c\/a\u003e to build your own application or for OEM batch testing\/configuration. Order the sensor on this page, then \u003ca href=\"https:\/\/www.co2meter.com\/products\/gas-sensor-development-kit\" title=\"Gas Sensor Development Kit\"\u003eorder the Devkit here\u003c\/a\u003e.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan style=\"color: #286adc;\"\u003e\u003cstrong\u003eWe recommend that all first time users purchase both this sensor and the CM-200 Development Kit for fastest and easiest results.\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cdiv class=\"specifications\"\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMeasuring Gas:\u003c\/strong\u003e Oxygen\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMeasurement Range:\u003c\/strong\u003e 0.1 to 25% O2\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSensing Method:\u003c\/strong\u003e Fluorescence quenching by oxygen\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMeasurement Interval:\u003c\/strong\u003e 1 Sample\/second\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eResponse Time:\u003c\/strong\u003e \u0026lt; 60 Seconds\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWarm-Up Time:\u003c\/strong\u003e \u0026lt; 60 Seconds at 72\u003cspan\u003e°F (22°C)\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAccuracy:\u003c\/strong\u003e Better than 2% at full scale\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eResolution:\u003c\/strong\u003e 0.10% \/ 0.1mbar\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTemperature Accuracy:\u003c\/strong\u003e +\/- 2 degrees C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating Temperature:\u003c\/strong\u003e -30°C to +60°C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBarometric Pressure Range:\u003c\/strong\u003e 500 to 1200 mbar\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLifetime:\u003c\/strong\u003e \u0026gt; 5 years\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eElectrical \/ Mechanical\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eVoltage: 4.5 - 5.5 VDC\u003c\/li\u003e\n\u003cli\u003eCurrent: \u0026lt; 6mA (streaming @ 1 Sample\/sec), \u0026lt; 17mA Peak\u003c\/li\u003e\n\u003cli\u003eInterface: UART or analog\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eWarranty\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e90 days - See \u003ca href=\"https:\/\/www.co2meter.com\/pages\/terms-conditions\" title=\"Terms and Conditions\"\u003eCO2Meter Terms and Conditions.\u003c\/a\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"documents\"\u003e\n\u003cp\u003e\u003ca title=\"Data sheet for the LOX-02 UV Flux 25% Oxygen Smart Sensor\" href=\"https:\/\/sstsensing.com\/wp-content\/uploads\/2025\/06\/DS0030REV17_LuminOx-LOX-02.pdf\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/CO2METER_PDF.png?1094\" alt=\"CO2 Meter Oxygen Sensor Datasheet\"\u003e\u003cstrong\u003e\u003cspan style=\"color: red;\"\u003e Data Sheet (pdf)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca title=\"Manual for the LOX-02 UV Flux 25% Oxygen Smart Sensor\" href=\"https:\/\/sstsensing.com\/wp-content\/uploads\/2025\/05\/UG-001_LuminOx_UserGuide_rev2.pdf\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/CO2METER_PDF.png?1094\" alt=\"CO2 Meter Oxygen Sensor Datasheet\"\u003e\u003cstrong\u003e\u003cspan style=\"color: red;\"\u003e Sensor Manual (pdf)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003ch3\u003eCase Studies\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003ca href=\"\/en-ca\/blogs\/news\/f-35-oxygen-mask-oxygen-sensor-research\" title=\"Oxygen Mask Oxygen Sensor Research\"\u003eStudents use Sensor for Oxygen Mask Research\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003ca title=\"Oxygen sensor benefits\" href=\"\/en-ca\/blogs\/news\/4-ways-you-will-benefit-from-solid-state-oxygen-sensors\"\u003eSolid State Oxygen Sensor Benefits\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"software\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv class=\"accessories\"\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/www.co2meter.com\/products\/gas-sensor-development-kit\" title=\"CO2Meter Gas Sensor Development Kit\"\u003e\u003cstrong\u003eGas Sensor Development Kit\u003c\/strong\u003e (CM-200)\u003c\/a\u003e- designed to provide customers with an easy drop-in solution. Includes our free \u003ca title=\"Gaslab data logging software\" href=\"https:\/\/www.co2meter.com\/pages\/downloads\"\u003eGaslab data logging software\u003c\/a\u003e. Sensor sold separately.\u003c\/li\u003e\n\u003cli\u003e\n\u003ca title=\"Tube cap adapter\" href=\"https:\/\/www.co2meter.com\/products\/co2meter-sensor-tube-cap\"\u003e\u003cstrong\u003eTube Cap Adapter\u003c\/strong\u003e\u003c\/a\u003e - easily converts a wide range of gas sensors from diffusion applications to sampling. However, If you need a sampling sensor we recommend the \u003ca title=\"Flow through oxygen sensor\" href=\"https:\/\/www.co2meter.com\/products\/uv-flux-25-oxygen-smart-flow-through-sensor\"\u003eLOX-02-F Flow Through Oxygen Sensor\u003c\/a\u003e with tube caps instead. \u003c\/li\u003e\n\u003cli\u003e\n\u003ca title=\"micro-pump kit\" href=\"\/en-ca\/products\/gas-sensor-micro-pump\"\u003e\u003cstrong\u003eMicro-Pump Kit\u003c\/strong\u003e\u003c\/a\u003e\u003cspan\u003e \u003c\/span\u003eincludes all the tools you need to utilize the tube-cap adapters as part of a sampling sensor system.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003ca title=\"nafion tubing\" href=\"\/en-ca\/products\/nafion-gas-sample-drying-tubing\"\u003eNafion Tubing\u003c\/a\u003e \u003c\/strong\u003eis a highly selective, semi-permeable membrane to water vapor. If gases inside Nafion tubing are wetter than gases surrounding the tubing, drying will occur. If the surrounding gases are wetter, humidification will occur.\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"\/en-ca\/products\/gas-sampling-pump\"\u003e\u003cstrong\u003eMicro Gas Sampling Pumps\u003c\/strong\u003e\u003c\/a\u003e\u003cspan\u003e \u003c\/span\u003eprovide a constant flow of air across the sensor with a tube cap - perfect for bench-top testing of sensors for closed-loop sampling applications.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e","brand":"SST","offers":[{"title":"LOX-O2: UV Flux 25% Oxygen Smart Sensor","offer_id":43960894488774,"sku":"LOX-O2","price":129.0,"currency_code":"USD","in_stock":true},{"title":"CM-42950 Oxygen Sensor on MX Board","offer_id":43960891277510,"sku":"CM-42950","price":274.0,"currency_code":"USD","in_stock":true},{"title":"CM-42951 Oxygen Sensor Devkit","offer_id":43960891310278,"sku":"CM-42951","price":307.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/MicrosoftTeams-image_102.jpg?v=1753284186"},{"product_id":"sprintir-100-percent-co2-sensor","title":"SprintIR®-W 100% CO2 Sensor","description":"\u003cp\u003eThe \u003cspan style=\"color: #115e67;\"\u003e\u003cstrong\u003eSprintIR®-W Carbon Dioxide Sensor\u003c\/strong\u003e\u003c\/span\u003e is ideal for high-speed sensing requirements and measuring rapidly changing CO2 levels up to 100%. This sensor is most commonly used in healthcare, MAP, fire suppression testing and transportation applications.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eHigh-speed sensing: 20 Hz\u003c\/li\u003e\n\u003cli\u003eLow power\/energy consumption: 35 mW\u003c\/li\u003e\n\u003cli\u003eSolid-state: no moving parts, no heated filaments\u003c\/li\u003e\n\u003cli\u003eVibration and shock resistant\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eModels\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eGC-0018 SprintIR®-W 100% CO2 Sensor Only\u003c\/strong\u003e - for integration into high-volume OEM products. \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv class=\"specifications\"\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSensing Method:\u003c\/strong\u003e NDIR with Gold-plated optics\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMeasurement range:\u003c\/strong\u003e 100% CO2\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSample Method:\u003c\/strong\u003e Diffusion (Tube cap adapter optional)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAccuracy:\u003c\/strong\u003e ±300 ppm ± 5% of reading\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eResolution:\u003c\/strong\u003e 100ppm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWarm Up Time:\u003c\/strong\u003e \u0026lt; 2 secs to initial reading, \u0026lt;1 min to operational\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e 8 grams (w. tube cap 29 grams)\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eSerial communications 9600\/8\/1\/N\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSensor Life Expectancy:\u003c\/strong\u003e \u0026gt; 15 years\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eElectrical\/Mechanical\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Input:\u003c\/strong\u003e 3.2-5.5VDC (3.3V recommended)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAverage Current:\u003c\/strong\u003e \u0026lt;15mA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePeak current\u003c\/strong\u003e: 100mA\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eWarranty\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e90 days - See CO2Meter Terms and Conditions.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"documents\"\u003e\n\u003ch3\u003eDocuments\u003c\/h3\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/SprintIR-W_Data_Sheet_Rev_4.14_-_Updated_Logo.pdf?v=1755008739\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/CO2METER_PDF.png?1094\" alt=\"Datasheet\"\u003e\u003cstrong\u003e\u003cspan style=\"color: red;\"\u003e Data Sheet (pdf)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/SprintIR-W_Data_Sheet_Rev_4.11.pdf?v=1640788790\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/CO2METER_PDF.png?1094\" alt=\"SprintIR manual\"\u003e\u003cstrong\u003e\u003cspan style=\"color: red;\"\u003e Manual (pdf)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/AN145-sensor-development-kit-quick-start-guide.pdf?v=1650749355\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/CO2METER_PDF.png?1094\" alt=\"Quick Start Guide\"\u003e\u003cstrong\u003e\u003cspan style=\"color: red;\"\u003e Development Kit Quick Start Guide (pdf)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cstrong\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/2027_FM_ISO_Certificate.pdf?v=1742814585\"\u003e\u003cspan style=\"color: red;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/CO2METER_PDF.png?1094\" alt=\"GSS Quality Certification\"\u003e\u003cspan style=\"color: rgb(255, 42, 0);\"\u003e Quality Certificate - ISO9001 (pdf)\u003c\/span\u003e\u003c\/span\u003e\u003c\/a\u003e\u003c\/strong\u003e\u003cbr\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/AN015_Using_a_pump_to_sample_gas_Application_Note_Rev_1.1.pdf?v=1651156092\"\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/CO2METER_PDF.png?1094\"\u003e\u003cstrong\u003e\u003cspan style=\"color: red;\"\u003e GSS Guide for Sample Draw Pumps (pdf)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cbr\u003e\n\u003cdiv class=\"software\"\u003e\n\u003cp\u003eThis device uses GasLab® software for setup, calibration, data logging, and real-time data analysis. GasLab® makes it easy to export data into a .CSV file that can be imported into any industry-standard software or spreadsheet. GasLab® runs on Windows XP or higher, and free to use with our products.\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"http:\/\/www.co2meter.com\/pages\/downloads\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/download-drivers.gif?1253980035\" alt=\"Download Latest Software Here\"\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"accessories\"\u003e\n\u003ch3\u003eAccessories\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003ca href=\"\/en-ca\/products\/gas-sensor-micro-pump\"\u003eSample Draw Pump Kit\u003c\/a\u003e - includes pump, hose, filters\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"\/en-ca\/products\/usb2-0-extension-cable\"\u003e\u003cspan class=\"caps\"\u003eUSB\u003c\/span\u003e Extension Cable\u003c\/a\u003e - extend USB cable \u003cspan\u003e16 ft. (5m)\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003ca title=\"View the Probe Enclosure for Development Kits\" href=\"\/en-ca\/products\/probe-enclosure-development-kit\"\u003eProbe Enclosure for Development Kits\u003c\/a\u003e - protects the sensor in harsh environments, with hydrophobic filter option.\u003c\/li\u003e\n\u003cli\u003e\n\u003ca title=\"Sensor Tube Cap Adapter\" href=\"\/en-ca\/products\/co2meter-sensor-tube-cap\"\u003eTC1-5 Tube Cap Adapter\u003c\/a\u003e - easily converts sensor from diffusion applications to sampling sensor.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"GSS","offers":[{"title":"GC-0018: SprintIR®-W 100% CO2 Sensor","offer_id":212693617,"sku":"GC-0018","price":369.0,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/products\/sprintir-w-100-co2-sensor-736964.jpg?v=1753284184"},{"product_id":"cozir-co2-temperature-humidity-sensor","title":"CozIR®-A 2,000ppm CO2 + RH\/T Sensor","description":"\u003cp\u003e\u003cspan\u003eThe \u003cstrong\u003eCozIR®-A 2,000 ppm CO2 + temperature and % relative humidity sensor\u003c\/strong\u003e is designed to monitor carbon dioxide levels indoors. It is ideal for monitoring CO2 in buildings, schools, offices or anywhere indoor air quality is important for personal comfort of the occupants.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eFeatures\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eCO2, Temperature \u0026amp; %RH in a Single Sensor\u003c\/li\u003e\n\u003cli\u003eLow Power Consumption\u003c\/li\u003e\n\u003cli\u003e2 Measurements Per Second\u003c\/li\u003e\n\u003cli\u003eSensor Life Expectancy: \u0026gt; 15 years\u003c\/li\u003e\n\u003cli\u003eIndustry-Standard Serial Communication\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eModels\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eGC-0020 CozIR®-A 2,000 ppm CO2 + RH\/T Sensor\u003c\/strong\u003e - \u003cspan\u003efor integration into high-volume OEM products.\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e\u003ca href=\"\/en-ca\/pages\/rfq\" target=\"_blank\"\u003eContact us directly\u003c\/a\u003e\u003cspan\u003e \u003c\/span\u003efor wholesale pricing on large quantities of this sensor.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv class=\"specifications\"\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eCO2 Sensing Method: NDIR with Gold-plated optics\u003c\/li\u003e\n\u003cli\u003eSample Method: Diffusion (Optional Sampling with Tube Cap)\u003c\/li\u003e\n\u003cli\u003eAuto Calibration Default (can be changed in software)\u003c\/li\u003e\n\u003cli\u003eCO2 Measurement Range: 0-2,000 ppm (parts per million)\u003c\/li\u003e\n\u003cli\u003eCO2 Measurement Rate: 0.5 sec \/ measurement\u003c\/li\u003e\n\u003cli\u003eCO2 Accuracy: ±50 ppm ± 3% of reading\u003c\/li\u003e\n\u003cli\u003eResolution: 1ppm\u003c\/li\u003e\n\u003cli\u003eCO2 Pressure Dependence: 0.13% of reading per mm Hg\u003c\/li\u003e\n\u003cli\u003eCO2 Noise measurement: \u0026lt; 10 ppm\u003c\/li\u003e\n\u003cli\u003eTemperature Sensing Method: Bandgap\u003c\/li\u003e\n\u003cli\u003eTemperature Range: -0 to +55\u003cspan\u003e°C\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eTemperature Accuracy: +\/- 1°C within Range\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003eHumidity Sensing Method: Capacative\u003c\/li\u003e\n\u003cli\u003eHumidity Range: 0 to 95% RH\u003c\/li\u003e\n\u003cli\u003eHumidity Accuracy: \u003cspan\u003e+\/- 5% \u003c\/span\u003e\u003cspan\u003ewithin Range\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003eSerial communication 9600\/ 8\/ 1\/ n\u003c\/li\u003e\n\u003cli\u003eAnalog output for CO2 concentration only\u003c\/li\u003e\n\u003cli\u003eSensor Life\u003cspan\u003e \u003c\/span\u003eExpectancy:\u003cspan\u003e \u003c\/span\u003e\u0026gt; 15 years\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eGeneral Performance\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eWarm-up Time: \u0026lt; 10 seconds (1.2s to first reading)\u003c\/li\u003e\n\u003cli\u003eOperating Conditions: -22°C to 55°C, 0-95% RH, 500 mbar to 40 bar\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eElectrical\/Mechanical\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003ePower Input: 3.3-5.5VDC (3.3V recommended)\u003c\/li\u003e\n\u003cli\u003eAverage Power Requirements: \u0026lt; 1.5mA @ 3.3V\u003c\/li\u003e\n\u003cli\u003ePeak current: 33mA\u003c\/li\u003e\n\u003cli\u003eWeight 20 grams\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eWarranty\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e90 days - See CO2Meter Terms and Conditions.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"documents\"\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/CozIR-A_Data_Sheet_Rev_4.11_-_Updated_Logo.pdf?v=1751037749\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/CO2METER_PDF.png?1093\" alt=\"Datasheet\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/CozIR-A_Data_Sheet_Rev_4.11_-_Updated_Logo.pdf?v=1751037749\"\u003e\u003cstrong\u003e\u003cspan style=\"color: red;\"\u003e Data Sheet (pdf) \u003c\/span\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/Manual_GC_0024_0025_0026_Revised8.pdf?v=1650749301\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/CO2METER_PDF.png?1093\" alt=\"COZIR Manual\"\u003e\u003cstrong\u003e\u003cspan style=\"color: red;\"\u003e Manual (pdf)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/CO2Meter-GSS-Cozir-A-User-Guide-Rev_4.1.pdf\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/CO2METER_PDF.png?1093\" alt=\"COZIR GSS User Guide\"\u003e\u003cstrong\u003e\u003cspan style=\"color: red;\"\u003e GSS COZIR A User Guide (pdf)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/AN145-sensor-development-kit-quick-start-guide.pdf?v=1650749355\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/CO2METER_PDF.png?1093\" alt=\"Quick Start Guide\"\u003e\u003cstrong\u003e\u003cspan style=\"color: red;\"\u003e DevKit Quick Start Guide (pdf)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/Mechanical_Diagram_-_CozIR-A_Cased-CO2Meter.pdf\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/CO2METER_PDF.png?1093\" alt=\"Dimensional Sheet\"\u003e\u003cstrong\u003e\u003cspan style=\"color: red;\"\u003e Dimensional Drawings (pdf)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/Mechanical_Diagram_-_CozIR-A_Cased-CO2Meter.pdf\"\u003e \u003cimg alt=\"Dimensional Sheet\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/CO2METER_PDF.png?1093\"\u003e\u003c\/a\u003e \u003cspan style=\"color: #ff2a00;\"\u003e\u003ca style=\"color: #ff2a00;\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/CO2_Sensor_Evaluation_Kit_User_Guide_9_June_2021_Rev_1.4.pdf?v=1640009264\" title=\"Sensor Evaluation Kit\"\u003eSensor Evaluation\u003c\/a\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cstrong\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/2027_FM_ISO_Certificate.pdf?v=1742814585\"\u003e\u003cspan style=\"color: red;\"\u003e\u003cimg alt=\"GSS Quality Certification\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/CO2METER_PDF.png?1094\"\u003e\u003cspan style=\"color: rgb(255, 42, 0);\"\u003e Quality Certificate - ISO9001 (pdf)\u003c\/span\u003e\u003c\/span\u003e\u003c\/a\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cbr\u003e\n\u003ch3\u003eCase Studies\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003ca href=\"\/en-ca\/blogs\/news\/gss-co2-sensors-improve-growspace\" title=\"Improving Your Indoor Grow Space\"\u003eImproving Your Indoor Grow Space\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"software\"\u003e\n\u003ch4\u003eFree Easy-to-use GasLab™ Software\u003c\/h4\u003e\n\u003cp\u003eThis device uses GasLab® software for setup, calibration, data logging, and real-time data analysis. GasLab® makes it easy to export data into a .CSV file that can be imported into any industry-standard software or spreadsheet. GasLab® runs on Windows XP or higher, and free to use with our products\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"\/en-ca\/pages\/downloads\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/download-drivers.gif?1253980035\" alt=\"Download Latest Software Here\"\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"accessories\"\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"\/en-ca\/products\/gas-sensor-micro-pump\"\u003eSample Draw Pump Kit\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e","brand":"GSS","offers":[{"title":"GC-0020: CozIR®-A 2,000ppm CO2 RH\u0026T","offer_id":315482907,"sku":"GC-0020","price":164.0,"currency_code":"USD","in_stock":true},{"title":"CM-0197: CozIR®-A 2,000ppm CO2 RH\u0026T DevKit","offer_id":44567318724806,"sku":"CM-0197","price":186.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/products\/cozir-a-2000ppm-co2-rht-sensor-115703.jpg?v=1753284175"},{"product_id":"minir-co2-sensor","title":"ExplorIR®-M 5% CO2 Sensor","description":"\u003cp\u003eThe \u003cspan style=\"color: #115e67;\"\u003e\u003cstrong\u003eExplorIR®-M-5\u003c\/strong\u003e\u003c\/span\u003e \u003cspan\u003e(\u003cem\u003eformerly \u003c\/em\u003e\u003c\/span\u003e\u003cem\u003eknown as\u003cstrong\u003e \u003c\/strong\u003eMinIR-GC-0024\u003c\/em\u003e)\u003cstrong\u003e \u003c\/strong\u003eis a miniature CO2 sensor, capable of measuring up to 5% concentration. Its compact and robust design enables easy integration into gas monitoring and detection systems.\u003c\/p\u003e\n\u003cp\u003eExplorIR®-M is specifically designed for applications that require the sensor to operate reliably in extreme environmental conditions, especially where the pressure, temperature or vibration regime is particularly harsh. This makes it the ideal for applications from aerospace to food storage during transportation.\u003c\/p\u003e\n\u003cp\u003eThe sensor is designed to take 2 readings per second, making it ideal for applications where gas concentrations are rapidly changing.\u003c\/p\u003e\n\u003cp\u003eThe ExplorIR®-M uses patented solid-state optical technology, which enables the sensor to provide high accuracy CO2 measurement capability over an extended lifetime.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMeasures up to 5% CO2\u003c\/li\u003e\n\u003cli\u003eLow power CO2 sensor\u003c\/li\u003e\n\u003cli\u003eSolid-state LED optical technology\u003c\/li\u003e\n\u003cli\u003eVibration and shock resistant\u003c\/li\u003e\n\u003cli\u003eUART interface\u003c\/li\u003e\n\u003cli\u003eBuilt-in auto-zero function\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eModels\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eEXPLORIR-M-5: ExplorIR®-M-5 Sensor\u003c\/strong\u003e – (EXPLORIR-M-5) for integration into high-volume OEM products.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCM-40330: ExplorIR®-M 5% CO2 Sensor w\/ MX Board - \u003c\/strong\u003eEasy to Use, Includes the 5% CO2 Sensor and MXBoard for Relative Humidity and Pressure.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCM-40331: ExplorIR®-M 5% CO2 Sensor Development Kit \u003c\/strong\u003e- Easy to use, simply plug the sensor module into your PC via USB. Use our free \u003ca href=\"https:\/\/www.co2meter.com\/pages\/downloads\" title=\"Gaslab Software\"\u003eGasLab® software\u003c\/a\u003e to measure and graph carbon dioxide in real time or for data logging. Use a \u003ca title=\"tube cap adapter\" href=\"\/en-ca\/products\/co2meter-sensor-tube-cap\"\u003etube cap adapter\u003c\/a\u003e to create a sampling sensor.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCM-200: Sensor Development Kit\u003c\/strong\u003e - Easy to use, simply plug the sensor into the PCB and plug it into your PC via USB. Use our free \u003ca href=\"\/en-ca\/pages\/downloads\" title=\"Gaslab software\"\u003eGasLab® software\u003c\/a\u003e to measure and graph carbon dioxide or use our \u003ca href=\"https:\/\/github.com\/co2meter-org\/ExampleCode\" title=\"Source code on Github\" rel=\"noopener\" target=\"_blank\"\u003elibrary of source code on Github\u003c\/a\u003e to build your own application or for OEM batch testing\/configuration. Order sensors on this page, then \u003ca href=\"https:\/\/www.co2meter.com\/products\/gas-sensor-development-kit\" title=\"Gas Sensor Development Kit\"\u003eorder the Devkit here\u003c\/a\u003e.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan style=\"color: #286adc;\"\u003e\u003cstrong\u003eWe recommend that all first-time users purchase either the CM-40331 or CM-200 Development Kit for fastest and easiest results.\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cdiv class=\"specifications\"\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCO2 Sensing Method:\u003c\/strong\u003e Non-dispersive infrared (NDIR) absorption\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSample Method:\u003c\/strong\u003e \u003cspan\u003eSolid-state LED NDIR Diffusion\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMeasurement Range:\u003c\/strong\u003e 0-5%\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAccuracy:\u003c\/strong\u003e ±70 ppm +\/- 5% of reading @ STP\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTime to 1st Reading: \u003c\/strong\u003e\u0026lt;1.2 seconds\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eResolution:\u003c\/strong\u003e 10ppm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNon Linearity:\u003c\/strong\u003e \u0026lt; 1% of FS\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating Pressure Range:\u003c\/strong\u003e 950 mbar to 10 bar\n\u003cul\u003e\n\u003cli\u003eexternal pressure calibration\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePressure Dependence:\u003c\/strong\u003e 0.1% of reading per mbar @STP\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWarm-up Time:\u003c\/strong\u003e \u0026lt; 10s. 1.2 secs to first reading\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eResponse Time:\u003c\/strong\u003e \u0026lt;30 Seconds (Diffusion Limited)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eReadings per Second: \u003c\/strong\u003e2\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating Temperature:\u003c\/strong\u003e 0°C to 50°C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating Humidity: \u003c\/strong\u003e0 to 95% RH, non-condensing\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStorage Temperature: \u003c\/strong\u003e-40°C to +70°C\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDimensions:\u003c\/strong\u003e 20.9 mm x 21.7 mm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e 4g sensor\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSensor Life Expectancy: \u003c\/strong\u003e\u0026gt;15 years\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eElectrical \/ Mechanical\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Input:\u003c\/strong\u003e 3.25V to 5.5V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePeak Current:\u003c\/strong\u003e 33mA @ 2 readings\/sec.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAverage Current:\u003c\/strong\u003e \u0026lt;1.5mA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Consumption:\u003c\/strong\u003e 3.5mW @ 3.3V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMeasurement Output\/Interface:\u003c\/strong\u003e UART (Serial)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eWarranty\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e90 days - See\u003ca href=\"https:\/\/www.co2meter.com\/pages\/terms-conditions\" title=\"Terms and Conditions\"\u003e CO2Meter Terms and Conditions\u003c\/a\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"documents\"\u003e\n\u003ch3\u003eDocuments\u003c\/h3\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/ExplorIR-M_Data_Sheet_Rev_4.14_-_Updated_Logo.pdf?v=1751036376\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/CO2METER_PDF.png?1093\" alt=\"MINIR Data Sheet\"\u003e\u003cstrong\u003e\u003cspan style=\"color: red;\"\u003e Data Sheet (pdf)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/Mechanical_Diagram_-ExplorIR-M-CO2Meter.pdf\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/CO2METER_PDF.png?1093\" alt=\"MinIR Dimensional drawings\"\u003e\u003cstrong\u003e\u003cspan style=\"color: red;\"\u003e Dimensional Drawings (pdf)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/2027_FM_ISO_Certificate.pdf?v=1742814585\"\u003e\u003cspan style=\"color: red;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/CO2METER_PDF.png?1094\" alt=\"GSS Quality Certification\"\u003e\u003cspan style=\"color: rgb(255, 42, 0);\"\u003e Quality Certificate - ISO9001 (pdf)\u003c\/span\u003e\u003c\/span\u003e\u003c\/a\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"software\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv class=\"accessories\"\u003e\n\u003ch3\u003eAccessories\u003c\/h3\u003e\n\u003cp\u003e\u003ca title=\"CO2Meter Gas Sensor Development Kit\" href=\"https:\/\/www.co2meter.com\/products\/gas-sensor-development-kit\"\u003e\u003cstrong\u003eGas Sensor Development Kit\u003c\/strong\u003e (CM-200)\u003c\/a\u003e- designed to provide customers with an easy drop-in solution. Includes our free \u003ca href=\"https:\/\/www.co2meter.com\/pages\/downloads\" title=\"Gaslab data logging software\"\u003eGaslab data logging software\u003c\/a\u003e. Sensor sold separately.\u003c\/p\u003e\n\u003cp\u003e\u003ca title=\"Tube cap adapter\" href=\"https:\/\/www.co2meter.com\/collections\/accessories\/products\/co2meter-sensor-tube-cap\"\u003e\u003cstrong\u003eTube cap adapters\u003c\/strong\u003e\u003c\/a\u003e easily convert 20mm standard gas sensors from diffusion to sampling sensors. Molded polymer. \u003cstrong\u003eTube cap adapters are not pre-installed\u003c\/strong\u003e. For accurate results you must mount the tube cap permanently.\u003ca title=\"tube cap adapter\" href=\"\/en-ca\/products\/sensor-tube-cap-adapter-for-mx-board?variant=31376246079606\"\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca title=\"micro-pump kit\" href=\"\/en-ca\/products\/gas-sensor-micro-pump\"\u003e\u003cstrong\u003eMicro-Pump Kit\u003c\/strong\u003e\u003c\/a\u003e\u003cspan\u003e \u003c\/span\u003eincludes all the tools you need to utilize the tube-cap adapters as part of a sampling sensor system.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003ca title=\"nafion tubing\" href=\"\/en-ca\/products\/nafion-gas-sample-drying-tubing\"\u003eNafion Tubing\u003c\/a\u003e \u003c\/strong\u003eis a highly selective, semi-permeable membrane to water vapor. If gases inside Nafion tubing are wetter than gases surrounding the tubing, drying will occur. If the surrounding gases are wetter, humidification will occur.\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"\/en-ca\/products\/gas-sampling-pump\"\u003e\u003cstrong\u003eMicro Gas Sampling Pumps\u003c\/strong\u003e\u003c\/a\u003e\u003cspan\u003e \u003c\/span\u003eprovide a constant flow of air across the sensor with a tube cap - perfect for bench-top testing of sensors for closed-loop sampling applications.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003ca title=\"View the Probe Enclosure for Development Kits\" href=\"\/en-ca\/products\/probe-enclosure-development-kit\"\u003eProbe Enclosure for Development Kits\u003c\/a\u003e\u003c\/strong\u003e gives a strong and secure container to mount the sensor. Hydrophobic filters available for enclosure for outdoor use.\u003c\/p\u003e\n\u003cp\u003e\u003ciframe src=\"https:\/\/www.youtube.com\/embed\/wYSLkLuS-xA\" height=\"315\" width=\"560\"\u003e\u003c\/iframe\u003e\u003c\/p\u003e\n\u003c\/div\u003e","brand":"GSS","offers":[{"title":"ExplorIR-M-5: 5% CO2 Sensor","offer_id":43948792774854,"sku":"EXPLORIR-M-5","price":197.0,"currency_code":"USD","in_stock":true},{"title":"CM-40330: EXPLORIR-M 5% CO2 Sensor w\/ MX Board","offer_id":43960478073030,"sku":"CM-40330","price":395.0,"currency_code":"USD","in_stock":true},{"title":"CM-40331: ExplorIR-M 5% CO2 Sensor Devkit","offer_id":43948796379334,"sku":"CM-40331","price":428.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/EXPLORIR-M-55_CO2Sensor.jpg?v=1753284171"},{"product_id":"s8-miniature-co2-sensor","title":"004-0-0013 S8 Miniature 10,000 ppm CO2 Sensor","description":"\u003cp\u003eThe \u003cspan style=\"color: #115e67;\" data-mce-style=\"color: #115e67;\"\u003e\u003cstrong\u003eS8 Miniature 10,000 ppm (1%) Sensor\u003c\/strong\u003e\u003c\/span\u003e 004-0-0013 (\u003cem\u003eformerly known as SE-0119)\u003c\/em\u003e is designed to be used as a safety switch for indoor fresh air control and alarm applications like portable heaters or fresh air ventilation in cars.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eLow Power, Small Footprint Design\u003c\/li\u003e\n\u003cli\u003eIndividually Calibrated\u003c\/li\u003e\n\u003cli\u003eAutomatic Background Calibration (ABC)\u003c\/li\u003e\n\u003cli\u003eIndustry-Standard UART Communication\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eModels\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e004-0-0013: S8 10,000 ppm CO2 Sensor\u003c\/strong\u003e - pinless design for integration into high-volume OEM products. \u003ca href=\"\/en-ca\/pages\/rfq\"\u003eContact us directly\u003c\/a\u003e for wholesale pricing on large quantities of this sensor.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCM-0177: S8 10,000 ppm CO2 Sensor Development Kit\u003c\/strong\u003e - \u003ca href=\"\/en-ca\/pages\/rfq\"\u003eContact us directly\u003c\/a\u003e for wholesale pricing on large quantities of this product.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCM-200: Sensor Development Kit\u003c\/strong\u003e - Easy to use, simply plug the sensor into the PCB and plug it into your PC via USB. Use our free \u003ca href=\"\/en-ca\/pages\/downloads\" title=\"Gaslab software\"\u003eGasLab® software\u003c\/a\u003e to measure and graph carbon dioxide or use our \u003ca href=\"https:\/\/github.com\/co2meter-org\/ExampleCode\" title=\"Source code on Github\" rel=\"noopener\" target=\"_blank\"\u003elibrary of source code on GitHub\u003c\/a\u003e to build your own application or for OEM batch testing\/configuration. Order the sensor(s) on this page, then \u003ca href=\"https:\/\/www.co2meter.com\/products\/gas-sensor-development-kit\" title=\"Gas Sensor Development Kit\"\u003eorder the Devkit here\u003c\/a\u003e.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv class=\"specifications\"\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCO2 Measurement:\u003c\/strong\u003e non-dispersive infrared (NDIR)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMeasurement Method:\u003c\/strong\u003e diffusion\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMeasurement Range:\u003c\/strong\u003e 0-10,000 ppm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eResponse time:\u003c\/strong\u003e 90% at 2 minutes\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMeasurement Interval:\u003c\/strong\u003e 0.5 Hz (every 2 seconds)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCO2 Accuracy:\u003c\/strong\u003e ± 70ppm ± 3% of measured value\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperation Temperature: \u003c\/strong\u003e\u003cspan data-mce-fragment=\"1\"\u003e0 to 50°C\u003c\/span\u003e\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCommunication Options:\u003c\/strong\u003e UART (Modbus)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAvailable Output:\u003c\/strong\u003e analog\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaintenance Interval:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eno maintenance required\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSelf-Diagnostics:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ecomplete function check on startup\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDimensions:\u003c\/strong\u003e 32.7 × 19.7 × 8 mm (L x W x H) \u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAlarm Output: \u003c\/strong\u003eOpen \u0026gt; 1,000ppm, closed \u0026lt; 800ppm\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight: \u003c\/strong\u003e\u0026lt;8 grams\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSensor Life Expectancy:\u003c\/strong\u003e \u0026gt; 15 years\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eElectrical \/ Mechanical\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Input:\u003c\/strong\u003e 4.5V - 5.25 VDC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMax Current:\u003c\/strong\u003e 300 mA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePWM output: \u003c\/strong\u003e0 to 100% duty cycle for 0 to 2,000 ppm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Consumption:\u003c\/strong\u003e 300mA peak, 30mA average\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eWarranty\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e90 days - See\u003ca href=\"https:\/\/www.co2meter.com\/pages\/terms-conditions\" title=\"Terms and Conditions\"\u003e CO2Meter Terms and Conditions.\u003c\/a\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"documents\"\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/rmtplusstoragesenseair.blob.core.windows.net\/docs\/publicerat\/PSH0102.pdf\"\u003e\u003cimg alt=\"CO2 Sensor Documention\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/CO2METER_PDF.png?1094\"\u003e\u003cstrong\u003e\u003cspan style=\"color: red;\" data-mce-style=\"color: red;\"\u003e S8 1% Sensor Datasheet (pdf)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/rmtplusstoragesenseair.blob.core.windows.net\/docs\/publicerat\/PSP107.pdf\"\u003e\u003cimg alt=\"CO2 Sensor Documention\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/CO2METER_PDF.png?1094\"\u003e\u003cstrong\u003e\u003cspan style=\"color: red;\" data-mce-style=\"color: red;\"\u003e Manual (pdf)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/AN_168_SE_0037_Raspberry_Pi_to_SenseAir_Revised8.pdf?v=1653445714\"\u003e\u003cimg alt=\"CO2 Sensor Documention\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/CO2METER_PDF.png?1094\"\u003e\u003cstrong\u003e\u003cspan style=\"color: red;\" data-mce-style=\"color: red;\"\u003e Connecting to Raspberry Pi via UART (pdf)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/AN168-S8-raspberry-pi-files.zip?v=1653445941\"\u003e\u003cimg alt=\"\"\u003e\u003cstrong\u003e\u003cspan style=\"color: red;\" data-mce-style=\"color: red;\"\u003e Raspberry Pi Sample Code (ZIP)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/AN162-LP8-sensor-arduino-modbus-uart.pdf?v=1653446032\"\u003e\u003cimg alt=\"CO2 Sensor Documentation\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/CO2METER_PDF.png?1094\"\u003e\u003cstrong\u003e\u003cspan style=\"color: red;\" data-mce-style=\"color: red;\"\u003e Connecting to TI CC3200 WIFI via UART (pdf)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/SenseairISO.pdf?v=1613679881\"\u003e\u003cimg alt=\"Senseair ISO Certification\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/CO2METER_PDF.png?1093\"\u003e\u003cstrong\u003e\u003cspan style=\"color: red;\" data-mce-style=\"color: red;\"\u003e Senseair ISO Certification (pdf)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"software\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv class=\"accessories\"\u003e\n\u003ch3\u003eAccessories\u003c\/h3\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/www.co2meter.com\/products\/gas-sensor-development-kit\" title=\"CO2Meter Gas Sensor Development Kit\"\u003e\u003cstrong\u003eGas Sensor Development Kit \u003c\/strong\u003e\u003c\/a\u003e- designed to provide customers with an easy drop-in solution. Includes our free \u003ca title=\"Gaslab data logging software\" href=\"https:\/\/www.co2meter.com\/pages\/downloads\"\u003eGaslab data logging software\u003c\/a\u003e. Sensor sold separately.\u003c\/p\u003e\n\u003c\/div\u003e","brand":"Senseair","offers":[{"title":"004-0-0013: S8 1% CO2 Sensor","offer_id":43960925126854,"sku":"004-0-0013","price":50.6,"currency_code":"USD","in_stock":true},{"title":"CM-0177: S8 1% CO2 Sensor Development Kit","offer_id":44567318593734,"sku":"CM-0177","price":186.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/004-0-0013S8Miniature10_000ppmCO2SensorlCO2Meter_SE-0119.jpg?v=1753284164"},{"product_id":"t6713-miniature-co2-sensor","title":"T6713 Miniature 2,000ppm CO2 Sensor","description":"\u003cp\u003eAmphenol's TelAire T6713 2,000ppm Miniature CO2 Sensor combines proven NDIR technology with small size and low power requirements. It is ideal for applications where CO2 levels need to be measured and controlled for indoor air quality and energy saving applications such as demand control ventilation.\u003c\/p\u003e\n\u003cp\u003eThe T6713 continuously monitors the environment and records the lowest values, then uses automatic background calibration (ABC) logic to offset the sensor’s stored calibration. This means the sensor is best used in applications where the environment periodically drops to ambient (~400ppm) CO2 levels.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eCompact Design and Low Power Requirements\u003c\/li\u003e\n\u003cli\u003eReliable NDIR Sensing Technology\u003c\/li\u003e\n\u003cli\u003eEliminates Need for Calibration with ABC Logic\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eModels\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eAMP-0002 TelAire Miniature 2,000 ppm CO2 Sensor\u003c\/strong\u003e - \u003cspan\u003efor integration into high-volume OEM products.\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e\u003ca href=\"https:\/\/www.co2meter.com\/pages\/rfq\" target=\"_blank\"\u003eContact us directly\u003c\/a\u003e\u003cspan\u003e \u003c\/span\u003efor wholesale pricing on large quantities of this sensor.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCM-0216 TelAire Miniature 2,000 ppm\u003cspan\u003e \u003c\/span\u003eDevelopment Kit\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e-\u003cspan\u003e \u003c\/span\u003e\u003cspan\u003eEasy to use, simply plug the sensor module into your PC via USB. Use our free GasLab® software to measure and graph carbon dioxide, to configure the sensor, or for data logging.\u003c\/span\u003e\u003c\/p\u003e\n\u003cdiv class=\"specifications\"\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eCO2 Measurement: non-dispersive infrared (NDIR)\u003c\/li\u003e\n\u003cli\u003eMeasurement Method: diffusion\u003c\/li\u003e\n\u003cli\u003eMeasurement Range: 0-2,000 ppm CO2\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eAccuracy: ± 30ppm ± 3% of reading\u003c\/li\u003e\n\u003cli\u003eCalibration Interval: Not Required\u003c\/li\u003e\n\u003cli\u003eResponse Time: \u0026lt; 3 minutes for 90% step change\u003c\/li\u003e\n\u003cli\u003eSignal Update: Every 5 seconds\u003c\/li\u003e\n\u003cli\u003eWarm Up Time: \u0026lt; 2 minutes to operation\u003c\/li\u003e\n\u003cli\u003eWarm Up Time: 10 minutes to max accuracy\u003c\/li\u003e\n\u003cli\u003eAvailable Output: Digital\u003c\/li\u003e\n\u003cli\u003eCommunication Options: I2C, UART via Modbus\u003c\/li\u003e\n\u003cli\u003ePWM Output: Cycle period 1002ms (~ 1Hz) or 40µs (25kHz)\u003c\/li\u003e\n\u003cli\u003eAltitude compensation can be added if altitude is known\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eElectrical\/Mechanical\u003c\/h3\u003e\n\u003cstrong\u003eSensor\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003eDimensions: 1.08 x 0.787 x 0.34 in (30 x 15.6 x 8.6 mm)\u003c\/li\u003e\n\u003cli\u003ePower Input: 4.5-5.5 VDC\u003c\/li\u003e\n\u003cli\u003eMax Current: 200 mA\u003c\/li\u003e\n\u003cli\u003eCurrent Consumption: 200mA peak, 25mA average\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cstrong\u003eDevelopment Kit\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003eIncludes USB cable (non-standard)\u003c\/li\u003e\n\u003cli\u003e4 Pins: Tx\/Rx (UART) 5VDC, GND\u003c\/li\u003e\n\u003cli\u003eNote: If 180mA is not available on the USB bus, a powered hub is required.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eWarranty\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e90 days - See CO2Meter Terms and Conditions. \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"documents\"\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/DS-AMP-0002-T6713-Sensor.pdf?v=1653498584\"\u003e\u003cimg alt=\"Datasheet\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/CO2METER_PDF.png?1094\"\u003e\u003cstrong\u003e\u003cspan style=\"color: red;\"\u003e Data Sheet (pdf)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/Manual-AMP-0002-T6713-Sensor.pdf?v=1653498618\"\u003e\u003cimg alt=\"Manual\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/CO2METER_PDF.png?1094\"\u003e\u003cstrong\u003e\u003cspan style=\"color: red;\"\u003e Manual (pdf)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/AN145-sensor-development-kit-quick-start-guide.pdf?v=1650749355\"\u003e\u003cimg alt=\"Quick Start Guide\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/CO2METER_PDF.png?1094\"\u003e\u003cstrong\u003e\u003cspan style=\"color: red;\"\u003e DevKit Quick Start Guide (pdf)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/AN_AMP_002_Revised8.pdf?v=1653498692\"\u003e\u003cimg alt=\"Documentation\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/CO2METER_PDF.png?1094\"\u003e\u003cstrong\u003e\u003cspan style=\"color: red;\"\u003e Connect T6713 to Arduino via I2C (pdf)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/AN161-T6713-arduino-i2c.zip?v=1653498721\"\u003e\u003cimg alt=\"Documentation\"\u003e\u003cstrong\u003e\u003cspan style=\"color: red;\"\u003e Arduino Sample Code (zip)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"software\"\u003e\n\u003ch3\u003eFree Easy-to-use GasLab™ Software\u003c\/h3\u003e\n\u003cp\u003eThis device uses GasLab® software for setup, calibration, data logging, and real-time data analysis. GasLab® makes it easy to export data into a .CSV file that can be imported into any industry-standard software or spreadsheet. GasLab® runs on Windows XP or higher, and free to use with our products.\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"http:\/\/www.co2meter.com\/pages\/downloads\"\u003e\u003cimg alt=\"Download Latest Software Here\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/download-drivers.gif?1253980035\"\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e","brand":"TelAire","offers":[{"title":"T6713 2,000ppm CO2 Sensor","offer_id":36832843530,"sku":"AMP-0002","price":109.0,"currency_code":"USD","in_stock":false},{"title":"T6713 2,000ppm CO2 Sensor Development Kit","offer_id":884832731156,"sku":"CM-0216","price":149.0,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/products\/t6713-miniature-2000ppm-co2-sensor-346914.jpg?v=1753284161"},{"product_id":"cozir-lp-ambient-air-co2-sensor","title":"CozIR®-LP Miniature 5,000ppm NDIR CO2 Sensor","description":"\u003cp\u003eThe \u003cspan style=\"color: #115e67;\"\u003e\u003cstrong\u003eCozIR®-LP-5000ppm NDIR CO2 Sensor\u003c\/strong\u003e\u003c\/span\u003e (\u003cem\u003eformerly known as the GC-0027)\u003c\/em\u003e\u003cstrong\u003e \u003c\/strong\u003eis the lowest power consumption NDIR CO2 sensor available in the industry. It can run on a compact battery, removing the need for larger batteries and super-capacitors. That represents half the power consumption of the best-in-class competing CO2 sensors.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eUltra-low power CO2 sensor\u003c\/li\u003e\n\u003cli\u003e30ppm (typ.) measurement accuracy\u003c\/li\u003e\n\u003cli\u003eUART or I2C control and data interface\u003c\/li\u003e\n\u003cli\u003eMeets California Building Standards Codes, Title 24 Compliant\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eModels\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCozIR®-LP-5000ppm: Sensor Only\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e–\u003cspan\u003e \u003c\/span\u003e\u003cspan\u003efor integration into high-volume OEM products.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv class=\"specifications\"\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCO2 Measurement:\u003c\/strong\u003e NDIR with LED and gold-plated optics\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMeasurement Range:\u003c\/strong\u003e 0-5,000ppm CO2\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAccuracy:\u003c\/strong\u003e ±50ppm ±3% of reading\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eResolution:\u003c\/strong\u003e 1ppm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCommunication:\u003c\/strong\u003e Serial 9600\/ 8\/ 1\/ n\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eDiffusion Sampling\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eAuto-calibration\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eGeneral Performance\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eStart-up Time:\u003c\/strong\u003e 1.2s to first reading\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eResponse Time:\u003c\/strong\u003e \u0026lt;30 seconds (diffusion limiting)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating Pressure Range:\u003c\/strong\u003e 950 to 1050 millibar\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSensor Life Expectancy:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e\u0026gt; 15 years\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eElectrical\/Mechanical\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e33mA peak, \u0026lt; 1mA avg. power\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Input:\u003c\/strong\u003e 3.3-5.5VDC (3.3V recommended)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e 5 grams\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDimensions:\u003c\/strong\u003e 31 x 19.5 x 8mm\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eWarranty\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e90 days - See \u003ca title=\"CO2Meter Terms and Conditions\" href=\"https:\/\/www.co2meter.com\/pages\/terms-conditions\"\u003eCO2Meter Terms and Conditions.\u003c\/a\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"documents\"\u003e\n\u003ch3\u003eDocuments\u003c\/h3\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/Datasheet_COZir_LP_CO2Meter_2025.pdf\"\u003e\u003cimg alt=\"Datasheet\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/CO2METER_PDF.png?1093\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/Datasheet_COZir_LP_CO2Meter_2025.pdf\" title=\"GSS Cozir-LP Data Sheet\"\u003e\u003cstrong\u003e\u003cspan style=\"color: red;\"\u003e Data Sheet (pdf) \u003c\/span\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/AN145-sensor-development-kit-quick-start-guide.pdf?v=1650749355\"\u003e\u003cimg alt=\"Quick Start Guide\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/CO2METER_PDF.png?1093\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/Mechanical_Diagram_-_CozIR-LP-CO2Meter.pdf\"\u003e\u003cstrong\u003e\u003cspan style=\"color: red;\"\u003e Mechanical Diagram (pdf)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cstrong\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/2027_FM_ISO_Certificate.pdf?v=1742814585\"\u003e\u003cspan style=\"color: red;\"\u003e\u003cimg alt=\"GSS Quality Certification\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/CO2METER_PDF.png?1094\"\u003e\u003cspan style=\"color: rgb(255, 42, 0);\"\u003e Quality Certificate - ISO9001 (pdf)\u003c\/span\u003e\u003c\/span\u003e\u003c\/a\u003e\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"software\"\u003e\n\u003ch3\u003eFree Easy-to-use GasLab® Software \u003c\/h3\u003e\n\u003cp\u003eThis device uses GasLab® software for setup, calibration, data logging, and real-time data analysis. GasLab® makes it easy to export data into a .CSV file that can be imported into any industry-standard software or spreadsheet. GasLab® runs on Windows XP or higher, and free to use with our products.\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"\/en-ca\/pages\/downloads\"\u003e\u003cimg alt=\"Download Latest Software Here\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/download-drivers.gif?1253980035\"\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003ch3\u003eSystem Requirements for Data Logging or Changing Defaults\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eWindows XP SP2 or newer\u003c\/li\u003e\n\u003cli\u003eMicrosoft .Net 3.5 Runtime Libraries\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e","brand":"GSS","offers":[{"title":"CozIR®-LP CO2 Sensor","offer_id":40754444884,"sku":"COZIR-LP","price":88.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/COZIR-LP-5000ppm.jpg?v=1753284160"},{"product_id":"k-33-icb-10-co2-sensor","title":"033-9-0023 K33 ICB 10% CO2 Sensor","description":"\u003cp\u003eThe \u003cstrong\u003e\u003cspan style=\"color: #115e67;\"\u003e(033-9-0023) K33 ICB CO2 sensor\u003c\/span\u003e \u003c\/strong\u003e(\u003cem\u003eformerly known as SE-0025)\u003c\/em\u003e measures up to 10% carbon dioxide in biological or scientific applications where  high levels of CO2 are maintained in an enclosed environment.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eLong-life NDIR CO2 Sampling Sensor\u003c\/li\u003e\n\u003cli\u003eIndividually calibrated for peak performance\u003c\/li\u003e\n\u003cli\u003eEasy communication using industry standard I\/O\u003c\/li\u003e\n\u003cli\u003eProperly configured, can take a sample containing almost 100% humidity \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eModels\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e033-9-0023 K33 ICB 10% CO2 Sensor Only\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e- for integration into high-volume OEM products. Contact us directly for wholesale pricing on large quantities of this sensor. \u003ca href=\"https:\/\/www.co2meter.com\/products\/k-33-icb-co2-sensor\" title=\"30% CO2 Sensor\"\u003eFor our K33 ICB 30% CO2 sensor click here\u003c\/a\u003e.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCM-0058 K33 ICB 10% CO2 Sensor Development Kit\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e- Easy to use, simply plug the sensor module into your PC via USB.\u003cspan\u003e \u003c\/span\u003e\u003cspan\u003eThe Devkit includes a K33 ICB sensor with pre-soldered connectors that provide power and connectivity. Use it for evaluation, rapid application development or for experiments. \u003c\/span\u003eUses our free GasLab® software to measure and graph carbon dioxide, to configure the sensor or for data logging.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv class=\"specifications\"\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMeasurement Range:\u003c\/strong\u003e 0 – 100,000 ppm (0-10%)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCO2 Measurement:\u003c\/strong\u003e Non-dispersive infrared (NDIR)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eResponse Time:\u003c\/strong\u003e \u0026lt; 20s, sampling @ 0.2 l\/min gas flow\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAccuracy:\u003c\/strong\u003e \u003cmeta charset=\"utf-8\"\u003e±0.3%vol (CO2 ) ±3% of measured value\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eResolution:\u003c\/strong\u003e 0.001% \/ 10ppm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRepeatability:\u003c\/strong\u003e ± 100ppm vol ± 1% of measured value\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSampling Method:\u003c\/strong\u003e Sample tube draw (diffusion with cap removed)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaintenance Interval:\u003c\/strong\u003e no maintenance required\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSelf-Diagnostics:\u003c\/strong\u003e complete function check of the sensor module on startup\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDimensions:\u003c\/strong\u003e 2.0 × 2.25 × 0.62 inches\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSensor Life Expectancy:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e\u0026gt; 15 years\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eSensor Electrical \/ Mechanical\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Input:\u003c\/strong\u003e 5-14 VDC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCurrent Consumption:\u003c\/strong\u003e 40 mA average\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eDevelopment Kit Includes \u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e6’ (1.8m)\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"caps\"\u003eUSB\u003c\/span\u003e -UART bridge cable (non-standard)\u003c\/li\u003e\n\u003cli\u003e6VDC universal wall power supply with connector for sensor 120\/240 VAC 50\/60 Hz\u003c\/li\u003e\n\u003cli\u003e4x AA battery pack w\/ connector for sensor\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003ch3\u003eWarranty\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e90 days - See\u003cstrong\u003e CO2Meter Terms and Conditions.\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"documents\"\u003e\n\u003ch3\u003eDocuments\u003c\/h3\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/rmtplusstoragesenseair.blob.core.windows.net\/docs\/Dev\/publicerat\/PSH2915.pdf\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/CO2METER_PDF.png?1094\" alt=\"Datasheet\"\u003e\u003cstrong\u003e\u003cspan style=\"color: red;\"\u003e Data Sheet (pdf)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/rmtplusstoragesenseair.blob.core.windows.net\/docs\/publicerat\/PSP10329.pdf\"\u003e\u003cimg alt=\"Quick Start Guide\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/CO2METER_PDF.png?1094\"\u003e\u003cstrong\u003e\u003cspan style=\"color: red;\"\u003e Manual (pdf)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/SenseairISO.pdf?v=1613679881\"\u003e\u003cimg alt=\"Senseair ISO Certification\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/CO2METER_PDF.png?1093\"\u003e\u003cstrong\u003e\u003cspan style=\"color: red;\"\u003e Senseair ISO Certification (pdf)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/SenseAirCommGuide.zip?v=1638914112\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/assets\/zip.gif\" alt=\"\"\u003e\u003cstrong\u003e\u003cspan style=\"color: red;\"\u003e Communication Protocols Manuals (zip)\u003cbr\u003e\u003c\/span\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/AN_SE_0020_Sensor_Calibration_Procedure_2023.pdf?v=1706541759\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/CO2METER_PDF.png?1094\" alt=\"\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/AN_SE_0020_Sensor_Calibration_Procedure_2023.pdf?v=1706541759\" title=\"Sensor Calibration Procedure\" rel=\"noopener noreferrer\" target=\"_blank\"\u003e\u003cstrong\u003e\u003cspan style=\"color: red;\"\u003e Sensor Calibration Procedure (pdf)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003ca\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/AN171-K33-ICB-10-30-Sensor-Comparison.pdf?v=1653014626\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/CO2METER_PDF.png?1094\" alt=\"\"\u003e\u003cstrong\u003e\u003cspan style=\"color: red;\"\u003e 10% vs 30% ICB Sensor Accuracy Comparison (pdf)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/us.co2meter.com\/gas-monitoring-in-scientific-applications\/\"\u003e\u003cimg alt=\"Gas Monitoring in Scientific Applications Landing Page\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/LP_Revised_Icon_b214e19a-2b84-46c8-82de-4e37d32b5eb7.png\"\u003e\u003cstrong\u003e\u003cspan style=\"color: blue;\"\u003e Gas Monitoring in Science Landing Page\u003c\/span\u003e\u003c\/strong\u003e \u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"software\"\u003e\n\u003ch3\u003eFree Easy-to-use GasLab™ Software\u003c\/h3\u003e\n\u003cp\u003eThis device uses GasLab® software for setup, calibration, data logging, and real-time data analysis. GasLab® makes it easy to export data into a .CSV file that can be imported into any industry-standard software or spreadsheet. GasLab® runs on Windows XP or higher, and is free to use with our products.\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"\/en-ca\/pages\/downloads\"\u003e\u003cimg alt=\"Download Latest Software Here\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/download-drivers.gif?1253980035\"\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"accessories\"\u003e\n\u003ch3\u003eAccessories\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003ca href=\"\/en-ca\/products\/gas-sensor-micro-pump\"\u003eSample Draw Pump Kit\u003c\/a\u003e - includes pump, hose, filters\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"\/en-ca\/products\/usb2-0-extension-cable\"\u003eUSB Extension Cable\u003c\/a\u003e - extend USB cable 16 ft. (5m)\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"\/en-ca\/products\/probe-enclosure-development-kit\" title=\"Probe Enclosure for Development Kits\"\u003eProbe Enclosure for Development Kits\u003c\/a\u003e with hydrophobic filters.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e","brand":"Senseair","offers":[{"title":"033-9-0023: K33 ICB 10% CO2 Sensor","offer_id":48011342356,"sku":"033-9-0023","price":175.0,"currency_code":"USD","in_stock":true},{"title":"CM-0058: K33 ICB 10% CO2 Sensor DevKit","offer_id":1074769100820,"sku":"CM-0058","price":362.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/033-9-0023K33ICB10_CO2SensorlCO2Meter_SE-0025.jpg?v=1753284157"},{"product_id":"0-500ppm-carbon-monoxide-sensor","title":"CO-AF Alphasense 5,000ppm 20mm Carbon Monoxide Smart EC Sensor","description":"\u003cp\u003e\u003cspan\u003eThe \u003cspan style=\"color: #115e67;\"\u003e\u003cstrong\u003eCO-AF AlphaSense Carbon Monoxide sensor\u003c\/strong\u003e\u003c\/span\u003e is designed to provide accurate and reliable measurement up to 5,000ppm CO by volume in homes, offices, and industrial applications.\u003c\/span\u003e\u003c\/p\u003e\n\u003cdiv class=\"flex flex-col text-sm pb-25\"\u003e\n\u003carticle data-turn=\"assistant\" data-scroll-anchor=\"true\" data-testid=\"conversation-turn-12\" data-turn-id=\"request-WEB:b79f19d0-27e2-40d3-b56e-dc698e930046-5\" dir=\"auto\" class=\"text-token-text-primary w-full focus:outline-none [--shadow-height:45px] has-data-writing-block:pointer-events-none has-data-writing-block:-mt-(--shadow-height) has-data-writing-block:pt-(--shadow-height) [\u0026amp;:has([data-writing-block])\u0026gt;*]:pointer-events-auto scroll-mt-[calc(var(--header-height)+min(200px,max(70px,20svh)))]\" tabindex=\"-1\"\u003e\n\u003cdiv class=\"text-base my-auto mx-auto pb-10 [--thread-content-margin:--spacing(4)] @w-sm\/main:[--thread-content-margin:--spacing(6)] @w-lg\/main:[--thread-content-margin:--spacing(16)] px-(--thread-content-margin)\"\u003e\n\u003cdiv class=\"[--thread-content-max-width:40rem] @w-lg\/main:[--thread-content-max-width:48rem] mx-auto max-w-(--thread-content-max-width) flex-1 group\/turn-messages focus-visible:outline-hidden relative flex w-full min-w-0 flex-col agent-turn\" tabindex=\"-1\"\u003e\n\u003cdiv class=\"flex max-w-full flex-col grow\"\u003e\n\u003cdiv data-message-model-slug=\"gpt-5-2\" class=\"min-h-8 text-message relative flex w-full flex-col items-end gap-2 text-start break-words whitespace-normal [.text-message+\u0026amp;]:mt-1\" dir=\"auto\" data-message-id=\"74c97227-51fa-445c-903f-ce3b32e5d92e\" data-message-author-role=\"assistant\"\u003e\n\u003cdiv class=\"flex w-full flex-col gap-1 empty:hidden first:pt-[1px]\"\u003e\n\u003cdiv class=\"markdown prose dark:prose-invert w-full wrap-break-word light markdown-new-styling\"\u003e\n\u003cp data-is-only-node=\"\" data-is-last-node=\"\" data-end=\"241\" data-start=\"0\"\u003e\u003cem\u003e\u003cstrong\u003eNote: Once an electrochemical (EC) sensor is purchased from CO2Meter.com and the sealed packaging is opened or the sensor module is installed, it is no longer eligible for return due to the limited operational lifespan that begins upon activation.\u003c\/strong\u003e\u003c\/em\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/article\u003e\n\u003c\/div\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eElectrochemical Sensor Measures up to 5,000ppm Carbon Monoxide\u003c\/li\u003e\n\u003cli\u003eBarometric Pressure, Temperature and % Relative Humidity Sensors\u003c\/li\u003e\n\u003cli\u003eSerial UART output and RS485 output with optional \u003ca href=\"\/en-ca\/products\/rs485-cable-ec-mx-sensor-development-kits\" title=\"RS485 cable\"\u003eRS485 cable\u003c\/a\u003e\n\u003c\/li\u003e\n\u003cli\u003eEasy Integration; Compact \u0026amp; Low Power\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003ch3\u003eModels\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCO-AF Sensor Only\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e–\u003cspan\u003e \u003c\/span\u003e\u003cspan\u003efor integration into high-volume OEM products, 20mm diameter, the industry standard size for portable gas detectors.\u003c\/span\u003e\u003cstrong\u003e\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\n\u003cstrong\u003e\u003c\/strong\u003eSpecifications\u003c\/h3\u003e\n\u003cdiv class=\"specifications\"\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eRange:\u003c\/strong\u003e 0-5,000ppm carbon monoxide\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSensitivity:\u003c\/strong\u003e 55 to 90\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eResponse Time:\u003c\/strong\u003e t90 (s) from zero to 400ppm CO \u0026lt;25\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eZero current:\u003c\/strong\u003e -5 to +4ppm equivalent in zero air\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eResolution:\u003c\/strong\u003e \u0026lt; 0.5 RMS noise (ppm equivalent)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLinearity:\u003c\/strong\u003e +15 to +25ppm error rate at full scale from 0-1,000ppm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTemperature Range: \u003c\/strong\u003e-30 to 50°C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePressure Range: \u003c\/strong\u003e80 to 120 kPa\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHumidity Range: \u003c\/strong\u003e15 to 90% RH continuous\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStorage Period: \u003c\/strong\u003e6 months @ 3 to 20°C (stored in sealed pot)\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eZero drift:\u003c\/strong\u003e \u0026lt; 0.2\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSensitivity drift:\u003c\/strong\u003e \u0026lt; 8%\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating life:\u003c\/strong\u003e \u0026gt; 24 months until 80% original signal\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDigital Output:\u003c\/strong\u003e Serial UART\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAnalog Output:\u003c\/strong\u003e Available\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight: \u003c\/strong\u003e\u0026lt;6g\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eSmart EC Board Adds\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eTemperature, %RH, Barometric Pressure Sensors on Board\u003c\/li\u003e\n\u003cli\u003e64K memory for time-stamped data logging of all measurements  \u003c\/li\u003e\n\u003cli\u003e\n\u003cspan\u003eRS485 output with optional \u003c\/span\u003e\u003ca href=\"\/en-ca\/products\/rs485-cable-ec-mx-sensor-development-kits\" title=\"RS485 cable\"\u003eRS485 cable\u003c\/a\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eDevelopment Kit Adds\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eSmart EC Board\u003c\/li\u003e\n\u003cli\u003eSerial USB Cable\u003c\/li\u003e\n\u003cli\u003eFree GasLab Windows software for real-time measurements, data logging, graphing, sensor configuration.\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan\u003eRS485 output with optional \u003c\/span\u003e\u003ca href=\"\/en-ca\/products\/rs485-cable-ec-mx-sensor-development-kits\" title=\"RS485 cable\"\u003eRS485 cable\u003c\/a\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eElectrical\/Mechanical\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eDimensions (sensor):\u003c\/strong\u003e 16.5mm x 20.2mm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDimensions (sensor + PCB):\u003c\/strong\u003e 40mm X 25mm x 29mm (LxWxH)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Input:\u003c\/strong\u003e 3.3-5.5 VDC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCurrent Consumption:\u003c\/strong\u003e 10ma peak, \u0026lt; 3mW average\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eWarranty\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e90 days - See CO2Meter Terms and Conditions\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"documents\"\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/ametekcdn.azureedge.net\/mediafiles\/project\/oneweb\/oneweb\/alphasense\/products\/datasheets\/alphasense_co-af_datasheet_en_1.pdf?revision:9e7d08e7-70d2-4e5f-864c-01c31e407d4f\"\u003e\u003cimg alt=\"Datasheet\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/CO2METER_PDF.png?1093\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/ametekcdn.azureedge.net\/mediafiles\/project\/oneweb\/oneweb\/alphasense\/products\/datasheets\/alphasense_co-af_datasheet_en_1.pdf?revision:9e7d08e7-70d2-4e5f-864c-01c31e407d4f\" title=\"Datasheet for the CO-AF\" target=\"_blank\"\u003e\u003cstrong\u003e\u003cspan style=\"color: red;\"\u003e Data Sheet (pdf)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan style=\"font-size: 0.875rem;\"\u003eCase Studies\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"\/en-ca\/blogs\/news\/reducing-carbon-monoxide-from-vehicle-emissions\" title=\"Reducing CO levels from vehicle emissions\"\u003eReducing Carbon Monoxide from Vehicle Emissions\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"software\"\u003e\n\u003ch3\u003eFree Easy-to-use GasLab® Software\u003c\/h3\u003e\n\u003cp\u003eThe Smart EC Board uses GasLab® software for setup, calibration, data logging, and real-time data analysis. GasLab® makes it easy to export data into a .CSV file that can be imported into any industry-standard software or spreadsheet. GasLab® runs on Windows XP or higher, and free to use with our products.\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"\/en-ca\/pages\/downloads\"\u003e\u003cimg alt=\"Download Latest Software Here\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/download-drivers.gif?1253980035\"\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003ch3\u003eSystem Requirements\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eWindows XP SP2 or newer\u003c\/li\u003e\n\u003cli\u003eMicrosoft .Net 3.5 Runtime Libraries\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"accessories\"\u003e\n\u003ch3\u003eAccessories\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e\u003ca href=\"\/en-ca\/products\/co2meter-sensor-tube-cap\"\u003eTube Cap Adapters\u003c\/a\u003e \u003c\/strong\u003eeasily convert 20mm standard gas sensors from diffusion to sampling sensors. \u003cspan\u003eMolded polymer. \u003c\/span\u003e\u003cstrong\u003eTube cap adapters are not pre-installed\u003c\/strong\u003e\u003cspan\u003e. For accurate results you must \u003c\/span\u003e\u003ca href=\"http:\/\/co2meters.com\/Documentation\/Other\/Tube%20Cap%20Installation%20Procedure_rev_CO2Meter.pdf\"\u003emount the tube cap permanently\u003c\/a\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"\/en-ca\/products\/rs485-cable-ec-mx-sensor-development-kits\" title=\"RS485 Modbus cable\"\u003e\u003cstrong\u003eRS485 Cable\u003c\/strong\u003e\u003c\/a\u003e. Custom USB cable enables RS485 communication to GasLab Software for EC Sensor Board and Development Kit.\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"\/en-ca\/products\/gas-sensor-micro-pump\" title=\"micro-pump kit\"\u003e\u003cstrong\u003eMicro-Pump Kit\u003c\/strong\u003e\u003c\/a\u003e\u003cspan\u003e \u003c\/span\u003eincludes all the tools you need to utilize the tube-cap adapters as part of a sampling sensor system.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003ca href=\"\/en-ca\/products\/nafion-gas-sample-drying-tubing\" title=\"nafion tubing\"\u003eNafion Tubing\u003c\/a\u003e \u003c\/strong\u003eis a highly selective, semi-permeable membrane to water vapor. If gases inside Nafion tubing are wetter than gases surrounding the tubing, drying will occur. If the surrounding gases are wetter, humidification will occur.\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"\/en-ca\/products\/gas-sampling-pump\"\u003e\u003cstrong\u003eMicro Gas Sampling Pumps\u003c\/strong\u003e\u003c\/a\u003e\u003cspan\u003e \u003c\/span\u003eprovide a constant flow of air across the sensor with a tube cap - perfect for bench-top testing of sensors for closed-loop sampling applications.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003ca href=\"https:\/\/www.co2meter.com\/collections\/accessories\/products\/probe-enclosure-development-kit\" title=\"View the Probe Enclosure for Development Kits\"\u003eProbe Enclosure for Development Kits\u003c\/a\u003e\u003c\/strong\u003e gives a strong and secure container to mount the sensor. Hydrophobic filters available for enclosure for outdoor use.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003ch3\u003eVideos\u003c\/h3\u003e\n\u003cp\u003e\u003ciframe width=\"560\" height=\"315\" src=\"https:\/\/www.youtube.com\/embed\/wYSLkLuS-xA\"\u003e\u003c\/iframe\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"AlphaSense","offers":[{"title":"CO-AF Alphasense 5000ppm 20mm CO Sensor","offer_id":43457423737030,"sku":"","price":126.5,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/CO-AFAlphasense5_000ppm20mmCarbonMonoxideSmartECSensorlCO2Meter.jpg?v=1753284154"},{"product_id":"25-percent-oxygen-sensor-1","title":"O2-A2 Alphasense 25% 2 Year Oxygen Smart EC Sensor","description":"\u003cp\u003e\u003cspan\u003eThe \u003cspan style=\"color: #115e67;\"\u003e\u003cstrong\u003eO2-A2 Alphasense Oxygen Sensor\u003c\/strong\u003e\u003c\/span\u003e is designed to monitor 25% oxygen levels by volume. \u003c\/span\u003eThe sensor is most sought after as a replacement sensor for handheld gas detectors that use the O2-A2 sensor.\u003c\/p\u003e\n\u003cp\u003e\u003cspan data-teams=\"true\"\u003e\u003ci\u003e\u003cstrong\u003eNote: Once an electrochemical (EC) sensor is purchased from CO2Meter.com and the sealed packaging is opened or the sensor module is installed, it is no longer eligible for return due to the limited operational lifespan that begins upon activation.\u003c\/strong\u003e\u003c\/i\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eElectrochemical Sensor measures up to 25% Oxygen\u003c\/li\u003e\n\u003cli\u003eBarometric Pressure, Temperature and % Relative Humidity Sensors\u003c\/li\u003e\n\u003cli\u003eSmart EC board Adds RS485 with Optional \u003ca href=\"\/en-ca\/products\/rs485-cable-ec-mx-sensor-development-kits\" title=\"RS485 cable\"\u003eRS485 Cable\u003c\/a\u003e\n\u003c\/li\u003e\n\u003cli\u003eEasy Integration; Compact \u0026amp; Low Power\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eModels\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eO2-A2 \u003c\/span\u003eSensor Only\u003c\/strong\u003e – Sensor only.  Designed for integration into high-volume OEM products or as a replacement oxygen sensor in these 4 gas analyzers:\u003cstrong\u003e\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eCan be used as replacement sensors for:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eBW Technologies GasAlert MicroClip XT\u003c\/li\u003e\n\u003cli\u003eBW Technologies GasAlert Max XT-II\u003c\/li\u003e\n\u003cli\u003eBW Technologies GasAlert Micro 5 PID\u003c\/li\u003e\n\u003cli\u003eBW Technologies GasAlert Quattro\u003c\/li\u003e\n\u003cli\u003eBW Technologies GasAlert Extreme GAXT-DL-2\u003c\/li\u003e\n\u003cli\u003eBW Technologies GasAlert Extreme GAXT-DL-B-2\u003c\/li\u003e\n\u003cli\u003eBW Equivalent part no. \u003cspan\u003eSR-X10-C1\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003eMSA Solaris Orion Altair 4,5 (not 4X or 5X)\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eCityTech 4OX-2\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv class=\"specifications\"\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMeasurement Range:\u003c\/strong\u003e 0-20.9% oxygen\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput:\u003c\/strong\u003e 80-120 uA @ 20.9% O2\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eResponse Time:\u003c\/strong\u003e \u0026lt; 15 sec. t90 (s) from 20.9% to 0% O2\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLinearity:\u003c\/strong\u003e 0.6% O2 deviation @ 10% O2\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput drift:\u003c\/strong\u003e \u0026lt; 1% change @ 3 months\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating life:\u003c\/strong\u003e \u0026gt; 24 months until 85% original Output of 20.9% O2\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAnalog Output:\u003c\/strong\u003e 0-3VDC\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eElectrical\/Mechanical\u003cbr\u003e\n\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eDimensions (sensor):\u003c\/strong\u003e 17.4mm x 20.3mm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDimensions (sensor + PCB):\u003c\/strong\u003e 40mm X 25mm x 29mm (LxWxH)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Input:\u003c\/strong\u003e 3.3-5.5 VDC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCurrent Consumption:\u003c\/strong\u003e 10ma peak, \u0026lt; 3mW average\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eWarranty\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e90 days - See CO2Meter Terms and Conditions\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"documents\"\u003e\n\u003ch3\u003eDocuments\u003c\/h3\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/ametekcdn.azureedge.net\/mediafiles\/project\/oneweb\/oneweb\/alphasense\/products\/datasheets\/alphasense_o2-a2_datasheet_en_1.pdf?revision:b9920a9a-1297-49d7-bdb7-3ec5f47cbcf0\"\u003e\u003cimg alt=\"Datasheet\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/CO2METER_PDF.png?1093\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/ametekcdn.azureedge.net\/mediafiles\/project\/oneweb\/oneweb\/alphasense\/products\/datasheets\/alphasense_o2-a2_datasheet_en_1.pdf?revision:b9920a9a-1297-49d7-bdb7-3ec5f47cbcf0\" title=\"Datasheet for the O2-A2\"\u003e\u003cstrong\u003e\u003cspan style=\"color: red;\"\u003e Data Sheet (pdf)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/Manual-EC200-Sensors_rev_R.pdf?v=1650730719\"\u003e\u003cimg alt=\"Documentation\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/CO2METER_PDF.png?1093\"\u003e\u003cstrong\u003e\u003cspan style=\"color: red;\"\u003e Manual (pdf)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cdiv class=\"software\"\u003e\n\u003ch3\u003eFree Easy-to-use GasLab® Software\u003c\/h3\u003e\n\u003cp\u003eThe Smart EC board uses GasLab® software for setup, calibration, data logging, and real-time data analysis. GasLab® makes it easy to export data into a .CSV file that can be imported into any industry-standard software or spreadsheet. GasLab® runs on Windows XP or higher, and free to use with our products.\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"\/en-ca\/pages\/downloads\"\u003e\u003cimg alt=\"Download Latest Software Here\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/download-drivers.gif?1253980035\"\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003ch3\u003eSystem Requirements\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eWindows XP SP2 or newer\u003c\/li\u003e\n\u003cli\u003eMicrosoft .Net 3.5 Runtime Libraries\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"accessories\"\u003e\n\u003ch3\u003eAccessories\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003ca href=\"\/en-ca\/products\/co2meter-sensor-tube-cap\"\u003eTube Cap Adapters\u003c\/a\u003e \u003c\/strong\u003eeasily convert 20mm standard gas sensors from diffusion to sampling sensors. \u003cspan\u003eMolded polymer. \u003c\/span\u003e\u003cstrong\u003eTube cap adapters are not pre-installed\u003c\/strong\u003e\u003cspan\u003e. For accurate results you must \u003c\/span\u003e\u003ca href=\"http:\/\/co2meters.com\/Documentation\/Other\/Tube%20Cap%20Installation%20Procedure_rev_CO2Meter.pdf\"\u003emount the tube cap permanently\u003c\/a\u003e\u003cspan\u003e.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"\/en-ca\/products\/rs485-cable-ec-mx-sensor-development-kits\" title=\"RS485 Modbus cable\"\u003e\u003cstrong\u003eRS485 Cable\u003c\/strong\u003e\u003c\/a\u003e. Custom USB cable enables RS485 communication to GasLab Software for EC Sensor Board and Development Kit.\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"\/en-ca\/products\/gas-sensor-micro-pump\" title=\"micro-pump kit\"\u003e\u003cstrong\u003eMicro-Pump Kit\u003c\/strong\u003e\u003c\/a\u003e\u003cspan\u003e \u003c\/span\u003eincludes all the tools you need to utilize the tube-cap adapters as part of a sampling sensor system.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003ca href=\"\/en-ca\/products\/nafion-gas-sample-drying-tubing\" title=\"nafion tubing\"\u003eNafion Tubing\u003c\/a\u003e \u003c\/strong\u003eis a highly selective, semi-permeable membrane to water vapor. If gases inside Nafion tubing are wetter than gases surrounding the tubing, drying will occur. If the surrounding gases are wetter, humidification will occur.\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"\/en-ca\/products\/gas-sampling-pump\"\u003e\u003cstrong\u003eMicro Gas Sampling Pumps\u003c\/strong\u003e\u003c\/a\u003e\u003cspan\u003e \u003c\/span\u003eprovide a constant flow of air across the sensor with a tube cap - perfect for bench-top testing of sensors for closed-loop sampling applications.\u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"AlphaSense","offers":[{"title":"O2-A2 Alphasense 25% 2 Year Oxygen Smart EC Sensor","offer_id":51004969236,"sku":"O2-A2","price":77.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/O2-A2Alphasense25_2YearOxygenSmartECSensorlCO2Meter.jpg?v=1753284153"},{"product_id":"explorir-100-pct-co2-sensor","title":"ExplorIR®-M 100% CO2 Sensor","description":"\u003cp\u003eThe \u003cspan style=\"color: #115e67;\"\u003e\u003cstrong\u003eExplorIR®-M-100% CO2 Sensor\u003c\/strong\u003e\u003c\/span\u003e \u003cspan\u003e(\u003cem\u003eformerly \u003c\/em\u003e\u003c\/span\u003e\u003cem\u003eknown as\u003cstrong\u003e \u003c\/strong\u003eMinIR-GC-0025\u003c\/em\u003e)\u003cstrong\u003e \u003c\/strong\u003eis a miniature CO2 sensor, capable of measuring up to 100% concentration. Its compact and robust design enables easy integration into gas monitoring and detection systems.\u003c\/p\u003e\n\u003cp\u003eExplorIR®-M is specifically designed for applications that require the sensor to operate reliably in extreme environmental conditions, especially where the pressure, temperature or vibration regime is particularly harsh. This makes it the ideal for applications from fire systems testing to compressed CO2 transportation.\u003c\/p\u003e\n\u003cp\u003eThe sensor is designed to take 2 readings per second, making it ideal for applications where gas concentrations are rapidly changing.\u003c\/p\u003e\n\u003cp\u003eThe ExplorIR®-M uses patented solid-state optical technology, which enables the sensor to provide high accuracy CO2 measurement capability over an extended lifetime.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMeasures up to 100% CO2\u003c\/li\u003e\n\u003cli\u003eLow power CO2 sensor\u003c\/li\u003e\n\u003cli\u003eSolid-state LED optical technology\u003c\/li\u003e\n\u003cli\u003eVibration and shock resistant\u003c\/li\u003e\n\u003cli\u003eUART interface\u003c\/li\u003e\n\u003cli\u003eBuilt-in auto-zero function\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eModels\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eExplorIR®-M-100 Sensor\u003c\/strong\u003e (EXPLORIR-M-100) – for integration into high-volume OEM products.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eExplorIR®-M-100 Sensor\u003c\/strong\u003e \u003cstrong\u003ew\/ MX Board\u003c\/strong\u003e - (CM-40830) – same functionality as the development kit without USB cable or software.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eExplorIR 100% CO2 Sensor Development Kit\u003c\/strong\u003e (CM-40831) - Easy to use, simply plug the sensor PCB module into your PC via USB. Use our free \u003ca title=\"Gaslab Software\" href=\"https:\/\/www.co2meter.com\/pages\/downloads\"\u003eGasLab® software\u003c\/a\u003e to measure and graph carbon dioxide in real time or for data logging. Use a \u003ca title=\"tube cap adapter\" href=\"\/en-ca\/products\/co2meter-sensor-tube-cap\"\u003etube cap adapter\u003c\/a\u003e to create a sampling sensor.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSensor Development Kit\u003c\/strong\u003e (CM-200) - Easy to use, simply plug the sensor into the PCB and plug it into your PC via USB. Use our free \u003ca title=\"Gaslab software\" href=\"\/en-ca\/pages\/downloads\"\u003eGasLab® software\u003c\/a\u003e to measure and graph carbon dioxide or use our \u003ca rel=\"noopener\" title=\"Source code on Github\" href=\"https:\/\/github.com\/co2meter-org\/ExampleCode\" target=\"_blank\"\u003elibrary of source code on Github\u003c\/a\u003e to build your own application or for OEM batch testing\/configuration. Order sensors on this page, then \u003ca title=\"Gas Sensor Development Kit\" href=\"https:\/\/www.co2meter.com\/products\/gas-sensor-development-kit\"\u003eorder the Devkit here\u003c\/a\u003e.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan style=\"color: #286adc;\"\u003e\u003cstrong\u003eWe recommend that all first-time users purchase either the CM-40831 or CM-200 Development Kit for fastest and easiest results.\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cdiv class=\"specifications\"\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCO2 Sensing Method:\u003c\/strong\u003e Non-dispersive infrared (NDIR) absorption\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSample Method:\u003c\/strong\u003e \u003cspan\u003eSolid-state LED NDIR Diffusion\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMeasurement Range:\u003c\/strong\u003e 0-100%\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAccuracy:\u003c\/strong\u003e \u003cmeta charset=\"utf-8\"\u003e@25°C ±(300 +5%rdg) ppm \u003cbr\u003e0°C to +50°C, after zero @25°C ±(300 +5%rdg) ppm \u003cbr\u003e-25°C to +55°C, after zero @25°C ±(1000 +5%rdg) ppm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTime to 1st Reading: \u003c\/strong\u003e\u0026lt;1.2 seconds\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eResolution:\u003c\/strong\u003e 10ppm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNon Linearity:\u003c\/strong\u003e \u0026lt; 1% of FS\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating Pressure Range:\u003c\/strong\u003e 950 mbar to 10 bar\n\u003cul\u003e\n\u003cli\u003eexternal pressure calibration\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePressure Dependence:\u003c\/strong\u003e 0.1% of reading per mbar @STP\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWarm-up Time:\u003c\/strong\u003e \u0026lt; 10s. 1.2 secs to first reading\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eResponse Time:\u003c\/strong\u003e \u0026lt;30 Seconds (Diffusion Limited)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eReadings per Second: \u003c\/strong\u003e2\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating Temperature:\u003c\/strong\u003e 0°C to 50°C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating Humidity: \u003c\/strong\u003e0 to 95% RH, non-condensing\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStorage Temperature: \u003c\/strong\u003e-40°C to +70°C\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDimensions:\u003c\/strong\u003e 20.9 mm x 21.7 mm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e 4g sensor\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSensor Life Expectancy: \u003c\/strong\u003e\u0026gt;15 years\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eElectrical \/ Mechanical\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Input:\u003c\/strong\u003e 3.25V to 5.5V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePeak Current:\u003c\/strong\u003e 33mA @ 2 readings\/sec.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAverage Current:\u003c\/strong\u003e \u0026lt;1.5mA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Consumption:\u003c\/strong\u003e 3.5mW @ 3.3V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMeasurement Output\/Interface:\u003c\/strong\u003e UART (Serial)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eWarranty\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e90 days - See\u003ca title=\"Terms and Conditions\" href=\"https:\/\/www.co2meter.com\/pages\/terms-conditions\"\u003e CO2Meter Terms and Conditions\u003c\/a\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"documents\"\u003e\n\u003ch3\u003eDocuments\u003c\/h3\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/ExplorIR-M_Data_Sheet_Rev_4.14_-_Updated_Logo.pdf?v=1751036376\"\u003e\u003cimg alt=\"MINIR Data Sheet\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/CO2METER_PDF.png?1093\"\u003e\u003cstrong\u003e\u003cspan style=\"color: red;\"\u003e Data Sheet (pdf)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/Mechanical_Diagram_-ExplorIR-M-CO2Meter.pdf\"\u003e\u003cimg alt=\"MinIR Dimensional drawings\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/CO2METER_PDF.png?1093\"\u003e\u003cstrong\u003e\u003cspan style=\"color: red;\"\u003e Dimensional Drawings (pdf)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cstrong\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/2027_FM_ISO_Certificate.pdf?v=1742814585\"\u003e\u003cspan style=\"color: red;\"\u003e\u003cimg alt=\"GSS Quality Certification\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/CO2METER_PDF.png?1094\"\u003e\u003cspan style=\"color: rgb(255, 42, 0);\"\u003e Quality Certificate - ISO9001 (pdf)\u003c\/span\u003e\u003c\/span\u003e\u003c\/a\u003e\u003c\/strong\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"software\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv class=\"accessories\"\u003e\n\u003ch3\u003eAccessories\u003c\/h3\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/www.co2meter.com\/products\/gas-sensor-development-kit\" title=\"CO2Meter Gas Sensor Development Kit\"\u003e\u003cstrong\u003eGas Sensor Development Kit\u003c\/strong\u003e (CM-200)\u003c\/a\u003e- designed to provide customers with an easy drop-in solution. Includes our free \u003ca title=\"Gaslab data logging software\" href=\"https:\/\/www.co2meter.com\/pages\/downloads\"\u003eGaslab data logging software\u003c\/a\u003e. Sensor sold separately.\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/www.co2meter.com\/collections\/accessories\/products\/co2meter-sensor-tube-cap\" title=\"Tube cap adapter\"\u003e\u003cstrong\u003eTube cap adapters\u003c\/strong\u003e\u003c\/a\u003e easily convert 20mm standard gas sensors from diffusion to sampling sensors. Molded polymer. \u003cstrong\u003eTube cap adapters are not pre-installed\u003c\/strong\u003e. For accurate results you must mount the tube cap permanently.\u003ca href=\"\/en-ca\/products\/sensor-tube-cap-adapter-for-mx-board?variant=31376246079606\" title=\"tube cap adapter\"\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"\/en-ca\/products\/gas-sensor-micro-pump\" title=\"micro-pump kit\"\u003e\u003cstrong\u003eMicro-Pump Kit\u003c\/strong\u003e\u003c\/a\u003e\u003cspan\u003e \u003c\/span\u003eincludes all the tools you need to utilize the tube-cap adapters as part of a sampling sensor system.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003ca href=\"\/en-ca\/products\/nafion-gas-sample-drying-tubing\" title=\"nafion tubing\"\u003eNafion Tubing\u003c\/a\u003e \u003c\/strong\u003eis a highly selective, semi-permeable membrane to water vapor. If gases inside Nafion tubing are wetter than gases surrounding the tubing, drying will occur. If the surrounding gases are wetter, humidification will occur.\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"\/en-ca\/products\/gas-sampling-pump\"\u003e\u003cstrong\u003eMicro Gas Sampling Pumps\u003c\/strong\u003e\u003c\/a\u003e\u003cspan\u003e \u003c\/span\u003eprovide a constant flow of air across the sensor with a tube cap - perfect for bench-top testing of sensors for closed-loop sampling applications.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003ca href=\"\/en-ca\/products\/probe-enclosure-development-kit\" title=\"View the Probe Enclosure for Development Kits\"\u003eProbe Enclosure for Development Kits\u003c\/a\u003e\u003c\/strong\u003e gives a strong and secure container to mount the sensor. Hydrophobic filters available for enclosure for outdoor use.\u003c\/p\u003e\n\u003cp\u003e\u003ciframe width=\"560\" height=\"315\" src=\"https:\/\/www.youtube.com\/embed\/wYSLkLuS-xA\"\u003e\u003c\/iframe\u003e\u003c\/p\u003e\n\u003c\/div\u003e","brand":"GSS","offers":[{"title":"ExplorIR-M-100 - 100% CO2 Sensor","offer_id":43948825247942,"sku":"EXPLORIR-M-100","price":197.0,"currency_code":"USD","in_stock":true},{"title":"CM-40830 - ExplorIR-M 100% CO2 Sensor w\/ MX Board","offer_id":43960235917510,"sku":"CM-40830","price":395.0,"currency_code":"USD","in_stock":false},{"title":"CM-40831 - ExplorIR-M 100% CO2 Sensor Devkit","offer_id":43948826951878,"sku":"CM-40831","price":428.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/EXPLORIR-M-100100_CO2Sensor.jpg?v=1753284152"},{"product_id":"sprintir6s-100-co2-smart-sensor","title":"SprintIR®-6S-100 100% CO2 Sensor","description":"\u003cp\u003eThe\u003cstrong\u003e \u003cspan style=\"color: #115e67;\"\u003eSprintIR®-6S-100 100% CO2 Sensor\u003c\/span\u003e\u003c\/strong\u003e\u003cem\u003e (formerly known as the GC-0030)\u003c\/em\u003e is a high-speed CO2 sensor that can take up to 20 readings per second, It is for fire suppression testing and safety applications.\u003c\/p\u003e\n\u003cp\u003eThis sensor is fitted with a standard flow-through adaptor so the CO2 gas can be passed over the optical sensor at high speed.\u003c\/p\u003e\n\u003cp\u003eThe SprintIR®-6S-100 uses patented NDIR solid-state LED optical technology enabling the sensor to respond to rapidly changing CO2 without compromising parametric performance.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eNDIR LED sensor measures up to 100% CO2\u003c\/li\u003e\n\u003cli\u003eFast response rate - 20 readings\/second\u003c\/li\u003e\n\u003cli\u003eVibration and shock resistant\u003c\/li\u003e\n\u003cli\u003eEasy integration in compact environments\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eModels\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSprintIR-6S 100% CO2 Sensor\u003c\/strong\u003e (SPRINTIR-6S-100)– for integration into high-volume OEM products.\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSensor Development Kit\u003c\/strong\u003e (CM-200) - Easy to use, simply plug the sensor into the PCB and plug it into your PC via USB. Use our free \u003ca title=\"Gaslab software\" href=\"\/en-ca\/pages\/downloads\"\u003eGasLab® software\u003c\/a\u003e to measure and graph carbon dioxide or use our \u003ca rel=\"noopener\" title=\"Source code on Github\" href=\"https:\/\/github.com\/co2meter-org\/ExampleCode\" target=\"_blank\"\u003elibrary of source code on Github\u003c\/a\u003e to build your own application or for OEM batch testing\/configuration. Order sensors on this page, then \u003ca title=\"Gas Sensor Development Kit\" href=\"https:\/\/www.co2meter.com\/products\/gas-sensor-development-kit\"\u003eorder the Devkit here\u003c\/a\u003e.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan style=\"color: #286adc;\"\u003e\u003cstrong\u003eWe recommend that all first-time users purchase either the CM-20801 or CM-200 Development Kit for fastest and easiest results\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cdiv class=\"specifications\"\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCO2 Sensing Method:\u003c\/strong\u003e Non-dispersive infrared (NDIR) absorption\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSample Method:\u003c\/strong\u003e Flow through\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMeasurement Range\u003c\/strong\u003e: 0-100%\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAccuracy:\u003c\/strong\u003e ±70 ppm +\/- 5% of reading @ STP\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAccuracy @ 100% Range:\u003c\/strong\u003e ±300 ppm +\/-5% of reading @ STP\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating Conditions - Temperature: \u003c\/strong\u003e0°C to 50°C\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eStorage Conditions - Temperature: \u003c\/b\u003e-40°C to +70°C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating Conditions - Humidity: \u003c\/strong\u003e0-95% RH, non-condensing\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eResolution:\u003c\/strong\u003e 100ppm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNon Linearity:\u003c\/strong\u003e \u0026lt; 1% of FS\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePressure Dependence:\u003c\/strong\u003e 0.13% of reading per mbar @STP\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWarm-up Time:\u003c\/strong\u003e \u0026lt; 30s.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eResponse Time:\u003c\/strong\u003e Flow Rate Dependent\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating Conditions:\u003c\/strong\u003e 0°C to 50°C, 0 to 95% RH, non-condensing\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSensor Life Expectancy:\u003c\/strong\u003e \u0026gt; 15 years\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eElectrical \/ Mechanical\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Input:\u003c\/strong\u003e 3.25 to 5.5V. (3.3V recommended)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePeak Current:\u003c\/strong\u003e 33mA @ 2 readings\/sec.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAverage Current:\u003c\/strong\u003e \u0026lt;12mA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Consumption:\u003c\/strong\u003e 3.5mW @ 2 readings\/sec.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInterface:\u003c\/strong\u003e UART (Serial)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDimensions:\u003c\/strong\u003e 25mm x 40mm x 31mm on PCB (L x W x H)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e 16g sensor, 5.8g board\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eWarranty\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e90 days - See\u003ca title=\"Terms and Conditions\" href=\"https:\/\/www.co2meter.com\/pages\/terms-conditions\"\u003e CO2Meter Terms and Conditions\u003c\/a\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"documents\"\u003e\n\u003ch3\u003eDocuments\u003c\/h3\u003e\n\u003cp\u003e\u003ca title=\"GSS and CO2Meter Product Flyer\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/SprintIR-6S_Data_Sheet_Rev_4.12_-_Updated_Logo.pdf?v=1751034889\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/CO2METER_PDF.png?1094\" alt=\"SprintIR-6S Data Sheet\"\u003e\u003cstrong\u003e\u003cspan style=\"color: red;\"\u003e Data Sheet (pdf)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca title=\"GSS and CO2Meter User Manual and Data Sheet\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/SprintIR-6S_Data_Sheet_Rev_4.12_-_Updated_Logo.pdf?v=1751034889\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/CO2METER_PDF.png?1094\" alt=\"SprintIR-6-S Manual\"\u003e\u003cstrong\u003e\u003cspan style=\"color: red;\"\u003e Sensor Manual (pdf)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/Mechanical_Diagram_-SprintIR-6S-CO2Meter.pdf\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/CO2METER_PDF.png?1094\" alt=\"Mechanical Diagram\"\u003e\u003cstrong\u003e\u003cspan style=\"color: red;\"\u003e Mechanical Diagram (pdf)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/AN015_Using_a_pump_to_sample_gas_Application_Note_Rev_1.1.pdf?v=1651156092\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/CO2METER_PDF.png?1094\" alt=\"\"\u003e\u003cstrong\u003e\u003cspan style=\"color: red;\"\u003e GSS Guide for Sample Draw Pumps (pdf)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/SprintIR-Speed-Comparison.pdf?v=1653495789\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/CO2METER_PDF.png?1094\" alt=\"\"\u003e\u003cstrong\u003e\u003cspan style=\"color: red;\"\u003e SprintIR Speed Comparison Test (pdf)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan style=\"color: red;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/2027_FM_ISO_Certificate.pdf?v=1742814585\"\u003e\u003cimg alt=\"GSS Quality Certification\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/CO2METER_PDF.png?1094\"\u003e\u003cspan style=\"color: rgb(255, 42, 0);\"\u003e Quality Certificate - ISO9001 (pdf)\u003c\/span\u003e\u003c\/a\u003e\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"\/en-ca\/pages\/co2meter-resources\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/CO2METER_PDF.png?1094\" alt=\"\"\u003e\u003cstrong\u003e\u003cspan style=\"color: red;\"\u003e Additional Application Notes\u003c\/span\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"software\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv class=\"accessories\"\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/www.co2meter.com\/products\/gas-sensor-development-kit\" title=\"CO2Meter Gas Sensor Development Kit\"\u003e\u003cstrong\u003eGas Sensor Development Kit\u003c\/strong\u003e (CM-200)\u003c\/a\u003e- designed to provide customers with an easy drop-in solution. Includes our free \u003ca title=\"Gaslab data logging software\" href=\"https:\/\/www.co2meter.com\/pages\/downloads\"\u003eGaslab data logging software\u003c\/a\u003e. Sensor sold separately.\u003c\/p\u003e\n\u003cp\u003e\u003ca title=\"micro-pump kit\" href=\"\/en-ca\/products\/gas-sensor-micro-pump\"\u003e\u003cstrong\u003eMicro-Pump Kit\u003c\/strong\u003e\u003c\/a\u003e\u003cspan\u003e \u003c\/span\u003eincludes all the tools you need to utilize the tube-cap adapters as part of a sampling sensor system.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003ca title=\"nafion tubing\" href=\"\/en-ca\/products\/nafion-gas-sample-drying-tubing\"\u003eNafion Tubing\u003c\/a\u003e \u003c\/strong\u003eis a highly selective, semi-permeable membrane to water vapor. If gases inside Nafion tubing are wetter than gases surrounding the tubing, drying will occur. If the surrounding gases are wetter, humidification will occur.\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"\/en-ca\/products\/gas-sampling-pump\"\u003e\u003cstrong\u003eMicro Gas Sampling Pumps\u003c\/strong\u003e\u003c\/a\u003e provide a constant flow of air across the sensor with a tube cap - perfect for bench-top testing of sensors for closed-loop sampling applications.\u003c\/p\u003e\n\u003c\/div\u003e","brand":"GSS","offers":[{"title":"SPRINTIR-6S-100: SprintIR-6S 100% CO2 Sensor","offer_id":43948874924230,"sku":"SPRINTIR-6S-100","price":318.0,"currency_code":"USD","in_stock":true},{"title":"CM-20800: CO2 100% SprintIR-6S Sensor w\/ MX Board","offer_id":43960919195846,"sku":"CM-20800","price":445.0,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/SprintIR_-6S100_CO2SensorlCO2MeterCM-20801.jpg?v=1753284151"},{"product_id":"sprintir6s-5-co2-smart-sensor","title":"SprintIR®-6S-5 5% CO2 Sensor","description":"\u003cp\u003eThe \u003cspan style=\"color: #115e67;\"\u003e\u003cstrong\u003eSprintIR®-6S-5 5% CO2 Sensor\u003c\/strong\u003e\u003c\/span\u003e (\u003cem\u003eformerly known as GC-0028)\u003c\/em\u003e can take up to 20 readings per second, making it ideal for applications that require individual measurements at high repetition rates or where the CO2 concentration is changing rapidly.\u003c\/p\u003e\n\u003cp\u003eThe sensor is fitted with a standard flow-through adaptor so the CO2 gas can be passed over the optical sensor at high speed.\u003c\/p\u003e\n\u003cp\u003eThe SprintIR®-6S 5% CO2 Sensor uses patented NDIR solid-state LED optical technology enabling the sensor to respond to rapidly changing CO2 without compromising parametric performance.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eNDIR LED sensor measures up to 5% CO2\u003c\/li\u003e\n\u003cli\u003eSolid-state, no moving parts\u003c\/li\u003e\n\u003cli\u003eFast response rate - 20 readings\/second\u003c\/li\u003e\n\u003cli\u003eEasy integration in healthcare, food packaging and scientific applications\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eModels\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSPRINTIR-6S-5\u003c\/strong\u003e – SprintIR-6S 5% CO2 Sensor for integration into high-volume OEM products.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCM-20300: \u003c\/strong\u003eSprintIR-6S 5% CO2 Sensor w\/ MX Board\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCM-20301: \u003c\/strong\u003e- SprintIR-6S 5% CO2 Sensor Development Kit\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCM-200\u003c\/strong\u003e - Wireless Development Kit. Easy to use, simply plug the sensor into the PCB and plug it into your PC via USB. Use our free \u003ca title=\"Gaslab software\" href=\"\/en-ca\/pages\/downloads\"\u003eGasLab® software\u003c\/a\u003e to measure and graph carbon dioxide or use our \u003ca rel=\"noopener\" title=\"Source code on Github\" href=\"https:\/\/github.com\/co2meter-org\/ExampleCode\" target=\"_blank\"\u003elibrary of source code on Github\u003c\/a\u003e to build your own application or for OEM batch testing\/configuration. Order sensors on this page, then \u003ca title=\"Gas Sensor Development Kit\" href=\"https:\/\/www.co2meter.com\/products\/gas-sensor-development-kit\"\u003eorder the Devkit here\u003c\/a\u003e.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan style=\"color: #286adc;\"\u003e\u003cstrong\u003eWe recommend that all first time users purchase either the CM-20301 or CM-200 Development Kit for fastest and easiest results.\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cdiv class=\"specifications\"\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCO2 Sensing Method:\u003c\/strong\u003e Non-dispersive infrared (NDIR) absorption\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSample Method:\u003c\/strong\u003e Solid-state LED NDIR Diffusion\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMeasurement Range:\u003c\/strong\u003e 0-5%\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAccuracy:\u003c\/strong\u003e ±70 ppm +\/- 5% of reading @ STP\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAccuracy @ 100% Range:\u003c\/strong\u003e ±300 ppm +\/-5% of reading @ STP\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTime to 1st Reading: \u003c\/strong\u003e\u0026lt;0.5 Seconds\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating Conditions - Temperature: \u003c\/strong\u003e0°C to 50°C \u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStorage Conditions - Temperature: \u003c\/strong\u003e-40°C to +70°C\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating Conditions - Humidity: \u003c\/strong\u003e0-95% RH, non-condensing\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eResolution:\u003c\/strong\u003e 10ppm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNon Linearity:\u003c\/strong\u003e \u0026lt; 1% of FS\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePressure Dependence:\u003c\/strong\u003e 0.13% of reading per mbar @STP\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWarm-up Time:\u003c\/strong\u003e \u0026lt; 30s.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eResponse Time:\u003c\/strong\u003e Flow Rate Dependent\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eReadings per Second: \u003c\/strong\u003e20\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating Conditions:\u003c\/strong\u003e 0°C to 50°C, 0 to 95% RH, non-condensing\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eElectrical \/ Mechanical\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Input:\u003c\/strong\u003e 3.25 to 5.5V. (3.3V recommended)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePeak Current:\u003c\/strong\u003e 33mA @ 2 readings\/sec\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAverage Current:\u003c\/strong\u003e \u0026lt;12mA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Consumption:\u003c\/strong\u003e 3.5mW @ 2 readings\/sec.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSupply Voltage: \u003c\/strong\u003e3.25V - 5.5V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInterface:\u003c\/strong\u003e UART \u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDimensions:\u003c\/strong\u003e 25mm x 40mm x 31mm on PCB (L x W x H)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e 16g sensor, 5.8g board\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eWarranty\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e90 days - See\u003ca title=\"Terms and Conditions\" href=\"https:\/\/www.co2meter.com\/pages\/terms-conditions\"\u003e CO2Meter Terms and Conditions\u003c\/a\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"documents\"\u003e\n\u003ch3\u003eDocuments\u003c\/h3\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/SprintIR-6S_Data_Sheet_Rev_4.12_-_Updated_Logo.pdf?v=1751034889\" title=\"GSS and CO2Meter Product Flyer\"\u003e\u003cimg alt=\"MinIR Manual\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/CO2METER_PDF.png?1094\"\u003e\u003cstrong\u003e\u003cspan style=\"color: red;\"\u003e Data Sheet (pdf)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/Mechanical_Diagram_-SprintIR-6S-CO2Meter.pdf\"\u003e\u003cimg alt=\"Mechanical Diagram\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/CO2METER_PDF.png?1094\"\u003e\u003cstrong\u003e\u003cspan style=\"color: red;\"\u003e Mechanical Diagram (pdf)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/AN015_Using_a_pump_to_sample_gas_Application_Note_Rev_1.1.pdf?v=1651156092\"\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/CO2METER_PDF.png?1094\"\u003e\u003cstrong\u003e\u003cspan style=\"color: red;\"\u003e GSS Guide for Sample Draw Pumps (pdf)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan style=\"color: red;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/2027_FM_ISO_Certificate.pdf?v=1742814585\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/CO2METER_PDF.png?1094\" alt=\"GSS Quality Certification\"\u003e\u003cspan style=\"color: rgb(255, 42, 0);\"\u003e Quality Certificate - ISO9001 (pdf)\u003c\/span\u003e\u003c\/a\u003e\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/SprintIR-Speed-Comparison.pdf?v=1653495789\"\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/CO2METER_PDF.png?1094\"\u003e\u003cstrong\u003e\u003cspan style=\"color: red;\"\u003e SprintIR Speed Comparison Test (pdf)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"\/en-ca\/pages\/co2meter-resources\"\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/CO2METER_PDF.png?1094\"\u003e\u003cstrong\u003e\u003cspan style=\"color: red;\"\u003e Additional Application Notes\u003c\/span\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"software\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv class=\"accessories\"\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/www.co2meter.com\/products\/gas-sensor-development-kit\" title=\"CO2Meter Gas Sensor Development Kit\"\u003e\u003cstrong\u003eGas Sensor Development Kit\u003c\/strong\u003e (CM-200)\u003c\/a\u003e- designed to provide customers with an easy drop-in solution. Includes our free \u003ca title=\"Gaslab data logging software\" href=\"https:\/\/www.co2meter.com\/pages\/downloads\"\u003eGaslab data logging software\u003c\/a\u003e. Sensor sold separately.\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"\/en-ca\/products\/gas-sensor-micro-pump\" title=\"micro-pump kit\"\u003e\u003cstrong\u003eMicro-Pump Kit\u003c\/strong\u003e\u003c\/a\u003e includes all the tools you need to utilize the tube-cap adapters as part of a sampling sensor system.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003ca href=\"\/en-ca\/products\/nafion-gas-sample-drying-tubing\" title=\"nafion tubing\"\u003eNafion Tubing\u003c\/a\u003e \u003c\/strong\u003eis a highly selective, semi-permeable membrane to water vapor. If gases inside Nafion tubing are wetter than gases surrounding the tubing, drying will occur. If the surrounding gases are wetter, humidification will occur.\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"\/en-ca\/products\/gas-sampling-pump\"\u003e\u003cstrong\u003eMicro Gas Sampling Pumps\u003c\/strong\u003e\u003c\/a\u003e provide a constant flow of air across the sensor with a tube cap - perfect for bench-top testing of sensors for closed-loop sampling applications.\u003c\/p\u003e\n\u003c\/div\u003e","brand":"GSS","offers":[{"title":"SPRINTIR-6S-5: SprintIR 6S 5% CO2 Sensor","offer_id":43948866207942,"sku":"SPRINTIR-6S-5","price":318.0,"currency_code":"USD","in_stock":true},{"title":"CM-20300: CO2 5% SPRINTIR 6S Sensor w\/ Board","offer_id":43961009504454,"sku":"CM-20300","price":494.0,"currency_code":"USD","in_stock":false},{"title":"CM-20301: SprintIR-6S 5% CO2 Sensor Devkit","offer_id":43948868468934,"sku":"CM-20301","price":549.0,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/SprintIR_-6S5_CO2SensorlCO2Meter.jpg?v=1753284149"},{"product_id":"sprintir6s-20-co2-smart-sensor","title":"SprintIR®-6S-20 20% CO2 Sensor","description":"\u003cp\u003eThe \u003cspan style=\"color: #115e67;\"\u003e\u003cstrong\u003eSprintIR®-6S-20 20% CO2 Sensor\u003c\/strong\u003e\u003c\/span\u003e (\u003cem\u003eformerly known as the GC-0029)\u003c\/em\u003e is a high-speed CO2 sensor that can take up to 20 readings per second, making it ideal for applications that require individual measurements at high repetition rates or where the CO2 concentration is changing rapidly.\u003c\/p\u003e\n\u003cp\u003eThe sensor is fitted with a standard flow-through adaptor so the CO2 gas can be passed over the optical sensor at high speed.\u003c\/p\u003e\n\u003cp\u003eThe SprintIR®-6S 20% CO2 Sensor uses patented NDIR solid-state LED optical technology enabling the sensor to respond to rapidly changing CO2 without compromising parametric performance.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eNDIR LED sensor measures up to 20% CO2\u003c\/li\u003e\n\u003cli\u003eFast response rate - 20 readings\/second\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eDigital UART output\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eEasy integration in food packaging or scientific applications\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eModels\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSprintIR®-6S-20 Sensor\u003c\/strong\u003e – for integration into high-volume OEM products.\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eCM-20400 \u003c\/b\u003e– 20% CO2 sensor w\/ MX Board\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eCM-20401\u003c\/b\u003e– 20% CO2 sensor w\/ Development Kit to build on to your own application, further test and configure\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSensor Development Kit\u003c\/strong\u003e (CM-200) - Easy to use, simply plug the sensor into the PCB and plug it into your PC via USB. Use our free \u003ca href=\"\/en-ca\/pages\/downloads\" title=\"Gaslab software\"\u003eGasLab® software\u003c\/a\u003e to measure and graph carbon dioxide or use our \u003ca href=\"https:\/\/github.com\/co2meter-org\/ExampleCode\" title=\"Source code on Github\" rel=\"noopener\" target=\"_blank\"\u003elibrary of source code on Github\u003c\/a\u003e to build your own application or for OEM batch testing\/configuration. Order sensors on this page, then \u003ca href=\"https:\/\/www.co2meter.com\/products\/gas-sensor-development-kit\" title=\"Gas Sensor Development Kit\"\u003eorder the Devkit here\u003c\/a\u003e.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan style=\"color: #286adc;\"\u003e\u003cstrong\u003eWe recommend that all first time users purchase both this sensor and the CM-200 Development Kit for fastest and easiest results.\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cdiv class=\"specifications\"\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCO2 Sensing Method:\u003c\/strong\u003e Non-dispersive infrared (NDIR) absorption\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSample Method:\u003c\/strong\u003e Solid-state LED NDIR Diffusion\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMeasurement Range:\u003c\/strong\u003e 0-20%\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAccuracy:\u003c\/strong\u003e ±70 ppm +\/- 5% of reading @ STP\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTime to 1st Reading: \u003c\/strong\u003e\u0026lt;0.5 Seconds\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAccuracy @ 100% Range:\u003c\/strong\u003e ±300 ppm +\/-5% of reading @ STP\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating Conditions - Temperature: \u003c\/strong\u003e0°C to 50°C \u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eStorage Conditions - Temperature: \u003c\/b\u003e-40°C to +70°C\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eOperating Conditions - Humidity: \u003c\/b\u003e0-95% RH, non-condensing\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eResolution:\u003c\/strong\u003e 10 ppm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNon Linearity:\u003c\/strong\u003e \u0026lt; 1% of FS\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePressure Dependence:\u003c\/strong\u003e 0.13% of reading per mbar @STP\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWarm-up Time:\u003c\/strong\u003e \u0026lt; 30s.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eResponse Time:\u003c\/strong\u003e Flow Rate Dependent\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating Conditions:\u003c\/strong\u003e 0°C to 50°C, 0 to 95% RH, non-condensing\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSensor Lifespan: \u003c\/strong\u003e\u0026gt; 15 years\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eElectrical \/ Mechanical\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Input:\u003c\/strong\u003e 3.25 to 5.5V. (3.3V recommended)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePeak Current:\u003c\/strong\u003e 33mA @ 2 readings\/sec.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAverage Current:\u003c\/strong\u003e \u0026lt;12mA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Consumption:\u003c\/strong\u003e 3.5mW @ 2 readings\/sec.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInterface:\u003c\/strong\u003e UART (Serial)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDimensions:\u003c\/strong\u003e 25mm x 40mm x 31mm on PCB (LxWxH)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e 16g sensor, 5.8g board\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eWarranty\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e90 days - See\u003ca title=\"Terms and Conditions\" href=\"https:\/\/www.co2meter.com\/pages\/terms-conditions\"\u003e CO2Meter Terms and Conditions\u003c\/a\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"documents\"\u003e\n\u003ch3\u003eDocuments\u003c\/h3\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/SprintIR-6S_Data_Sheet_Rev_4.12_-_Updated_Logo.pdf?v=1751034889\" title=\"GSS and CO2Meter Product Flyer\"\u003e\u003cimg alt=\"SprintIR-6S Data Sheet\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/CO2METER_PDF.png?1094\"\u003e\u003cstrong\u003e\u003cspan style=\"color: red;\"\u003e Data Sheet (pdf)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/Mechanical_Diagram_-SprintIR-6S-CO2Meter.pdf\"\u003e\u003cimg alt=\"Mechanical Diagram\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/CO2METER_PDF.png?1094\"\u003e\u003cstrong\u003e\u003cspan style=\"color: red;\"\u003e Mechanical Diagram (pdf)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/AN015_Using_a_pump_to_sample_gas_Application_Note_Rev_1.1.pdf?v=1651156092\"\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/CO2METER_PDF.png?1094\"\u003e\u003cstrong\u003e\u003cspan style=\"color: red;\"\u003e GSS Guide for Sample Draw Pumps (pdf)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/SprintIR-Speed-Comparison.pdf?v=1653495789\"\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/CO2METER_PDF.png?1094\"\u003e\u003cstrong\u003e\u003cspan style=\"color: red;\"\u003e SprintIR Speed Comparison Test (pdf)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan style=\"color: red;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/2027_FM_ISO_Certificate.pdf?v=1742814585\"\u003e\u003cimg alt=\"GSS Quality Certification\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/CO2METER_PDF.png?1094\"\u003e\u003cspan style=\"color: rgb(255, 42, 0);\"\u003e Quality Certificate - ISO9001 (pdf)\u003c\/span\u003e\u003c\/a\u003e\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"\/en-ca\/pages\/co2meter-resources\"\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/CO2METER_PDF.png?1094\"\u003e\u003cstrong\u003e\u003cspan style=\"color: red;\"\u003e Additional Application Notes\u003c\/span\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"software\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv class=\"accessories\"\u003e\n\u003cp\u003e\u003ca title=\"CO2Meter Gas Sensor Development Kit\" href=\"https:\/\/www.co2meter.com\/products\/gas-sensor-development-kit\"\u003e\u003cstrong\u003eGas Sensor Development Kit\u003c\/strong\u003e (CM-200)\u003c\/a\u003e- designed to provide customers with an easy drop-in solution. Includes our free \u003ca href=\"https:\/\/www.co2meter.com\/pages\/downloads\" title=\"Gaslab data logging software\"\u003eGaslab data logging software\u003c\/a\u003e. Sensor sold separately.\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"\/en-ca\/products\/gas-sensor-micro-pump\" title=\"micro-pump kit\"\u003e\u003cstrong\u003eMicro-Pump Kit\u003c\/strong\u003e\u003c\/a\u003e includes all the tools you need to utilize the tube-cap adapters as part of a sampling sensor system.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003ca href=\"\/en-ca\/products\/nafion-gas-sample-drying-tubing\" title=\"nafion tubing\"\u003eNafion Tubing\u003c\/a\u003e \u003c\/strong\u003eis a highly selective, semi-permeable membrane to water vapor. If gases inside Nafion tubing are wetter than gases surrounding the tubing, drying will occur. If the surrounding gases are wetter, humidification will occur.\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"\/en-ca\/products\/gas-sampling-pump\"\u003e\u003cstrong\u003eMicro Gas Sampling Pumps\u003c\/strong\u003e\u003c\/a\u003e provide a constant flow of air across the sensor with a tube cap - perfect for bench-top testing of sensors for closed-loop sampling applications.\u003c\/p\u003e\n\u003c\/div\u003e","brand":"GSS","offers":[{"title":"SPRINTIR-6S-20: 20% CO2 Sensor Only","offer_id":43960913854662,"sku":"SPRINTIR-6S-20","price":318.0,"currency_code":"USD","in_stock":true},{"title":"CM-20400: 20% CO2 Sensor w\/ MX Board","offer_id":43960913887430,"sku":"CM-20400","price":494.0,"currency_code":"USD","in_stock":false},{"title":"CM-20401: 20% CO2 Sensor Development Kit","offer_id":43960913920198,"sku":"CM-20401","price":549.0,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/SprintIR_-6S20_CO2SensorlCO2Meter.jpg?v=1753284148"},{"product_id":"figaro-5000ppm-co2-sensor","title":"Figaro 5,000ppm CO2 Sensor","description":"\u003cp\u003eThe \u003cspan style=\"color: #115e67;\"\u003e\u003cstrong\u003eFigaro 5,000ppm CO2 sensor\u003c\/strong\u003e\u003c\/span\u003e is designed to provide up to 5,000pm measurement for use in ventilation, HVAC, and indoor air quality applications.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eHigh Accuracy and Low Power Consumption\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eIncludes both UART and I2C digital interface\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eEasy integration into OEM products\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eAbsolute measurement via dual sensors\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eModels\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eFG-010 Sensor Only\u003c\/strong\u003e – for integration into high-volume OEM products.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCM-20121 Development Kit\u003c\/strong\u003e – Easy to use, simply plug the sensor module into your PC via USB. Use our free GasLab® software to measure and graph carbon dioxide or for data logging.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv class=\"specifications\"\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCO2 Sensing Method:\u003c\/strong\u003e Non-dispersive infrared (NDIR)\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eDiffusion method\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMeasurement Range:\u003c\/strong\u003e 300-5,000ppm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMeasurement Interval:\u003c\/strong\u003e 2 seconds\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAccuracy:\u003c\/strong\u003e ± (50 ppm + 3% of reading) @ STP\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePressure Dependence:\u003c\/strong\u003e 1% of reading per kPa @STP\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eResponse Time (T90):\u003c\/strong\u003e 2 minutes (diffusion)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating Conditions:\u003c\/strong\u003e 0°C to 50°C, 0 to 85% RH, non-condensing\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStorage Conditions:\u003c\/strong\u003e -30°C to 70°C, ~85% RH, non-condensing\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eElectrical \/ Mechanical\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Input:\u003c\/strong\u003e 4.75 to 5.25VDC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePeak Current:\u003c\/strong\u003e 60mA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAverage Current:\u003c\/strong\u003e 10mA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInterface:\u003c\/strong\u003e UART (Serial), I2C or Analog PWM\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDimensions:\u003c\/strong\u003e 32 x 17 x 7.4mm (L x W x H)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e 3g\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eWarranty\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e90 days - See CO2Meter Terms and Conditions.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"documents\"\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/DS_FG_010_Revised8.pdf?v=1652982972\"\u003e\u003cimg alt=\"Data Sheet\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/CO2METER_PDF.png?1093\"\u003e\u003cstrong\u003e\u003cspan style=\"color: red;\"\u003e Data Sheet (pdf)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/Manual_FG_010_Revised8.pdf?v=1652983004\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/CO2METER_PDF.png?1093\" alt=\"MinIR Manual\"\u003e\u003cstrong\u003e\u003cspan style=\"color: red;\"\u003e Manual (pdf)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"software\"\u003e\n\u003ch3\u003eFree Easy-to-use GasLab® Software\u003c\/h3\u003e\n\u003cp\u003eThis device uses GasLab® software for setup, calibration, data logging, and real-time data analysis. GasLab® makes it easy to export data into a .CSV file that can be imported into any industry-standard software or spreadsheet. GasLab® runs on Windows XP or higher, and is free to use with our products.\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"http:\/\/www.co2meter.com\/pages\/downloads\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/download-drivers.gif?1253980035\" alt=\"Download Latest Software Here\"\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003ch3\u003eAccessories\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003ca title=\"View the Probe Enclosure for Development Kits\" href=\"https:\/\/www.co2meter.com\/collections\/accessories\/products\/probe-enclosure-development-kit\" target=\"_blank\"\u003eProbe Enclosure for Development Kits and Hydrophobic Filter Option\u003c\/a\u003e \u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Figaro","offers":[{"title":"Figaro 5,000ppm CO2 Sensor","offer_id":771075047444,"sku":"FG-010","price":139.0,"currency_code":"USD","in_stock":false},{"title":"Figaro 5,000ppm CO2 DevKit","offer_id":771075014676,"sku":"CM-20121","price":149.0,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/FG-010Figaro5000ppmCO2Sensor.jpg?v=1753284147"},{"product_id":"cozir-wr-5-percent-co2-sensor","title":"ExplorIR®-W 5% CO2 Sensor","description":"\u003cp\u003eThe \u003cspan style=\"color: #115e67;\"\u003e\u003cstrong\u003eExplorIR®-W\u003c\/strong\u003e\u003c\/span\u003e \u003cspan\u003e(formerly known as CozIR Wide Range) \u003c\/span\u003eis a low power, high performance CO2 sensor that measures 5% CO2 in battery powered and portable alarm monitoring applications.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e0-5% CO2 Measurement\u003c\/li\u003e\n\u003cli\u003eDurable, low power consumption\u003c\/li\u003e\n\u003cli\u003eIndustry standard serial communication\u003c\/li\u003e\n\u003cli\u003eIdeal for battery powered applications, or harsh\/rugged environments\u003c\/li\u003e\n\u003cli\u003eSimple to install, pre-calibrated and ready-to-use\u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eModels\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eGC-0015 ExplorIR®-W 5% CO2 Sensor Only\u003c\/strong\u003e - \u003cspan\u003efor integration into high-volume OEM products.\u003c\/span\u003e \u003ca href=\"https:\/\/www.co2meter.com\/pages\/rfq\" target=\"_blank\"\u003eContact us directly\u003c\/a\u003e for wholesale pricing on large quantities of this sensor.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCM-0124 ExplorIR®-W 5% CO2 Sensor Development Kit \u003c\/strong\u003e- \u003cspan\u003eEasy to use, simply plug the sensor module into your PC via the included serial UART to USB cable. Use our free GasLab® software to measure and graph carbon dioxide, to configure the sensor or for data logging.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv class=\"specifications\"\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMeasurement Range:\u003c\/strong\u003e 0-5% CO2\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSensing Method:\u003c\/strong\u003e NDIR with Gold-plated optics\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSample Method:\u003c\/strong\u003e Diffusion (default) or sampling with optional tube adapter\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAccuracy:\u003c\/strong\u003e ±70 ppm ± 5% of reading\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eResolution:\u003c\/strong\u003e 10ppm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSample Rate:\u003c\/strong\u003e 500 ms (2 Hz) measurement interval\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eResponse Time Filter:\u003c\/strong\u003e 4 secs to 2 mins (user configurable)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSerial communications:\u003c\/strong\u003e 9600\/8\/1\/N\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWarm-up Time:\u003c\/strong\u003e \u0026lt; 10s\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating Conditions:\u003c\/strong\u003e 0°C to 50°C, 950 mBar to 10 Bar\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e8g\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSensor Life Expectancy:\u003c\/strong\u003e \u0026gt; 15 years\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eElectrical\/Mechanical\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Input:\u003c\/strong\u003e 3.3 ±0.1 volt  DC \u0026lt; 3.5 mW\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePeak current:\u003c\/strong\u003e 33mA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDevkit includes 6’ (1.8m) \u003cspan class=\"caps\"\u003eUSB\u003c\/span\u003e cable (non-standard)\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eWarranty\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e90 days - See \u003ca href=\"https:\/\/www.co2meter.com\/pages\/terms-conditions\" title=\"CO2Meter Terms and Conditions\"\u003e\u003cstrong\u003eCO2Meter Terms and Conditions.\u003c\/strong\u003e\u003c\/a\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"documents\"\u003e\n\u003ch3\u003eDocuments\u003c\/h3\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/Datasheet_ExplorIR_W_CO2Meter_4_15-compressed.pdf\"\u003e\u003cimg alt=\"Datasheet\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/CO2METER_PDF.png?1093\"\u003e\u003cstrong\u003e\u003cspan style=\"color: red;\"\u003e Data Sheet (pdf)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/Manual_GC_0024_0025_0026_Revised8.pdf?v=1679587743\"\u003e\u003cimg alt=\"COZIR Manual\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/CO2METER_PDF.png?1093\"\u003e\u003cstrong\u003e\u003cspan style=\"color: red;\"\u003e Manual (pdf)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/AN145-sensor-development-kit-quick-start-guide.pdf?v=1650749355\"\u003e\u003cimg alt=\"Quick Start Guide\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/CO2METER_PDF.png?1093\"\u003e\u003cstrong\u003e\u003cspan style=\"color: red;\"\u003e Devkit Quick Start Guide (pdf)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/CO2Meter-GSS-White-Paper-Incubation.pdf\"\u003e\u003cimg alt=\"Incubation White Paper\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/CO2METER_PDF.png?1094\"\u003e\u003cstrong\u003e\u003cspan style=\"color: red;\"\u003e Incubation White Paper (pdf)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/Mechanical_Diagram_-ExplorIR-W-CO2Meter.pdf\"\u003e\u003cimg alt=\"Dimensional Drawings\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/CO2METER_PDF.png?1093\"\u003e\u003cstrong\u003e\u003cspan style=\"color: red;\"\u003e Dimensional Drawings (pdf)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/AN_128_GC_15_16_7_5_Revised8.pdf?v=1652981868\"\u003e\u003cimg alt=\"Documentation\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/CO2METER_PDF.png?1093\"\u003e\u003cstrong\u003e\u003cspan style=\"color: red;\"\u003e Arduino Sample Code (pdf)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan style=\"color: red;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/2027_FM_ISO_Certificate.pdf?v=1742814585\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/CO2METER_PDF.png?1094\" alt=\"GSS Quality Certification\"\u003e\u003cspan style=\"color: rgb(255, 42, 0);\"\u003e Quality Certificate - ISO9001 (pdf)\u003c\/span\u003e\u003c\/a\u003e\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/AN141-Labview-examples.zip?v=1647477681\"\u003e\u003cimg alt=\"Documentation\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/assets\/zip.gif\"\u003e\u003cstrong\u003e\u003cspan style=\"color: red;\"\u003e Labview Examples for COZIR CO2 Sensors (zip)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cbr\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"software\"\u003e\n\u003ch3\u003eFree Easy-to-use GasLab™ Software\u003c\/h3\u003e\n\u003cp\u003eThis device uses GasLab® software for setup, calibration, data logging, and real-time data analysis. GasLab® makes it easy to export data into a .CSV file that can be imported into any industry-standard software or spreadsheet. GasLab® runs on Windows XP or higher, and free to use with our products.\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"http:\/\/www.co2meter.com\/pages\/downloads\"\u003e\u003cimg alt=\"Download Latest Software Here\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/download-drivers.gif?1253980035\"\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"accessories\"\u003e\n\u003ch3\u003eAccessories\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/www.co2meter.com\/collections\/accessories\/products\/probe-enclosure-development-kit\" title=\"View the Probe Enclosure for Development Kits\" target=\"_blank\"\u003eProbe Enclosure for Development Kits and Hydrophobic Filter Option\u003c\/a\u003e \u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e\u003ca href=\"https:\/\/www.co2meter.com\/products\/co2meter-sensor-tube-cap\" title=\"Sensor Tube Cap Adapter\" target=\"_blank\"\u003eTC1-5 Tube Cap Adapter\u003c\/a\u003e - easily converts a wide range of gas sensors from diffusion applications to sampling. \u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e","brand":"GSS","offers":[{"title":"GC-0015: ExplorIR®-W 5% CO2 Sensor","offer_id":828167127060,"sku":"GC-0015","price":142.0,"currency_code":"USD","in_stock":false},{"title":"CM-0124: ExplorIR®-W 5% CO2 Sensor Development Kit","offer_id":828167159828,"sku":"CM-0124","price":197.0,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/products\/explorir-w-5-co2-sensor-291992.jpg?v=1753284143"},{"product_id":"cozir-ambient-10000-ppm-co2-sensor","title":"CozIR®-A 10,000 ppm CO2 Sensor","description":"\u003cp\u003e\u003cspan\u003eThe \u003cstrong\u003eCozIR®-A \u003c\/strong\u003e\u003c\/span\u003e\u003cspan\u003e\u003cstrong\u003e10,000 ppm (1%) CO2 sensor\u003c\/strong\u003e is designed to monitor carbon dioxide levels indoors. It is ideal for monitoring CO2 in buildings, schools, offices or anywhere indoor air quality is important for personal comfort of the occupants.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eFeatures\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eLow Power Consumption\u003c\/li\u003e\n\u003cli\u003e2 measurements per second\u003c\/li\u003e\n\u003cli\u003eIndustry-Standard Serial Communication\u003c\/li\u003e\n\u003cli\u003eSensor life expectancy \u0026gt; 15 years\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eModels\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eGC-0012 CozIR®-A 10,000 ppm CO2 Sensor\u003c\/strong\u003e - for integration into high-volume OEM products. \u003ca href=\"\/en-ca\/pages\/rfq\" target=\"_blank\"\u003eContact us directly\u003c\/a\u003e for wholesale pricing on large quantities of this sensor.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCM-0120 CozIR®-A Development Kit\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e-\u003cspan\u003e \u003c\/span\u003e\u003cspan\u003eEasy to use, simply plug the sensor module into your PC via USB. Use our free GasLab® software to measure and graph carbon dioxide, to configure the sensor or for data logging.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eCM-0047 Tube Cap Adapter\u003c\/strong\u003e - \u003cstrong\u003eThis adapter has been discontinued.\u003c\/strong\u003e If you are looking for a tube cap adapter, please contact us directly at \u003cstrong\u003eSales@CO2Meter.com\u003c\/strong\u003e - you MUST provide us with which sensor you have purchased for proper solution.\u003c\/span\u003e\u003c\/p\u003e\n\u003cdiv class=\"specifications\"\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eSensing Method: NDIR with Gold-plated optics\u003c\/li\u003e\n\u003cli\u003eSample Method: Diffusion (Optional Sampling with Tube Cap)\u003c\/li\u003e\n\u003cli\u003eMeasurement Range: 0-10,000 ppm (parts per million)\u003c\/li\u003e\n\u003cli\u003eMeasurement Rate: 0.5 sec \/ measurement\u003c\/li\u003e\n\u003cli\u003eAccuracy: ±50 ppm ± 3% of reading\u003c\/li\u003e\n\u003cli\u003eResolution: 1ppm\u003c\/li\u003e\n\u003cli\u003ePressure Dependence: 0.13% of reading per mm Hg\u003c\/li\u003e\n\u003cli\u003eNoise measurement: \u0026lt; 10 ppm\u003c\/li\u003e\n\u003cli\u003eAuto Calibration Default (can be changed in software)\u003c\/li\u003e\n\u003cli\u003eSerial communication 9600\/ 8\/ 1\/ n\u003c\/li\u003e\n\u003cli\u003eAnalog voltage output proportional to CO2 concentration\u003c\/li\u003e\n\u003cli\u003eSensor Life Expectancy: \u0026gt; 15 years\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eGeneral Performance\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eWarm-up Time: \u0026lt; 10 seconds (1.2s to first reading)\u003c\/li\u003e\n\u003cli\u003eOperating Conditions: 0°C to 50°C, 0-95% RH, 500 mbar to 40 bar\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eElectrical\/Mechanical\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003ePower Input: 3.3-5.5VDC (3.3V recommended)\u003c\/li\u003e\n\u003cli\u003eAverage Power Requirements: \u0026lt; 1.5mA @ 3.3V\u003c\/li\u003e\n\u003cli\u003ePeak current: 33mA\u003c\/li\u003e\n\u003cli\u003eWeight 20 grams\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eWarranty\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e90 days - See CO2Meter Terms and Conditions\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"documents\"\u003e\n\u003ch3\u003eDocuments\u003c\/h3\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/CozIR-A_Data_Sheet_Rev_4.11_-_Updated_Logo.pdf?v=1751374850\" title=\"CozIR-A_Data_Sheet\"\u003e\u003cimg alt=\"Datasheet\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/CO2METER_PDF.png?1093\"\u003e\u003cstrong\u003e\u003cspan style=\"color: red;\"\u003e Data Sheet (pdf) \u003c\/span\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/Manual_GC_0024_0025_0026_Revised8.pdf?v=1650749301\"\u003e\u003cimg alt=\"COZIR Manual\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/CO2METER_PDF.png?1093\"\u003e\u003cstrong\u003e\u003cspan style=\"color: red;\"\u003e Manual (pdf)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/CO2Meter-GSS-Cozir-A-User-Guide-Rev_4.1.pdf\"\u003e\u003cimg alt=\"COZIR GSS User Guide\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/CO2METER_PDF.png?1093\"\u003e\u003cstrong\u003e\u003cspan style=\"color: red;\"\u003e GSS COZIR A User Guide (pdf)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/AN145-sensor-development-kit-quick-start-guide.pdf?v=1650749355\"\u003e\u003cimg alt=\"Quick Start Guide\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/CO2METER_PDF.png?1093\"\u003e\u003cstrong\u003e\u003cspan style=\"color: red;\"\u003e DevKit Quick Start Guide (pdf)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"http:\/\/www.co2meters.com\/Documentation\/Manuals\/Manual-GSS-Sensors.pdf\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/Mechanical_Diagram_-_CozIR-A_Cased-CO2Meter.pdf\"\u003e\u003cimg alt=\"Dimensional Sheet\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/CO2METER_PDF.png?1093\"\u003e\u003cstrong\u003e\u003cspan style=\"color: red;\"\u003e Dimensional Drawings (pdf)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan style=\"color: red;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/2027_FM_ISO_Certificate.pdf?v=1742814585\"\u003e\u003cimg alt=\"GSS Quality Certification\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/CO2METER_PDF.png?1094\"\u003e\u003cspan style=\"color: rgb(255, 42, 0);\"\u003e Quality Certificate - ISO9001 (pdf)\u003c\/span\u003e\u003c\/a\u003e\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/Mechanical_Diagram_-_CozIR-A_Cased-CO2Meter.pdf\"\u003e \u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/CO2METER_PDF.png?1093\" alt=\"Dimensional Sheet\"\u003e\u003c\/a\u003e \u003cspan style=\"color: #ff2a00;\"\u003e\u003ca title=\"Sensor Evaluation Kit\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/CO2_Sensor_Evaluation_Kit_User_Guide_9_June_2021_Rev_1.4.pdf?v=1640009264\" style=\"color: #ff2a00;\"\u003eSensor Evaluation\u003c\/a\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cbr\u003eThis device uses GasLab® software for setup, calibration, data logging, and real-time data analysis. GasLab® makes it easy to export data into a .CSV file that can be imported into any industry-standard software or spreadsheet. GasLab® runs on Windows XP or higher, and free to use with our products\u003c\/div\u003e\n\u003cdiv class=\"software\"\u003e\n\u003cp\u003e\u003ca href=\"\/en-ca\/pages\/downloads\"\u003e\u003cimg alt=\"Download Latest Software Here\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/download-drivers.gif?1253980035\"\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"accessories\"\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"\/en-ca\/products\/gas-sensor-micro-pump\"\u003eSample Draw Pump Kit\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e","brand":"GSS","offers":[{"title":"GC-0012: CozIR®-A 10,000ppm  CO2 Sensor","offer_id":840094580756,"sku":"GC-0012","price":142.0,"currency_code":"USD","in_stock":true},{"title":"CM-0120: CozIR®-A 10,000ppm Development Kit","offer_id":840094613524,"sku":"CM-0120","price":175.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/products\/cozir-a-10000-ppm-co2-sensor-110161.jpg?v=1753284141"},{"product_id":"cozir-10000-ppm-co2-temperature-humidity-sensor","title":"CozIR®-A 10,000ppm CO2 + RH\/T Sensor","description":"\u003cp\u003e\u003cspan\u003eThe \u003cstrong\u003eCozIR®-A 10,000 ppm CO2 + temperature and % relative humidity sensor\u003c\/strong\u003e is designed to monitor carbon dioxide levels indoors. It is ideal for monitoring CO2 in buildings, schools, offices, or anywhere indoor air quality is important for the personal comfort of the occupants.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eFeatures\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eCO2, Temperature \u0026amp; %RH in a Single Sensor\u003c\/li\u003e\n\u003cli\u003eLow Power Consumption\u003c\/li\u003e\n\u003cli\u003e2 Measurements Per Second\u003c\/li\u003e\n\u003cli\u003eSensor life expectancy \u0026gt; 15 years\u003c\/li\u003e\n\u003cli\u003eIndustry-Standard Serial Communication\u003cb\u003e\u003cbr\u003e\u003c\/b\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eModels\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eGC-0022 CozIR®-A 10,000 ppm CO2 + RH\/T Sensor\u003c\/strong\u003e - \u003cspan\u003efor integration into high-volume OEM products.\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e\u003ca href=\"https:\/\/www.co2meter.com\/pages\/rfq\" target=\"_blank\"\u003eContact us directly\u003c\/a\u003e\u003cspan\u003e \u003c\/span\u003efor wholesale pricing on large quantities of this sensor.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCM-0199 CozIR®-A 10,000 ppm CO2 + RH\/T Development Kit\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e-\u003cspan\u003e \u003c\/span\u003e\u003cspan\u003eEasy to use, simply plug the sensor module into your PC via USB. Use our free GasLab® software to measure and graph carbon dioxide, to configure the sensor, or for data logging.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCM-0047 Tube Cap Adapter\u003c\/strong\u003e\u003cspan\u003e - \u003c\/span\u003e\u003cstrong\u003eThis adapter has been discontinued.\u003c\/strong\u003e\u003cspan\u003e I\u003c\/span\u003e\u003cspan\u003ef you are looking for a tube cap adapter\u003c\/span\u003e\u003cspan\u003e, please contact us directly at \u003c\/span\u003e\u003cstrong\u003eSales@CO2Meter.com\u003c\/strong\u003e\u003cspan\u003e. You MUST provide us with which sensor you have purchased for a proper \u003c\/span\u003e\u003cspan\u003esolution.\u003c\/span\u003e\u003c\/p\u003e\n\u003cdiv class=\"specifications\"\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eCO2 Sensing Method: NDIR with Gold-plated optics\u003c\/li\u003e\n\u003cli\u003eSample Method: Diffusion (Optional Sampling with Tube Cap)\u003c\/li\u003e\n\u003cli\u003eAuto Calibration Default (can be changed in software)\u003c\/li\u003e\n\u003cli\u003eCO2 Measurement Range: 0-10,000 ppm (parts per million)\u003c\/li\u003e\n\u003cli\u003eCO2 Measurement Rate: 0.5 sec \/ measurement\u003c\/li\u003e\n\u003cli\u003eCO2 Accuracy: ±50 ppm ± 3% of reading\u003c\/li\u003e\n\u003cli\u003eResolution: 1ppm\u003c\/li\u003e\n\u003cli\u003eCO2 Pressure Dependence: 0.13% of reading per mm Hg\u003c\/li\u003e\n\u003cli\u003eCO2 Noise measurement: \u0026lt; 10 ppm\u003c\/li\u003e\n\u003cli\u003eTemperature Sensing Method: Bandgap\u003c\/li\u003e\n\u003cli\u003eTemperature Range: -0 to +55\u003cspan\u003e°C\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eTemperature Accuracy: +\/- 1°C within Range\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003eHumidity Sensing Method: Capacitive\u003c\/li\u003e\n\u003cli\u003eHumidity Range: 0 to 95% RH\u003c\/li\u003e\n\u003cli\u003eHumidity Accuracy: \u003cspan\u003e+\/- 5% \u003c\/span\u003e\u003cspan\u003ewithin Range\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003eSerial communication 9600\/ 8\/ 1\/ n\u003c\/li\u003e\n\u003cli\u003eAnalog output for CO2 concentration\u003c\/li\u003e\n\u003cli\u003eSensor Life\u003cspan\u003e \u003c\/span\u003eExpectancy:\u003cspan\u003e \u003c\/span\u003e\u0026gt; 15 years\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eGeneral Performance\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eWarm-up Time: \u0026lt; 10 seconds (1.2s to first reading)\u003c\/li\u003e\n\u003cli\u003eOperating Conditions: -22°C to 55°C, 0-95% RH, 500 mbar to 40 bar\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eElectrical\/Mechanical\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003ePower Input: 3.3-5.5VDC (3.3V recommended)\u003c\/li\u003e\n\u003cli\u003eAverage Power Requirements: \u0026lt; 1.5mA @ 3.3V\u003c\/li\u003e\n\u003cli\u003ePeak current: 33mA\u003c\/li\u003e\n\u003cli\u003eWeight 20 grams\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eWarranty\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e90 days - See CO2Meter Terms and Conditions\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"documents\"\u003e\n\u003ch3\u003eDocuments\u003c\/h3\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/CozIR-A_Data_Sheet_Rev_4.11_-_Updated_Logo.pdf?v=1751374850\" title=\"CozIR-A_Data_Sheet_Rev_4.11\"\u003e\u003cimg alt=\"Datasheet\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/CO2METER_PDF.png?1093\"\u003e\u003cstrong\u003e\u003cspan style=\"color: red;\"\u003e Data Sheet (pdf) \u003c\/span\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/Manual_GC_0024_0025_0026_Revised8.pdf?v=1650749301\"\u003e\u003cimg alt=\"COZIR Manual\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/CO2METER_PDF.png?1093\"\u003e\u003cstrong\u003e\u003cspan style=\"color: red;\"\u003e Manual (pdf)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/CO2Meter-GSS-Cozir-A-User-Guide-Rev_4.1.pdf\"\u003e\u003cimg alt=\"COZIR GSS User Guide\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/CO2METER_PDF.png?1093\"\u003e\u003cstrong\u003e\u003cspan style=\"color: red;\"\u003e GSS COZIR A User Guide (pdf)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/AN145-sensor-development-kit-quick-start-guide.pdf?v=1650749355\"\u003e\u003cimg alt=\"Quick Start Guide\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/CO2METER_PDF.png?1093\"\u003e\u003cstrong\u003e\u003cspan style=\"color: red;\"\u003e DevKit Quick Start Guide (pdf)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/Mechanical_Diagram_-_CozIR-A_Cased-CO2Meter.pdf\"\u003e\u003cimg alt=\"Dimensional Sheet\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/CO2METER_PDF.png?1093\"\u003e\u003cstrong\u003e\u003cspan style=\"color: red;\"\u003e Dimensional Drawings (pdf)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/2027_FM_ISO_Certificate.pdf?v=1742814585\"\u003e\u003cspan style=\"color: red;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/CO2METER_PDF.png?1094\" alt=\"GSS Quality Certification\"\u003e\u003cspan style=\"color: rgb(255, 42, 0);\"\u003e Quality Certificate - ISO9001 (pdf)\u003c\/span\u003e\u003c\/span\u003e\u003c\/a\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/Mechanical_Diagram_-_CozIR-A_Cased-CO2Meter.pdf\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/CO2METER_PDF.png?1093\" alt=\"Dimensional Sheet\"\u003e\u003c\/a\u003e \u003cspan style=\"color: #ff2a00;\"\u003e\u003ca title=\"Sensor Evaluation Kit\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/CO2_Sensor_Evaluation_Kit_User_Guide_9_June_2021_Rev_1.4.pdf?v=1640009264\" style=\"color: #ff2a00;\"\u003eSensor Evaluation\u003c\/a\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cbr\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"software\"\u003e\n\u003ch4\u003eFree Easy-to-use GasLab™ Software\u003c\/h4\u003e\n\u003cp\u003eThis device uses GasLab® software for setup, calibration, data logging, and real-time data analysis. GasLab® makes it easy to export data into a .CSV file that can be imported into any industry-standard software or spreadsheet. GasLab® runs on Windows XP or higher, and free to use with our products.\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"\/en-ca\/pages\/downloads\"\u003e\u003cimg alt=\"Download Latest Software Here\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/download-drivers.gif?1253980035\"\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"accessories\"\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"\/en-ca\/products\/gas-sensor-micro-pump\"\u003eSample Draw Pump Kit\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e","brand":"GSS","offers":[{"title":"GC-0022: CozIR®-A 10,000ppm CO2 RH\u0026T","offer_id":878558412820,"sku":"GC-0022","price":164.0,"currency_code":"USD","in_stock":true},{"title":"CM-0199: CozIR®-A 10,000ppm CO2 RH\u0026T DevKit","offer_id":878558445588,"sku":"CM-0199","price":186.0,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/products\/cozir-a-10000ppm-co2-rht-sensor-417622.jpg?v=1753284139"},{"product_id":"s8-miniature-5-co2-sensor","title":"004-0-0071 S8 Miniature 5% CO2 Sensor","description":"\u003cp\u003eThe \u003cspan style=\"color: #115e67;\" data-mce-style=\"color: #115e67;\"\u003e\u003cstrong\u003eS8 Miniature 5% CO2 Sensor\u003c\/strong\u003e\u003c\/span\u003e (\u003cem\u003eformerly known as the SE-0037)\u003c\/em\u003e is\u003cem\u003e \u003c\/em\u003edesigned to act like a safety switch for alarm applications where up to 5% CO2 detection is required. This makes it useful for indoor leak detection alarms around cylinders or tanks of compressed CO2. \u003c\/p\u003e\n\u003cp\u003eThis sensor can be ordered with Automatic Background Calibration (ABC) either turned on or off. ABC should only be used if the sensor can record fresh air (400 ppm) on a daily basis.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eCompact footprint, runs only 30mA\u003c\/li\u003e\n\u003cli\u003eLow Power, Small Footprint Design\u003c\/li\u003e\n\u003cli\u003eAutomatic Background Calibration\u003c\/li\u003e\n\u003cli\u003eIndustry-Standard UART Communication\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eModels\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eS8 5% CO2 Sensor ABC Off\u003c\/strong\u003e (004-0-0071)- pinless design for integration into high-volume OEM products.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eS8 Alarm 0-5% CO2 Sensor ABC On \u003c\/strong\u003e(004-0-0017) - pinless design for integration into high-volume OEM products.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eK30 CO2 Sensor Development Kit\u003c\/strong\u003e (CM-0218) - Easy to use, simply plug the sensor module into your PC via USB. Use our free \u003ca title=\"Gaslab Software\" href=\"https:\/\/www.co2meter.com\/pages\/downloads\"\u003eGasLab® software\u003c\/a\u003e to measure and graph carbon dioxide in real time or for data logging.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSensor Development Kit\u003c\/strong\u003e (CM-200) - Easy to use, simply plug the sensor into the PCB and plug it into your PC via USB. Use our free \u003ca href=\"\/en-ca\/pages\/downloads\" title=\"Gaslab software\"\u003eGasLab® software\u003c\/a\u003e to measure and graph carbon dioxide or use our \u003ca href=\"https:\/\/github.com\/co2meter-org\/ExampleCode\" title=\"Source code on Github\" rel=\"noopener\" target=\"_blank\"\u003elibrary of source code on Github\u003c\/a\u003e to build your own application or for OEM batch testing\/configuration. Order sensors on this page, then \u003ca href=\"https:\/\/www.co2meter.com\/products\/gas-sensor-development-kit\" title=\"Gas Sensor Development Kit\"\u003eorder the Devkit here\u003c\/a\u003e.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan style=\"color: #286adc;\" data-mce-style=\"color: #286adc;\"\u003e\u003cstrong\u003eWe recommend that all first-time users purchase either the CM-0218 or CM-200 Development Kit for fastest and easiest results.\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cdiv class=\"specifications\"\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCO2 Measurement:\u003c\/strong\u003e non-dispersive infrared (NDIR)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMeasurement Method:\u003c\/strong\u003e Diffusion\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMeasurement Range:\u003c\/strong\u003e 0-5% (0-50,000ppm)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eResponse time:\u003c\/strong\u003e 90% at 2 minutes\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRate of Measurement:\u003c\/strong\u003e \u003cspan\u003e0.5 Hz (every 2 seconds)\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCO2 Accuracy:\u003c\/strong\u003e ± 200ppm ± 10% of measured value\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAvailable Output:\u003c\/strong\u003e analog\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCommunication Options:\u003c\/strong\u003e UART Modbus\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDimensions:\u003c\/strong\u003e 32.7 × 19.7 × 8 mm (L x W x H)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e 8 grams\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSensor Life Expectancy:\u003c\/strong\u003e \u0026gt;15 years\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaintenance Interval:\u003c\/strong\u003e no maintenance required\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSelf-Diagnostics:\u003c\/strong\u003e complete function check on startup\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eElectrical \/ Mechanical\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Input:\u003c\/strong\u003e 4.5V - 5.25VDC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMax Current:\u003c\/strong\u003e 300 mA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Consumption:\u003c\/strong\u003e 300mA peak, 30mA average\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eWarranty\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e90 days - See\u003ca title=\"Terms and Conditions\" href=\"https:\/\/www.co2meter.com\/pages\/terms-conditions\"\u003e CO2Meter Terms and Conditions.\u003c\/a\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"documents\"\u003e\n\u003ch3\u003eDocuments\u003c\/h3\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/rmtplusstoragesenseair.blob.core.windows.net\/docs\/publicerat\/PSP0113.pdf\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/CO2METER_PDF.png?1094\" alt=\"CO2 Sensor Documention\" title=\"S8 Manual\" target=\"_blank\"\u003e\u003cstrong\u003e\u003cspan style=\"color: red;\"\u003e S8 5% Sensor Manual (pdf)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/rmtplusstoragesenseair.blob.core.windows.net\/docs\/Dev\/publicerat\/TDE2067.pdf\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/CO2METER_PDF.png?1094\" alt=\"CO2 Sensor Documention\" target=\"_blank\"\u003e\u003cstrong\u003e\u003cspan style=\"color: red;\"\u003e Connecting to Modbus Communication Manual (pdf)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/AN_168_SE_0037_Raspberry_Pi_to_SenseAir_Revised8.pdf?v=1653445714\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/CO2METER_PDF.png?1094\" alt=\"CO2 Sensor Documention\"\u003e\u003cstrong\u003e\u003cspan style=\"color: red;\"\u003e Connecting to Raspberry Pi via UART (pdf)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/AN168-S8-raspberry-pi-files.zip?v=1653445941\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/CO2METER_PDF.png?1094\" alt=\"CO2 Sensor Documention\"\u003e\u003cstrong\u003e\u003cspan style=\"color: red;\" data-mce-style=\"color: red;\"\u003e Raspberry Pi Sample Code (ZIP)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/AN162-LP8-sensor-arduino-modbus-uart.pdf?v=1653446032\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/CO2METER_PDF.png?1094\" alt=\"CO2 Sensor Documentation\"\u003e\u003cstrong\u003e\u003cspan style=\"color: red;\" data-mce-style=\"color: red;\"\u003e Connecting to TI CC3200 WIFI via UART (pdf)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/SenseairISO.pdf?v=1613679881\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/CO2METER_PDF.png?1093\" alt=\"Senseair ISO Certification\"\u003e\u003cstrong\u003e\u003cspan style=\"color: red;\" data-mce-style=\"color: red;\"\u003e Senseair ISO Certification (pdf)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"software\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv class=\"accessories\"\u003e\n\u003ch3\u003eAccessories\u003c\/h3\u003e\n\u003cp\u003e\u003ca title=\"CO2Meter Gas Sensor Development Kit\" href=\"https:\/\/www.co2meter.com\/products\/gas-sensor-development-kit\"\u003e\u003cstrong\u003eGas Sensor Development Kit\u003c\/strong\u003e (CM-200)\u003c\/a\u003e- designed to provide customers with an easy drop-in solution. Includes our free \u003ca href=\"https:\/\/www.co2meter.com\/pages\/downloads\" title=\"Gaslab data logging software\"\u003eGaslab data logging software\u003c\/a\u003e. Sensor sold separately.\u003c\/p\u003e\n\u003c\/div\u003e","brand":"Senseair","offers":[{"title":"004-0-0071: S8 5% CO2 Sensor - ABC Off","offer_id":945623400468,"sku":"004-0-0071","price":55.0,"currency_code":"USD","in_stock":true},{"title":"CM-0218: S8 5% CO2 Sensor Development Kit","offer_id":44567317283014,"sku":"CM-0218","price":197.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/004-0-0071004-0-0071S8Miniature5_CO2Sensor_SE-0037.jpg?v=1753284138"},{"product_id":"sprintir-wr-20-pct-co2-sensor","title":"SprintIR®-W 20% CO2 Sensor","description":"\u003cp\u003eThe \u003cspan style=\"color: #115e67;\"\u003e\u003cstrong\u003eSprintIR®-W Carbon Dioxide Sensor\u003c\/strong\u003e\u003c\/span\u003e is one of the fastest (20 measurements per second!), most accurate CO2 sensors on the market. The sensor uses advanced solid-state technology and offers no moving parts, making it ideal for high-speed sensing requirements.\u003c\/p\u003e\n\u003ch2\u003eFeatures\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eHigh-speed sensing: 20 Hz\u003c\/li\u003e\n\u003cli\u003eLow power\/energy consumption: 35 mW\u003c\/li\u003e\n\u003cli\u003eVibration and shock resistant\u003c\/li\u003e\n\u003cli\u003eIntegrates with wireless IoT networks such as Zigbee®, Wi-Fi, LoRa, Bluetooth®, SigFox, and EnOcean\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eModels\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eGC-0017 SprintIR®-W 20% CO2 Sensor\u003c\/strong\u003e - for integration into high-volume OEM products. \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv class=\"specifications\"\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSensing Method:\u003c\/strong\u003e NDIR with Gold-plated optics\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMeasurement range:\u003c\/strong\u003e 20% (200,000ppm) CO2\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSample Method:\u003c\/strong\u003e Diffusion (Tube cap adapter available)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAccuracy:\u003c\/strong\u003e ±70 ppm ± 5% of reading\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eResolution:\u003c\/strong\u003e 10ppm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWarm Up Time:\u003c\/strong\u003e \u0026lt;1 min to operational (\u0026lt; 2 secs to initial reading)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSensor Life Expectancy:\u003c\/strong\u003e \u0026gt; 15 years\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eElectrical\/Mechanical\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Input:\u003c\/strong\u003e 3.2-5.5VDC (3.3V recommended)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePeak current:\u003c\/strong\u003e 100mA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAverage Current:\u003c\/strong\u003e \u0026lt;15mA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e 8 grams (w. tube cap 29 grams)\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eUART Only 9600\/8\/1\/N\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eWarranty\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e90 days - See CO2Meter Terms and Conditions.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"documents\"\u003e\n\u003ch3\u003eDocuments\u003c\/h3\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/SprintIR-W_Data_Sheet_Rev_4.14_-_Updated_Logo.pdf?v=1755008739\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/CO2METER_PDF.png?1094\" alt=\"Datasheet\"\u003e\u003cstrong\u003e\u003cspan style=\"color: red;\"\u003e Data Sheet (pdf)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/SprintIR-W_Data_Sheet_Rev_4.11.pdf?v=1640788790\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/CO2METER_PDF.png?1094\" alt=\"SprintIR manual\"\u003e\u003cstrong\u003e\u003cspan style=\"color: red;\"\u003e Manual (pdf)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/Mechanical_Diagram_-SprintIR-W.pdf?v=1613678435\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/CO2METER_PDF.png?1094\" alt=\"Dimensional Drawing SprintIRW\"\u003e\u003cstrong\u003e\u003cspan style=\"color: red;\"\u003e Dimensional Drawings (pdf)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/2027_FM_ISO_Certificate.pdf?v=1742814585\"\u003e\u003cstrong\u003e\u003cspan style=\"color: red;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/CO2METER_PDF.png?1094\" alt=\"GSS Quality Certification\"\u003e\u003cspan style=\"color: rgb(255, 42, 0);\"\u003e Quality Certificate - ISO9001 (pdf)\u003c\/span\u003e\u003c\/span\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003cbr\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/AN015_Using_a_pump_to_sample_gas_Application_Note_Rev_1.1.pdf?v=1651156092\"\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/CO2METER_PDF.png?1094\"\u003e\u003cstrong\u003e\u003cspan style=\"color: red;\"\u003e GSS Guide for Sample Draw Pumps (pdf)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"\/en-ca\/pages\/co2meter-resources\"\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/CO2METER_PDF.png?1094\"\u003e\u003cstrong\u003e\u003cspan style=\"color: red;\"\u003e Additional Application Notes\u003c\/span\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003ch3\u003eCase Studies\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003ca title=\"NASA Wearable CO2 Monitor uses CozIR Sensor\" href=\"\/en-ca\/blogs\/news\/co2-sensor-nasa-wearable-co2-monitor\"\u003eNASA Wearable CO2 Monitor uses CozIR Sensor\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv class=\"accessories\"\u003e\n\u003ch2\u003eAccessories\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003ca href=\"\/en-ca\/products\/gas-sensor-micro-pump\"\u003eSample Draw Pump Kit\u003c\/a\u003e - includes pump, hose, filters\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"\/en-ca\/products\/usb2-0-extension-cable\"\u003e\u003cspan class=\"caps\"\u003eUSB\u003c\/span\u003e Extension Cable\u003c\/a\u003e - extend USB cable \u003cspan\u003e16 ft. (5m)\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003ca title=\"View the Probe Enclosure for Development Kits\" href=\"\/en-ca\/products\/probe-enclosure-development-kit\"\u003eProbe Enclosure for Development Kits\u003c\/a\u003e - protects the sensor in harsh environments, with hydrophobic filter option.\u003c\/li\u003e\n\u003cli\u003e\n\u003ca title=\"Sensor Tube Cap Adapter\" href=\"\/en-ca\/products\/co2meter-sensor-tube-cap\"\u003eTC1-5 Tube Cap Adapter\u003c\/a\u003e - easily converts sensor from diffusion applications to sampling sensor.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"GSS","offers":[{"title":"SprintIR Wide Range 20% CO2 Sensor","offer_id":1092599447572,"sku":"GC-0017","price":389.4,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/GC-0017_SprintIR_-W_20_CO2_Sensor_l_CO2Meter.jpg?v=1753284135"},{"product_id":"uv-flux-25-oxygen-smart-flow-through-sensor","title":"LOX-O2-F UV Flux 25% Oxygen Flow Through Sensor","description":"\u003cp\u003eThe \u003cspan style=\"color: #115e67;\"\u003e\u003cstrong\u003eLOX-O2-F UV Flux 25% Oxygen Flow Through Sensor\u003cem\u003e \u003c\/em\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003cem\u003e(formerly known as OX-0055)\u003c\/em\u003e is designed to be used anywhere 0-25% oxygen levels need to be monitored in a closed system. This makes it a valuable tool for industry, researchers or scientific study.\u003c\/p\u003e\n\u003cp\u003eThe sensor benefits from lower power requirements than electrochemical and galvanic sensors, while providing a longer lifetime due to the non-depleting sensing principle.\u003c\/p\u003e\n\u003cp\u003eThe LOX-O2 is ppO2 and temperature compensated, enabling linear operation over a wide range without the need for additional system components. It does not contain lead or any other hazardous materials and has negligible cross sensitivity to other gases.\u003c\/p\u003e\n\u003ch2\u003eFeatures\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eFlow-through housing for easy sample gas management\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eFast response T90 \u0026lt;10s \u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eWorks in a vacuum and high oxygen concentrations\u003c\/li\u003e\n\u003cli\u003eRoHs \u0026amp; REACH compliant\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eModels\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eLOX-O2-F:  \u003c\/strong\u003eUVFlux Oxygen Sensor – For research, science, experiments or integration into high-volume OEM products.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCM-42990: \u003c\/strong\u003eUVFlux Oxygen Sensor w\/ MX Board and Flow Through Tube Cap\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCM-42991: \u003c\/strong\u003eUVFlux Oxygen Sensor Development Kit\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCM-200: Sensor Development Kit\u003c\/strong\u003e - Easy to use, simply plug the sensor into the PCB and plug it into your PC via USB. Use our free \u003ca href=\"\/en-ca\/pages\/downloads\" title=\"Gaslab software\"\u003eGasLab® software\u003c\/a\u003e to measure and graph carbon dioxide or use our \u003ca href=\"https:\/\/github.com\/co2meter-org\/ExampleCode\" title=\"Source code on Github\" rel=\"noopener\" target=\"_blank\"\u003elibrary of source code on Github\u003c\/a\u003e to build your own application or for OEM batch testing\/configuration. Order the sensor on this page, then \u003ca href=\"https:\/\/www.co2meter.com\/products\/gas-sensor-development-kit\" title=\"Gas Sensor Development Kit\"\u003eorder the Devkit here\u003c\/a\u003e.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan style=\"color: #286adc;\"\u003e\u003cstrong\u003eWe recommend that all first time users purchase both this sensor and the CM-200 Development Kit for fastest and easiest results.\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cdiv class=\"specifications\"\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMeasuring Gas:\u003c\/strong\u003e Oxygen\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMeasurement Range:\u003c\/strong\u003e 0 - 25% O2\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSensing Method:\u003c\/strong\u003e Fluorescence quenching by oxygen\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMeasurement Interval:\u003c\/strong\u003e 1 Sample\/second\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOxygen Pressure Range: \u003c\/strong\u003e0 — 300mbar ppO2\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eResponse Time:\u003c\/strong\u003e T90 \u0026lt; 10s\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWarm-Up Time:\u003c\/strong\u003e \u0026lt; 60 Seconds at 72\u003cspan\u003e°F (22°C)\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAccuracy:\u003c\/strong\u003e Better than 2% at full scale\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHumidity: \u003c\/strong\u003e0-99% RH (non-condensing)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eResolution:\u003c\/strong\u003e 0.10% \/ 0.1mbar\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTemperature Accuracy:\u003c\/strong\u003e +\/- 2 degrees C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePressure: \u003c\/strong\u003e±5mbar\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating Temperature:\u003c\/strong\u003e -30°C to +60°C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBarometric Pressure Range:\u003c\/strong\u003e 500 to 1200mbar\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLifetime:\u003c\/strong\u003e \u0026gt; 5 years\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eElectrical \/ Mechanical\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSupply voltage:\u003c\/strong\u003e 4.5 - 5.5 VDC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSupply current: \u003c\/strong\u003e\u0026lt;7.5mA (streaming one sample per second)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput type: \u003c\/strong\u003e3.3V TTL level USART\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInterface:\u003c\/strong\u003e UART or analog\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eWarranty\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e90 days - See\u003ca title=\"Terms and Conditions\" href=\"https:\/\/www.co2meter.com\/pages\/terms-conditions\"\u003e CO2Meter Terms and Conditions.\u003c\/a\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"documents\"\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/www.processsensing.com\/docs\/datasheet\/DS0145rev4_LOX-02-F.pdf\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/CO2METER_PDF.png?1094\" alt=\"SST Oxygen Sensor Datasheet\"\u003e\u003cstrong\u003e\u003cspan style=\"color: red;\"\u003e Data Sheet (pdf)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/sstsensing.com\/wp-content\/uploads\/2025\/05\/UG-001_LuminOx_UserGuide_rev2.pdf\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/CO2METER_PDF.png?1094\" alt=\"SST Sensor Manual Operation Guide\"\u003e\u003cstrong\u003e\u003cspan style=\"color: red;\"\u003e Sensor Manual (pdf)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"software\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv class=\"accessories\"\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/www.co2meter.com\/products\/gas-sensor-development-kit\" title=\"CO2Meter Gas Sensor Development Kit\"\u003e\u003cstrong\u003eGas Sensor Development Kit\u003c\/strong\u003e (CM-200)\u003c\/a\u003e- designed to provide customers with an easy drop-in solution. Includes our free \u003ca title=\"Gaslab data logging software\" href=\"https:\/\/www.co2meter.com\/pages\/downloads\"\u003eGaslab data logging software\u003c\/a\u003e. Sensor sold separately.\u003c\/li\u003e\n\u003cli\u003e\n\u003ca title=\"micro-pump kit\" href=\"\/en-ca\/products\/gas-sensor-micro-pump\"\u003e\u003cstrong\u003eMicro-Pump Kit\u003c\/strong\u003e\u003c\/a\u003e\u003cspan\u003e \u003c\/span\u003eincludes all the tools you need to utilize the tube-cap adapters as part of a sampling sensor system.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003ca title=\"nafion tubing\" href=\"\/en-ca\/products\/nafion-gas-sample-drying-tubing\"\u003eNafion Tubing\u003c\/a\u003e \u003c\/strong\u003eis a highly selective, semi-permeable membrane to water vapor. If gases inside Nafion tubing are wetter than gases surrounding the tubing, drying will occur. If the surrounding gases are wetter, humidification will occur.\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"\/en-ca\/products\/gas-sampling-pump\"\u003e\u003cstrong\u003eMicro Gas Sampling Pumps\u003c\/strong\u003e\u003c\/a\u003e\u003cspan\u003e \u003c\/span\u003eprovide a constant flow of air across the sensor with a tube cap - perfect for bench-top testing of sensors for closed-loop sampling applications.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e","brand":"SST","offers":[{"title":"LOX-O2-F: UVFlux Oxygen Sensor","offer_id":43960394678470,"sku":"LOX-O2-F","price":145.0,"currency_code":"USD","in_stock":true},{"title":"CM-42990: UVFlux Oxygen Sensor with MX Board","offer_id":43960394776774,"sku":"CM-42990","price":307.0,"currency_code":"USD","in_stock":true},{"title":"CM-42991: UVFlux Oxygen Sensor Development Kit","offer_id":43960394875078,"sku":"CM-42991","price":340.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/LOX-02-F.jpg?v=1753284129"},{"product_id":"senseair-sunrise-co2-sensor","title":"006-0-0008 Senseair Sunrise HVAC CO2 Sensor","description":"\u003cp\u003eThe \u003cstrong\u003eSenseair Sunrise HVAC 1% CO2 Sensor\u003cem\u003e \u003c\/em\u003e\u003c\/strong\u003e006-0-0008 \u003cstrong\u003e\u003c\/strong\u003e(\u003cem\u003eformerly known as SE-12) \u003c\/em\u003eis a miniature sensor module for battery-powered applications. It gives full control over the sensor's integration into a host system, flexibility in changing of the CO2 measurement period, and power consumption.\u003c\/p\u003e\n\u003cp\u003eThe NDIR CO2 sensor uses an LED light source that saves power and makes it resistant to vibration while maintaining high precision. It has a life expectancy of more than 15 years.\u003c\/p\u003e\n\u003cp\u003eThe self-correcting ABC algorithm automatically calibrates the sensor and assures it will still be accurate which is key in wireless applications.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eWide supply voltage range enables a variety of battery options\u003c\/li\u003e\n\u003cli\u003eRobust and resistant to vibrations and tough environment \u003c\/li\u003e\n\u003cli\u003eSelf Calibration\u003c\/li\u003e\n\u003cli\u003eHigh precision NDIR sensor with LED Technology\u003c\/li\u003e\n\u003cli\u003eAdjustable measurement period by host\u003c\/li\u003e\n\u003cli\u003eAdjustable ABC period by host\u003c\/li\u003e\n\u003cli\u003eUltra-low power consumption\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eModels\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSenseair Sunrise HVAC CO2 Sensor\u003c\/strong\u003e (006-0-0008) - pinless design for integration into high-volume OEM products. \u003ca title=\"request for quote\" href=\"\/en-ca\/pages\/rfq\"\u003eContact us directly\u003c\/a\u003e for wholesale pricing on large quantities of this sensor.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSensor Development Kit\u003c\/strong\u003e (CM-200) - Easy to use, simply plug the sensor into the PCB and plug it into your PC via USB. Use our free \u003ca title=\"Gaslab software\" href=\"\/en-ca\/pages\/downloads\"\u003eGasLab® software\u003c\/a\u003e to measure and graph carbon dioxide or use our \u003ca rel=\"noopener\" title=\"Source code on Github\" href=\"https:\/\/github.com\/co2meter-org\/ExampleCode\" target=\"_blank\"\u003elibrary of source code on Github\u003c\/a\u003e to build your own application or for OEM batch testing\/configuration. Order sensors on this page, then \u003ca title=\"Gas Sensor Development Kit\" href=\"https:\/\/www.co2meter.com\/products\/gas-sensor-development-kit\"\u003eorder the Devkit here\u003c\/a\u003e.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan style=\"color: #286adc;\" data-mce-style=\"color: #286adc;\"\u003e\u003cstrong\u003eWe recommend that all first time users purchase both this sensor and the CM-200 Development Kit for fastest and easiest results.\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cdiv class=\"specifications\"\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eCO2 Measurement: non-dispersive infrared (NDIR)\u003c\/li\u003e\n\u003cli\u003eMeasurement Method: Diffusion\u003c\/li\u003e\n\u003cli\u003eMeasurement Range: 400-10,000 ppm\u003c\/li\u003e\n\u003cli\u003eAccuracy: ±30 ppm ± 3% of reading\u003c\/li\u003e\n\u003cli\u003eMeasurement Period: Adjustable by host\u003c\/li\u003e\n\u003cli\u003ePower Supply: 3.05-5.5 V4\u003c\/li\u003e\n\u003cli\u003eMax Current: 125 mA\u003c\/li\u003e\n\u003cli\u003eDimensions: 1.3 x 0.78 x 0.47 in.\u003c\/li\u003e\n\u003cli\u003eWeight: 4.9 \u003cspan\u003e±\u003c\/span\u003e 0.1 g\u003c\/li\u003e\n\u003cli\u003eLife expectancy: \u0026gt;15 years\u003c\/li\u003e\n\u003cli\u003eOperation range: 0-50\u003cspan\u003e°C, 0-85% RH\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003eCommunication Options: UART, I2C\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eWarranty\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e90 days - See\u003ca title=\"Terms and Conditions\" href=\"https:\/\/www.co2meter.com\/pages\/terms-conditions\"\u003e CO2Meter Terms and Conditions.\u003c\/a\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"documents\"\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/rmtplusstoragesenseair.blob.core.windows.net\/docs\/Dev\/publicerat\/PSH12460.pdf\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/CO2METER_PDF.png?1094\" alt=\"Senseair HVAC Datasheet\"\u003e\u003cstrong\u003e\u003cspan style=\"color: red;\"\u003e Data Sheet (pdf)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/rmtplusstoragesenseair.blob.core.windows.net\/docs\/Dev\/publicerat\/PSP12440.pdf\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/CO2METER_PDF.png?1094\" alt=\"Senseair HVAC Manual\"\u003e\u003cstrong\u003e\u003cspan style=\"color: red;\"\u003e Manual (pdf)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/rmtplusstoragesenseair.blob.core.windows.net\/docs\/Dev\/publicerat\/ANO4947.pdf\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/CO2METER_PDF.png?1094\" alt=\"Custom Integration Manual\"\u003e\u003cstrong\u003e\u003cspan style=\"color: red;\"\u003e Sensor Handling Manual (pdf)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/I2C-Sunrise-Modbus-Manual_Rev1.pdf?v=1653446719\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/CO2METER_PDF.png?1094\" alt=\"I2C Guide\"\u003e\u003cstrong\u003e\u003cspan style=\"color: red;\"\u003eI2C Sunrise Guide(pdf)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/Modbus_Sunrise_Revised8.pdf?v=1653446778\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/CO2METER_PDF.png?1094\" alt=\"SE-11 Modbus Guide\"\u003e\u003cstrong\u003e\u003cspan style=\"color: red;\"\u003e Modbus Guide (pdf)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/Manual-Development-Kit-SE-11.pdf?v=1653446817\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/CO2METER_PDF.png?1094\" alt=\"SE11 Development Kit Manual\"\u003e\u003cstrong\u003e\u003cspan style=\"color: red;\"\u003eSE-12 Development Kit, Arduino, Raspberry Pi Code (pdf)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/SenseairISO.pdf?v=1613679881\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/CO2METER_PDF.png?1093\" alt=\"Senseair ISO Certification\"\u003e\u003cstrong\u003e\u003cspan style=\"color: red;\"\u003e Senseair ISO Certification (pdf)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"software\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv class=\"accessories\"\u003e\n\u003ch3\u003eAccessories\u003c\/h3\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/www.co2meter.com\/products\/gas-sensor-development-kit\" title=\"CO2Meter Gas Sensor Development Kit\"\u003e\u003cstrong\u003eGas Sensor Development Kit \u003c\/strong\u003e\u003c\/a\u003e- designed to provide customers with an easy drop-in solution. Includes our free \u003ca title=\"Gaslab data logging software\" href=\"https:\/\/www.co2meter.com\/pages\/downloads\"\u003eGaslab data logging software\u003c\/a\u003e. Sensor sold separately.\u003c\/p\u003e\n\u003c\/div\u003e","brand":"Senseair","offers":[{"title":"Default Title","offer_id":19838776868982,"sku":"006-0-0008","price":59.4,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/006-0-0008_SE-12_CO2SensorlCO2Meter_89da3bbc-ba01-4955-a112-b542c40fcd9c.jpg?v=1753284128"},{"product_id":"explorir-20-co2-smart-led-sensor","title":"ExplorIR®-M 20% CO2 Sensor","description":"\u003cp\u003eThe \u003cspan style=\"color: #115e67;\"\u003e\u003cstrong\u003eExplorIR®-M-20\u003c\/strong\u003e\u003c\/span\u003e \u003cspan\u003e(\u003cem\u003eformerly \u003c\/em\u003e\u003c\/span\u003e\u003cem\u003eknown as\u003cstrong\u003e \u003c\/strong\u003eMinIR-GC-0026\u003c\/em\u003e)\u003cstrong\u003e \u003c\/strong\u003eis a miniature CO2 sensor, capable of measuring up to 20% CO2 concentration by volume. Its compact and robust design enables easy integration into gas monitoring and detection systems.\u003c\/p\u003e\n\u003cp\u003eExplorIR®-M is specifically designed for applications that require the sensor to operate reliably in extreme environmental conditions, especially where the pressure, temperature or vibration regime is particularly harsh. This makes it the ideal for applications from aerospace to food storage during transportation.\u003c\/p\u003e\n\u003cp\u003eThe sensor is designed to take 2 readings per second, making it ideal for applications where gas concentrations are rapidly changing.\u003c\/p\u003e\n\u003cp\u003eThe ExplorIR®-M uses patented solid-state optical technology, which enables the sensor to provide high accuracy CO2 measurement capability over an extended lifetime.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMeasures up to 20% CO2\u003c\/li\u003e\n\u003cli\u003eLow power CO2 sensor\u003c\/li\u003e\n\u003cli\u003eSolid-state LED optical technology\u003c\/li\u003e\n\u003cli\u003eVibration and shock resistant\u003c\/li\u003e\n\u003cli\u003eUART interface\u003c\/li\u003e\n\u003cli\u003eBuilt-in auto-zero function\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eModels\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eEXPLORIR-M-20 - \u003c\/strong\u003eExplorIR®-M-20 Sensor for integration into high-volume OEM products.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCM-40530\u003c\/strong\u003e - EXPLORIR-M 20% CO2 Sensor w\/ MX Board\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCM-40531\u003c\/strong\u003e - EXPLORIR-M 20% CO2 Sensor Development Kit - Easy to use, simply plug the sensor module PCB into your PC via USB. Use our free \u003ca title=\"Gaslab Software\" href=\"https:\/\/www.co2meter.com\/pages\/downloads\"\u003eGasLab® software\u003c\/a\u003e to measure and graph carbon dioxide in real time or for data logging. Use a \u003ca href=\"\/en-ca\/products\/co2meter-sensor-tube-cap\" title=\"tube cap adapter\"\u003etube cap adapter\u003c\/a\u003e to create a sampling sensor.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSensor Development Kit\u003c\/strong\u003e (CM-200) - Easy to use, simply plug the sensor into the PCB and plug it into your PC via USB. Use our free \u003ca href=\"\/en-ca\/pages\/downloads\" title=\"Gaslab software\"\u003eGasLab® software\u003c\/a\u003e to measure and graph carbon dioxide or use our \u003ca href=\"https:\/\/github.com\/co2meter-org\/ExampleCode\" title=\"Source code on Github\" rel=\"noopener\" target=\"_blank\"\u003elibrary of source code on Github\u003c\/a\u003e to build your own application or for OEM batch testing\/configuration. Order sensors on this page, then \u003ca href=\"https:\/\/www.co2meter.com\/products\/gas-sensor-development-kit\" title=\"Gas Sensor Development Kit\"\u003eorder the Devkit here\u003c\/a\u003e.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan style=\"color: #286adc;\"\u003e\u003cstrong\u003eWe recommend that all first-time users purchase either the CM-40531 or CM-200 Development Kit for fastest and easiest results.\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cdiv class=\"specifications\"\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCO2 Sensing Method:\u003c\/strong\u003e Non-dispersive infrared (NDIR) absorption\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSample Method:\u003c\/strong\u003e \u003cspan\u003eSolid-state LED NDIR Diffusion\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMeasurement Range:\u003c\/strong\u003e 0-5%\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAccuracy:\u003c\/strong\u003e ±70 ppm +\/- 5% of reading @ STP\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTime to 1st Reading: \u003c\/strong\u003e\u0026lt;1.2 seconds\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eResolution:\u003c\/strong\u003e 10ppm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNon Linearity:\u003c\/strong\u003e \u0026lt; 1% of FS\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating Pressure Range:\u003c\/strong\u003e 950 mbar to 10 bar\n\u003cul\u003e\n\u003cli\u003eexternal pressure calibration\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePressure Dependence:\u003c\/strong\u003e 0.1% of reading per mbar @STP\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWarm-up Time:\u003c\/strong\u003e \u0026lt; 10s. 1.2 secs to first reading\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eResponse Time:\u003c\/strong\u003e \u0026lt;30 Seconds (Diffusion Limited)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eReadings per Second: \u003c\/strong\u003e2\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating Temperature:\u003c\/strong\u003e 0°C to 50°C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating Humidity: \u003c\/strong\u003e0 to 95% RH, non-condensing\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStorage Temperature: \u003c\/strong\u003e-40°C to +70°C\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDimensions:\u003c\/strong\u003e 20.9 mm x 21.7 mm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e 4g sensor\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSensor Life Expectancy: \u003c\/strong\u003e\u0026gt; 15 years\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eElectrical \/ Mechanical\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Input:\u003c\/strong\u003e 3.25V to 5.5V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePeak Current:\u003c\/strong\u003e 33mA @ 2 readings\/sec.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAverage Current:\u003c\/strong\u003e \u0026lt;1.5mA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Consumption:\u003c\/strong\u003e 3.5mW @ 3.3V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMeasurement Output\/Interface:\u003c\/strong\u003e UART (Serial)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eWarranty\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e90 days - See\u003ca title=\"Terms and Conditions\" href=\"https:\/\/www.co2meter.com\/pages\/terms-conditions\"\u003e CO2Meter Terms and Conditions\u003c\/a\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"documents\"\u003e\n\u003ch3\u003eDocuments\u003c\/h3\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/ExplorIR-M_Data_Sheet_Rev_4.14_-_Updated_Logo.pdf?v=1751036376\"\u003e\u003cimg alt=\"MINIR Data Sheet\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/CO2METER_PDF.png?1093\"\u003e\u003cstrong\u003e\u003cspan style=\"color: red;\"\u003e Data Sheet (pdf)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/Mechanical_Diagram_-ExplorIR-M-CO2Meter.pdf\"\u003e\u003cimg alt=\"MinIR Dimensional drawings\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/CO2METER_PDF.png?1093\"\u003e\u003cstrong\u003e\u003cspan style=\"color: red;\"\u003e Dimensional Drawings (pdf)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/2027_FM_ISO_Certificate.pdf?v=1742814585\"\u003e\u003cstrong\u003e\u003cspan style=\"color: red;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/CO2METER_PDF.png?1094\" alt=\"GSS Quality Certification\"\u003e\u003cspan style=\"color: rgb(255, 42, 0);\"\u003e Quality Certificate - ISO9001 (pdf)\u003c\/span\u003e\u003c\/span\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003cbr\u003e\n\u003cp\u003e\u003ca href=\"\/en-ca\/pages\/co2meter-resources\"\u003e\u003cimg alt=\"GSS App Notes\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/CO2METER_PDF.png?1093\"\u003e\u003cstrong\u003e\u003cspan style=\"color: red;\"\u003e GSS Sensor Application Notes (pdf)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"software\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv class=\"accessories\"\u003e\n\u003ch3\u003eAccessories\u003c\/h3\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/www.co2meter.com\/products\/gas-sensor-development-kit\" title=\"CO2Meter Gas Sensor Development Kit\"\u003e\u003cstrong\u003eGas Sensor Development Kit\u003c\/strong\u003e (CM-200)\u003c\/a\u003e- designed to provide customers with an easy drop-in solution. Includes our free \u003ca title=\"Gaslab data logging software\" href=\"https:\/\/www.co2meter.com\/pages\/downloads\"\u003eGaslab data logging software\u003c\/a\u003e. Sensor sold separately.\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/www.co2meter.com\/collections\/accessories\/products\/co2meter-sensor-tube-cap\" title=\"Tube cap adapter\"\u003e\u003cstrong\u003eTube cap adapters\u003c\/strong\u003e\u003c\/a\u003e easily convert 20mm standard gas sensors from diffusion to sampling sensors. Molded polymer. \u003cstrong\u003eTube cap adapters are not pre-installed\u003c\/strong\u003e. For accurate results you must mount the tube cap permanently.\u003ca href=\"\/en-ca\/products\/sensor-tube-cap-adapter-for-mx-board?variant=31376246079606\" title=\"tube cap adapter\"\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"\/en-ca\/products\/gas-sensor-micro-pump\" title=\"micro-pump kit\"\u003e\u003cstrong\u003eMicro-Pump Kit\u003c\/strong\u003e\u003c\/a\u003e\u003cspan\u003e \u003c\/span\u003eincludes all the tools you need to utilize the tube-cap adapters as part of a sampling sensor system.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003ca href=\"\/en-ca\/products\/nafion-gas-sample-drying-tubing\" title=\"nafion tubing\"\u003eNafion Tubing\u003c\/a\u003e \u003c\/strong\u003eis a highly selective, semi-permeable membrane to water vapor. If gases inside Nafion tubing are wetter than gases surrounding the tubing, drying will occur. If the surrounding gases are wetter, humidification will occur.\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"\/en-ca\/products\/gas-sampling-pump\"\u003e\u003cstrong\u003eMicro Gas Sampling Pumps\u003c\/strong\u003e\u003c\/a\u003e\u003cspan\u003e \u003c\/span\u003eprovide a constant flow of air across the sensor with a tube cap - perfect for bench-top testing of sensors for closed-loop sampling applications.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003ca href=\"\/en-ca\/products\/probe-enclosure-development-kit\" title=\"View the Probe Enclosure for Development Kits\"\u003eProbe Enclosure for Development Kits\u003c\/a\u003e\u003c\/strong\u003e gives a strong and secure container to mount the sensor. Hydrophobic filters available for enclosure for outdoor use.\u003c\/p\u003e\n\u003cp\u003e\u003ciframe width=\"560\" height=\"315\" src=\"https:\/\/www.youtube.com\/embed\/wYSLkLuS-xA\"\u003e\u003c\/iframe\u003e\u003c\/p\u003e\n\u003c\/div\u003e","brand":"GSS","offers":[{"title":"EXPLORIR-M-20: ExplorIR-M 20% CO2 Sensor","offer_id":43948803031238,"sku":"EXPLORIR-M-20","price":197.0,"currency_code":"USD","in_stock":true},{"title":"CM-40530 - ExplorIR-M 20% Sensor w\/ MX Board","offer_id":43960991842502,"sku":"CM-40530","price":395.0,"currency_code":"USD","in_stock":false},{"title":"CM-40531: ExplorIR-M 20% CO2 Sensor Devkit","offer_id":43948806275270,"sku":"CM-40531","price":428.0,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/EXPLORIR-M-2020_CO2Sensor.jpg?v=1753284120"},{"product_id":"gss-sprintir-r-5-co2-sensor","title":"SprintIR®-R 5% CO2 Sensor","description":"\u003cp\u003eThe \u003cstrong\u003e\u003cspan style=\"color: #115e67;\"\u003eSPRINTIR-R-5 5% CO2 Sensor \u003c\/span\u003e\u003c\/strong\u003e(\u003cem\u003eformerly known as the GC-0031) \u003c\/em\u003eis the fastest commercial CO2 sensor on the market.\u003c\/p\u003e\n\u003cp\u003eCapable of measuring up to 5% CO2 levels up to 50 times a second, this sensor is designed for applications where high speed between measurements and fast response time are most important\u003c\/p\u003e\n\u003cp\u003eThis sensor is fitted with a standard flow-through adaptor so the CO2 gas can be passed over the optical sensor at high speed using an optional micro-pump.\u003c\/p\u003e\n\u003cp\u003eThe SprintIR®-R-5 uses patented NDIR solid-state LED optical technology enabling the sensor to respond to rapidly changing CO2 without compromising performance.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eHigh-Speed Sensing and Fast Response (50hz)\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eDigital (UART) output\u003c\/li\u003e\n\u003cli\u003eIdeal for Healthcare and Food Packaging applications\u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eModels\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSPRINTIR-R-5\u003c\/strong\u003e – for integration into high-volume OEM products\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCM-20321\u003c\/strong\u003e - SprintIR-R-5 5% CO2 Sensor Development Kit\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSensor Development Kit\u003c\/strong\u003e (CM-200) - Easy to use, simply plug the sensor into the PCB and plug it into your PC via USB. Use our free \u003ca href=\"\/en-ca\/pages\/downloads\" title=\"Gaslab software\"\u003eGasLab® software\u003c\/a\u003e to measure and graph carbon dioxide or use our \u003ca href=\"https:\/\/github.com\/co2meter-org\/ExampleCode\" title=\"Source code on Github\" rel=\"noopener\" target=\"_blank\"\u003elibrary of source code on Github\u003c\/a\u003e to build your own application or for OEM batch testing\/configuration. Order sensors on this page, then \u003ca href=\"https:\/\/www.co2meter.com\/products\/gas-sensor-development-kit\" title=\"Gas Sensor Development Kit\"\u003eorder the Devkit here\u003c\/a\u003e.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv class=\"specifications\"\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCO2 Sensing Method: \u003c\/strong\u003ePatented solid-state NDIR absorption\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSample Method:\u003c\/strong\u003e Flow through adapter\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMeasurement Range:\u003c\/strong\u003e 0-5%, \u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAccuracy:\u003c\/strong\u003e ±70 ppm +\/- 5% of reading \u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eResolution:\u003c\/strong\u003e 10 ppm\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMeasurement noise:\u003c\/strong\u003e \u0026lt; 10% of reading with no digital filtering\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePressure Dependence:\u003c\/strong\u003e 0.15% of reading per mbar in normal atmospheric conditions\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating pressure range:\u003c\/strong\u003e 500mbar to 2 bar with flow through adapter\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eResponse Time:\u003c\/strong\u003e Flow Rate Dependent\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUpdate rate:\u003c\/strong\u003e 50 Hz\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSensor Life Expectancy:\u003c\/strong\u003e \u0026gt; 15 years\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eElectrical\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Input:\u003c\/strong\u003e 3.25 to 5.5V. (3.3V recommended)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePeak Current:\u003c\/strong\u003e 100mA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAverage Current:\u003c\/strong\u003e \u0026lt;15mA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Consumption:\u003c\/strong\u003e 35 mW \u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCommunication:\u003c\/strong\u003e UART \u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnector:\u003c\/strong\u003e 4 x 0.5mm sq pins\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eWarranty\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e90 days - See\u003ca href=\"https:\/\/www.co2meter.com\/pages\/terms-conditions\" title=\"Terms and Conditions\"\u003e CO2Meter Terms and Conditions.\u003c\/a\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"documents\"\u003e\n\u003ch3\u003eDocuments\u003c\/h3\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/SprintIR-R_Data_Sheet_Rev_4.12_-_Updated_Logo.pdf?v=1751034701\" title=\"GSS and CO2Meter Product Flyer\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/CO2METER_PDF.png?1094\" alt=\"SprintIR R Data Sheet\"\u003e\u003cstrong\u003e\u003cspan style=\"color: red;\"\u003e Data Sheet (pdf)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/SprintIR-R_Data_Sheet_Rev_4.12_-_Updated_Logo.pdf?v=1751034701\" title=\"GSS and CO2Meter User Manual and Data Sheet\"\u003e\u003cimg alt=\"SprintIR R Manual\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/CO2METER_PDF.png?1094\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/SprintIR-R_Data_Sheet_Rev_4.12_3.pdf\" title=\"GSS and CO2Meter User Manual\"\u003e\u003cstrong\u003e\u003cspan style=\"color: red;\"\u003e Sensor Manual (pdf)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/Mechanical_Diagram_-SprintIR-6S-CO2Meter.pdf\"\u003e\u003cimg alt=\"Mechanical Diagram\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/CO2METER_PDF.png?1094\"\u003e\u003cstrong\u003e\u003cspan style=\"color: red;\"\u003e Mechanical Diagram (pdf)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/2027_FM_ISO_Certificate.pdf?v=1742814585\"\u003e\u003cstrong\u003e\u003cspan style=\"color: red;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/CO2METER_PDF.png?1094\" alt=\"GSS Quality Certification\"\u003e\u003cspan style=\"color: rgb(255, 42, 0);\"\u003e Quality Certificate - ISO9001 (pdf)\u003c\/span\u003e\u003c\/span\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003cbr\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/AN015_Using_a_pump_to_sample_gas_Application_Note_Rev_1.1.pdf?v=1651156092\"\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/CO2METER_PDF.png?1094\"\u003e\u003cstrong\u003e\u003cspan style=\"color: red;\"\u003e GSS Guide for Sample Draw Pumps (pdf)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/SprintIR-Speed-Comparison.pdf?v=1653495789\"\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/CO2METER_PDF.png?1094\"\u003e\u003cstrong\u003e\u003cspan style=\"color: red;\"\u003e SprintIR Speed Comparison Test (pdf)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"\/en-ca\/pages\/co2meter-resources\"\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/CO2METER_PDF.png?1094\"\u003e\u003cstrong\u003e\u003cspan style=\"color: red;\"\u003e Additional Application Notes\u003c\/span\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003ch3 class=\"software\"\u003eAccessories:\u003c\/h3\u003e\n\u003cdiv class=\"accessories\"\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003ca title=\"CO2Meter Gas Sensor Development Kit\" href=\"https:\/\/www.co2meter.com\/products\/gas-sensor-development-kit\"\u003e\u003cstrong\u003eGas Sensor Development Kit\u003c\/strong\u003e (CM-200)\u003c\/a\u003e- designed to provide customers with an easy drop-in solution. Includes our free \u003ca href=\"https:\/\/www.co2meter.com\/pages\/downloads\" title=\"Gaslab data logging software\"\u003eGaslab data logging software\u003c\/a\u003e. Sensor sold separately.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCM-0032-6S\/R -\u003c\/strong\u003e Custom USB cable enables communication to GasLab Software for Sensor Board and Development Kit.\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"\/en-ca\/products\/gas-sensor-micro-pump\" title=\"micro-pump kit\"\u003e\u003cstrong\u003eMicro-Pump Kit\u003c\/strong\u003e\u003c\/a\u003e includes all the tools you need to utilize the tube-cap adapters as part of a sampling sensor system.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003ca href=\"\/en-ca\/products\/nafion-gas-sample-drying-tubing\" title=\"nafion tubing\"\u003eNafion Tubing\u003c\/a\u003e\u003c\/strong\u003e is a highly selective, semi-permeable membrane to water vapor. If gases inside Nafion tubing are wetter than gases surrounding the tubing, drying will occur. If the surrounding gases are wetter, humidification will occur.\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"\/en-ca\/products\/gas-sampling-pump\"\u003e\u003cstrong\u003eMicro Gas Sampling Pumps\u003c\/strong\u003e\u003c\/a\u003e provides a constant flow of air across the sensor with a tube cap - perfect for bench-top testing of sensors for closed-loop sampling applications.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e","brand":"GSS","offers":[{"title":"SPRINTIR-R-5: 5% CO2 Sensor","offer_id":43960963170502,"sku":"SPRINTIR-R-5","price":362.0,"currency_code":"USD","in_stock":true},{"title":"CM-20321: SprintIR-R 5% CO2 Sensor and DevKit","offer_id":43960963203270,"sku":"CM-20321","price":549.0,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/SprintIR_-R-55_CO2SensorlCO2MeterSPRINTIR-R-5_GC-0031.jpg?v=1753284096"},{"product_id":"sprintir-r-20-co2-sensor","title":"SPRINTIR®-R 20% CO2 Sensor","description":"\u003cp\u003eThe \u003cspan style=\"color: #115e67;\"\u003e\u003cstrong\u003eSprintIR®-R 20% CO2 Sensor\u003c\/strong\u003e\u003c\/span\u003e \u003cem\u003e(formerly known as GC-0032)\u003c\/em\u003e\u003cstrong\u003e \u003c\/strong\u003eis the fastest carbon dioxide sensor on the market. Capable of measuring up to 20% CO2 levels up to 50 times a second, this sensor is designed for applications where high speed between measurements and fast response time are most important\u003c\/p\u003e\n\u003cp\u003eThis sensor is fitted with a standard flow-through adaptor so the CO2 gas can be passed over the optical sensor at high speed using an optional micro-pump.\u003c\/p\u003e\n\u003cp\u003eThe SprintIR®-R-5 uses patented NDIR solid-state LED optical technology enabling the sensor to respond to rapidly changing CO2 without compromising performance.\u003c\/p\u003e\n\u003ch2\u003eFeatures\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eTakes 50 readings per second\u003c\/li\u003e\n\u003cli\u003eOptional customized flow through adapters\u003c\/li\u003e\n\u003cli\u003eBuilt-in auto-zero functionality\u003c\/li\u003e\n\u003cli\u003eDigital (UART) data interface\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eRoHS and REACH compliant\u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eModels\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eGC-0032\u003c\/strong\u003e – 20% CO2 Sensor only, for integration into high-volume OEM products.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCM-20420\u003c\/strong\u003e – 20% CO2 Sensor w\/ MX Board\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eCM-20421\u003c\/b\u003e– 20% CO2 Sensor and Development Kit\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSensor Development Kit\u003c\/strong\u003e (CM-200) - Easy to use, simply plug the sensor into the PCB and plug it into your PC via USB. Use our free \u003ca title=\"Gaslab software\" href=\"\/en-ca\/pages\/downloads\"\u003eGasLab® software\u003c\/a\u003e to measure and graph carbon dioxide or use our \u003ca rel=\"noopener\" title=\"Source code on Github\" href=\"https:\/\/github.com\/co2meter-org\/ExampleCode\" target=\"_blank\"\u003elibrary of source code on Github\u003c\/a\u003e to build your own application or for OEM batch testing\/configuration. Order sensors on this page, then \u003ca title=\"Gas Sensor Development Kit\" href=\"https:\/\/www.co2meter.com\/products\/gas-sensor-development-kit\"\u003eorder the Devkit here\u003c\/a\u003e.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan style=\"color: #286adc;\"\u003e\u003cstrong\u003eWe recommend that all first time users purchase both this sensor and the CM-200 Development Kit for fastest and easiest results.\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cdiv class=\"specifications\"\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCO2 Sensing Method:\u003c\/strong\u003e Patented solid-state NDIR absorption\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMeasurement Range:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e0-20% CO2\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSample Method:\u003c\/strong\u003e Flow through adapter\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAccuracy:\u003c\/strong\u003e ±70 ppm +\/- 5% of reading @ STP\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTime to 1st Reading: \u003c\/strong\u003e\u0026lt;0.2 Seconds\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eResponse Time: \u003c\/strong\u003eFlow Dependent\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eReadings per Second: \u003c\/strong\u003e50\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eResolution:\u003c\/strong\u003e 10ppm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMeasurement Noise:\u003c\/strong\u003e \u0026lt;10% of reading with no digital filtering\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePressure Dependence:\u003c\/strong\u003e 0.15% of reading per mbar in normal conditions\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWarm-up Time:\u003c\/strong\u003e \u0026lt; 30s\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating Conditions:\u003c\/strong\u003e 0°C to 50°C, 0 to 95% RH, non-condensing\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDimensions: \u003c\/strong\u003e24.8mm x 28mm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e7.5g\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSensor Life Expectancy:\u003c\/strong\u003e \u0026gt;15 years\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eElectrical \/ Mechanical\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Input:\u003c\/strong\u003e 3.25V to 5.5V. (3.3V recommended)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Consumption (typ.): \u003c\/strong\u003e100mW @3.3V\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePeak Current:\u003c\/strong\u003e 100mA @ 2 readings\/sec.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAverage Current:\u003c\/strong\u003e \u0026lt;15mA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Consumption:\u003c\/strong\u003e 35mW\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMeasurement Output\/Interface:\u003c\/strong\u003e UART\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eWarranty\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e90 days - See\u003ca title=\"Terms and Conditions\" href=\"https:\/\/www.co2meter.com\/pages\/terms-conditions\"\u003e CO2Meter Terms and Conditions\u003c\/a\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"documents\"\u003e\n\u003ch3\u003eDocuments\u003c\/h3\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/SprintIR-R_Data_Sheet_Rev_4.12_-_Updated_Logo.pdf?v=1751034701\" title=\"GSS and CO2Meter Product Flyer\"\u003e\u003cimg alt=\"SprintIR R Data Sheet\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/CO2METER_PDF.png?1094\"\u003e\u003cstrong\u003e\u003cspan style=\"color: red;\"\u003e Data Sheet (pdf)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/Mechanical_Diagram_-SprintIR-6S-CO2Meter.pdf\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/CO2METER_PDF.png?1094\" alt=\"Mechanical Diagram\"\u003e\u003cstrong\u003e\u003cspan style=\"color: red;\"\u003e Mechanical Diagram (pdf)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/2027_FM_ISO_Certificate.pdf?v=1742814585\"\u003e\u003cstrong\u003e\u003cspan style=\"color: red;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/CO2METER_PDF.png?1094\" alt=\"GSS Quality Certification\"\u003e\u003cspan style=\"color: rgb(255, 42, 0);\"\u003e Quality Certificate - ISO9001 (pdf)\u003c\/span\u003e\u003c\/span\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003cbr\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/AN015_Using_a_pump_to_sample_gas_Application_Note_Rev_1.1.pdf?v=1651156092\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/CO2METER_PDF.png?1094\" alt=\"\"\u003e\u003cstrong\u003e\u003cspan style=\"color: red;\"\u003e GSS Guide for Sample Draw Pumps (pdf)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"\/en-ca\/pages\/co2meter-resources\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/CO2METER_PDF.png?1094\" alt=\"\"\u003e\u003cstrong\u003e\u003cspan style=\"color: red;\"\u003e Additional Application Notes\u003c\/span\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"software\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv class=\"accessories\"\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/www.co2meter.com\/products\/gas-sensor-development-kit\" title=\"CO2Meter Gas Sensor Development Kit\"\u003e\u003cstrong\u003eGas Sensor Development Kit\u003c\/strong\u003e (CM-200)\u003c\/a\u003e- designed to provide customers with an easy drop-in solution. Includes our free \u003ca title=\"Gaslab data logging software\" href=\"https:\/\/www.co2meter.com\/pages\/downloads\"\u003eGaslab data logging software\u003c\/a\u003e. Sensor sold separately.\u003c\/p\u003e\n\u003cp\u003e\u003ca title=\"micro-pump kit\" href=\"\/en-ca\/products\/gas-sensor-micro-pump\"\u003e\u003cstrong\u003eMicro-Pump Kit\u003c\/strong\u003e\u003c\/a\u003e\u003cspan\u003e \u003c\/span\u003eincludes all the tools you need to utilize the tube-cap adapters as part of a sampling sensor system.\u003c\/p\u003e\n\u003cp\u003e\u003ca title=\"nafion tubing\" href=\"\/en-ca\/products\/nafion-gas-sample-drying-tubing\"\u003e\u003cstrong\u003eNafion Tubing\u003c\/strong\u003e\u003c\/a\u003e is a highly selective, semi-permeable membrane to water vapor. If gases inside Nafion tubing are wetter than gases surrounding the tubing, drying will occur. If the surrounding gases are wetter, humidification will occur.\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"\/en-ca\/products\/gas-sampling-pump\"\u003e\u003cstrong\u003eMicro Gas Sampling Pumps\u003c\/strong\u003e\u003c\/a\u003e provides a constant flow of air across the sensor with a tube cap - perfect for bench-top testing of sensors for closed-loop sampling applications.\u003c\/p\u003e\n\u003c\/div\u003e","brand":"GSS","offers":[{"title":"SPRINTIR-R-20: 20% CO2 Sensor only","offer_id":43960917459142,"sku":"SPRINTIR-R-20","price":362.0,"currency_code":"USD","in_stock":true},{"title":"CM-20420: 20% CO2 Sensor w\/ MX Board","offer_id":43960917491910,"sku":"CM-20420","price":527.0,"currency_code":"USD","in_stock":false},{"title":"CM-20421: 20% CO2 Sensor and Development Kit","offer_id":43960917524678,"sku":"CM-20421","price":549.0,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/SPRINTIR-R-20lCO2Meter.jpg?v=1753284094"},{"product_id":"copy-of-sprintir-r-100-co2-sensor","title":"SprintIR®-R 100% CO2 Sensor","description":"\u003cp\u003eThe \u003cspan style=\"color: #115e67;\"\u003e\u003cstrong\u003eSprintIR®-R-100 CO2 Sensor\u003c\/strong\u003e\u003c\/span\u003e (\u003cem\u003eformerly known as the GC-0033)\u003c\/em\u003e is a 100% CO2 sensor designed to take 50 readings per second. This makes it the fastest, high-CO2 sensor on the market. Typical applications for this sensor include high-speed food packaging, MAP or headspace gas sampling in bottling plants.\u003c\/p\u003e\n\u003cp\u003eThis sensor is fitted with a standard flow-through adaptor so the CO2 gas can be passed over the optical sensor at high speed using an optional micro-pump.\u003c\/p\u003e\n\u003cp\u003eThe SprintIR®-R-100 uses patented NDIR solid-state LED optical technology enabling the sensor to respond to rapidly changing CO2 without compromising performance.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMeasures up to 100% CO2 Concentration\u003c\/li\u003e\n\u003cli\u003eUltra-fast response rate - 50 Hz\u003c\/li\u003e\n\u003cli\u003eSolid-state, no moving parts, no heated filaments\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eDigital (UART) output\u003c\/li\u003e\n\u003cli\u003eRoHS and REACH compliant\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eModels\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSPRINTIR-R-100 100% Sensor\u003c\/strong\u003e – for integration into high-volume OEM products.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSensor Development Kit\u003c\/strong\u003e (CM-200) - Easy to use, simply plug the sensor into the PCB and plug it into your PC via USB. Use our free \u003ca href=\"\/en-ca\/pages\/downloads\" title=\"Gaslab software\"\u003eGasLab® software\u003c\/a\u003e to measure and graph carbon dioxide or use our \u003ca href=\"https:\/\/github.com\/co2meter-org\/ExampleCode\" title=\"Source code on Github\" rel=\"noopener\" target=\"_blank\"\u003elibrary of source code on Github\u003c\/a\u003e to build your own application or for OEM batch testing\/configuration. Order sensors on this page, then \u003ca href=\"https:\/\/www.co2meter.com\/products\/gas-sensor-development-kit\" title=\"Gas Sensor Development Kit\"\u003eorder the Devkit here\u003c\/a\u003e.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan style=\"color: #286adc;\"\u003e\u003cstrong\u003eWe recommend that all first time users purchase both this sensor and the CM-200 Development Kit for fastest and easiest results.\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cdiv class=\"specifications\"\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCO2 Sensing Method: \u003c\/strong\u003ePatented solid-state NDIR absorption\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSample Method:\u003c\/strong\u003e Flow through adapter\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMeasurement Range:\u003c\/strong\u003e 0-100%\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAccuracy:\u003c\/strong\u003e 0-100% ±300ppm +\/- 5% of reading @ STP\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTime of 1st Reading: \u003c\/strong\u003e\u0026lt;0.2 seconds\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eReadings per Second: \u003c\/strong\u003e50\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eResolution:\u003c\/strong\u003e 100ppm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMeasurement Noise:\u003c\/strong\u003e \u0026lt; 10% of reading with no digital filtering\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePressure Dependence:\u003c\/strong\u003e 500mbar to 2bar\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWarm-up Time:\u003c\/strong\u003e \u0026lt; 30s.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eResponse Time:\u003c\/strong\u003e Flow Rate Dependent\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating Conditions:\u003c\/strong\u003e 0°C to 50°C, 0 to 95% RH, non-condensing\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStorage Conditions: \u003c\/strong\u003e-30°C to +70°C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDimensions: \u003c\/strong\u003e23.8mm x 24mm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight: \u003c\/strong\u003e7.5g\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSensor Life Expectancy:\u003c\/strong\u003e \u0026gt;15 years\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eElectrical \/ Mechanical\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Input:\u003c\/strong\u003e 3.25V to 5.5V (3.3V recommended)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePeak Current:\u003c\/strong\u003e Average Current: \u0026lt;15mA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Consumption:\u003c\/strong\u003e 100mW @ 3.3V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMeasurement Output\/Interface:\u003c\/strong\u003e UART\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eWarranty\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e90 days - See\u003ca href=\"https:\/\/www.co2meter.com\/pages\/terms-conditions\" title=\"Terms and Conditions\"\u003e CO2Meter Terms and Conditions\u003c\/a\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"documents\"\u003e\n\u003ch3\u003eDocuments\u003c\/h3\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/SprintIR-R_Data_Sheet_Rev_4.12_-_Updated_Logo.pdf?v=1751034701\" title=\"GSS and CO2Meter Product Flyer\"\u003e\u003cimg alt=\"SprintIR R Data Sheet\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/CO2METER_PDF.png?1094\"\u003e\u003cstrong\u003e\u003cspan style=\"color: red;\"\u003e Data Sheet (pdf)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca title=\"GSS and CO2Meter User Manual and Data Sheet\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/SprintIR-R_Data_Sheet_Rev_4.12_-_Updated_Logo.pdf?v=1751034701\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/CO2METER_PDF.png?1094\" alt=\"MinIR Manual\"\u003e\u003c\/a\u003e\u003ca title=\"GSS and CO2Meter User Manual\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/SprintIR-R_Data_Sheet_Rev_4.12_3.pdf\"\u003e\u003cstrong\u003e\u003cspan style=\"color: red;\"\u003e Sensor Manual (pdf)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/Mechanical_Diagram_-SprintIR-6S-CO2Meter.pdf\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/CO2METER_PDF.png?1094\" alt=\"Mechanical Diagram\"\u003e\u003cstrong\u003e\u003cspan style=\"color: red;\"\u003e Mechanical Diagram (pdf)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/GSS-Certification.pdf?v=1650749519\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/CO2METER_PDF.png?1094\" alt=\"Quality Certificate\"\u003e\u003cstrong\u003e\u003cspan style=\"color: red;\"\u003e Quality Certificate ISO9001 (pdf)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/AN015_Using_a_pump_to_sample_gas_Application_Note_Rev_1.1.pdf?v=1651156092\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/CO2METER_PDF.png?1094\" alt=\"\"\u003e\u003cstrong\u003e\u003cspan style=\"color: red;\"\u003e GSS Guide for Sample Draw Pumps (pdf)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"\/en-ca\/pages\/co2meter-resources\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/CO2METER_PDF.png?1094\" alt=\"\"\u003e\u003cstrong\u003e\u003cspan style=\"color: red;\"\u003e Additional Application Notes\u003c\/span\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"software\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv class=\"accessories\"\u003e\n\u003cp\u003e\u003ca title=\"CO2Meter Gas Sensor Development Kit\" href=\"https:\/\/www.co2meter.com\/products\/gas-sensor-development-kit\"\u003e\u003cstrong\u003eGas Sensor Development Kit\u003c\/strong\u003e (CM-200)\u003c\/a\u003e- designed to provide customers with an easy drop-in solution. Includes our free \u003ca href=\"https:\/\/www.co2meter.com\/pages\/downloads\" title=\"Gaslab data logging software\"\u003eGaslab data logging software\u003c\/a\u003e. Sensor sold separately.\u003c\/p\u003e\n\u003cp\u003e\u003ca title=\"micro-pump kit\" href=\"\/en-ca\/products\/gas-sensor-micro-pump\"\u003e\u003cstrong\u003eMicro-Pump Kit\u003c\/strong\u003e\u003c\/a\u003e\u003cspan\u003e \u003c\/span\u003eincludes all the tools you need to utilize the tube-cap adapters as part of a sampling sensor system.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003ca title=\"nafion tubing\" href=\"\/en-ca\/products\/nafion-gas-sample-drying-tubing\"\u003eNafion Tubing\u003c\/a\u003e \u003c\/strong\u003eis a highly selective, semi-permeable membrane to water vapor. If gases inside Nafion tubing are wetter than gases surrounding the tubing, drying will occur. If the surrounding gases are wetter, humidification will occur.\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"\/en-ca\/products\/gas-sampling-pump\"\u003e\u003cstrong\u003eMicro Gas Sampling Pumps\u003c\/strong\u003e\u003c\/a\u003e\u003cspan\u003e \u003c\/span\u003eprovide a constant flow of air across the sensor with a tube cap - perfect for bench-top testing of sensors for closed-loop sampling applications.\u003c\/p\u003e\n\u003c\/div\u003e","brand":"GSS","offers":[{"title":"SPRINTIR-R-100: 100% SPRINTIR-R CO2 Sensor","offer_id":43961139527878,"sku":"SPRINTIR-R-100","price":362.0,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/SPRINTIR-R-100lCO2Meter.jpg?v=1753284093"},{"product_id":"copy-of-cozir-lp-miniature-5-000ppm-co2-sensor","title":"CozIR®-LP2 5000ppm CO2 Sensor","description":"\u003cp\u003eThe \u003cspan style=\"color: #115e67;\"\u003e\u003cstrong\u003eCozIR®-LP2-5000 \u003c\/strong\u003e\u003c\/span\u003e(\u003cem\u003eformerly known as the GC-0034)\u003c\/em\u003e\u003cstrong\u003e \u003c\/strong\u003eholds the lowest power and longest lifespan of an infrared CO2 sensor available today. \u003cspan\u003eThis sensor is perfect for IAQ, DCV and HVAC applications or gas monitoring detection systems.\u003c\/span\u003e\u003c\/p\u003e\n\u003cdiv\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMeasures up to 1% CO2 concentration\u003c\/li\u003e\n\u003cli\u003eDigital (UART) and I2C Output\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eUp to 50X lower power than typical NDIR CO2 Sensors\u003c\/li\u003e\n\u003cli\u003eSupports energy-efficient smart home environments\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eModels\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cb\u003eCOZIR\u003c\/b\u003e\u003cstrong\u003e®-LP2-5000\u003c\/strong\u003e – designed for low concentration CO2 environments with measurement ranges from 0-2000 ppm, 0-5000 ppm, and 0-1%.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"specifications\"\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCO2 Measurement: \u003c\/strong\u003ePatented Solid-state NDIR absorption\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSample Method:\u003c\/strong\u003e Diffusion\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMeasurement Range:\u003c\/strong\u003e 0-2,000 ppm, 0-5000 ppm, 0-1%\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAccuracy:\u003c\/strong\u003e ±(30ppm, +3% of reading)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTime to 1st Reading: \u003c\/strong\u003e\u0026lt;1 second\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCalibration:\u003c\/strong\u003e Auto calibration\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eResolution:\u003c\/strong\u003e 1ppm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePressure dependence:\u003c\/strong\u003e 0.15% of reading per mbar (normal atmospheric)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating pressure range:\u003c\/strong\u003e 500mbar – 10 bar\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eResponse time:\u003c\/strong\u003e \u0026lt;30 secs (diffusion limited)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSensor Life Expectancy:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e\u0026gt; 15 years\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eElectrical\/Mechanical\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Input:\u003c\/strong\u003e 3.25 to 5.5V. (3.3V recommended)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Consumption:\u003c\/strong\u003e \u0026lt;3.5mW @ 3.3V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnector:\u003c\/strong\u003e 2 x 6-way 1.27mm header\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCommunication:\u003c\/strong\u003e UART, I2C\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eWarranty\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e90 days - See \u003ca title=\"CO2Meter Terms and Conditions\" href=\"https:\/\/www.co2meter.com\/pages\/terms-conditions\"\u003e\u003cstrong\u003eCO2Meter Terms and Conditions.\u003c\/strong\u003e\u003c\/a\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"documents\"\u003e\n\u003ch3\u003eDocuments\u003c\/h3\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/Datasheet_COZIR_LP2_CO2Meter_4_15_1_-compressed_1.pdf?v=1755542457\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/CO2METER_PDF.png?1093\" alt=\"Datasheet\"\u003e\u003cstrong\u003e\u003cspan style=\"color: red;\"\u003e Data Sheet (pdf) \u003c\/span\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/CozIR-LP2_Data_Sheet_Rev_4.12_-_Updated_Logo.pdf?v=1751037225\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/CO2METER_PDF.png?1093\" alt=\"User Guide\"\u003e \u003cstrong\u003e\u003cspan style=\"color: red;\"\u003e Manual (pdf)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/GSS-Certification.pdf?v=1650749519\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/CO2METER_PDF.png?1093\" alt=\"Quality Certificate\"\u003e \u003cstrong\u003e\u003cspan style=\"color: red;\"\u003e Quality Certificate ISO9001 (pdf)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/Mechanical_Diagram_-_CozIR-LP2-CO2Meter.pdf\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/CO2METER_PDF.png?1093\" alt=\"CozirLP2 Dimensional Drawings\"\u003e\u003cstrong\u003e\u003cspan style=\"color: red;\"\u003e Dimensional Drawings (pdf)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cbr\u003e\u003cstrong\u003eCase Studies\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003ca title=\"CO2 Buildup and Mask Respiration\" href=\"\/en-ca\/blogs\/news\/measuring-co2-levels-in-mask-respiration\"\u003eMeasuring CO2 Buildup and Mask Respiration\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"software\"\u003e\n\u003ch3\u003eFree Easy-to-use GasLab® Software \u003c\/h3\u003e\n\u003cp\u003eThis device uses GasLab® software for setup, calibration, data logging, and real-time data analysis. GasLab® makes it easy to export data into a .CSV file that can be imported into any industry-standard software or spreadsheet. GasLab® runs on Windows XP or higher, and free to use with our products.\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"\/en-ca\/pages\/downloads\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/download-drivers.gif?1253980035\" alt=\"Download Latest Software Here\"\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003ch3\u003eSystem Requirements for Data Logging or Changing Defaults\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eWindows XP SP2 or newer\u003c\/li\u003e\n\u003cli\u003eMicrosoft .Net 3.5 Runtime Libraries\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"accessories\"\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cbr\u003e\n\u003c\/div\u003e","brand":"GSS","offers":[{"title":"CozIR®-LP2-5000: 5000ppm CO2 Sensor","offer_id":30292111589494,"sku":"COZIR-LP2-5000","price":87.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/COZIR-LP2.jpg?v=1753284092"},{"product_id":"gss-co2meter-cozir-blink-co2-sensor","title":"CozIR®-Blink Sensor","description":"\u003cp\u003eThe \u003cstrong\u003e\u003cspan style=\"color: #115e67;\"\u003eCozIR®-Blink\u003c\/span\u003e \u003c\/strong\u003e(formerly known as the GC-0035) is an ultra low power CO2 sensor that enables customers to reduce power consumption of CO2 measurements to zero.  This allows full control of energy trade-offs for ultra-low power environments and applications.\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eGSS designed this CO2 sensor specifically for low power applications. \u003c\/span\u003e The CO2 module can be power cycled, allowing the user to wake up the unit from a dormant state, take a reading, and then power it down completely again.\u003c\/p\u003e\n\u003cdiv\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMeasures up to 1% CO2 concentration\u003c\/li\u003e\n\u003cli\u003eDigital (UART) and I2C Output\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eExtremely low power and energy consumption (32 mJ per measurement)\u003c\/li\u003e\n\u003cli\u003eIntegrates into smart-home environments, HVAC, Building Automation, Instrumentation, Agriculture, MAP, Automotive, Aerospace, and Safety.\u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eModels\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCOZIR-BLINK\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e–\u003cspan\u003e designed as a solid-state technology that enables best-in-class power consumption, durability, and lifespan.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"specifications\"\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCO2 Measurement: \u003c\/strong\u003ePatented Solid-state NDIR absorption\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSample Method:\u003c\/strong\u003e Solid-state LED NDIR Diffusion\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMeasurement Range:\u003c\/strong\u003e 0-2,000 ppm, 0-5000 ppm, 0-1%\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating Conditions - Temperature: \u003c\/strong\u003e0°C to 50°C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStorage Conditions - Temperature: \u003c\/strong\u003e-40°C to +70°C\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating Conditions - Humidity: \u003c\/strong\u003e0-95% RH, non-condensing\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAccuracy:\u003c\/strong\u003e ±(30ppm, +3% of reading)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eResolution:\u003c\/strong\u003e 1ppm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCalibration:\u003c\/strong\u003e Auto calibration\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnvironmental Compliance\u003c\/strong\u003e: RoHS and REACH\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePressure dependence:\u003c\/strong\u003e 0.15% of reading per mbar in normal atmospheric conditions\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating pressure range:\u003c\/strong\u003e 500mbar – 10 bar\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eResponse time:\u003c\/strong\u003e \u0026lt;30 seconds (diffusion limited)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTime to 1st Reading: \u003c\/strong\u003e\u0026lt;1.2 Seconds\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSensor Life Expectancy\u003c\/strong\u003e\u003cspan\u003e\u003cstrong\u003e:\u003c\/strong\u003e \u003c\/span\u003e\u0026gt;15 years\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDimensions: \u003c\/strong\u003e31mm x 19.5mm x 12.7mm, 5g (Pinned) \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eElectrical\/Mechanical\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Input:\u003c\/strong\u003e 3.25 to 5.5V (3.3V recommended)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Consumption:\u003c\/strong\u003e \u0026lt;3.5mW @ 3.3V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnector:\u003c\/strong\u003e 2 x 6-way 1.27mm header\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCommunication:\u003c\/strong\u003e UART\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eWarranty\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e90 days - See \u003ca title=\"CO2Meter Terms and Conditions\" href=\"https:\/\/www.co2meter.com\/pages\/terms-conditions\"\u003e\u003cstrong\u003eCO2Meter Terms and Conditions.\u003c\/strong\u003e\u003c\/a\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"documents\"\u003e\n\u003ch3\u003eDocuments\u003c\/h3\u003e\n\u003cp\u003e\u003ca title=\"CozIR-Blink_DataSheet\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/Datasheet_COZIR_Blink_CO2Meter_4_15_1_-compressed_1.pdf\"\u003e\u003cimg alt=\"Cozir  Blink Datasheet\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/CO2METER_PDF.png?1093\"\u003e\u003cstrong\u003e\u003cspan style=\"color: red;\"\u003e Data Sheet (pdf) \u003c\/span\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/www.gassensing.co.uk\/wp-content\/uploads\/2023\/05\/CozIR-Blink-DataSheet-Rev-4.25_3.pdf\"\u003e\u003cimg alt=\"User Guide\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/CO2METER_PDF.png?1093\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/CozIR-Blink_DataSheet_Rev_4.21_98be7b60-ac50-4074-bb20-6c1d8cd721c4.pdf\" title=\"GSS CO2Meter CoZir-Blink Manual\" target=\"_blank\"\u003e\u003cstrong\u003e\u003cspan style=\"color: red;\"\u003e User Guide (pdf)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan style=\"color: red;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/GSS-Certification.pdf?v=1650749519\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/CO2METER_PDF.png?1094\" alt=\"GSS Quality Certification\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/2027_FM_ISO_Certificate.pdf?v=1742814585\" title=\"ISO Certificate of Conformity\"\u003e Quality Certificate - ISO9001 (pdf)\u003c\/a\u003e\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/Mechanical_Diagram_-_CozIR-Blink-CO2Meter.pdf\"\u003e\u003cimg alt=\"CozIR Blink Dimensional Drawings\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/CO2METER_PDF.png?1093\"\u003e\u003cstrong\u003e\u003cspan style=\"color: red;\"\u003e Dimensional Drawings (pdf)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"\/en-ca\/pages\/co2meter-resources\"\u003eView More GSS CO2 Sensor Application Notes\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e","brand":"GSS","offers":[{"title":"COZIR-BLINK-5000: CozIR®-Blink Sensor","offer_id":30298281738358,"sku":"COZIR-BLINK","price":90.19,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/COZIR-BLINK-5000-CO2Meter.jpg?v=1753284089"},{"product_id":"cozir-lp3-co2-sensor","title":"CozIR®-LP3 Low Power CO2 Sensor","description":"\u003cp\u003eThe \u003cspan style=\"color: #115e67;\"\u003e\u003cstrong\u003eCozIR®-LP3 Low Power CO2 Sensor \u003c\/strong\u003e\u003c\/span\u003e(\u003cem\u003eformerly known as the GC-0036)\u003c\/em\u003e\u003cstrong\u003e \u003c\/strong\u003eholds ultra low power consumption capabilities, with temperature stability, automatic adjustment for altitude, digital alarm, and PWM output.\u003c\/p\u003e\n\u003ch3\u003e\n\u003cspan data-mce-fragment=\"1\"\u003e\u003c\/span\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003c\/span\u003eFeatures\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003cul\u003e\n\u003cli\u003eAnalogue and digital CO2 measurement outputs\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eUser-programmable CO2 level alarm\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eBuilt-in auto-zero function\u003c\/li\u003e\n\u003cli\u003eMiniature, compact size for wireless, portable, wearable, self-powered systems\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eModels\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eCOZIR-LP3 \u003c\/strong\u003e– designed for low concentration CO2 environments with measurement ranges from 0-5000 ppm.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCO2 Measurement:\u003c\/strong\u003e NDIR (Non-Dispersive Infrared)\u003c\/li\u003e\n\u003cli class=\"specifications\"\u003e\n\u003cstrong\u003eSample Method:\u003c\/strong\u003e Solid-state LED NDIR Diffusion\u003c\/li\u003e\n\u003cli class=\"specifications\"\u003e\n\u003cstrong\u003eMeasurement range:\u003c\/strong\u003e 0-2000ppm, 0-5000ppm, 0-1%\u003c\/li\u003e\n\u003cli class=\"specifications\"\u003e\n\u003cstrong\u003eAccuracy: \u003c\/strong\u003e±(30ppm, +3% of reading)\u003c\/li\u003e\n\u003cli class=\"specifications\"\u003e\n\u003cstrong\u003eTime to 1st Reading:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e0.8 seconds minimum\u003c\/li\u003e\n\u003cli class=\"specifications\"\u003e\n\u003cstrong\u003eResponse Time: \u003c\/strong\u003e\u0026lt;30 seconds (diffusion limited)\u003c\/li\u003e\n\u003cli class=\"specifications\"\u003e\n\u003cstrong\u003eSampling Method: \u003c\/strong\u003eSolid-state LED NDIR diffusion\u003c\/li\u003e\n\u003cli class=\"specifications\"\u003e\n\u003cstrong\u003eMeasurement Output: \u003c\/strong\u003eAnalogue or Digital (UART and I2C)\u003c\/li\u003e\n\u003cli class=\"specifications\"\u003e\n\u003cstrong\u003eUltra-low-power:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e\u0026lt;3.5mW average\u003c\/li\u003e\n\u003cli class=\"specifications\"\u003e\n\u003cstrong\u003eResolution:\u003c\/strong\u003e 1 ppm\u003c\/li\u003e\n\u003cli class=\"specifications\"\u003e\n\u003cstrong\u003eOperating Conditions - Temperature:\u003c\/strong\u003e 32° F to 122° F (0° C to 50° C)\u003cbr\u003e\u003cstrong\u003eOperating Conditions - Humidity:\u003c\/strong\u003e 0-95% RH, non-condensing\u003c\/li\u003e\n\u003cli class=\"specifications\"\u003e\n\u003cstrong\u003eStorage Conditions - Temperature: \u003c\/strong\u003e-40° F to 158° F (-40° C to 70° C)\u003c\/li\u003e\n\u003cli class=\"specifications\"\u003e\n\u003cstrong\u003eOperating Pressure:\u003c\/strong\u003e 500 mbar - 2 bar\u003c\/li\u003e\n\u003cli class=\"specifications\"\u003e\n\u003cstrong\u003eEnvironmental Compliance:\u003c\/strong\u003e RoHS3 and REACH\u003c\/li\u003e\n\u003cli class=\"specifications\"\u003e\n\u003cstrong\u003eSensor Life Expectancy:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e\u0026gt; 15 years\n\u003cul\u003e\u003c\/ul\u003e\n\u003ch3\u003e\u003cbr\u003e\u003c\/h3\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eElectrical\/Mechanical\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMeasurement Output:\u003c\/strong\u003e Analogue or Digital (UART and I2C)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSupply Voltage:\u003c\/strong\u003e 3.25 V - 5.5 V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Consumption:\u003c\/strong\u003e 3.5 mW active, 3 µW in low-power mode\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDimensions:\u003c\/strong\u003e 1.5 in. x 0.7 in. x 0.4 in. (38.62mm x 19.5mm x 9.3mm)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e 0.005 lbs. (~2.5g)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cbr\u003e\u003c\/h3\u003e\n\u003ch3\u003eWarranty\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli style=\"list-style-type: none;\"\u003e\n\u003cul\u003e\n\u003cli\u003e90 days - See \u003ca title=\"Visit the CO2Meter Terms and Conditions\" href=\"https:\/\/www.co2meter.com\/pages\/terms-conditions\"\u003eCO2Meter Terms and Conditions.\u003c\/a\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv class=\"documents\"\u003e\n\u003ch3\u003eDocuments\u003c\/h3\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/CozIR-LP3_Data_Sheet_Rev_4.9_-_Updated_Logo.pdf?v=1751036738\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/CO2METER_PDF.png?1093\" alt=\"Datasheet\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/CozIR-LP3_Data_Sheet_Rev_4.9_-_Updated_Logo.pdf?v=1751036738\" title=\"Data Sheet\" target=\"_blank\"\u003e\u003cstrong\u003e\u003cspan style=\"color: red; text-decoration: underline;\"\u003e Data Sheet (pdf) \u003c\/span\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/CozIR-LP3_Data_Sheet_Rev_4.6.pdf?v=1640209967\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/CO2METER_PDF.png?1093\" alt=\"User Guide\"\u003e\u003c\/a\u003e\u003ca title=\"GC-0036 Manual\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/CozIR-LP3_Data_Sheet_Rev_4.6.pdf?v=1695834654\" target=\"_blank\"\u003e\u003cstrong\u003e\u003cspan style=\"color: red; text-decoration: underline;\"\u003e Manual (pdf) \u003c\/span\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/Mechanical_Diagrams_LP3.pdf\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/CO2METER_PDF.png?1093\" alt=\"CozirLP2 Dimensional Drawings\"\u003e\u003cspan style=\"text-decoration: underline; color: red;\"\u003e\u003cstrong\u003e Dimensional Drawings (pdf)\u003c\/strong\u003e\u003c\/span\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"\/en-ca\/pages\/co2meter-resources\"\u003eView GSS CO2 Sensor Application Notes here.\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e","brand":"GSS","offers":[{"title":"CozIR®-LP3 CO2 Sensor","offer_id":32074932781174,"sku":"COZIR-LP3","price":87.99,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/CozIR-LP3-CO2Meter.jpg?v=1761745421"},{"product_id":"004-0-0010-senseair-s8-commercial-co2-sensor","title":"004-0-0010 Senseair Commercial CO2 Sensor","description":"\u003cp\u003eThe \u003cstrong\u003eSensesair S8 Commercial CO2 Sensor\u003c\/strong\u003e (004-0-0010) is a 0-2,000 ppm sensor designed for simple integration into indoor air products. It can be used in a wide range of applications such as in ventilation control, to improve energy savings, and to ensure a good indoor climate.\u003c\/p\u003e\n\u003cp\u003eThe Senseair S8 Commercial CO2 Sensor module is especially designed for high volume production, with full traceability by sensor serial number on all manufacturing processes and key components. Every sensor is individually calibrated and is provided with UART digital interface. The sensor has an estimated life time of more than 15 years.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMiniature Size\u003c\/li\u003e\n\u003cli\u003eCompliant with ANSI\/ASHRAE Standard 62.1-2022\u003c\/li\u003e\n\u003cli\u003eCompliant with RESET grad B\u003c\/li\u003e\n\u003cli\u003eCompliant with WELL Building Standard® (WELL v2™)\u003c\/li\u003e\n\u003cli\u003eIndividually Calibrated\u003c\/li\u003e\n\u003cli\u003eMaintenance-Free\u003c\/li\u003e\n\u003cli\u003eLong Term Stability\u003c\/li\u003e\n\u003cli\u003eLow Power Consumption\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eModels\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSenseair S8 Commercial CO2 Sensor\u003c\/strong\u003e (004-0-0010) - designed for high volume production with full traceability.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSensor Development Kit\u003c\/strong\u003e (CM-200) - Easy to use, simply plug the sensor into the PCB and plug it into your PC via USB. Use our free \u003ca title=\"Gaslab software\" href=\"\/en-ca\/pages\/downloads\" data-mce-href=\"\/en-ca\/pages\/downloads\"\u003eGasLab® software\u003c\/a\u003e to measure and graph carbon dioxide or to configure the sensor or for data logging or for OEM batch testing\/configuration. Order sensor here, then \u003ca title=\"Gas Sensor Development Kit\" href=\"https:\/\/www.co2meter.com\/products\/gas-sensor-development-kit\"\u003eorder the devkit here\u003c\/a\u003e.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan style=\"color: #286adc;\"\u003e\u003cstrong\u003eWe recommend that all first time users purchase both this sensor and the CM-200 Development Kit for fastest and easiest results.\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cdiv class=\"specifications\"\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCO2 Measurement\u003c\/strong\u003e: non-dispersive infrared (NDIR)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMeasurement Method\u003c\/strong\u003e: diffusion\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMeasurement Range\u003c\/strong\u003e: 400 to 2,000 ppm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCO2 Accuracy\u003c\/strong\u003e: ± 30 ppm ± 3% of reading\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCommunication Options\u003c\/strong\u003e: UART Modbus\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAlarm Output\u003c\/strong\u003e (open collector): Open \u0026gt;1,000 ppm, Closed \u0026lt;800 ppm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePWM Output\u003c\/strong\u003e: 0 to 100 % duty cycle for 0 to 2,000 ppm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e: 0 to 50°C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDimensions\u003c\/strong\u003e: 8.5 x 33.5 x 20 mm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSensor Life Expectancy\u003c\/strong\u003e: \u0026gt; 15 years\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaintenance Interval\u003c\/strong\u003e: no maintenance required\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSelf-Diagnostics\u003c\/strong\u003e: complete function check on startup\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eElectrical \/ Mechanical\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003ePower Supply: 4.5 V to 5.25 VDC\u003c\/li\u003e\n\u003cli\u003eMax Current: 300 mA\u003c\/li\u003e\n\u003cli\u003ePower Consumption: 300mA peak, 30mA average\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eWarranty\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e90 days - See\u003ca title=\"Terms and Conditions\" href=\"https:\/\/www.co2meter.com\/pages\/terms-conditions\"\u003e CO2Meter Terms and Conditions.\u003c\/a\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"documents\"\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/rmtplusstoragesenseair.blob.core.windows.net\/docs\/Dev\/publicerat\/PSH3444.pdf\"\u003e\u003cimg alt=\"CO2 Sensor Documention\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/CO2METER_PDF.png?1094\"\u003e\u003cstrong\u003e\u003cspan style=\"color: red;\" data-mce-style=\"color: red;\"\u003e S8 Commercial Sensor Datasheet (pdf)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/rmtplusstoragesenseair.blob.core.windows.net\/docs\/publicerat\/PSP103.pdf\"\u003e\u003cimg alt=\"CO2 Sensor Documention\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/CO2METER_PDF.png?1094\"\u003e\u003cstrong\u003e\u003cspan style=\"color: red;\" data-mce-style=\"color: red;\"\u003e S8 Commercial Manual (pdf)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/rmtplusstoragesenseair.blob.core.windows.net\/docs\/Dev\/publicerat\/TDE2067.pdf\"\u003e\u003cimg alt=\"CO2 Sensor Modbus Manual\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/CO2METER_PDF.png?1094\"\u003e\u003cstrong\u003e\u003cspan style=\"color: red;\" data-mce-style=\"color: red;\"\u003e Modbus Manual (pdf)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/rmtplusstoragesenseair.blob.core.windows.net\/docs\/publicerat\/ANO102.pdf\"\u003e\u003cimg alt=\"CO2 Sensor Documentation\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/CO2METER_PDF.png?1094\"\u003e\u003cstrong\u003e\u003cspan style=\"color: red;\" data-mce-style=\"color: red;\"\u003e Handling Manual Sensair S8 (pdf)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/SenseairISO.pdf?v=1613679881\"\u003e\u003cimg alt=\"Senseair ISO Certification\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/CO2METER_PDF.png?1093\"\u003e\u003cstrong\u003e\u003cspan style=\"color: red;\" data-mce-style=\"color: red;\"\u003e Senseair ISO Certification (pdf)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"accessories\"\u003e\n\u003ch3\u003eAccessories\u003c\/h3\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/www.co2meter.com\/products\/gas-sensor-development-kit\" title=\"CO2Meter Gas Sensor Development Kit\"\u003e\u003cstrong\u003eGas Sensor Development Kit\u003c\/strong\u003e (CM-200)\u003c\/a\u003e- designed to provide customers with an easy drop-in solution. Includes our free \u003ca title=\"Gaslab data logging software\" href=\"https:\/\/www.co2meter.com\/pages\/downloads\"\u003eGaslab data logging software\u003c\/a\u003e. Sensor sold separately.\u003c\/p\u003e\n\u003c\/div\u003e","brand":"Senseair","offers":[{"title":"Default Title","offer_id":42820876533958,"sku":"004-0-0010","price":47.0,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/004-0-0010S8CommercialShopifyImage_1.jpg?v=1753284028"},{"product_id":"030-8-0011-k30-extended-range","title":"030-8-0011 K30 Extended Range","description":"\u003cp\u003eThe \u003cstrong\u003eK30 Extended Range Sensor (030-8-0011) \u003c\/strong\u003eis intended to be built into devices that require up to 5,000 ppm CO2 monitoring or measurement.\u003c\/p\u003e\n\u003cp\u003eIt is an accurate, proven, low-cost solution for OEMs who want to integrate CO2 sensing into their products, research, or studies.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eSimple to install, pre-calibrated and ready-to-use\u003c\/li\u003e\n\u003cli\u003eProven reliability, low cost\u003c\/li\u003e\n\u003cli\u003eMaintenance free in normal applications\u003c\/li\u003e\n\u003cli\u003eFlexible analog and digital outputs\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eModels\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eK30 Extended Range CO2 Sensor\u003c\/strong\u003e (030-8-0011) - For integration into high-volume OEM products.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSensor Development Kit\u003c\/strong\u003e (CM-200) - Easy to use, simply plug the sensor into the PCB and plug it into your PC via USB. Use our free \u003ca title=\"Gaslab software\" href=\"\/en-ca\/pages\/downloads\"\u003eGasLab® software\u003c\/a\u003e to measure and graph carbon dioxide or use our \u003ca rel=\"noopener\" title=\"Source code on Github\" href=\"https:\/\/github.com\/co2meter-org\/ExampleCode\" target=\"_blank\"\u003elibrary of source code on Github\u003c\/a\u003e to build your own application or for OEM batch testing\/configuration. Order sensors on this page, then \u003ca title=\"Gas Sensor Development Kit\" href=\"https:\/\/www.co2meter.com\/products\/gas-sensor-development-kit\"\u003eorder the Devkit here\u003c\/a\u003e.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan style=\"color: #286adc;\" data-mce-style=\"color: #286adc;\"\u003e\u003cstrong\u003eWe recommend that all first time users purchase both this sensor and the CM-200 Development Kit for fastest and easiest results.\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cdiv class=\"specifications\"\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eCO2 Measurement: non-dispersive infrared (NDIR)\u003c\/li\u003e\n\u003cli\u003eMeasurement Range: 0 – 5,000ppm, Up to 10,000 ppm extended range\u003c\/li\u003e\n\u003cli\u003eRate of Measurement: 0.5 Hz\u003c\/li\u003e\n\u003cli\u003eResponse Time Diffusion: 20 seconds\u003c\/li\u003e\n\u003cli\u003eWarm-up Time: \u0026lt; 1 min. \u003c\/li\u003e\n\u003cli\u003eOutputs. 2 analog, 2 digital\u003c\/li\u003e\n\u003cli\u003eScalable Analog voltage outputs\u003c\/li\u003e\n\u003cli\u003eOperating Temperature:\u003c\/li\u003e\n\u003cli\u003eOperating Humidity:\u003c\/li\u003e\n\u003cli\u003eRepeatability: ± 20 ppm ± 1 % of measured value within specifications\u003c\/li\u003e\n\u003cli\u003eAccuracy: ± 30 ppm ± 3 % of measured value within specifications\u003c\/li\u003e\n\u003cli\u003eMaintenance Interval: no maintenance required\u003c\/li\u003e\n\u003cli\u003eSelf-Diagnostics: complete function check at startup\u003c\/li\u003e\n\u003cli\u003eABC (Automatic Background Calibration) enabled unless specified\u003c\/li\u003e\n\u003cli\u003eDimensions: 51 mm x 58 mm x 12 mm\u003c\/li\u003e\n\u003cli\u003eSensor Life Expectancy: \u0026gt; 15 years\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eConforms with Standards\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eEmission: EN61000-6-3:2001\u003c\/li\u003e\n\u003cli\u003eImmunity: EN61000-6-2:2001\u003c\/li\u003e\n\u003cli\u003eRoHS directive 2002\/95\/EG\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eElectrical \/ Mechanical\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003ePower Input: 4.5-140 VD C maximum rating (without reverse polarity protection)\u003c\/li\u003e\n\u003cli\u003eCurrent Consumption: 40 mA average,\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eWarranty\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e90 days - See\u003ca title=\"Terms and Conditions\" href=\"https:\/\/www.co2meter.com\/pages\/terms-conditions\"\u003e CO2Meter Terms and Conditions\u003c\/a\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"documents\"\u003e\n\u003cdiv class=\"data-sheets\"\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/rmtplusstoragesenseair.blob.core.windows.net\/docs\/publicerat\/PSH0131.pdf\" data-mce-href=\"https:\/\/rmtplusstoragesenseair.blob.core.windows.net\/docs\/publicerat\/PSH0131.pdf\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/CO2METER_PDF.png?1094\" alt=\"Datasheet\" data-mce-src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/CO2METER_PDF.png?1094\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/rmtplusstoragesenseair.blob.core.windows.net\/docs\/publicerat\/PSH0131.pdf\" data-mce-href=\"https:\/\/rmtplusstoragesenseair.blob.core.windows.net\/docs\/publicerat\/PSH0131.pdf\"\u003e\u003cstrong\u003e\u003cspan style=\"color: red;\" data-mce-style=\"color: red;\"\u003e Data Sheet (pdf)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/DS-SE-0018-K30-CO2-Sensor.pdf?v=1653003999\" data-mce-href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/DS-SE-0018-K30-CO2-Sensor.pdf?v=1653003999\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/CO2METER_PDF.png?1094\" alt=\"Datasheet\" data-mce-src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/CO2METER_PDF.png?1094\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/DS-SenseAir-K30-CO2-Sensor-Revised-2023.pdf?v=1692893893\" data-mce-href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/DS-SenseAir-K30-CO2-Sensor-Revised-2023.pdf?v=1692893893\"\u003e\u003cstrong\u003e\u003cspan style=\"color: red;\" data-mce-style=\"color: red;\"\u003e K30 Terminal Descriptions and Configurations (pdf)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/Drawing_K30_K33_Revised_2023.pdf?v=1692893892\" data-mce-href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/Drawing_K30_K33_Revised_2023.pdf?v=1692893892\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/CO2METER_PDF.png?1094\" alt=\"CO2 sensor drawing\" data-mce-src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/CO2METER_PDF.png?1094\"\u003e\u003cstrong\u003e\u003cspan style=\"color: red;\" data-mce-style=\"color: red;\"\u003e Dimensional Drawings (pdf)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"http:\/\/\/co2meters.com\/Documentation\/Other\/SenseairISO.pdf\" data-mce-href=\"http:\/\/\/co2meters.com\/Documentation\/Other\/SenseairISO.pdf\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/CO2METER_PDF.png?1093\" alt=\"Senseair ISO Certification\" data-mce-src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/CO2METER_PDF.png?1093\"\u003e\u003cstrong\u003e\u003cspan style=\"color: red;\" data-mce-style=\"color: red;\"\u003e Senseair ISO Certification (pdf)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"manuals\"\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/rmtplusstoragesenseair.blob.core.windows.net\/docs\/publicerat\/PSP110.pdf\" data-mce-href=\"https:\/\/rmtplusstoragesenseair.blob.core.windows.net\/docs\/publicerat\/PSP110.pdf\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/CO2METER_PDF.png?1094\" alt=\"Manual\" data-mce-src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/CO2METER_PDF.png?1094\"\u003e\u003cstrong\u003e\u003cspan style=\"color: red;\" data-mce-style=\"color: red;\"\u003e K30 1% Manual (pdf)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/AN145-sensor-development-kit-quick-start-guide.pdf?v=1650749355\" data-mce-href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/AN145-sensor-development-kit-quick-start-guide.pdf?v=1650749355\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/CO2METER_PDF.png?1094\" alt=\"Quick Start Guide\" data-mce-src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/CO2METER_PDF.png?1094\"\u003e\u003cstrong\u003e\u003cspan style=\"color: red;\" data-mce-style=\"color: red;\"\u003e Devkit Quick Start Guide (pdf)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/SenseAirCommGuide.zip?v=1638914112\" data-mce-href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/SenseAirCommGuide.zip?v=1638914112\"\u003e\u003cimg src=\"\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/assets\/zip.gif\" alt=\"\" data-mce-src=\"\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/assets\/zip.gif\"\u003e\u003cstrong\u003e\u003cspan style=\"color: red;\" data-mce-style=\"color: red;\"\u003e I2C \u0026amp; Modbus Communication Manuals (zip)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/AN_SE_0020_Sensor_Calibration_Procedure_2023.pdf?v=1692893892\" data-mce-href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/AN_SE_0020_Sensor_Calibration_Procedure_2023.pdf?v=1692893892\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/CO2METER_PDF.png?1094\" alt=\"\" data-mce-src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/CO2METER_PDF.png?1094\"\u003e\u003cstrong\u003e\u003cspan style=\"color: red;\" data-mce-style=\"color: red;\"\u003e Sensor Calibration Procedure (pdf)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"technical-documents\"\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/rmtplusstoragesenseair.blob.core.windows.net\/docs\/Dev\/publicerat\/TDE2336.pdf\" data-mce-href=\"https:\/\/rmtplusstoragesenseair.blob.core.windows.net\/docs\/Dev\/publicerat\/TDE2336.pdf\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/CO2METER_PDF.png?1094\" alt=\"\" data-mce-src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/CO2METER_PDF.png?1094\"\u003e\u003cstrong\u003e\u003cspan style=\"color: red;\" data-mce-style=\"color: red;\"\u003e Modbus Documentation Flexibility Counts (pdf)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/rmtplusstoragesenseair.blob.core.windows.net\/docs\/Dev\/publicerat\/TDE4700.pdf\" data-mce-href=\"https:\/\/rmtplusstoragesenseair.blob.core.windows.net\/docs\/Dev\/publicerat\/TDE4700.pdf\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/CO2METER_PDF.png?1094\" alt=\"\" data-mce-src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/CO2METER_PDF.png?1094\"\u003e\u003cstrong\u003e\u003cspan style=\"color: red;\" data-mce-style=\"color: red;\"\u003e I2C Communication Guide (pdf)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/AN141-Labview-examples.zip?v=1647477681\" data-mce-href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/AN141-Labview-examples.zip?v=1647477681\"\u003e\u003cimg src=\"\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/assets\/zip.gif\" alt=\"\" data-mce-src=\"\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/assets\/zip.gif\"\u003e\u003cstrong\u003e\u003cspan style=\"color: red;\" data-mce-style=\"color: red;\"\u003e Labview Examples for SenseAir K-30 (zip)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/AN_144_SE_0018_Revised8_CO2Meter.pdf?v=1710164404\" data-mce-href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/AN_144_SE_0018_Revised8_CO2Meter.pdf?v=1710164404\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/CO2METER_PDF.png?1094\" alt=\"\" data-mce-src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/CO2METER_PDF.png?1094\"\u003e\u003cstrong\u003e\u003cspan style=\"color: red;\" data-mce-style=\"color: red;\"\u003e Web Application Using PHP and K30 DevKit (pdf)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/AN137-K30-sensor-raspberry-pi-Revised8.pdf?v=1653006660\" data-mce-href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/AN137-K30-sensor-raspberry-pi-Revised8.pdf?v=1653006660\"\u003e\u003cimg src=\"\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/assets\/zip.gif\" alt=\"\" data-mce-src=\"\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/assets\/zip.gif\"\u003e\u003cstrong\u003e\u003cspan style=\"color: red;\" data-mce-style=\"color: red;\"\u003e Raspberry Pi UART Instructions (pdf)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/AN137-K30-sensor-raspberry-pi.zip?v=1653006700\" data-mce-href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/AN137-K30-sensor-raspberry-pi.zip?v=1653006700\"\u003e\u003cimg src=\"\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/assets\/zip.gif\" alt=\"\" data-mce-src=\"\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/assets\/zip.gif\"\u003e\u003cstrong\u003e\u003cspan style=\"color: red;\" data-mce-style=\"color: red;\"\u003e Raspberry Pi UART Sample Code (zip)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/AN126-K3x-sensor-arduino-uart_2023.pdf?v=1692893893\" data-mce-href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/AN126-K3x-sensor-arduino-uart_2023.pdf?v=1692893893\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/CO2METER_PDF.png?1094\" alt=\"\" data-mce-src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/CO2METER_PDF.png?1094\"\u003e\u003cstrong\u003e\u003cspan style=\"color: red;\" data-mce-style=\"color: red;\"\u003e Arduino UART Instructions (pdf)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/AN126-K3x-sensor-arduino-uart.zip?v=1653006884\" data-mce-href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/AN126-K3x-sensor-arduino-uart.zip?v=1653006884\"\u003e\u003cimg src=\"\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/assets\/zip.gif\" alt=\"\" data-mce-src=\"\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/assets\/zip.gif\"\u003e\u003cstrong\u003e\u003cspan style=\"color: red;\" data-mce-style=\"color: red;\"\u003e Arduino UART Sample Code (zip)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/AN102-K30-Sensor-Arduino-I2C-2023.pdf?v=1692893893\" data-mce-href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/AN102-K30-Sensor-Arduino-I2C-2023.pdf?v=1692893893\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/CO2METER_PDF.png?1094\" alt=\"\" data-mce-src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/CO2METER_PDF.png?1094\"\u003e\u003cstrong\u003e\u003cspan style=\"color: red;\" data-mce-style=\"color: red;\"\u003e Arduino I2C Instructions (pdf)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/AN102-K30-Sensor-Arduino-I2C.zip?v=1653007039\" data-mce-href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/AN102-K30-Sensor-Arduino-I2C.zip?v=1653007039\"\u003e\u003cimg src=\"\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/assets\/zip.gif\" alt=\"\" data-mce-src=\"\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/assets\/zip.gif\"\u003e\u003cstrong\u003e\u003cspan style=\"color: red;\" data-mce-style=\"color: red;\"\u003e Arduino I2C Sample Code (zip)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/AN_144_SE_0018_Revised8_CO2Meter.pdf?v=1710164404\" data-mce-href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/AN_144_SE_0018_Revised8_CO2Meter.pdf?v=1710164404\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/CO2METER_PDF.png?1094\" alt=\"\" data-mce-src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/CO2METER_PDF.png?1094\"\u003e\u003cstrong\u003e\u003cspan style=\"color: red;\" data-mce-style=\"color: red;\"\u003e Troubleshooting Arduino or Raspberry Pi (pdf)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"case-studies\"\u003e\n\u003cp\u003e\u003ca href=\"\/en-ca\/blogs\/news\/6926946-senseair-k30-vaisala-cmm222c-elt-s100-kcd-an100-and-ge-sensing-t6615-sensor-comparison\" title=\"CO2 Sensors compared\" data-mce-href=\"\/en-ca\/blogs\/news\/6926946-senseair-k30-vaisala-cmm222c-elt-s100-kcd-an100-and-ge-sensing-t6615-sensor-comparison\"\u003eSenseAir K30, Vaisala CMM222C, ELT S100, KCD AN100 and GE Sensing T6615 Sensor Comparison\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"\/en-ca\/blogs\/news\/co2-monitoring-and-composting-applications\" title=\"CO2 Monitoring during composting article\" data-mce-href=\"\/en-ca\/blogs\/news\/co2-monitoring-and-composting-applications\"\u003eMonitoring CO2 Levels Critical for Compost Success\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"\/en-ca\/blogs\/news\/10947573-senseairs-co2-sensor-more-accurate-than-ge-other-brands\" title=\"SenseAir CO2 Sensor More Accurate than other brands\" data-mce-href=\"\/en-ca\/blogs\/news\/10947573-senseairs-co2-sensor-more-accurate-than-ge-other-brands\"\u003eStudy Shows SenseAir CO2 Sensor More Accurate than GE, Other Brands\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"\/en-ca\/blogs\/news\/choosing-senseair-k30-co2-sensors\" title=\"Why choose K-30 CO2 Sensor?\" data-mce-href=\"\/en-ca\/blogs\/news\/choosing-senseair-k30-co2-sensors\"\u003eWhitepaper: Why Customers Choose the SenseAir K30 CO2 Sensor\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"\/en-ca\/blogs\/news\/15302513-school-science-fair-project-uses-co2meter-sensors\" title=\"K-30 CO2 sensor school science fair project\" data-mce-href=\"\/en-ca\/blogs\/news\/15302513-school-science-fair-project-uses-co2meter-sensors\"\u003eSchool Science Fair Project Uses SenseAir CO2 Sensors\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"\/en-ca\/blogs\/news\/haney-test-co2-sensor-soil-health\" title=\"Haney test uses CO2 sensor\" data-mce-href=\"\/en-ca\/blogs\/news\/haney-test-co2-sensor-soil-health\"\u003eHaney Test Uses CO2 Sensor to Measure Soil Health\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"\/en-ca\/blogs\/news\/student-science-fair-project-co2-sensor-arduino\" title=\"K30 sensor and Arduino Uno\" data-mce-href=\"\/en-ca\/blogs\/news\/student-science-fair-project-co2-sensor-arduino\"\u003eStudent project combines CO2 sensor, Arduino Uno\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"\/en-ca\/blogs\/news\/senseair-co2-sensor-competes-with-crds-unit-that-costs-thousands-more\" title=\"K30 sensor and CRDS CO2 measurement comparison\" data-mce-href=\"\/en-ca\/blogs\/news\/senseair-co2-sensor-competes-with-crds-unit-that-costs-thousands-more\"\u003eSenseAir CO2 Sensor Competes with CRDS Unit that Costs Thousands More\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"software\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv class=\"accessories\"\u003e\n\u003ch3\u003eAccessories\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/www.co2meter.com\/products\/gas-sensor-development-kit\" title=\"CO2Meter Gas Sensor Development Kit\" data-mce-href=\"https:\/\/www.co2meter.com\/products\/gas-sensor-development-kit\"\u003e\u003cstrong\u003eGas Sensor Development Kit \u003c\/strong\u003e\u003c\/a\u003e- designed to provide customers with an easy drop-in solution. Includes our free \u003ca title=\"Gaslab data logging software\" href=\"https:\/\/www.co2meter.com\/pages\/downloads\" data-mce-href=\"https:\/\/www.co2meter.com\/pages\/downloads\"\u003eGaslab data logging software\u003c\/a\u003e. Sensor sold separately.\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"\/en-ca\/products\/sensor-flow-through-director\" title=\"CO2Meter Sensor Tube Cap Adapter\" data-mce-href=\"\/en-ca\/products\/sensor-flow-through-director\"\u003e\u003cstrong\u003eTube Cap Adapter\u003c\/strong\u003e\u003c\/a\u003e changes the sensor from reading CO2 in the air to a sample draw sensor. Use with a pump, tubing and filters to read CO2 levels in enclosed containers\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"\/en-ca\/products\/gas-sensor-micro-pump\" data-mce-href=\"\/en-ca\/products\/gas-sensor-micro-pump\"\u003e\u003cstrong\u003eSample Draw Pump Kit\u003c\/strong\u003e\u003c\/a\u003e includes all the components you need with a sample draw sensor.\u003c\/li\u003e\n\u003cli\u003e\n\u003ca title=\"View the Probe Enclosure for Development Kits\" href=\"\/en-ca\/products\/probe-enclosure-development-kit\" data-mce-href=\"\/en-ca\/products\/probe-enclosure-development-kit\"\u003e\u003cstrong\u003eProbe Enclosure\u003c\/strong\u003e\u003c\/a\u003e. Includes hydrophobic filters, protects the sensor when used in hostile environments.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cp\u003e\u003cspan style=\"color: #ffffff;\" data-mce-style=\"color: #ffffff;\"\u003ek30 k-30 SE-0018 SE0018 SE018 SE18 Senseair SenseAire\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/div\u003e","brand":"Senseair","offers":[{"title":"Default Title","offer_id":42832600334534,"sku":"030-8-0011","price":78.0,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/030-8-0011.jpg?v=1753284024"},{"product_id":"004-0-0053-senseair-s8-low-power-co2-sensor","title":"Senseair S8 Low Power CO2 Sensor","description":"\u003cp\u003eThe \u003cem\u003e\u003cstrong\u003eSensesair S8 Low Power CO2 Sensor\u003c\/strong\u003e\u003c\/em\u003e module is designed to be used in a wide range of applications where both energy consumption and accuracy are critical factors.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMiniature size\u003c\/li\u003e\n\u003cli\u003eCompliant with ANSI\/ASHRAE Standard 62.1-2022\u003c\/li\u003e\n\u003cli\u003eCompliant with RESET grad B \u003c\/li\u003e\n\u003cli\u003eCompliant with WELL Building Standard® (WELL v2™) \u003c\/li\u003e\n\u003cli\u003eIndividually calibrated\u003c\/li\u003e\n\u003cli\u003eMaintenance-free\u003c\/li\u003e\n\u003cli\u003eLong term stability\u003c\/li\u003e\n\u003cli\u003eLow power consumption\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eModels\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e004-0-0053 Senseair S8 Low Power CO2 Sensor\u003c\/strong\u003e - designed for high volume production with focus on energy consumption and accuracy.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e004-0-0073 Senseair S8 Low Power CO2 Sensor w\/ PINS\u003c\/strong\u003e - designed for high volume production with focus on energy consumption and accuracy.\u003c\/p\u003e\n\u003cdiv class=\"specifications\"\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\nCO2 Measurement: non-dispersive infrared (NDIR)\u003c\/div\u003e\n\u003cdiv class=\"specifications\"\u003eMeasurement Method: diffusion\u003c\/div\u003e\n\u003cdiv class=\"specifications\"\u003eMeasurement Range: 400 to 2,000 ppm, 0 to 10,000ppm\u003c\/div\u003e\n\u003cdiv class=\"specifications\"\u003eCO2 Accuracy: ± 40 ppm ± 3% of reading\u003cbr\u003eCommunication Options: UART Modbus\u003c\/div\u003e\n\u003cdiv class=\"specifications\"\u003eAlarm Output (open collector): Open \u0026gt; 1,000ppm, Closed \u0026lt;800 ppm\u003c\/div\u003e\n\u003cdiv class=\"specifications\"\u003ePWM Output: 0 to 100 % duty cycle for 0 to 2,000ppm\u003c\/div\u003e\n\u003cdiv class=\"specifications\"\u003eOperating Temperature: \u003cspan data-mce-fragment=\"1\"\u003e\u003cspan dir=\"ltr\" class=\"ui-provider ec bqc bqd bqe bqf bqg bqh bqi bqj bqk bql bqm bqn bqo bqp bqq bqr bqs bqt bqu bqv bqw bqx bqy bqz bra brb brc brd bre brf brg brh bri brj\" data-mce-fragment=\"1\"\u003e0 to 50°C\u003c\/span\u003e\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"specifications\"\u003eDimensions: 8.5 x 33.5 x 20 mm\u003c\/div\u003e\n\u003cdiv class=\"specifications\"\u003eSensor Life Expectancy: \u0026gt; 15 years\u003c\/div\u003e\n\u003cdiv class=\"specifications\"\u003eMaintenance Interval: no maintenance required for normal applications with ABC on\u003c\/div\u003e\n\u003cdiv class=\"specifications\"\u003eSelf-Diagnostics: complete function check on startup\u003c\/div\u003e\n\u003cdiv class=\"specifications\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv class=\"specifications\"\u003e\n\u003ch3\u003eElectrical \/ Mechanical\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003ePower Supply: \u003cspan data-mce-fragment=\"1\"\u003e\u003cspan dir=\"ltr\" class=\"ui-provider ec bqc bqd bqe bqf bqg bqh bqi bqj bqk bql bqm bqn bqo bqp bqq bqr bqs bqt bqu bqv bqw bqx bqy bqz bra brb brc brd bre brf brg brh bri brj\" data-mce-fragment=\"1\"\u003e4.5 V to 5.25  V DC\u003c\/span\u003e\u003c\/span\u003e\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eMax Current: 300 mA \u0026lt; 18mA average.\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003ePower Consumption: 300mA peak, 30mA average\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eWarranty\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e90 days - See \u003ca title=\"See CO2Meter Terms and Conditions\" href=\"https:\/\/www.co2meter.com\/pages\/terms-conditions\"\u003eCO2Meter Terms and Conditions.\u003c\/a\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"documents\"\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/rmtplusstoragesenseair.blob.core.windows.net\/docs\/Dev\/publicerat\/PSH1944.pdf\"\u003e\u003cimg alt=\"CO2 Sensor Documention\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/CO2METER_PDF.png?1094\"\u003e\u003cstrong\u003e\u003cspan style=\"color: red;\"\u003e S8 Sensor Datasheet (pdf)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/rmtplusstoragesenseair.blob.core.windows.net\/docs\/publicerat\/PSP126.pdf\"\u003e\u003cimg alt=\"CO2 Sensor Documention\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/CO2METER_PDF.png?1094\"\u003e\u003cstrong\u003e\u003cspan style=\"color: red;\"\u003e S8 Sensor Manual (pdf)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/rmtplusstoragesenseair.blob.core.windows.net\/docs\/publicerat\/ANO102.pdf\"\u003e\u003cimg alt=\"CO2 Sensor Documentation\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/CO2METER_PDF.png?1094\"\u003e\u003cstrong\u003e\u003cspan style=\"color: red;\"\u003e Handling Manual Sensair S8 (pdf)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/SenseairISO.pdf?v=1613679881\"\u003e\u003cimg alt=\"Senseair ISO Certification\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/CO2METER_PDF.png?1093\"\u003e\u003cstrong\u003e\u003cspan style=\"color: red;\"\u003e Senseair ISO Certification (pdf)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e","brand":"Senseair","offers":[{"title":"004-0-0053 Senseair Low Power CO2 Sensor","offer_id":42836020691142,"sku":"004-0-0053","price":46.0,"currency_code":"USD","in_stock":false},{"title":"004-0-0073 Senseair Low Power CO2 Sensor w\/ PINS","offer_id":42846001234118,"sku":"004-0-0073","price":67.1,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/004-0-0053-S8-CO2-Sensor.jpg?v=1753284023"},{"product_id":"004-0-0017-s8-alarm-5-co2-sensor","title":"004-0-0017 S8 Alarm 5% CO2 Sensor","description":"\u003cp\u003eThe \u003cstrong\u003eS8 5% Alarm CO2 Sensor \u003c\/strong\u003e(004-0-0017) is designed to act like a safety switch for alarm applications where CO2 leak detection around tanks or cylinders of compressed CO2 gas is required. It comes with Automatic Background Calibration (ABC) turned on.\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003e\u003c\/em\u003eThanks to a new optical path design, the S8 can accurately measure carbon dioxide levels up to 5%, yet it has less than a 30x20x10mm footprint and runs on only 30mA.\u003c\/p\u003e\n\u003cp\u003eThis sensor is designed for commercial applications. It provides simple communication via UART which lets you change the measurement period and control the ABC period in real time. Background and zero-gas calibrations are also implemented in a simple manner.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eLow Power, Small Footprint Design\u003c\/li\u003e\n\u003cli\u003eAutomatic Background Calibration\u003c\/li\u003e\n\u003cli\u003eIndustry-Standard UART Communication\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eModels\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eS8 Alarm 0-5% CO2 Sensor\u003c\/strong\u003e (004-0-0017) - pinless design for integration into high-volume OEM products. \u003cstrong\u003eABC on.\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSensor Development Kit\u003c\/strong\u003e (CM-200) - Easy to use, simply plug the sensor into the PCB and plug it into your PC via USB. Use our free \u003ca href=\"\/en-ca\/pages\/downloads\" title=\"Gaslab software\"\u003eGasLab® software\u003c\/a\u003e to measure and graph carbon dioxide or use our \u003ca href=\"https:\/\/github.com\/co2meter-org\/ExampleCode\" title=\"Source code on Github\" rel=\"noopener\" target=\"_blank\"\u003elibrary of source code on Github\u003c\/a\u003e to build your own application or for OEM batch testing\/configuration. Order the sensor on this page, then \u003ca href=\"https:\/\/www.co2meter.com\/products\/gas-sensor-development-kit\" title=\"Gas Sensor Development Kit\"\u003eorder the Devkit here\u003c\/a\u003e.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan style=\"color: #286adc;\" data-mce-style=\"color: #286adc;\"\u003e\u003cstrong\u003eWe recommend that all first time users purchase both this sensor and the CM-200 Development Kit for fastest and easiest results.\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cdiv class=\"specifications\"\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCO2 Measurement\u003c\/strong\u003e: non-dispersive infrared (NDIR)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMeasurement Method\u003c\/strong\u003e: Diffusion\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMeasurement Range\u003c\/strong\u003e: 0-5% (0-50,000ppm)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eResponse time\u003c\/strong\u003e: 90% at 2 minutes\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRate of Measurement\u003c\/strong\u003e: \u003cspan\u003e 0.5 Hz (every 2 seconds)\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAccuracy\u003c\/strong\u003e: ± 200ppm ± 10% of measured value\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAvailable Output\u003c\/strong\u003e: analog\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCommunication Options\u003c\/strong\u003e: UART Modbus\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSensor Life Expectancy\u003c\/strong\u003e: \u0026gt; 15 years\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaintenance Interval\u003c\/strong\u003e: no maintenance required\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSelf-Diagnostics\u003c\/strong\u003e: complete function check on startup\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eElectrical \/ Mechanical\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eDimensions\u003c\/strong\u003e: 32.7 × 19.7 × 8 mm (LxWxH)  \u0026lt; 8 grams.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Input\u003c\/strong\u003e: 4.5-5.25 VDC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMax Current\u003c\/strong\u003e: 300 mA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Consumption\u003c\/strong\u003e: 300mA peak, 30mA average\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eWarranty\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e90 days - See\u003ca href=\"https:\/\/www.co2meter.com\/pages\/terms-conditions\" title=\"Terms and Conditions\"\u003e CO2Meter Terms and Conditions.\u003c\/a\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"documents\"\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/rmtplusstoragesenseair.blob.core.windows.net\/docs\/Dev\/publicerat\/PSH1946.pdf\" data-mce-href=\"https:\/\/rmtplusstoragesenseair.blob.core.windows.net\/docs\/Dev\/publicerat\/PSH1946.pdf\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/CO2METER_PDF.png?1094\" alt=\"CO2 Sensor Documention\" data-mce-src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/CO2METER_PDF.png?1094\"\u003e\u003c\/a\u003e\u003ca title=\"S8 5% Datasheet\" href=\"https:\/\/rmtplusstoragesenseair.blob.core.windows.net\/docs\/Dev\/publicerat\/PSH1946.pdf\" data-mce-href=\"https:\/\/rmtplusstoragesenseair.blob.core.windows.net\/docs\/Dev\/publicerat\/PSH1946.pdf\" target=\"_blank\"\u003e\u003cstrong\u003e\u003cspan style=\"color: red;\" data-mce-style=\"color: red;\"\u003e S8 5% Datasheet (pdf)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/Manual_Datasheet_SE_0037_Revised8.pdf?v=1653445443\" data-mce-href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/Manual_Datasheet_SE_0037_Revised8.pdf?v=1653445443\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/CO2METER_PDF.png?1094\" alt=\"CO2 Sensor Documention\" data-mce-src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/CO2METER_PDF.png?1094\"\u003e\u003c\/a\u003e\u003ca title=\"S8 Manual\" href=\"https:\/\/rmtplusstoragesenseair.blob.core.windows.net\/docs\/publicerat\/PSP0113.pdf\" data-mce-href=\"https:\/\/rmtplusstoragesenseair.blob.core.windows.net\/docs\/publicerat\/PSP0113.pdf\" target=\"_blank\"\u003e\u003cstrong\u003e\u003cspan style=\"color: red;\" data-mce-style=\"color: red;\"\u003e S8 5% Sensor Manual (pdf)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/Modbus_SE_0119_Revised8.pdf?v=1653445891\" data-mce-href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/Modbus_SE_0119_Revised8.pdf?v=1653445891\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/CO2METER_PDF.png?1094\" alt=\"CO2 Sensor Documention\" data-mce-src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/CO2METER_PDF.png?1094\"\u003e\u003c\/a\u003e\u003cspan style=\"color: #ff2a00;\" data-mce-style=\"color: #ff2a00;\"\u003e\u003cstrong\u003e\u003ca style=\"color: #ff2a00;\" title=\"Modbus Communication\" href=\"chrome-extension:\/\/efaidnbmnnnibpcajpcglclefindmkaj\/https:\/\/rmtplusstoragesenseair.blob.core.windows.net\/docs\/Dev\/publicerat\/TDE2067.pdf\" data-mce-style=\"color: #ff2a00;\" data-mce-href=\"chrome-extension:\/\/efaidnbmnnnibpcajpcglclefindmkaj\/https:\/\/rmtplusstoragesenseair.blob.core.windows.net\/docs\/Dev\/publicerat\/TDE2067.pdf\"\u003e \u003c\/a\u003e\u003ca style=\"color: #ff2a00;\" href=\"https:\/\/rmtplusstoragesenseair.blob.core.windows.net\/docs\/Dev\/publicerat\/TDE2067.pdf\" title=\"Modbus Communication\" data-mce-style=\"color: #ff2a00;\" data-mce-href=\"https:\/\/rmtplusstoragesenseair.blob.core.windows.net\/docs\/Dev\/publicerat\/TDE2067.pdf\" target=\"_blank\"\u003eModbus Communication Manual (pdf)\u003c\/a\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/AN_168_SE_0037_Raspberry_Pi_to_SenseAir_Revised8.pdf?v=1653445714\" data-mce-href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/AN_168_SE_0037_Raspberry_Pi_to_SenseAir_Revised8.pdf?v=1653445714\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/CO2METER_PDF.png?1094\" alt=\"CO2 Sensor Documention\" data-mce-src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/CO2METER_PDF.png?1094\"\u003e\u003cstrong\u003e\u003cspan style=\"color: red;\" data-mce-style=\"color: red;\"\u003e Connecting to Raspberry Pi via UART (pdf)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/AN168-S8-raspberry-pi-files.zip?v=1653445941\" data-mce-href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/AN168-S8-raspberry-pi-files.zip?v=1653445941\"\u003e\u003cimg src=\"\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/assets\/zip.gif\" alt=\"\" data-mce-src=\"\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/assets\/zip.gif\"\u003e\u003cstrong\u003e\u003cspan style=\"color: red;\" data-mce-style=\"color: red;\"\u003e Raspberry Pi Sample Code (ZIP)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/AN162-LP8-sensor-arduino-modbus-uart.pdf?v=1653446032\" data-mce-href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/AN162-LP8-sensor-arduino-modbus-uart.pdf?v=1653446032\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/CO2METER_PDF.png?1094\" alt=\"CO2 Sensor Documentation\" data-mce-src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/CO2METER_PDF.png?1094\"\u003e\u003cstrong\u003e\u003cspan style=\"color: red;\" data-mce-style=\"color: red;\"\u003e Connecting to TI CC3200 WIFI via UART (pdf)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/SenseairISO.pdf?v=1613679881\" data-mce-href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/SenseairISO.pdf?v=1613679881\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/CO2METER_PDF.png?1093\" alt=\"Senseair ISO Certification\" data-mce-src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/CO2METER_PDF.png?1093\"\u003e\u003cstrong\u003e\u003cspan style=\"color: red;\" data-mce-style=\"color: red;\"\u003e Senseair ISO Certification (pdf)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"software\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv class=\"accessories\"\u003e\n\u003ch3\u003eAccessories\u003c\/h3\u003e\n\u003cp\u003e\u003ca title=\"CO2Meter Gas Sensor Development Kit\" href=\"https:\/\/www.co2meter.com\/products\/gas-sensor-development-kit\"\u003e\u003cstrong\u003eGas Sensor Development Kit\u003c\/strong\u003e (CM-200)\u003c\/a\u003e- designed to provide customers with an easy drop-in solution. Includes our free \u003ca href=\"https:\/\/www.co2meter.com\/pages\/downloads\" title=\"Gaslab data logging software\"\u003eGaslab data logging software\u003c\/a\u003e. Sensor sold separately.\u003c\/p\u003e\n\u003c\/div\u003e","brand":"Senseair","offers":[{"title":"Default Title","offer_id":42836192592070,"sku":"004-0-0017","price":48.0,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/004-0-0017ShopifyImage_3aae6bdc-3f7f-4008-b3fb-00c3bdab08a4.jpg?v=1753284021"},{"product_id":"004-0-0050-senseair-2-percent-co2-sensor","title":"004-0-0050 Senseair S8 2% CO2 Sensor","description":"\u003cp\u003eThe\u003cem\u003e \u003c\/em\u003e\u003cstrong\u003eSensesair S8 2% CO2 Sensor\u003c\/strong\u003e (004-0-0050, was SE-0031) is designed to be used in control and alarm applications. This sensor can further be integrated into a wide range of applications including CO2 leak detection.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMiniature size\u003c\/li\u003e\n\u003cli\u003eEasy integration\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eIndividually calibrated\u003c\/li\u003e\n\u003cli\u003eMaintenance-free\u003c\/li\u003e\n\u003cli\u003eLong term stability\u003c\/li\u003e\n\u003cli\u003eLow power consumption\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eModels\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSenseair S8 2% CO2 Sensor\u003c\/strong\u003e (004-0-0050) - for high volume production with focus on control and alarm applications\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSensor Development Kit\u003c\/strong\u003e (CM-200) - Easy to use, simply plug the sensor into the PCB and plug it into your PC via USB. Use our free \u003ca title=\"Gaslab software\" href=\"\/en-ca\/pages\/downloads\"\u003eGasLab® software\u003c\/a\u003e to measure and graph carbon dioxide or use our \u003ca rel=\"noopener\" title=\"Source code on Github\" href=\"https:\/\/github.com\/co2meter-org\/ExampleCode\" target=\"_blank\"\u003elibrary of source code on Github\u003c\/a\u003e to build your own application or for OEM batch testing\/configuration. Order sensors on this page, then \u003ca title=\"Gas Sensor Development Kit\" href=\"https:\/\/www.co2meter.com\/products\/gas-sensor-development-kit\"\u003eorder the Devkit here\u003c\/a\u003e.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan style=\"color: #286adc;\"\u003e\u003cstrong\u003eWe recommend that all first time users purchase both this sensor and the CM-200 Development Kit for fastest and easiest results.\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cdiv class=\"specifications\"\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eCO2 Measurement: non-dispersive infrared (NDIR)\u003c\/li\u003e\n\u003cli\u003eMeasurement Method: diffusion\u003c\/li\u003e\n\u003cli\u003eMeasurement Range: 0.04-2% vol\u003c\/li\u003e\n\u003cli\u003eCO2 Accuracy: ±200ppm ±3% of reading 1, 2\u003c\/li\u003e\n\u003cli\u003eCommunication Options: UART (Modbus)\u003c\/li\u003e\n\u003cli\u003eOperating Temperature: 0 to 50°C\u003c\/li\u003e\n\u003cli\u003eResponse Time: 2 minutes by 90%\u003c\/li\u003e\n\u003cli\u003eDimensions: 8.5 x 33.5 x 20 mm\u003c\/li\u003e\n\u003cli\u003eSensor Life Expectancy: \u0026gt; 15 years\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eElectrical \/ Mechanical\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003ePower Supply:4.5 V to 5.25VDC\u003c\/li\u003e\n\u003cli\u003eMax Current: 300 mA \u0026lt; 18mA average.\u003c\/li\u003e\n\u003cli\u003ePower Consumption: 300mA peak, 30mA average\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eWarranty\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e90 days - See\u003ca href=\"https:\/\/www.co2meter.com\/pages\/terms-conditions\" title=\"Terms and Conditions\"\u003e CO2Meter Terms and Conditions.\u003c\/a\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"documents\"\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/rmtplusstoragesenseair.blob.core.windows.net\/docs\/Dev\/publicerat\/PSH1945.pdf\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/CO2METER_PDF.png?1094\" alt=\"CO2 Sensor Documention\"\u003e\u003cstrong\u003e\u003cspan style=\"color: red;\" data-mce-style=\"color: red;\"\u003e S8 Sensor Datasheet (pdf)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/rmtplusstoragesenseair.blob.core.windows.net\/docs\/publicerat\/PSP108.pdf\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/CO2METER_PDF.png?1094\" alt=\"CO2 Sensor Documention\"\u003e\u003cstrong\u003e\u003cspan style=\"color: red;\" data-mce-style=\"color: red;\"\u003e S8 Sensor Manual (pdf)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/rmtplusstoragesenseair.blob.core.windows.net\/docs\/publicerat\/ANO102.pdf\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/CO2METER_PDF.png?1094\" alt=\"CO2 Sensor Documentation\"\u003e\u003cstrong\u003e\u003cspan style=\"color: red;\" data-mce-style=\"color: red;\"\u003e Handling Manual Sensair S8 (pdf)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/SenseairISO.pdf?v=1613679881\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/CO2METER_PDF.png?1093\" alt=\"Senseair ISO Certification\"\u003e\u003cstrong\u003e\u003cspan style=\"color: red;\" data-mce-style=\"color: red;\"\u003e Senseair ISO Certification (pdf)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"accessories\"\u003e\n\u003ch3\u003eAccessories\u003c\/h3\u003e\n\u003cp\u003e\u003ca title=\"CO2Meter Gas Sensor Development Kit\" href=\"https:\/\/www.co2meter.com\/products\/gas-sensor-development-kit\"\u003e\u003cstrong\u003eGas Sensor Development Kit\u003c\/strong\u003e (CM-200)\u003c\/a\u003e- designed to provide customers with an easy drop-in solution. Includes our free \u003ca href=\"https:\/\/www.co2meter.com\/pages\/downloads\" title=\"Gaslab data logging software\"\u003eGaslab data logging software\u003c\/a\u003e. Sensor sold separately.\u003c\/p\u003e\n\u003c\/div\u003e","brand":"Senseair","offers":[{"title":"Default Title","offer_id":42845519249606,"sku":"004-0-0050","price":64.9,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/004-0-0050.jpg?v=1753284018"},{"product_id":"006-0-0007-senseair-sunrise-co2-sensor","title":"006-0-0007 Senseair Sunrise CO2 Sensor","description":"\u003cp\u003eThe \u003cspan style=\"color: #115e67;\" data-mce-style=\"color: #115e67;\"\u003e \u003cstrong\u003eSenseair Sunrise 1% CO2 Sensor\u003c\/strong\u003e\u003c\/span\u003e \u003cspan style=\"color: #115e67;\" data-mce-style=\"color: #115e67;\"\u003e\u003cstrong\u003e006-0-0007\u003c\/strong\u003e \u003c\/span\u003e\u003cstrong\u003e\u003c\/strong\u003e(\u003cem\u003eformerly known as SE-11) \u003c\/em\u003eis the first NDIR carbon dioxide sensor with LED technology that saves power while maintaining precise measurements.\u003c\/p\u003e\n\u003cp style=\"text-align: center;\"\u003e\u003cspan style=\"color: rgb(43, 0, 255);\"\u003e\u003cstrong\u003e\u003cspan style=\"color: rgb(255, 0, 0);\"\u003e**Note: the 006-0-0007 Senseair Sunrise 1% CO2 Sensor is Out of Stock, however, the\u003c\/span\u003e\u003ca href=\"https:\/\/www.co2meter.com\/products\/006-0-0007-senseair-sunrise-co2-sensor?variant=43961135956166\" title=\"Senseair Sunrise Development Kit\"\u003e CM-11 Senseair Sunrise CO2 Sensor and Development Kit\u003c\/a\u003e \u003cspan style=\"color: rgb(255, 0, 0);\"\u003eis Available**\u003c\/span\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eWide supply voltage range enables a variety of battery options\u003c\/li\u003e\n\u003cli\u003eRobust and resistant to vibrations and tough environment \u003c\/li\u003e\n\u003cli\u003eAdjustable ABC and measurement period by host\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eUltra-low power consumption\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eModels\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e006-0-0007: \u003c\/strong\u003eSenseair sunrise CO2 sensor, pinless design for integration into high-volume OEM products. \u003ca title=\"request for quote\" href=\"\/en-ca\/pages\/rfq\" data-mce-href=\"\/en-ca\/pages\/rfq\"\u003eContact us directly\u003c\/a\u003e for wholesale pricing on large quantities of this sensor - \u003cspan style=\"color: rgb(252, 13, 13);\"\u003e\u003cstrong\u003eOUT OF STOCK\u003c\/strong\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCM-11:\u003c\/strong\u003e Senseair Sunrise CO2 Sensor and Development Kit\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCM-200:\u003c\/strong\u003e Easy to use, simply plug the sensor into the PCB and plug it into your PC via USB. Use our free \u003ca href=\"\/en-ca\/pages\/downloads\" title=\"Gaslab software\" data-mce-href=\"\/en-ca\/pages\/downloads\"\u003eGasLab® software\u003c\/a\u003e to measure and graph carbon dioxide or use our \u003ca href=\"https:\/\/github.com\/co2meter-org\/ExampleCode\" title=\"Source code on Github\" rel=\"noopener\" data-mce-href=\"https:\/\/github.com\/co2meter-org\/ExampleCode\" target=\"_blank\"\u003elibrary of source code on Github\u003c\/a\u003e to build your own application or for OEM batch testing\/configuration. Order sensors on this page, then \u003ca href=\"https:\/\/www.co2meter.com\/products\/gas-sensor-development-kit\" title=\"Gas Sensor Development Kit\" data-mce-href=\"https:\/\/www.co2meter.com\/products\/gas-sensor-development-kit\"\u003eorder the devkit here\u003c\/a\u003e.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan style=\"color: #286adc;\" data-mce-style=\"color: #286adc;\"\u003e\u003cstrong\u003eWe recommend that all first time users purchase both this sensor and the CM-200 Development Kit for fastest and easiest results.\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cdiv class=\"specifications\"\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCO2 Measurement:\u003c\/strong\u003e non-dispersive infrared (NDIR)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMeasurement Method:\u003c\/strong\u003e Diffusion\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMeasurement Range:\u003c\/strong\u003e 400-5,000ppm. Extended range 10,000ppm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMeasurement Period: \u003c\/strong\u003edefault set - 16s, 8 samples\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAccuracy:\u003c\/strong\u003e ±30 ppm ± 3% of reading, extended range \u003cspan data-mce-fragment=\"1\"\u003e ±10% of reading 1,2\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMeasurement Period:\u003c\/strong\u003e Adjustable by host\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Supply:\u003c\/strong\u003e 3.05 - 5.5V 4\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePeak Current:\u003c\/strong\u003e \u0026lt;125mA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSteady Current during Sampling: \u003c\/strong\u003e99mA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperation Range:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e0-50\u003cspan\u003e°C, 0-85% RH\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eStorage Temperature: -40─70°C\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCommunication Options: \u003c\/strong\u003eUART, I2C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAverage Current: \u003c\/strong\u003e45µA3\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDimensions:\u003c\/strong\u003e 33.5 x 19.7 x 11.5\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e 5g\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLife expectancy:\u003c\/strong\u003e \u0026gt;15 years\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eWarranty\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e90 days - See\u003ca title=\"Terms and Conditions\" href=\"https:\/\/www.co2meter.com\/pages\/terms-conditions\" data-mce-href=\"https:\/\/www.co2meter.com\/pages\/terms-conditions\"\u003e CO2Meter Terms and Conditions.\u003c\/a\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"documents\"\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/rmtplusstoragesenseair.blob.core.windows.net\/docs\/Dev\/publicerat\/PSH11649.pdf\" data-mce-href=\"https:\/\/rmtplusstoragesenseair.blob.core.windows.net\/docs\/Dev\/publicerat\/PSH11649.pdf\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/CO2METER_PDF.png?1094\" alt=\"Senseair Sunrise Datasheet\" data-mce-src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/CO2METER_PDF.png?1094\"\u003e\u003cstrong\u003e\u003cspan style=\"color: red;\" data-mce-style=\"color: red;\"\u003e Data Sheet (pdf)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/rmtplusstoragesenseair.blob.core.windows.net\/docs\/Dev\/publicerat\/PSP11704.pdf\" data-mce-href=\"https:\/\/rmtplusstoragesenseair.blob.core.windows.net\/docs\/Dev\/publicerat\/PSP11704.pdf\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/CO2METER_PDF.png?1094\" alt=\"Senseair HVAC Manual\" data-mce-src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/CO2METER_PDF.png?1094\"\u003e\u003cstrong\u003e\u003cspan style=\"color: red;\" data-mce-style=\"color: red;\"\u003e Manual (pdf)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/rmtplusstoragesenseair.blob.core.windows.net\/docs\/Dev\/publicerat\/ANO4947.pdf\" data-mce-href=\"https:\/\/rmtplusstoragesenseair.blob.core.windows.net\/docs\/Dev\/publicerat\/ANO4947.pdf\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/CO2METER_PDF.png?1094\" alt=\"Custom Integration Manual\" data-mce-src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/CO2METER_PDF.png?1094\"\u003e\u003cstrong\u003e\u003cspan style=\"color: red;\" data-mce-style=\"color: red;\"\u003e Sensor Handling Manual (pdf)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/I2C-Sunrise-Modbus-Manual_Rev1.pdf?v=1653446719\" data-mce-href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/I2C-Sunrise-Modbus-Manual_Rev1.pdf?v=1653446719\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/CO2METER_PDF.png?1094\" alt=\"I2C Guide\" data-mce-src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/CO2METER_PDF.png?1094\"\u003e\u003cstrong\u003e\u003cspan style=\"color: red;\" data-mce-style=\"color: red;\"\u003eI2C Sunrise Guide(pdf)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/Modbus_Sunrise_Revised8.pdf?v=1653446778\" data-mce-href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/Modbus_Sunrise_Revised8.pdf?v=1653446778\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/CO2METER_PDF.png?1094\" alt=\"SE-11 Modbus Guide\" data-mce-src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/CO2METER_PDF.png?1094\"\u003e\u003cstrong\u003e\u003cspan style=\"color: red;\" data-mce-style=\"color: red;\"\u003e Modbus Guide (pdf)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/Manual-Development-Kit-SE-11.pdf?v=1653446817\" data-mce-href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/Manual-Development-Kit-SE-11.pdf?v=1653446817\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/CO2METER_PDF.png?1094\" alt=\"SE11 Development Kit Manual\" data-mce-src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/CO2METER_PDF.png?1094\"\u003e\u003cstrong\u003e\u003cspan style=\"color: red;\" data-mce-style=\"color: red;\"\u003eSE-12 Development Kit, Arduino, Raspberry Pi Code (pdf)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/SenseairISO.pdf?v=1613679881\" data-mce-href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/SenseairISO.pdf?v=1613679881\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/CO2METER_PDF.png?1093\" alt=\"Senseair ISO Certification\" data-mce-src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/CO2METER_PDF.png?1093\"\u003e\u003cstrong\u003e\u003cspan style=\"color: red;\" data-mce-style=\"color: red;\"\u003e Senseair ISO Certification (pdf)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"software\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv class=\"accessories\"\u003e\n\u003ch3\u003eAccessories\u003c\/h3\u003e\n\u003cp\u003e\u003ca title=\"CO2Meter Gas Sensor Development Kit\" href=\"https:\/\/www.co2meter.com\/products\/gas-sensor-development-kit\" data-mce-href=\"https:\/\/www.co2meter.com\/products\/gas-sensor-development-kit\"\u003e\u003cstrong\u003eGas Sensor Development Kit \u003c\/strong\u003e\u003c\/a\u003e- designed to provide customers with an easy drop-in solution. Includes our free \u003ca href=\"https:\/\/www.co2meter.com\/pages\/downloads\" title=\"Gaslab data logging software\" data-mce-href=\"https:\/\/www.co2meter.com\/pages\/downloads\"\u003eGaslab data logging software\u003c\/a\u003e. Sensor sold separately.\u003c\/p\u003e\n\u003c\/div\u003e","brand":"Senseair","offers":[{"title":"006-0-0007: Senseair Sunrise CO2 Sensor","offer_id":43961135923398,"sku":"006-0-0007","price":53.0,"currency_code":"USD","in_stock":true},{"title":"CM-11: Senseair Sunrise CO2 Sensor Development Kit","offer_id":43961135956166,"sku":"CM-11","price":329.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/006-0-0007_SE-11_CO2SensorlCO2Meter.jpg?v=1753284016"},{"product_id":"alphasense-o2-a2-oxygen-sensor","title":"O2-A3 Alphasense 25% 3 Year Oxygen Smart EC Sensor","description":"\u003cp\u003e\u003cspan\u003eThe \u003cspan style=\"color: rgb(17, 94, 103);\"\u003e\u003cstrong\u003eO2-A3 Alphasense Oxygen Sensor\u003c\/strong\u003e\u003c\/span\u003e (\u003cem\u003eformerly known as the AP-0004)\u003c\/em\u003e is a plug-in replacement sensor for hand-held gas detectors that use an O2-A3 sensor. Gaining precise oxygen measurement is critical for industries that require its use for safety, medical, air quality or specialized process.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan data-teams=\"true\"\u003e\u003ci\u003e\u003cstrong\u003eNote: Once an electrochemical (EC) sensor is purchased from CO2Meter.com and the sealed packaging is opened or the sensor module is installed, it is no longer eligible for return due to the limited operational lifespan that begins upon activation.\u003c\/strong\u003e\u003c\/i\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003eFeatures\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e0.1 to 20.9% oxygen sensor\u003c\/li\u003e\n\u003cli\u003eDoes not require calibration\u003c\/li\u003e\n\u003cli\u003eUp to 3 year lifespan\u003c\/li\u003e\n\u003cli\u003eSmall, compact and maintenance free\u003c\/li\u003e\n\u003cli\u003eMeasurement Range: 0.1-20.9% Oxygen\u003c\/li\u003e\n\u003cli\u003eOutput @\u003cspan style=\"font-size: 0.875rem;\"\u003e \u003c\/span\u003e\u003cspan style=\"font-size: 0.875rem;\"\u003e20.9% Oxygen: 60-85 uA\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003eOutput @ 0% O2: \u0026lt; 2.5 uA\u003c\/li\u003e\n\u003cli\u003eResponse Time: \u0026lt; 15 sec. t90 (s) from 20.9% to 0%\u003c\/li\u003e\n\u003cli\u003eLinearity: 0.6% O2 deviation @ 10%\u003c\/li\u003e\n\u003cli\u003eOutput drift: \u0026lt; 1% change @ 3 months\u003c\/li\u003e\n\u003cli\u003eOperating life: \u0026gt; 36 months until 85% original Output of 20.9%\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv class=\"specifications\"\u003e\n\u003ch3\u003eElectrical\/Mechanical\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eDimensions (sensor): 17.4mm x 20.3mm\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eWarranty\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e90 days. See CO2Meter Terms and Conditions\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"documents\"\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/ametekcdn.azureedge.net\/mediafiles\/project\/oneweb\/oneweb\/alphasense\/products\/datasheets\/alphasense_o2-a3_datasheet_jun24_en_1.pdf\" title=\"Datasheet for the O2-A3\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/CO2METER_PDF.png?1093\" alt=\"Datasheet\"\u003e\u003cstrong\u003e\u003cspan style=\"color: red;\"\u003e Data Sheet (pdf)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"accessories\"\u003e\n\u003cp\u003e\u003cstrong\u003e* Oxygen O2 Sensor Pin Sockets\u003c\/strong\u003e - Manufacturers do not recommend soldering to the pins. Pin sockets can be purchased from Andon distributors. \u003ca href=\"http:\/\/www.andonelect.com\/prod\/Gas-Sensor-Sockets_64.aspx\" title=\"pin socket for sensor\"\u003eClick here to search for your sensor's socket\u003c\/a\u003e. Select the brand PDF, find your sensor, then search for the Andon part number for your sensor's socket.\u003c\/p\u003e\n\u003c\/div\u003e","brand":"AlphaSense","offers":[{"title":"O2-A3 Alphasense Oxygen Sensor","offer_id":42864275718342,"sku":"O2-A3","price":90.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/AP-0004-forwebO2-A3.jpg?v=1753284015"},{"product_id":"coh-a2-alphasense-dual-gas-sensor","title":"COH-A2 Alphasense 5,000ppm Carbon Monoxide and Hydrogen Sulfide Gas Sensor","description":"\u003cp\u003eThe \u003cb\u003eCOH-A2 Alphasense Dual Gas Sensor \u003c\/b\u003e(\u003cem\u003eformerly known as the AP-0011)\u003c\/em\u003e detects both carbon monoxide and hydrogen sulfide in a single sensor. It is designed for OEM manufactures who need to measure both gases as well as a replacement sensor for several models of personal gas safety monitors.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFor Sensor Tube Caps, please look under the \"Accessories\" Tab\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch2\u003eFeatures\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eLow Cross-Sensitivity\u003c\/li\u003e\n\u003cli\u003eNo external power required\u003c\/li\u003e\n\u003cli\u003eProven and tested design\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThis 20mm diameter, 4-pin sensor is the industry standard size for portable gas detectors.\u003c\/p\u003e\n\u003cp\u003eThe 2sense does not compromise performance or long term stability over the standard two-sensor solution when measuring both H2S and CO.\u003c\/p\u003e\n\u003cdiv class=\"specifications\"\u003e\n\u003ch2\u003eSpecifications - Carbon Monoxide\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eSensitivity: nA\/ppm in 400ppm CO 50 to 100\u003c\/li\u003e\n\u003cli\u003eResponse time: tgo (s) from zero to 400ppm CO \u0026lt; 35\u003c\/li\u003e\n\u003cli\u003eZero current: ppm equivalent in zero air -3 to +3.5\u003c\/li\u003e\n\u003cli\u003eResolution: rms noise (ppm equivalent) \u0026lt; 0.5\u003c\/li\u003e\n\u003cli\u003eRange: ppm CO limit of performance warranty 1,000\u003c\/li\u003e\n\u003cli\u003eLinearity: ppm error at full scale, linear at zero and 400 ppm CO 10 to 40\u003c\/li\u003e\n\u003cli\u003eOvergas limit: maximum CO for stable response to gas pulse 5,000\u003c\/li\u003e\n\u003cli\u003eZero drift: ppm equivalent change\/year in lab air \u0026lt; 0.5\u003c\/li\u003e\n\u003cli\u003eSensitivity drift: % change\/year in lab air, monthly test \u0026lt; 4\u003c\/li\u003e\n\u003cli\u003eOperating life: months until 80% original signal (24 month warranted) 24\u003c\/li\u003e\n\u003cli\u003eSensitivity@ -20°C % (output@ -20°C\/output@ 20°C) @ 1 00ppm CO 30 to 50\u003c\/li\u003e\n\u003cli\u003eSensitivity@ 50°C % (output@ 50°C\/output@ 20°c)@ 100ppm CO 120 to 145\u003c\/li\u003e\n\u003cli\u003eZero@ -20°C ppm equivalent change from 20°c 0 to 5\u003c\/li\u003e\n\u003cli\u003eZero@ 50°C ppm equivalent change from 20°c 30 to 50 120 to 145 0 to -5\u003c\/li\u003e\n\u003cli\u003eTemperature range \u003cspan\u003e°C: \u003c\/span\u003e-30 to 50\u003c\/li\u003e\n\u003cli\u003ePressure range kPa: 80 to 120\u003c\/li\u003e\n\u003cli\u003eHumidity range %RH continuous 15 to 90\u003c\/li\u003e\n\u003cli\u003eStorage period months: @ 3 to 20°c (stored in sealed pot) 6\u003c\/li\u003e\n\u003cli\u003eLoad resistor: olms (recommended) 10 to 47\u003c\/li\u003e\n\u003cli\u003eWeight grams: \u0026lt; 6\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cstrong\u003eCROSS SENSITIVITY\u003c\/strong\u003e\u003cbr\u003e\n\u003cul\u003e\n\u003cli\u003eFilter Capacity: ppm-hours of Hydrogen Sulfide 1200\u003c\/li\u003e\n\u003cli\u003eH2S sensitivity % measured gas@ 20ppm H2S  \u0026lt; 12\u003c\/li\u003e\n\u003cli\u003eH2 sensitivity % measured gas@ 400ppm H2@ 20°C \u0026lt; 8\u003c\/li\u003e\n\u003cli\u003eNO2 sensitivity % measured gas@ 10ppm NO2 \u0026lt;3\u003c\/li\u003e\n\u003cli\u003eCl2 sensitivity % measured gas@ 10ppm Cl2 \u0026lt; 0.1\u003c\/li\u003e\n\u003cli\u003eNO sensitivity % measured gas@ 50ppm NO \u0026lt; 100\u003c\/li\u003e\n\u003cli\u003eSO2 sensitivity % measured gas@ 20ppm SO2 \u0026lt;2\u003c\/li\u003e\n\u003cli\u003eC2H4 sensitivity % measured gas@ 400ppm C2H4 \u0026lt; 60\u003c\/li\u003e\n\u003cli\u003eNH3 sensitivity % measured gas@ 20ppm NH3  \u0026lt; 6\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eSpecifications - Hydrogen Sulfide\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eSensitivity: nA\/ppm in 20ppm H2S 450 to 1000\u003c\/li\u003e\n\u003cli\u003eResponse time: tgo (s) from zero to 20ppm H2S@ 20°c \u0026lt; 30\u003c\/li\u003e\n\u003cli\u003eZero current: ppm equivalent in zero air ± 0.25\u003c\/li\u003e\n\u003cli\u003eResolution: rms noise (ppm equivalent) \u0026lt; 0.1\u003c\/li\u003e\n\u003cli\u003eRange: ppm H2S limit of performance warranty 100\u003c\/li\u003e\n\u003cli\u003eLinearity: ppm error at full scale, linear at zero and 20ppm H2S \u0026lt;± 5\u003c\/li\u003e\n\u003cli\u003eOvergas limit: maximum ppm H2S for stable response to gas pulse 200\u003c\/li\u003e\n\u003cli\u003eLifetime Zero drift: ppm equivalent change\/year in lab air \u0026lt; 0.1\u003c\/li\u003e\n\u003cli\u003eLifetime Sensitivity drift: % change\/year in lab air, monthly test \u0026lt; 2\u003c\/li\u003e\n\u003cli\u003eOperating life: months until 80% original signal (24 month warranted) 24\u003c\/li\u003e\n\u003cli\u003eSensitivity@ -20°C % (output@ -20°C\/output@ 20°C)@ 20ppm H2S 75 to 90\u003c\/li\u003e\n\u003cli\u003eSensitivity@ 50°C % (output@ 50°C\/output@ 20°c) @ 20ppm H2s 100 to 112\u003c\/li\u003e\n\u003cli\u003eZero @ -20°C ppm equivalent change from 20°c ±0.05\u003c\/li\u003e\n\u003cli\u003eZero @ 50°C ppm equivalent change from 20°c \u0026lt;Oto 0.2\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cstrong\u003eCross Sensitivity\u003c\/strong\u003e\u003cbr\u003e\n\u003cul\u003e\n\u003cli\u003eNO2 sensitivity: % measured gas@ 10ppm NO2 \u0026lt; -30\u003c\/li\u003e\n\u003cli\u003eCl2 sensitivity % measured gas@ 10ppm Cl2 \u0026lt; -25\u003c\/li\u003e\n\u003cli\u003eNO sensitivity % measured gas@ 50ppm NO \u0026lt; 30\u003c\/li\u003e\n\u003cli\u003eS02 sensitivity % measured gas@ 20ppm SO2 \u0026lt; 30\u003c\/li\u003e\n\u003cli\u003eCO sensitivity % measured gas@ 400ppm CO \u0026lt; 1.5\u003c\/li\u003e\n\u003cli\u003eH2 sensitivity % measured gas@ 400ppm H2 \u0026lt; 0.3\u003c\/li\u003e\n\u003cli\u003eC2H4 sensitivity % measured gas@ 400ppm C2H4 \u0026lt; 0.2\u003c\/li\u003e\n\u003cli\u003eNH3 sensitivity % measured gas@ 20ppm NH3 \u0026lt;2 \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eWarranty\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e90 Days. See GasLab Terms and Conditions\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"documents\"\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/www.alphasense.com\/wp-content\/uploads\/2023\/01\/Alphasense_COH-A2_datasheet_AW.pdf\"\u003e\u003cimg alt=\"Datasheet\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/CO2METER_PDF.png?1093\"\u003e\u003cstrong\u003e\u003cspan style=\"color: red;\"\u003e Data Sheet (pdf)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"accessories\"\u003e\n\u003cp\u003eTube cap adapters easily convert 20mm standard gas sensors from diffusion to sampling sensors. Molded polymer grips sensor for easy fit and removal while maintaining a good seal.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca title=\"Tube cap adapter\" href=\"\/en-ca\/products\/sensor-tube-cap-adapter?variant=31044017619059\"\u003e\u003cstrong\u003eTC-1\u003c\/strong\u003e - 3 mm side mounted ports\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca title=\"tube cap adapter\" href=\"\/en-ca\/products\/sensor-tube-cap-adapter?variant=31044017651827\"\u003e\u003cstrong\u003eTC-2\u003c\/strong\u003e - 3 mm top mounted ports\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca title=\"tube cap adapter\" href=\"\/en-ca\/products\/sensor-tube-cap-adapter?variant=31044017684595\"\u003e\u003cstrong\u003eTC-3\u003c\/strong\u003e - 4.5 mm top mounted ports\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003ca title=\"micro-pump kit\" href=\"\/en-ca\/products\/gas-sensor-micro-pump\"\u003eMicro-Pump Kit\u003c\/a\u003e\u003c\/strong\u003e includes all the tools you need to utilize the tube-cap adapters as part of a sampling sensor system.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003ca title=\"nafion tubing\" href=\"\/en-ca\/products\/nafion-gas-sample-drying-tubing\"\u003eNafion tubing\u003c\/a\u003e \u003c\/strong\u003eis a highly selective, semi-permeable membrane to water vapor. If gases inside Nafion tubing are wetter than gases surrounding the tubing, drying will occur. If the surrounding gases are wetter, humidification will occur.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003ca title=\"gas sampling pump\" href=\"\/en-ca\/products\/gas-sampling-pump\"\u003eMicro gas sampling pumps\u003c\/a\u003e\u003c\/strong\u003e provide a constant flow of air across the sensor with a tube cap - perfect for bench-top testing of sensors for closed-loop sampling applications.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSensor Pin Sockets\u003c\/strong\u003e - Manufacturers do not recommend soldering to the pins. Pin sockets can be purchased from Andon distributors. \u003ca href=\"http:\/\/www.andonelect.com\/prod\/Gas-Sensor-Sockets_64.aspx\" title=\"pin socket for sensor\"\u003eClick here to search for your sensor's socket\u003c\/a\u003e. Select the brand PDF, find your sensor, then search for the Andon part number for your sensor's socket.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cli\u003eNO sensitivity % measured gas@ 50ppm NO \u0026lt; 30\u003c\/li\u003e\n\u003cli\u003eS02 sensitivity % measured gas@ 20ppm SO2 \u0026lt; 30\u003c\/li\u003e\n\u003cli\u003eCO sensitivity % measured gas@ 400ppm CO \u0026lt; 1.5\u003c\/li\u003e\n\u003cli\u003eH2 sensitivity % measured gas@ 400ppm H2 \u0026lt; 0.3\u003c\/li\u003e\n\u003cli\u003eC2H4 sensitivity % measured gas@ 400ppm C2H4 \u0026lt; 0.2\u003c\/li\u003e\n\u003cli\u003eNH3 sensitivity % measured gas@ 20ppm NH3 \u0026lt;2 \u003c\/li\u003e\n\u003ch3\u003eWarranty\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e90 Days. See CO2Meter Terms and Conditions\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"AlphaSense","offers":[{"title":"COH-A2 Alphasense Dual Gas Sensor","offer_id":42869992587462,"sku":"COH-A2","price":175.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/COH-A2DualGasSensorforShopify.jpg?v=1753284010"},{"product_id":"ch-a3-alphasense-pellistor-gas-sensor","title":"CH-A3 Alphasense 2.5% Pellistor Gas Sensor","description":"\u003cp\u003eThe \u003cstrong\u003eCH-A3 Alphasense Pellistor Gas Sensor \u003c\/strong\u003e﻿(\u003cem\u003e﻿formerly known as AP-0012)\u003c\/em\u003e detects low levels of flammable hydrocarbon gases including methane, ethane, propane, butane, acetylene, ethylene and isobutylene in ambient air.\u003c\/p\u003e\n\u003cp\u003eThis 20mm diameter sensor is the industry standard size for portable gas detectors.\u003cspan\u003e All pellistors are housed in certified flameproof chambers.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFor Sensor Tube Caps, please look under the \"Accessories\" Tab\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eFeatures\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e0 to 100% LEL methane\u003c\/li\u003e\n\u003cli\u003eHigh quality, low power\u003c\/li\u003e\n\u003cli\u003eExcellent poison resistance\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv class=\"specifications\"\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMeasuring Gas: methane\u003c\/li\u003e\n\u003cli\u003eSensing Method: Pellistor\u003c\/li\u003e\n\u003cli\u003eSensivity (mV \/ % methane): 15 to 22\u003c\/li\u003e\n\u003cli\u003eResponse time (t90 from air to 50% methane): \u0026lt; 15 sec.\u003c\/li\u003e\n\u003cli\u003eZero (mV in zero air) \u0026lt; ± 20mV\u003c\/li\u003e\n\u003cli\u003eRange (% LEL methane): 0 to 100\u003c\/li\u003e\n\u003cli\u003eLinearity (% methane when 5% non-linear): 6%\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eWarranty\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e90 Days. See CO2Meter Terms and Conditions.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"documents\"\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/www.alphasense.com\/wp-content\/uploads\/2022\/09\/Alphasense_CHA3_datasheet.pdf\"\u003e\u003cimg alt=\"AlphaSense H2S Sensor Datasheet\" src=\"\/images\/admin\/icons\/mimes\/pdf.gif\"\u003e\u003c\/a\u003e\u003ca title=\"DATA SHEET FOR THE CH-A3\" href=\"https:\/\/www.alphasense.com\/wp-content\/uploads\/2022\/09\/Alphasense_CHA3_datasheet.pdf\" target=\"_blank\"\u003e\u003cstrong\u003e\u003cspan style=\"color: red;\"\u003e Data Sheet (pdf)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"accessories\"\u003e\n\u003cspan\u003eTube cap adapters easily convert 20mm standard gas sensors from diffusion to sampling sensors. Molded polymer grips sensor for easy fit and removal while maintaining a good seal.\u003c\/span\u003e\u003cbr\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"\/en-ca\/products\/sensor-tube-cap-adapter?variant=31044017619059\" title=\"Tube cap adapter\"\u003e\u003cstrong\u003eTC-1\u003c\/strong\u003e - 3 mm side mounted ports\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/en-ca\/products\/sensor-tube-cap-adapter?variant=31044017651827\" title=\"tube cap adapter\"\u003e\u003cstrong\u003eTC-2\u003c\/strong\u003e - 3 mm top mounted ports\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/en-ca\/products\/sensor-tube-cap-adapter?variant=31044017684595\" title=\"tube cap adapter\"\u003e\u003cstrong\u003eTC-3\u003c\/strong\u003e - 4.5 mm top mounted ports\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003ca href=\"\/en-ca\/products\/gas-sensor-micro-pump\" title=\"micro-pump kit\"\u003eMicro-Pump Kit\u003c\/a\u003e\u003c\/strong\u003e includes all the tools you need to urilize the tube-cap adapters as part of a sampling sensor system.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003ca href=\"\/en-ca\/products\/nafion-gas-sample-drying-tubing\" title=\"nafion tubing\"\u003eNafion tubing\u003c\/a\u003e i\u003c\/strong\u003es a highly selective, semi-permeable membrane to water vapor. If gases inside Nafion tubing are wetter than gases surrounding the tubing, drying will occur. If the surrounding gases are wetter, humidification will occur.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003ca href=\"\/en-ca\/products\/gas-sampling-pump\" title=\"gas sampling pump\"\u003eMicro gas sampling pumps\u003c\/a\u003e\u003c\/strong\u003e provide a constant flow of air across the sensor with a tube cap - perfect for bench-top testing of sensors for closed-loop sampling applications.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSensor Pin Sockets\u003c\/strong\u003e - Manufacturers do not recommend soldering to the pins. Pin sockets can be purchased from Andon distributors. \u003ca title=\"pin socket for sensor\" href=\"http:\/\/www.andonelect.com\/prod\/Gas-Sensor-Sockets_64.aspx\"\u003eClick here to see the PDF of all AlphaSense sensors pin sockets\u003c\/a\u003e, find your sensor brand, then find and search for the Andon part number for your sensor.\u003c\/p\u003e\n\u003c\/div\u003e","brand":"AlphaSense","offers":[{"title":"CH-A3 Alphasense 2.5% Pellistor Gas Sensor","offer_id":42870373548230,"sku":"CH-A3","price":158.0,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/CH-A3-Combustible-Gas-Pellistor-Sensor800X800.jpg?v=1753284002"},{"product_id":"h2s-a1-alphasense-hydrogen-sulfide-sensor","title":"H2S-A1 Alphasense 1% Hydrogen Sulfide Sensor","description":"\u003cp\u003eThe \u003cstrong\u003eH2S-A1 AlphaSense Hydrogen Sulfide Sensor \u003c\/strong\u003e(\u003cem\u003eformerly known as the AP-0006)\u003c\/em\u003e is designed to detect low levels of hydrogen sulfide in ambient air using well-known fuel cell technology.\u003c\/p\u003e\n\u003cp\u003eThis 20mm diameter sensor is the industry standard size for portable gas detectors and also is compatible with the EC board.\u003c\/p\u003e\n\u003cp\u003e\u003cspan data-teams=\"true\"\u003e\u003ci\u003e\u003cstrong\u003eNote: Once an electrochemical (EC) sensor is purchased from CO2Meter.com and the sealed packaging is opened or the sensor module is installed, it is no longer eligible for return due to the limited operational lifespan that begins upon activation.\u003c\/strong\u003e\u003c\/i\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cmeta charset=\"utf-8\"\u003e\u003cstrong\u003eFor Sensor Tube Caps, please look under the \"Accessories\" Tab\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eWith very high sensitivity and low zero, accurate and stable readings are possible when measuring current concentration ranges at the parts per million level.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e0 to 100ppm H2S sensor\u003c\/li\u003e\n\u003cli\u003eDoes not require calibration\u003c\/li\u003e\n\u003cli\u003eUp to 2 year lifespan\u003c\/li\u003e\n\u003cli\u003eSmall, compact and maintenance free\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv class=\"specifications\"\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMeasuring Gas: Hydrogen Sulfide\u003c\/li\u003e\n\u003cli\u003eSensing Method: Fuel cell\u003c\/li\u003e\n\u003cli\u003eSensivity (nA\/ppm in 20ppm H2S): 550 to 875ppm\u003c\/li\u003e\n\u003cli\u003eResponse time (t90 from zero to 20ppm H2S): \u0026lt; 35 sec.\u003c\/li\u003e\n\u003cli\u003eZero Current (ppm equivalent in zero air) \u0026lt; ± 0.4ppm\u003c\/li\u003e\n\u003cli\u003eResolution (RMS noise ppm equivalent): \u0026lt; 0.05ppm\u003c\/li\u003e\n\u003cli\u003eRange (H2S limit of performance warranty): 100ppm\u003c\/li\u003e\n\u003cli\u003eLinearity (ppm error at full scale): 0 to -4ppm\u003c\/li\u003e\n\u003cli\u003eOvergas limit (maximum ppm for stable response): 500ppm\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eWarranty\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e90 Days. See CO2Meter Terms and Conditions\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eReplacement Sensor Cross Reference Chart\u003c\/h3\u003e\n\u003ctable width=\"448\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd width=\"122\"\u003e\u003c\/td\u003e\n\u003ctd width=\"158\"\u003eModel\u003c\/td\u003e\n\u003ctd width=\"168\"\u003ePart Number\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSensor Type\u003c\/td\u003e\n\u003ctd\u003e4R H2S\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSemeatech\u003c\/td\u003e\n\u003ctd\u003e4H2S-100\u003c\/td\u003e\n\u003ctd\u003e052-0000-000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRAE\u003c\/td\u003e\n\u003ctd\u003e4H2S-100\u003c\/td\u003e\n\u003ctd\u003e032-0102-000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSolidsense\u003c\/td\u003e\n\u003ctd\u003e4H2S-100\u003c\/td\u003e\n\u003ctd\u003eCLE-0112-402\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCity\u003c\/td\u003e\n\u003ctd\u003e4H CiTiceL\u003c\/td\u003e\n\u003ctd\u003eAC200-800\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSensoric\u003c\/td\u003e\n\u003ctd\u003eH2S 3E 100S\u003c\/td\u003e\n\u003ctd\u003e0145-134-30049\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAlphasense\u003c\/td\u003e\n\u003ctd\u003e(0-500)\u003c\/td\u003e\n\u003ctd\u003eH2S-A1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMembrapor\u003c\/td\u003e\n\u003ctd\u003en\/a\u003c\/td\u003e\n\u003ctd\u003eH2S\/M-100\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDDS\u003c\/td\u003e\n\u003ctd\u003e(0-100)\u003c\/td\u003e\n\u003ctd\u003eGS+4H2S\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"documents\"\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/www.alphasense.com\/wp-content\/uploads\/2022\/09\/Alphasense_H2S-A1_datasheet.pdf\"\u003e\u003cimg alt=\"AlphaSense H2S Sensor Datasheet\"\u003e\u003cstrong\u003e\u003cspan style=\"color: red;\"\u003e Data Sheet (pdf)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"accessories\"\u003e\n\u003cspan\u003eTube cap adapters easily convert 20mm standard gas sensors from diffusion to sampling sensors. Molded polymer grips sensor for easy fit and removal while maintaining a good seal.\u003c\/span\u003e\u003cbr\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"\/en-ca\/products\/sensor-tube-cap-adapter?variant=31044017619059\" title=\"Tube cap adapter\"\u003e\u003cstrong\u003eTC-1\u003c\/strong\u003e - 3 mm side mounted ports\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/en-ca\/products\/sensor-tube-cap-adapter?variant=31044017651827\" title=\"tube cap adapter\"\u003e\u003cstrong\u003eTC-2\u003c\/strong\u003e - 3 mm top mounted ports\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/en-ca\/products\/sensor-tube-cap-adapter?variant=31044017684595\" title=\"tube cap adapter\"\u003e\u003cstrong\u003eTC-3\u003c\/strong\u003e - 4.5 mm top mounted ports\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003ca href=\"\/en-ca\/products\/gas-sensor-micro-pump\" title=\"micro-pump kit\"\u003eMicro-Pump Kit\u003c\/a\u003e\u003c\/strong\u003e includes all the tools you need to utilize the tube-cap adapters as part of a sampling sensor system.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003ca href=\"\/en-ca\/products\/nafion-gas-sample-drying-tubing\" title=\"nafion tubing\"\u003eNafion tubing\u003c\/a\u003e i\u003c\/strong\u003es a highly selective, semi-permeable membrane to water vapor. If gases inside Nafion tubing are wetter than gases surrounding the tubing, drying will occur. If the surrounding gases are wetter, humidification will occur.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003ca href=\"\/en-ca\/products\/gas-sampling-pump\" title=\"gas sampling pump\"\u003eMicro gas sampling pumps\u003c\/a\u003e\u003c\/strong\u003e provide a constant flow of air across the sensor with a tube cap - perfect for bench-top testing of sensors for closed-loop sampling applications.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSensor Pin Sockets\u003c\/strong\u003e - Manufacturers do not recommend soldering to the pins. Pin sockets can be purchased from Andon distributors. \u003ca title=\"pin socket for sensor\" href=\"http:\/\/www.andonelect.com\/prod\/Gas-Sensor-Sockets_64.aspx\"\u003eClick here to search for your sensor's socket\u003c\/a\u003e. Select the brand PDF, find your sensor, then search for the Andon part number for your sensor's socket.\u003c\/p\u003e\n\u003c\/div\u003e","brand":"AlphaSense","offers":[{"title":"H2S-A1 Alphasense Hydrogen Sulfide Sensor","offer_id":42870462087366,"sku":"H2S-A1","price":156.0,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/H2S-A1Shopify800x800.jpg?v=1753283998"},{"product_id":"sbh-2-cubic-2-propane-sensor","title":"SBH-2A Cubic 2% Propane Sensor","description":"\u003cp\u003eThe \u003cstrong\u003eSBH-2A Cubic NDIR 2% Propane Gas Sensor\u003c\/strong\u003e detects 0-2% levels of C3H8 propane gas in ambient environments.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMeasures 0 to 2% Propane by volume\u003c\/li\u003e\n\u003cli\u003eFull range linearized and digital signal output\u003c\/li\u003e\n\u003cli\u003eShock-resistant, long-life NDIR sensor\u003c\/li\u003e\n\u003cli\u003eReference channel for self-compensation\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eBuild-in temperature and humility compensation to ensure accuracy\u003c\/li\u003e\n\u003cli\u003eHigh humidity alert mechanism, reliable fail-safe operation\u003c\/li\u003e\n\u003cli\u003eAuto zero-calibration mechanism available\u003c\/li\u003e\n\u003cli\u003eFast response, no moving parts, high stability, anti-corrosion\u003c\/li\u003e\n\u003cli\u003eMeet the explosion-proof level Ex ia IIC T4 Ga, certification No GYB19.1789\u003c\/li\u003e\n\u003cli\u003eLife expectancy \u0026gt; 10 Years\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMine, metallurgy, oil \u0026amp; gas\u003c\/li\u003e\n\u003cli\u003eGas leak alarms\u003c\/li\u003e\n\u003cli\u003eLPG leak monitoring\u003c\/li\u003e\n\u003cli\u003eLiquefied gas station\u003c\/li\u003e\n\u003cli\u003eFuel gas transport\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eModels\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eSBH-2A Cubic 2% Propane Sensor\u003c\/strong\u003e 0-2% Vol Propane gas sensor, with 'A' housing\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e﻿SBH-2B Cubic 2% Propane Sensor - \u003c\/strong\u003e﻿0-2% Vol Propane gas sensor, with complimentary design and 'B' housing.\u003cbr\u003e\u003c\/p\u003e\n\u003cdiv class=\"specifications\"\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMeasuring Gas: Propane\u003c\/li\u003e\n\u003cli\u003eSensing Method: NDIR\u003c\/li\u003e\n\u003cli\u003eMeasurement Range: 0-2% Vol\u003c\/li\u003e\n\u003cli\u003eMeasurement Resolution: 0.01%\u003c\/li\u003e\n\u003cli\u003eAccuracy: \u0026lt; 0.1% Vol\u003c\/li\u003e\n\u003cli\u003eRate of Measurement: 1 sec\u003c\/li\u003e\n\u003cli\u003eWarm-up time: \u0026lt; 10 sec\u003c\/li\u003e\n\u003cli\u003eResponse Time T90: \u0026lt; 25 sec\u003c\/li\u003e\n\u003cli\u003eZero Repeatability: ± 1% at FS\u003c\/li\u003e\n\u003cli\u003eZero Drift: 2% FS\/month\u003c\/li\u003e\n\u003cli\u003eWorking Temperature: -40° ~ 70°C (-40°F-158°F)\u003c\/li\u003e\n\u003cli\u003eWorking Humidity: 095% RH (Non-condensing\u003c\/li\u003e\n\u003cli\u003eStorage Temperature: -40° ~ 85°C (-40°F-185°F)\u003c\/li\u003e\n\u003cli\u003eWorking Voltage: 3.3-6VDC\u003c\/li\u003e\n\u003cli\u003eWorking Current: 55-60mA\u003c\/li\u003e\n\u003cli\u003ePeak Current: 360-400mA @ 5VDC\u003c\/li\u003e\n\u003cli\u003eWorking Pressure: 30~130kPa\u003c\/li\u003e\n\u003cli\u003eUART Settings: 9,600, 8,N,1\u003c\/li\u003e\n\u003cli\u003eUART Output: 2.5-3.3V UART-TTL\u003c\/li\u003e\n\u003cli\u003eAnalog Output: 0.4V-2VDC\u003c\/li\u003e\n\u003cli\u003eDimensions: 20x19mm (0.79x0.75in)\u003c\/li\u003e\n\u003cli\u003eBody Material: Stainless Steel\u003c\/li\u003e\n\u003cli\u003eWeight: 18g\u003c\/li\u003e\n\u003cli\u003eOutput footprint: 5 pins\u003c\/li\u003e\n\u003cli\u003eSensor Life Span: \u0026gt; 10 years\u003c\/li\u003e\n\u003cli\u003eEx-proof Level: Ex ia IIC T4 Ga GYB19.1789\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eWarranty\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e90 Days. See CO2Meter Terms and Conditions.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"documents\"\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/innovaertech.com\/wp-content\/uploads\/2022\/05\/SBH-2.pdf\"\u003e\u003cimg alt=\"Sensor Manual\" src=\"\/images\/admin\/icons\/mimes\/pdf.gif\"\u003e\u003cstrong\u003e\u003cspan style=\"color: red;\"\u003e Manual (pdf)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"software\"\u003e\u003c\/div\u003e\n\u003cdiv class=\"accessories\"\u003e\n\u003cp\u003e\u003cstrong\u003eSensor Pin Sockets\u003c\/strong\u003e - Manufacturers do not recommend soldering to the pins. Pin sockets can be purchased from Andon Electric. \u003ca title=\"pin socket for sensor\" href=\"http:\/\/andonelect.com\/secure\/ImagesClientUpload\/crossreferences\/gas_sensor\/wuhan_cubic_optoelectronics.pdf\"\u003eClick here to see the PDF of all Cubic sensors pin sockets available\u003c\/a\u003e.\u003c\/p\u003e\n\u003c\/div\u003e","brand":"Wuhan Cubic","offers":[{"title":"SBH-2A Cubic 2% Propane Sensor","offer_id":42870634348742,"sku":"SBH-2A","price":248.0,"currency_code":"USD","in_stock":true},{"title":"SBH-2B Cubic 2% Propane Sensor - Complimentary Design\/Housing","offer_id":42981928075462,"sku":"SBH-2B","price":250.0,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/SBH-2A-Propane-Sensor-Shopify_800x800_68fe2237-4ace-4cbf-8ac2-9567c50c1c52.jpg?v=1753283994"},{"product_id":"sbrh-5-cubic-5-methyl-bromide-sensor-success","title":"SBrH-5A Cubic 5% Methyl Bromide Sensor","description":"\u003cp\u003eThe \u003cstrong\u003eSBrH-5A Cubic 5%\u003c\/strong\u003e\u003cstrong\u003e NDIR Methyl Bromide Gas Sensor\u003c\/strong\u003e by Cubic detects 0-5% levels of  CH3Br methyl bromide gas in ambient environments.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMeasures 0 to 5% Methyl Bromide by Volume\u003c\/li\u003e\n\u003cli\u003eLong-life NDIR sensor\u003c\/li\u003e\n\u003cli\u003eBuilt-in temperature and humidity compensation\u003c\/li\u003e\n\u003cli\u003eAuto-Baseline calibration can be enabled\u003c\/li\u003e\n\u003cli\u003ePrecise measurement and stable performance\u003c\/li\u003e\n\u003cli\u003eATEX rated for combustible environments\u003c\/li\u003e\n\u003cli\u003eSerial UART and analog voltage outputs\u003c\/li\u003e\n\u003cli\u003eLife expectancy \u0026gt; 10 Years\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eIndustrial Safety\u003c\/li\u003e\n\u003cli\u003eFumigation\u003c\/li\u003e\n\u003cli\u003eChemical\u003c\/li\u003e\n\u003cli\u003eOil \u0026amp; gas\u003c\/li\u003e\n\u003cli\u003eGas drainage monitoring\u003c\/li\u003e\n\u003cli\u003eLiquefied gas station or transport\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eModels\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eSBrH-5A Methyl Bromide Sensor\u003c\/strong\u003e 0-5% methyl bromide gas sensor, with 'A' housing.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSBrH-5B Methyl Bromide Sensor \u003c\/strong\u003e0-5%, complimentary design with 'B' housing.\u003c\/p\u003e\n\u003cdiv class=\"specifications\"\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMeasuring Gas: Bromomethane\u003c\/li\u003e\n\u003cli\u003eSensing Method: NDIR\u003c\/li\u003e\n\u003cli\u003eMeasurement Range: 0-5% Vol\u003c\/li\u003e\n\u003cli\u003eMeasurement Resolution: 0.01%\u003c\/li\u003e\n\u003cli\u003eAccuracy: ± 0.06% @ 0-1%, ± 6% @ 1% to FS\u003c\/li\u003e\n\u003cli\u003eRate of Measurement: 1 sec\u003c\/li\u003e\n\u003cli\u003eWarm-up time: \u0026lt; 30 sec\u003c\/li\u003e\n\u003cli\u003eResponse Time T90: \u0026lt; 25 sec\u003c\/li\u003e\n\u003cli\u003eZero Repeatability: ± 2% at FS\u003c\/li\u003e\n\u003cli\u003eZero Drift: 2% FS\/month\u003c\/li\u003e\n\u003cli\u003eWorking Temperature: -40° ~ 70°C (-40°F-158°F)\u003c\/li\u003e\n\u003cli\u003eWorking Humidity: 095% RH (Non-condensing\u003c\/li\u003e\n\u003cli\u003eStorage Temperature: -40° ~ 85°C (-40°F-185°F)\u003c\/li\u003e\n\u003cli\u003eWorking Voltage: 3.3-6VDC\u003c\/li\u003e\n\u003cli\u003eWorking Current: 55-60mA\u003c\/li\u003e\n\u003cli\u003ePeak Current: 360-400mA @ 5VDC\u003c\/li\u003e\n\u003cli\u003eWorking Pressure: 30~130kPa\u003c\/li\u003e\n\u003cli\u003eUART Settings: 9,600, 8,N,1\u003c\/li\u003e\n\u003cli\u003eUART Output: 2.5-3.3V UART-TTL\u003c\/li\u003e\n\u003cli\u003eAnalog Output: 0.4V-2VDC\u003c\/li\u003e\n\u003cli\u003eDimensions: 20x19mm (0.79x0.75in)\u003c\/li\u003e\n\u003cli\u003eBody Material: Stainless Steel\u003c\/li\u003e\n\u003cli\u003eWeight: 18g\u003c\/li\u003e\n\u003cli\u003eOutput footprint: 5 pins\u003c\/li\u003e\n\u003cli\u003eSensor Life Span: \u0026gt; 10 years\u003c\/li\u003e\n\u003cli\u003eEx-proof Level: Ex ia IIC T4 Ga GYB19.1789\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eWarranty\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e90 Days. See CO2Meter Terms and Conditions\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"documents\"\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/innovaertech.com\/wp-content\/uploads\/2022\/05\/SBrH-5.pdf\"\u003e\u003cimg src=\"\/images\/admin\/icons\/mimes\/pdf.gif\" alt=\"Sensor Manual\"\u003e\u003c\/a\u003e\u003cstrong\u003e\u003cspan style=\"color: red;\"\u003e\u003ca href=\"https:\/\/innovaertech.com\/wp-content\/uploads\/2022\/05\/SBrH-5.pdf\"\u003e \u003c\/a\u003e\u003ca title=\"SBrH-5 Cubic 5% Methyl Bromide Sensor\" href=\"https:\/\/innovaertech.com\/wp-content\/uploads\/2022\/05\/SBrH-5.pdf\" target=\"_blank\"\u003eManual (pdf)\u003c\/a\u003e\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"software\"\u003e\u003c\/div\u003e\n\u003cdiv class=\"accessories\"\u003e\n\u003cp\u003e\u003cstrong\u003eSensor Pin Sockets\u003c\/strong\u003e - Manufacturers do not recommend soldering to the pins. Pin sockets can be purchased from Andon Electric. \u003ca title=\"pin socket for sensor\" href=\"http:\/\/andonelect.com\/secure\/ImagesClientUpload\/crossreferences\/gas_sensor\/wuhan_cubic_optoelectronics.pdf\"\u003eClick here to see the PDF of all Cubic sensors pin sockets available\u003c\/a\u003e.\u003c\/p\u003e\n\u003c\/div\u003e","brand":"Wuhan Cubic","offers":[{"title":"SBrH-5A 5% Methyl Bromide Sensor","offer_id":42870638608582,"sku":"SBrH-5A","price":275.0,"currency_code":"USD","in_stock":false},{"title":"SBrH-5B 5% Methyl Bromide Sensor with Complimentary Design\/Housing","offer_id":42981934661830,"sku":"SBrH-5B","price":275.0,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/SBrH-5A-Methyl-Bromide-Sensor-_l_CO2Meter.jpg?v=1753283992"},{"product_id":"o2-a1-alphasense-25-industrial-safe-oxygen-sensor","title":"O2-A1 Alphasense 25% 1 Year Oxygen Smart EC Sensor","description":"\u003cp\u003e\u003cspan\u003eThe \u003cstrong\u003eO2-A1 Alphasense Oxygen sensor\u003c\/strong\u003e is designed to provide engineers, scientists and students an accurate and reliable way to measure up to 25% oxygen levels by volume. \u003c\/span\u003eThis sensor is a low cost, industrial safe, oxygen module designed to last one year.\u003c\/p\u003e\n\u003cp\u003e\u003cspan data-teams=\"true\"\u003e\u003ci\u003e\u003cstrong\u003eNote: Once an electrochemical (EC) sensor is purchased from CO2Meter.com and the sealed packaging is opened or the sensor module is installed, it is no longer eligible for return due to the limited operational lifespan that begins upon activation.\u003c\/strong\u003e\u003c\/i\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eElectrochemical Sensor measures up to 25% Oxygen\u003c\/li\u003e\n\u003cli\u003eSmart EC board adds Barometric Pressure, Temperature and % Relative Humidity Sensors\u003c\/li\u003e\n\u003cli\u003eSmart EC Board Adds Serial UART Output\u003c\/li\u003e\n\u003cli\u003eSmart EC board Adds RS485 with Optional \u003ca href=\"\/en-ca\/products\/rs485-cable-ec-mx-sensor-development-kits\" title=\"RS485 cable\"\u003eRS485 Cable\u003c\/a\u003e\n\u003c\/li\u003e\n\u003cli\u003eEasy Integration; Compact \u0026amp; Low Power\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eModels\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eO2-A1 \u003c\/span\u003eSensor Only\u003c\/strong\u003e – Sensor only.  \u003cspan\u003eUnlike partial pressure oxygen sensors, they have good pressure and temperature dependence, making them the best choice in safety applications.\u003c\/span\u003e\u003cstrong\u003e\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv class=\"specifications\"\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMeasurement Range: 0-20.9% oxygen\u003c\/li\u003e\n\u003cli\u003eOutput: 80-120 uA @ 20.9% O2\u003c\/li\u003e\n\u003cli\u003eResponse Time: \u0026lt; 15 sec. t90 (s) from 20.9% to 0% O2\u003c\/li\u003e\n\u003cli\u003eLinearity: 0.6% O2 deviation @ 10% O2\u003c\/li\u003e\n\u003cli\u003eOutput drift: \u0026lt; 1% change @ 3 months\u003c\/li\u003e\n\u003cli\u003eOperating life: \u0026gt; 24 months until 85% original Output of 20.9% O2\u003c\/li\u003e\n\u003cli\u003eAnalog Output: 0-3VDC\u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eElectrical\/Mechanical\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eDimensions (sensor): 17.4mm x 20.3mm\u003c\/li\u003e\n\u003cli\u003eDimensions (sensor + PCB): 40mm X 25mm x 29mm (LxWxH)\u003c\/li\u003e\n\u003cli\u003ePower Input: 3.3-5.5 VDC\u003c\/li\u003e\n\u003cli\u003eCurrent Consumption: 10ma peak, \u0026lt; 3mW average\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eWarranty\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e90 days - See CO2Meter Terms and Conditions.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"documents\"\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/ametekcdn.azureedge.net\/mediafiles\/project\/oneweb\/oneweb\/alphasense\/products\/datasheets\/alphasense_o2-a1_datasheet_en_1.pdf\"\u003e\u003cimg alt=\"Datasheet\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/CO2METER_PDF.png?1093\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/www.alphasense.com\/wp-content\/uploads\/2022\/09\/Alphasense_O2-A1_datasheet.pdf\" title=\"Datasheet for the O2-A2\"\u003e\u003cstrong\u003e\u003cspan style=\"color: red;\"\u003e Data Sheet (pdf)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"http:\/\/www.alphasense.com\/wp-content\/uploads\/2013\/07\/AAN_006-06.pdf\"\u003e\u003cimg alt=\"Documentation\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/CO2METER_PDF.png?1093\"\u003e\u003c\/a\u003e\u003ca href=\"http:\/\/www.alphasense.com\/wp-content\/uploads\/2013\/07\/AAN_006-06.pdf\" title=\"Alphasense 02-A2 oxygen sensor voltage outputs\" target=\"_blank\"\u003e\u003cstrong\u003e\u003cspan style=\"color: red;\"\u003e Voltage Output for OEM Applications (pdf)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003ch3\u003eVideos\u003c\/h3\u003e\n\u003ciframe width=\"560\" height=\"315\" src=\"https:\/\/www.youtube.com\/embed\/wYSLkLuS-xA\"\u003e\u003c\/iframe\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"software\"\u003e\n\u003ch3\u003eFree Easy-to-use GasLab® Software\u003c\/h3\u003e\n\u003cp\u003eThe Smart EC board uses GasLab® software for setup, calibration, data logging, and real-time data analysis. GasLab® makes it easy to export data into a .CSV file that can be imported into any industry-standard software or spreadsheet. GasLab® runs on Windows XP or higher, and free to use with our products.\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"\/en-ca\/pages\/downloads\"\u003e\u003cimg alt=\"Download Latest Software Here\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/download-drivers.gif?1253980035\"\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003ch3\u003eSystem Requirements\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eWindows XP SP2 or newer\u003c\/li\u003e\n\u003cli\u003eMicrosoft .Net 3.5 Runtime Libraries\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"accessories\"\u003e\n\u003ch3\u003eAccessories\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003ca href=\"\/en-ca\/products\/co2meter-sensor-tube-cap\"\u003eTube Cap Adapters\u003c\/a\u003e \u003c\/strong\u003eeasily convert 20mm standard gas sensors from diffusion to sampling sensors. \u003cspan\u003eMolded polymer. \u003c\/span\u003e\u003cstrong\u003eTube cap adapters are not pre-installed\u003c\/strong\u003e\u003cspan\u003e For accurate results you must \u003c\/span\u003e\u003ca href=\"http:\/\/co2meters.com\/Documentation\/Other\/Tube%20Cap%20Installation%20Procedure_rev_CO2Meter.pdf\"\u003emount the tube cap permanently\u003c\/a\u003e\u003cspan\u003e.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"\/en-ca\/products\/rs485-cable-ec-mx-sensor-development-kits\" title=\"RS485 Modbus cable\"\u003e\u003cstrong\u003eRS485 Cable\u003c\/strong\u003e\u003c\/a\u003e. Custom USB cable enables RS485 communication to GasLab Software for EC Sensor Board and Development Kit.\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"\/en-ca\/products\/gas-sensor-micro-pump\" title=\"micro-pump kit\"\u003e\u003cstrong\u003eMicro-Pump Kit\u003c\/strong\u003e\u003c\/a\u003e\u003cspan\u003e \u003c\/span\u003eincludes all the tools you need to utilize the tube-cap adapters as part of a sampling sensor system.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003ca href=\"\/en-ca\/products\/nafion-gas-sample-drying-tubing\" title=\"nafion tubing\"\u003eNafion Tubing\u003c\/a\u003e \u003c\/strong\u003eis a highly selective, semi-permeable membrane to water vapor. If gases inside Nafion tubing are wetter than gases surrounding the tubing, drying will occur. If the surrounding gases are wetter, humidification will occur.\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"\/en-ca\/products\/gas-sampling-pump\"\u003e\u003cstrong\u003eMicro Gas Sampling Pumps\u003c\/strong\u003e\u003c\/a\u003e\u003cspan\u003e \u003c\/span\u003eprovide a constant flow of air across the sensor with a tube cap - perfect for bench-top testing of sensors for closed-loop sampling applications.\u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e","brand":"AlphaSense","offers":[{"title":"O2-A1 Alphasense 25% 1 Year Oxygen Smart EC Sensor","offer_id":42913000259782,"sku":"O2-A1","price":77.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/O2-A1-Alphasense.jpg?v=1753283990"},{"product_id":"co-a1-alphasense-carbon-monoxide-smart-ec-sensor","title":"CO-A1 Alphasense 5,000ppm Carbon Monoxide 20mm Smart EC Sensor","description":"\u003cp\u003e\u003cspan\u003eThe \u003cstrong\u003eCO-A1\u003c\/strong\u003e \u003cstrong\u003eAlphaSense 5,000ppm Carbon Monoxide sensor\u003c\/strong\u003e is designed to detect highly dangerous toxic gas that poses a significant threat to those working in its presence. The circuit board's microprocessor provides zero and span calibration as well as barometric pressure, temperature and % relative humidity sensors. Features on-board memory to log data when used in a remote device.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThis sensor can also integrate within various applications such as fixed systems to monitor indoor air environments and industrial safety applications.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cspan data-teams=\"true\"\u003e\u003ci\u003e\u003cstrong\u003eNote: Once an electrochemical (EC) sensor is purchased from CO2Meter.com and the sealed packaging is opened or the sensor module is installed, it is no longer eligible for return due to the limited operational lifespan that begins upon activation.\u003c\/strong\u003e\u003c\/i\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eElectrochemical Sensor Measures up to 5,000ppm Carbon Monoxide\u003c\/li\u003e\n\u003cli\u003eSmart EC Board includes Barometric Pressure, Temperature and % Relative Humidity Sensors\u003c\/li\u003e\n\u003cli\u003eSmart EC Board adds Serial UART output\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan\u003eSmart EC Board adds RS485 output with optional \u003c\/span\u003e\u003ca href=\"\/en-ca\/products\/rs485-cable-ec-mx-sensor-development-kits\" title=\"RS485 cable\"\u003eRS485 cable\u003c\/a\u003e\n\u003c\/li\u003e\n\u003cli\u003eEasy Integration; Compact \u0026amp; Low Power\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003ch3\u003eModels\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eCO-A1 Alphasense 5,000ppm CO Sensor Only\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e–\u003cspan\u003e \u003c\/span\u003e\u003cspan\u003efor integration into high-volume OEM products, 20mm diameter, the industry standard size for portable gas detectors.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCM-31911 Development Kit\u003c\/strong\u003e – \u003cspan\u003eEasy to use, simply plug the EC Board into your PC via the included serial UART to USB cable. Use our free GasLab® software to measure and graph carbon dioxide, barometric pressure, temperature, and % relative humidity. Includes on-board memory for data logging.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCM-31910 Smart EC Board\u003c\/strong\u003e – \u003cspan\u003eSame functionality as the development kit without USB cable or software.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\n\u003cstrong\u003e\u003c\/strong\u003eSpecifications\u003c\/h3\u003e\n\u003cdiv class=\"specifications\"\u003e\n\u003cul\u003e\n\u003cli\u003eRange: 0-5,000ppm carbon monoxide\u003c\/li\u003e\n\u003cli\u003eSensitivity: 55 to 90 nA\/ppm in 400ppm CO\u003c\/li\u003e\n\u003cli\u003eResponse Time: \u0026lt; 25 sec. t90 (s) from zero to 400ppm\u003c\/li\u003e\n\u003cli\u003eZero current: -5 to +4ppm equivalent in zero air\u003c\/li\u003e\n\u003cli\u003eResolution: \u0026lt; 0.5 RMS noise (ppm equivalent)\u003c\/li\u003e\n\u003cli\u003eLinearity: +15 to +25ppm error rate at full scale from 0-1,000ppm\u003c\/li\u003e\n\u003cli\u003eZero drift: \u0026lt; 0.2ppm change per year\u003c\/li\u003e\n\u003cli\u003eSensitivity drift: \u0026lt; 8% change \/ year\u003c\/li\u003e\n\u003cli\u003eOperating life: \u0026gt; 24 months until 80% original signal\u003c\/li\u003e\n\u003cli\u003eDigital Output: Serial UART\u003c\/li\u003e\n\u003cli\u003eAnalog Output: Available\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eSmart EC Board Adds\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eTemperature, %RH, Barometric Pressure Sensors on Board\u003c\/li\u003e\n\u003cli\u003e64K memory for time-stamped data logging of all measurements  \u003c\/li\u003e\n\u003cli\u003e\n\u003cspan\u003eRS485 output with optional \u003c\/span\u003e\u003ca href=\"\/en-ca\/products\/rs485-cable-ec-mx-sensor-development-kits\" title=\"RS485 cable\"\u003eRS485 cable\u003c\/a\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eDevelopment Kit Adds\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eSmart EC Board\u003c\/li\u003e\n\u003cli\u003eSerial USB Cable\u003c\/li\u003e\n\u003cli\u003eFree GasLab Windows software for real-time measurements, data logging, graphing, sensor configuration.\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan\u003eRS485 output with optional \u003c\/span\u003e\u003ca href=\"\/en-ca\/products\/rs485-cable-ec-mx-sensor-development-kits\" title=\"RS485 cable\"\u003eRS485 cable\u003c\/a\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eElectrical\/Mechanical\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eDimensions (sensor): 16.5mm x 20.2mm\u003c\/li\u003e\n\u003cli\u003eDimensions (sensor + PCB): 40mm X 25mm x 29mm (LxWxH)\u003c\/li\u003e\n\u003cli\u003ePower Input: 3.3-5.5 VDC\u003c\/li\u003e\n\u003cli\u003eCurrent Consumption: 10ma peak, \u0026lt; 3mW average\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eWarranty\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e90 days - See \u003ca title=\"CO2Meter Terms and Conditions\" href=\"https:\/\/www.co2meter.com\/pages\/terms-conditions\"\u003e\u003cstrong\u003eCO2Meter Terms and Conditions.\u003c\/strong\u003e\u003c\/a\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"documents\"\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/DS_AP_0005_CM_31911_CM_31910_Revised8.pdf?v=1650731043\"\u003e\u003cimg alt=\"Datasheet\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/CO2METER_PDF.png?1093\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/DS_AP_0005_CM_31911_CM_31910_Revised8.pdf?v=1650731043\" title=\"Datasheet for the CO-A1\"\u003e\u003cstrong\u003e\u003cspan style=\"color: red;\"\u003e Data Sheet (pdf)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"software\"\u003e\n\u003ch3\u003eFree Easy-to-use GasLab® Software\u003c\/h3\u003e\n\u003cp\u003eThe Smart EC Board uses GasLab® software for setup, calibration, data logging, and real-time data analysis. GasLab® makes it easy to export data into a .CSV file that can be imported into any industry-standard software or spreadsheet. GasLab® runs on Windows XP or higher, and free to use with our products.\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"\/en-ca\/pages\/downloads\"\u003e\u003cimg alt=\"Download Latest Software Here\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/download-drivers.gif?1253980035\"\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003ch3\u003eSystem Requirements\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eWindows XP SP2 or newer\u003c\/li\u003e\n\u003cli\u003eMicrosoft .Net 3.5 Runtime Libraries\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"accessories\"\u003e\n\u003ch3\u003eAccessories\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e\u003ca href=\"\/en-ca\/products\/co2meter-sensor-tube-cap\"\u003eTube Cap Adapters\u003c\/a\u003e \u003c\/strong\u003eeasily convert 20mm standard gas sensors from diffusion to sampling sensors. \u003cspan\u003eMolded polymer. \u003c\/span\u003e\u003cstrong\u003eTube cap adapters are not pre-installed\u003c\/strong\u003e\u003cspan\u003e. For accurate results you must \u003c\/span\u003e\u003ca href=\"http:\/\/co2meters.com\/Documentation\/Other\/Tube%20Cap%20Installation%20Procedure_rev_CO2Meter.pdf\"\u003emount the tube cap permanently\u003c\/a\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"\/en-ca\/products\/rs485-cable-ec-mx-sensor-development-kits\" title=\"RS485 Modbus cable\"\u003e\u003cstrong\u003eRS485 Cable\u003c\/strong\u003e\u003c\/a\u003e. Custom USB cable enables RS485 communication to GasLab Software for EC Sensor Board and Development Kit.\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"\/en-ca\/products\/gas-sensor-micro-pump\" title=\"micro-pump kit\"\u003e\u003cstrong\u003eMicro-Pump Kit\u003c\/strong\u003e\u003c\/a\u003e\u003cspan\u003e \u003c\/span\u003eincludes all the tools you need to utilize the tube-cap adapters as part of a sampling sensor system.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003ca href=\"\/en-ca\/products\/nafion-gas-sample-drying-tubing\" title=\"nafion tubing\"\u003eNafion Tubing\u003c\/a\u003e \u003c\/strong\u003eis a highly selective, semi-permeable membrane to water vapor. If gases inside Nafion tubing are wetter than gases surrounding the tubing, drying will occur. If the surrounding gases are wetter, humidification will occur.\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"\/en-ca\/products\/gas-sampling-pump\"\u003e\u003cstrong\u003eMicro Gas Sampling Pumps\u003c\/strong\u003e\u003c\/a\u003e\u003cspan\u003e \u003c\/span\u003eprovide a constant flow of air across the sensor with a tube cap - perfect for bench-top testing of sensors for closed-loop sampling applications.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003ca href=\"https:\/\/www.co2meter.com\/collections\/accessories\/products\/probe-enclosure-development-kit\" title=\"View the Probe Enclosure for Development Kits\"\u003eProbe Enclosure for Development Kits\u003c\/a\u003e\u003c\/strong\u003e gives a strong and secure container to mount the sensor. Hydrophobic filters available for enclosure for outdoor use.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003ch3\u003eVideos\u003ciframe width=\"560\" height=\"315\" src=\"https:\/\/www.youtube.com\/embed\/wYSLkLuS-xA\" style=\"font-size: 0.875rem;\"\u003e\u003c\/iframe\u003e\n\u003c\/h3\u003e","brand":"AlphaSense","offers":[{"title":"CO-A1 Alphasense 5000ppm CO Smart EC Sensor","offer_id":43457424228550,"sku":"CO-A1","price":177.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/CO-A1.jpg?v=1753283989"}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/collections\/suppliers-280915.jpg?v=1702346739","url":"https:\/\/www.co2meter.com\/en-ca\/collections\/suppliers.oembed?page=2\u0026q=az-instruments","provider":"CO2 Meter","version":"1.0","type":"link"}