{"title":"Industrial Fixed Gas Detection Systems for Safety \u0026 Compliance","description":"\u003cp\u003eIndustrial fixed gas detection systems are designed to continuously monitor hazardous gas levels in real time protecting personnel, ensuring regulatory compliance, and preventing costly incidents.\u003c\/p\u003e\n\u003cp\u003eWhether you're monitoring \u003cstrong data-start=\"873\" data-end=\"948\"\u003eCO2, oxygen deficiency (O2), carbon monoxide (CO), or combustible gases\u003c\/strong\u003e, these systems provide \u003cstrong data-start=\"972\" data-end=\"991\"\u003e24\/7 protection\u003c\/strong\u003e with automated alarms, ventilation triggers and building system integration.\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eWhat is an Industrial Fixed Gas Detection System?\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp data-end=\"1293\" data-start=\"1138\"\u003eAn industrial fixed gas detection system is a permanently installed safety solution that continuously measures gas concentrations in critical environments.\u003c\/p\u003e\n\u003cp data-end=\"1336\" data-start=\"1295\"\u003eUnlike portable detectors, fixed systems:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli style=\"list-style-type: none;\"\u003e\n\u003cul data-end=\"1581\" data-start=\"1337\"\u003e\n\u003cli data-end=\"1405\" data-start=\"1337\" data-section-id=\"1raiswp\"\u003eMonitor \u003cstrong data-end=\"1370\" data-start=\"1347\"\u003especific risk zones\u003c\/strong\u003e (storage rooms, labs, fill plants)\u003c\/li\u003e\n\u003cli data-end=\"1459\" data-start=\"1406\" data-section-id=\"1nf1t3s\"\u003eTrigger \u003cstrong data-end=\"1459\" data-start=\"1416\"\u003eaudible\/visual alarms (horns \u0026amp; strobes)\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"1517\" data-start=\"1460\" data-section-id=\"3ydfeh\"\u003eIntegrate with \u003cstrong data-end=\"1517\" data-start=\"1477\"\u003eBMS, ventilation systems, and relays\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"1581\" data-start=\"1518\" data-section-id=\"uuxm6f\"\u003eProvide \u003cstrong data-end=\"1581\" data-start=\"1528\"\u003ereal-time alerts before dangerous exposure occurs\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","products":[{"product_id":"fixed-combustible-ammonia-nh3-detector","title":"Ammonia (NH3) Combustible Fixed Gas Detector (0-100ppm)","description":"\u003cp\u003e\u003cspan style=\"color: #115e67;\"\u003e\u003cspan style=\"color: rgb(0, 0, 0);\"\u003eThe\u003c\/span\u003e\u003cstrong\u003e Ammonia NH3 Combustible Fixed Gas Detector (PX2-1-2-E1125-A-01)\u003c\/strong\u003e\u003c\/span\u003e is designed for continuous monitoring of ammonia toxic gases between 0-100ppm and vapors in hazardous areas of zones 1 and 2.\u003c\/p\u003e\n\u003cp\u003eThis detector is an explosion-proof \u003cspan\u003efixed NH3 gas detector, which measures between 0 - 100ppm. The detector also is based with a 4-20 mA \/ RS485 Modbus output signal, alarm and fault relays (all SIL2 certified) for monitoring the ambient air to detect toxic gases.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThis solution is ideal for those industries using toxic gases such as oil\/gas, biogas plants, shipyards, petrochemical, agriculture, laboratory, medicine, and industrial manufacturing applications.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003eFeatures\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eModular industrial design, protection class IP66\u003c\/li\u003e\n\u003cli\u003eEx db: Ignition protection for zone 1 and 2\u003c\/li\u003e\n\u003cli\u003eEx nR: Ignition protection for zone 2\u003c\/li\u003e\n\u003cli\u003eFast and Precise NH3 Measurements 0-100ppm\u003c\/li\u003e\n\u003cli\u003eCompatible across a broad range of BMS\u003c\/li\u003e\n\u003cli\u003eDevice can be used independent of control systems\u003c\/li\u003e\n\u003cli\u003eIndividual configuration options available\u003c\/li\u003e\n\u003cli\u003eRobust against dust, humidity, and high\/low temperatures\u003c\/li\u003e\n\u003cli\u003eSuitable for multiple industries and applications\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eCertifications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eATEX and IECEx certificates MSR-Electronic GmbH for electrical Ex protection\u003c\/li\u003e\n\u003cli\u003eSIL2 safety functions 4–20 mA, RS-485 and relay\u003c\/li\u003e\n\u003cli\u003ePX2-1 for zone 1 (and also suitable for zone 2):\u003c\/li\u003e\n\u003cli\u003eType “Ex db” protection flame-proof enclosure\u003c\/li\u003e\n\u003cli\u003ePX2-2 for zone 2\u003c\/li\u003e\n\u003cli\u003eType “Ex nR” protection\u003c\/li\u003e\n\u003cli\u003eEnclosure: Additional FM and CSA certificates for Class I, Div. 1\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eModels\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePX2-1-2-E1110-C-01 - \u003c\/strong\u003eGaslab Fixed Combustible Carbon Monoxide Detector\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePX2-1-2-E1130-E-01 - \u003c\/strong\u003eGaslab Fixed Combustible Nitrogen Dioxide Detector\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePX2-1-2-E1194-A-01 - \u003c\/strong\u003eGaslab Fixed Combustible Hydrogen Detector\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePX2-1-2-E1195-A5-01 - \u003c\/strong\u003eGaslab Fixed Combustible Oxygen Detector\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePX2-1-2-E1197-B-01 - \u003c\/strong\u003eGaslab Fixed Combustible Hydrogen Sulfide Detector\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePX2-1-2-I464-C-01 - \u003c\/strong\u003eGaslab Fixed Combustible Carbon Dioxide Detector\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePX2-1-2-P3400-A-01 - \u003c\/strong\u003eGaslab Fixed Combustible Methane Detector\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePX2-1-2-P3480-A-01 - \u003c\/strong\u003eGaslab Fixed Combustible Propane Detector\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eWarranty\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e1-year warranty - see \u003ca title=\"View CO2Meter.com Terms and Conditions\" href=\"\/en-au\/pages\/terms-conditions\"\u003eCO2Meter Terms \u0026amp; Conditions\u003c\/a\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv class=\"specifications\"\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eGas Type:\u003c\/strong\u003e Ammonia\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRange ppm:\u003c\/strong\u003e 0-100ppm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAdmissible Range for Calibration Zero PPM:\u003c\/strong\u003e ± 10 % of measuring range\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAdmissible Range for Calibration Gain Test Gas:\u003c\/strong\u003e 30–120 % of test gas5\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTemperature Range: \u003c\/strong\u003e-30 to +50°C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStorage Temperature Range: \u003c\/strong\u003e0–20°C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHumidity Range: \u003c\/strong\u003e15-90 %RH\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePressure Range: \u003c\/strong\u003e80–120 kPa\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eReaction Time:\u003c\/strong\u003e ≤ 10 sec.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRun-in time2:\u003c\/strong\u003e 24 h\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFlow Rate:\u003c\/strong\u003e 500 ml\/min\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWarm-up Time:\u003c\/strong\u003e 300 Sec.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eResponse Time: \u003c\/strong\u003e≤ 200 Sec.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLife-time: \u003c\/strong\u003e\u0026gt;2 Years\u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"documents\"\u003e\n\u003ch3\u003eDocuments\u003c\/h3\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/DS-PX2-1-2-E1125-A-01_-_Gaslab_Fixed_Combustible_Ammonia_NH3_Detector.pdf?v=1716561399https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/DS-PX2-1-2-E1125-A-01_-_Gaslab_Fixed_Combustible_Ammonia_NH3_Detector.pdf?v=1716561399\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/CO2METER_PDF.png?1094\" alt=\"Gaslab Fixed Combustible NH3 Detector\"\u003e\u003c\/a\u003e\u003cspan\u003e\u003c\/span\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/DS-PX2-1-2-E1125-A-01_-_Gaslab_Fixed_Combustible_Ammonia_NH3_Detector.pdf?v=1725039980\" title=\"Gaslab Fixed Combustible NH3 Detector\"\u003e\u003cstrong\u003e\u003cspan style=\"color: #ff0000;\" color=\"#ff0000\"\u003eData Sheet (pdf)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca title=\"Manual Combustible Fixed Gas Detector - CO2Meter\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/MAN_GA_PX2_Ex_Tox_CO2Meter_1.pdf?v=1755545267\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/CO2METER_PDF.png?1094\" alt=\"Gaslab Fixed Combustible NH3 Detector\"\u003e\u003cstrong\u003e\u003cspan style=\"color: #ff0000;\" color=\"#ff0000\"\u003e Manual (pdf)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/MAN_GA_PX2_Ex_Tox_CO2Meter.pdf?v=1716564528\"\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e","brand":"CO2 Meter","offers":[{"title":"Default Title","offer_id":43731096469702,"sku":"PX2-1-2-E1125-A-01","price":2190.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/PX2-1-2-E1125-A-01_800x800_dcdf7f8f-d369-4c68-857d-d57e2a2cd29f.jpg?v=1753283954"},{"product_id":"fixed-ammonia-nh3-gas-detection-system","title":"Ammonia (NH3) Fixed Gas Detection System | Industrial Refrigeration \u0026 Facility Gas Monitoring System","description":"\u003cdiv style=\"text-align: left;\"\u003e\n\u003cp data-start=\"337\" data-end=\"607\"\u003eThe \u003cstrong data-start=\"341\" data-end=\"411\"\u003e\u003cspan style=\"color: rgb(17, 94, 103);\"\u003eAmmonia (NH₃) Fixed Gas Detection System with Remote Sensor (MSC2\u003c\/span\u003e)\u003c\/strong\u003e is an industrial-grade ammonia gas detector designed for continuous NH3 monitoring in high-risk environments including refrigeration systems, laboratories, agriculture and industrial facilities.\u003c\/p\u003e\n\u003cp data-start=\"609\" data-end=\"934\"\u003eAmmonia is a toxic and corrosive gas that can quickly reach dangerous concentrations, putting personnel, equipment, and compliance at risk. This fixed ammonia gas detection system provides real-time monitoring, early leak detection, and automated alarm response to help prevent exposure incidents and costly downtime.\u003c\/p\u003e\n\u003cp data-start=\"936\" data-end=\"1178\"\u003eBuilt on the flexible \u003cstrong data-start=\"958\" data-end=\"992\"\u003eMSC2 multi-gas safety platform\u003c\/strong\u003e, this system uses a remote ammonia gas sensor to detect leaks at the source in order to trigger alarms, activate ventilation systems and create rapid response.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003ch2\u003eFeatures\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli data-section-id=\"qf5sl8\" data-start=\"134\" data-end=\"206\"\u003e\n\u003cstrong data-start=\"139\" data-end=\"168\"\u003eContinuous NH3 Monitoring\u003c\/strong\u003e \u003c\/li\u003e\n\u003cli data-section-id=\"notiu7\" data-start=\"207\" data-end=\"272\"\u003e\n\u003cstrong data-start=\"212\" data-end=\"239\"\u003eRemote Sensor Detection\u003c\/strong\u003e \u003c\/li\u003e\n\u003cli data-section-id=\"u7ma8s\" data-start=\"273\" data-end=\"338\"\u003e\u003cstrong data-start=\"278\" data-end=\"305\"\u003eIndustrial-Grade Design\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli data-section-id=\"odmbzr\" data-start=\"339\" data-end=\"416\"\u003e\n\u003cstrong data-start=\"344\" data-end=\"376\"\u003eAudio\/Visual Alarms + Relays\u003c\/strong\u003e \u003c\/li\u003e\n\u003cli data-section-id=\"2ukb5t\" data-start=\"417\" data-end=\"481\"\u003e\n\u003cstrong data-start=\"422\" data-end=\"446\"\u003eMulti-Gas Expandable\u003c\/strong\u003e \u003c\/li\u003e\n\u003cli data-section-id=\"9b9z3w\" data-start=\"482\" data-end=\"538\"\u003e\n\u003cstrong data-start=\"487\" data-end=\"512\"\u003eBMS \u0026amp; PLC Integration\u003c\/strong\u003e \u003c\/li\u003e\n\u003cli data-section-id=\"s5looo\" data-start=\"539\" data-end=\"619\"\u003e\n\u003cstrong data-start=\"545\" data-end=\"570\"\u003eCustom Configurations\u003c\/strong\u003e \u003c\/li\u003e\n\u003cli data-section-id=\"dosia2\" data-start=\"620\" data-end=\"676\"\u003e\n\u003cstrong data-start=\"624\" data-end=\"650\"\u003eFlexible Power Options\u003c\/strong\u003e \u003c\/li\u003e\n\u003cli data-section-id=\"yrpvr4\" data-start=\"677\" data-end=\"740\"\u003e\n\u003cstrong data-start=\"682\" data-end=\"707\"\u003eIP65 Rugged Enclosure\u003c\/strong\u003e \u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 data-end=\"340\" data-start=\"316\" data-section-id=\"8bgedh\"\u003e\u003cspan role=\"text\"\u003e📦 What’s Included?\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli data-end=\"534\" data-start=\"342\" data-section-id=\"o7eaji\"\u003eMSC2 Fixed Gas Detection Controller (Main Display Unit)\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"711\" data-start=\"536\" data-section-id=\"1d98puf\"\u003e(1) Remote Ammonia (NH3) Gas Sensor\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"871\" data-start=\"713\" data-section-id=\"v4fgr9\"\u003e(2) Audible \u0026amp; Visual Horn\/Strobe Alarms\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"1040\" data-start=\"873\" data-section-id=\"1su4yby\"\u003ePre-Configured Alarm Relays (3 Outputs)\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"1175\" data-start=\"1042\" data-section-id=\"1p90s8v\"\u003ePower Supply Compatibility (100–240 VAC \/ 24 VDC)\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"1305\" data-start=\"1177\" data-section-id=\"1tk51f0\"\u003eWall-Mount Hardware \u0026amp; Installation Kit\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"1422\" data-start=\"1307\" data-section-id=\"jsmk4n\"\u003eUser Manual \u0026amp; Quick Start Guide\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv class=\"specifications\"\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMeasurement Range:\u003c\/strong\u003e 0-100ppm ppm NH3\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAdditional Ranges Available \u003cem\u003eon request\u003c\/em\u003e: \u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003e0-300ppm, 0-500ppm, 0-1,000ppm, 0-5,000ppm\u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eGas Type: \u003c\/b\u003eAmmonia (NH3)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHousing Type C\/E: \u003c\/strong\u003ePolycarbonate\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInstallation: \u003c\/strong\u003eWall Mounted\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eKnockouts for Cable Entry: \u003c\/strong\u003eStandard 6x M20\/25\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIngress Protection: \u003c\/strong\u003eIP65\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTemperature Range: \u003c\/strong\u003e-13°F to 140°F (-25°C to 60°C\u003cstrong\u003e)\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHumidity Range: \u003c\/strong\u003e15-90% RH non-condensing\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStorage Temperature: \u003c\/strong\u003e-4°F to 149°F (-20° to 65°C)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Supply:\u003c\/strong\u003e 100-240 VAC or 24VDC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Consumption: \u003c\/strong\u003e24VDC | Max. 60 mA (1.5 VA), w\/ sensor, w\/o WAO\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAlarm Relay (3): \u003c\/strong\u003e5 A Dry Contact Configurable\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTransistor Output (2):\u003c\/strong\u003e 24 V DC\/0.1 A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAnalog Input (2\/3): \u003c\/strong\u003e4-20mA, overload and short-circuit proof, input resistance 130 proportional, overload and short-circuit proof, load ≤ 500 4–20 mA = measuring range\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAnalog Output Signal (1):\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003e2.4–\u0026lt; 4 mA = tolerable under range\u003c\/li\u003e\n\u003cli\u003e20–21.2 mA = tolerable over range \u003c\/li\u003e\n\u003cli\u003e≥ 21,2 mA= error over range\u003c\/li\u003e\n\u003cli\u003e≤ 2,0 mA = fault\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eController Dimensions:\u003c\/strong\u003e 5.12 x 5.12 x 2.95 in. (130 x 130 x 75 mm)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eController Weight:\u003c\/strong\u003e 1.32 lbs. (0.6 kg)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"specifications\"\u003e\n\u003ch3\u003eWarranty\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e1 year - See \u003cstrong\u003e\u003ca href=\"https:\/\/www.co2meter.com\/pages\/terms-conditions\" title=\"CO2Meter Terms and Conditions\"\u003eCO2Meter Terms and Conditions\u003c\/a\u003e.\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"documents\"\u003e\n\u003cdiv class=\"data-sheets\"\u003e\n\u003cp style=\"text-align: left;\"\u003e\u003ca title=\"Gaslab Fixed Ammonia Gas Detector Datasheet\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/DS_-_MSC2-NH3-System-Fixed-Ammonia-System-Remote-2-Horn-Strobes.pdf\" target=\"_blank\"\u003e\u003cimg alt=\"Fixed Ammonia Industrial Gas Detector DataSheet\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/CO2METER_PDF.png?1093\"\u003e\u003c\/a\u003e\u003ca rel=\"noopener\" title=\"Fixed Ammonia Industrial Gas Detector Datasheet\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/DS_-_MSC2-NH3-System-Fixed-Ammonia-System-Remote-2-Horn-Strobes.pdf\" target=\"_blank\"\u003e\u003cstrong\u003e\u003cspan style=\"color: red;\"\u003eData Sheet - MSC2 Controller (pdf)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cimg alt=\"Gaslab Fixed Ammonia Gas Detector\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/CO2METER_PDF.png?1093\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/MAN_GA_MSC2_MSB2_CO2Meter-compressed_1.pdf?v=1755194606\"\u003e\u003cstrong\u003e\u003cspan style=\"color: red;\"\u003eManual\u003c\/span\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/MAN_GA_MSC2_MSB2_CO2Meter-compressed_1.pdf?v=1755194606\"\u003e\u003c\/a\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"accessories\"\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003c\/div\u003e","brand":"CO2Meter","offers":[{"title":"MSC2-NH3-System Ammonia (NH3) Fixed Gas Detection System | Industrial Refrigeration \u0026 Facility Gas Monitoring System","offer_id":43731097747654,"sku":"MSC2-NH3-System","price":2999.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/MSC2-NH3-System-Fixed-Ammonia-System-Remote-2-Horn-Strobes.jpg?v=1775501498"},{"product_id":"co2-nh3-fixed-gas-detection-system-refrigeration","title":"CO2 \u0026 NH3 Fixed Gas Detection System for Refrigeration Systems | Ammonia \u0026 CO2 Leak Detection with Alarms","description":"\u003cdiv style=\"text-align: left;\"\u003e🚨 Protect Refrigeration Systems from CO2 \u0026amp; Ammonia Leaks \u003c\/div\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\n\u003cp data-start=\"303\" data-end=\"548\"\u003eThe \u003cspan style=\"color: rgb(21, 94, 103);\"\u003e\u003cstrong data-start=\"307\" data-end=\"387\"\u003eMSC2-CO2-NH3 System: CO2 \u0026amp; NH3 Fixed Gas Detection System for Refrigeration\u003c\/strong\u003e\u003c\/span\u003e is an industrial-grade multi-gas safety solution designed for continuous monitoring of carbon dioxide (CO2) and ammonia (NH3) in refrigeration environments.\u003c\/p\u003e\n\u003cp data-start=\"835\" data-end=\"1034\"\u003eThis system delivers real-time gas monitoring, dual-gas detection, and automated alarm response, helping facilities prevent exposure incidents, equipment damage, and costly compliance violations.\u003c\/p\u003e\n\u003cp data-start=\"1036\" data-end=\"1446\"\u003eBuilt on the\u003cstrong\u003e \u003c\/strong\u003eMSC2 multi-gas safety platform, this solution uses remote sensors to detect leaks at the source, triggering alarms, activating ventilation systems, and integrating with facility controls for rapid mitigation.\u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003ch2\u003eFeatures\u003c\/h2\u003e\n\u003cul data-start=\"1466\" data-end=\"2186\"\u003e\n\u003cli data-section-id=\"1azctjq\" data-start=\"1466\" data-end=\"1549\"\u003eDual Gas Monitoring (CO2 + NH3)\u003c\/li\u003e\n\u003cli data-section-id=\"11v4r3m\" data-start=\"1550\" data-end=\"1645\"\u003eRemote Sensor Detection \u003c\/li\u003e\n\u003cli data-section-id=\"1hndql7\" data-start=\"1646\" data-end=\"1744\"\u003eBuilt for Refrigeration Systems \u003c\/li\u003e\n\u003cli data-section-id=\"uni7vh\" data-start=\"1745\" data-end=\"1824\"\u003eAudio\/Visual Alarms + Relays \u003c\/li\u003e\n\u003cli data-section-id=\"cb9ibg\" data-start=\"1825\" data-end=\"1897\"\u003eMulti-Gas Expandable Platform\u003c\/li\u003e\n\u003cli data-section-id=\"12qds8q\" data-start=\"1898\" data-end=\"1965\"\u003eBMS \u0026amp; PLC Integration Ready\u003c\/li\u003e\n\u003cli data-section-id=\"189szap\" data-start=\"1966\" data-end=\"2051\"\u003eCustom Configurations\u003c\/li\u003e\n\u003cli data-section-id=\"dosia2\" data-start=\"2052\" data-end=\"2108\"\u003eFlexible Power Options \u003c\/li\u003e\n\u003cli data-section-id=\"10sfp2m\" data-start=\"2109\" data-end=\"2186\"\u003eIP65 Rugged Enclosure\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 data-section-id=\"8bgedh\" data-start=\"316\" data-end=\"340\"\u003e\u003cspan role=\"text\"\u003e📦 What’s Included?\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli data-section-id=\"o7eaji\" data-start=\"342\" data-end=\"534\"\u003eMSC2 Fixed Gas Detection Controller (Main Display Unit)\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1d98puf\" data-start=\"536\" data-end=\"711\"\u003e(2) Remote Sensors (CO2) + (NH3)\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"v4fgr9\" data-start=\"713\" data-end=\"871\"\u003e(2) Audible \u0026amp; Visual Horn\/Strobe Alarms\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1su4yby\" data-start=\"873\" data-end=\"1040\"\u003ePre-Configured Alarm Relays \u003cbr\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1p90s8v\" data-start=\"1042\" data-end=\"1175\"\u003ePower Supply Compatibility (100–240 VAC \/ 24 VDC)\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1tk51f0\" data-start=\"1177\" data-end=\"1305\"\u003eWall-Mount Hardware \u0026amp; Installation Kit\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"jsmk4n\" data-start=\"1307\" data-end=\"1422\"\u003eUser Manual \u0026amp; Quick Start Guide\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv class=\"specifications\"\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCO2 Measurement Range:\u003c\/strong\u003e 0–5,000 ppm (custom ranges available)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNH3 Measurement Range:\u003c\/strong\u003e 0–100 ppm (expandable up to 5,000 ppm)\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eGas Types: \u003c\/b\u003eCarbon Dioxide (CO2) + Ammonia (NH3)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHousing Type C\/E: \u003c\/strong\u003ePolycarbonate\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInstallation: \u003c\/strong\u003eWall Mounted\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eKnockouts for Cable Entry: \u003c\/strong\u003eStandard 6x M20\/25\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIngress Protection: \u003c\/strong\u003eIP65\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTemperature Range: \u003c\/strong\u003e-13°F to 140°F (-25°C to 60°C)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHumidity Range: \u003c\/strong\u003e15-95% RH non-condensing\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Supply:\u003c\/strong\u003e 100-240 VAC or 24VDC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Consumption: \u003c\/strong\u003e24 VDC | Max. 60 mA (1.5 VA), w\/ sensor, w\/o WAO\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAlarm Relay (3): \u003c\/strong\u003e5 A Dry Contact Configurable\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTransistor Output (2):\u003c\/strong\u003e 24 VDC\/0.1 A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAnalog Input (2\/3): \u003c\/strong\u003e4-20mA compatible\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAnalog Output Signal (1): \u003c\/strong\u003eFault \u0026amp; range monitoring included\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eController Dimensions:\u003c\/strong\u003e 5.12 x 5.12 x 2.95 in. (130 x 130 x 75 mm)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eController Weight:\u003c\/strong\u003e 1.32 lbs. (0.6 kg)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"specifications\"\u003e\n\u003ch3\u003eWarranty\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e1 year - See \u003cstrong\u003e\u003ca title=\"CO2Meter Terms and Conditions\" href=\"https:\/\/www.co2meter.com\/pages\/terms-conditions\"\u003eCO2Meter Terms and Conditions.\u003c\/a\u003e\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"documents\"\u003e\n\u003cdiv class=\"data-sheets\"\u003e\n\u003ch2\u003eDocuments\u003c\/h2\u003e\n\u003cp style=\"text-align: left;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/CO2METER_PDF.png?1093\" alt=\"Gaslab Fixed Gas Detector DataSheet\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/MSC2-CO2-NH3-SYSTEM_-_Carbon_Dioxide_CO2_Ammonia_NH3_Fixed_Gas_Safety_Detection_System.pdf\" title=\"Gaslab Fixed Gas Detector Datasheet\" rel=\"noopener\" target=\"_blank\"\u003e\u003cstrong\u003e\u003cspan style=\"color: red;\"\u003eData Sheet (pdf) - MSC2 Detector\u003c\/span\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"manuals\"\u003e\n\u003cp style=\"text-align: left;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/CO2METER_PDF.png?1093\" alt=\"Gaslab Fixed Ammonia Gas Detector\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/MAN_GA_MSC2_MSB2_CO2Meter-compressed_1.pdf?v=1755194606\"\u003e\u003cstrong\u003e\u003cspan style=\"color: red;\"\u003eManual\u003c\/span\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/MAN_GA_MSC2_MSB2_CO2Meter-compressed_1.pdf?v=1755194606\"\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"CO2Meter","offers":[{"title":"MSC2-CO2-NH3-System: CO2 \u0026 NH3 Fixed GAs Detection System for Refrigeration Systems","offer_id":43772900475078,"sku":"MSC2-CO2-NH3-System","price":3899.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/MSC2-Fixed-CO2-NH3-System-2_Remote-2-Horn-Strobes.jpg?v=1775751643"},{"product_id":"hydrogen-h2-combustible-fixed-gas-detector","title":"Hydrogen (H2) Combustible Fixed Gas Detector (0-1000ppm)","description":"\u003cp\u003e\u003cspan style=\"color: #115e67;\"\u003e\u003cspan style=\"color: rgb(0, 0, 0);\"\u003eThe\u003c\/span\u003e\u003cstrong\u003e Hydrogen (H2) Combustible Fixed Gas Detector \u003c\/strong\u003e\u003c\/span\u003eis designed for continuous monitoring of hydrogen toxic gases between 0-1000ppm and vapors in hazardous areas of zones 1 and 2.\u003c\/p\u003e\n\u003cp\u003eThis detector is an explosion-proof \u003cspan\u003efixed H2 gas detector, which measures between 0 - 1000 ppm. The detector also is based with a 4-20 mA \/ RS485 Modbus output signal, alarm and fault relays (all SIL2 certified) for monitoring the ambient air to detect toxic gases.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThis solution is ideal for those industries using toxic gases such as oil\/gas, mining, refining, petroleum extraction, and industrial manufacturing applications.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003eFeatures\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eModular industrial design, protection class IP66\u003c\/li\u003e\n\u003cli\u003eEx db: Ignition protection for zone 1 and 2\u003c\/li\u003e\n\u003cli\u003eEx nR: Ignition protection for zone 2\u003c\/li\u003e\n\u003cli\u003eFast and Precise H2 Measurements 0-1000ppm\u003c\/li\u003e\n\u003cli\u003eCompatible across a broad range of BMS\u003c\/li\u003e\n\u003cli\u003eDevice can be used independent of control systems\u003c\/li\u003e\n\u003cli\u003eIndividual configuration options available\u003c\/li\u003e\n\u003cli\u003eRobust against dust, humidity, and high\/low temperatures\u003c\/li\u003e\n\u003cli\u003eSuitable for multiple industries and applications\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eCertifications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eATEX and IECEx certificates MSR-Electronic GmbH for electrical Ex protection\u003c\/li\u003e\n\u003cli\u003eSIL2 safety functions 4–20 mA, RS-485 and relay\u003c\/li\u003e\n\u003cli\u003ePX2-1 for zone 1 (and also suitable for zone 2):\u003c\/li\u003e\n\u003cli\u003eType “Ex db” protection flame-proof enclosure\u003c\/li\u003e\n\u003cli\u003ePX2-2 for zone 2\u003c\/li\u003e\n\u003cli\u003eType “Ex nR” protection\u003c\/li\u003e\n\u003cli\u003eEnclosure: Additional FM and CSA certificates for Class I, Div. 1\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eModels\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePX2-1-2-E1110-C-01 - \u003c\/strong\u003eGaslab Fixed Combustible Carbon Monoxide Detector\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePX2-1-2-E1130-E-01 - \u003c\/strong\u003eGaslab Fixed Combustible Nitrogen Dioxide Detector\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePX2-1-2-E1125-A-01 - \u003c\/strong\u003eGaslab Fixed Combustible Ammonia Detector\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePX2-1-2-E1195-A5-01 - \u003c\/strong\u003eGaslab Fixed Combustible Oxygen Detector\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePX2-1-2-E1197-B-01 - \u003c\/strong\u003eGaslab Fixed Combustible Hydrogen Sulfide Detector\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePX2-1-2-I464-C-01 - \u003c\/strong\u003eGaslab Fixed Combustible Carbon Dioxide Detector\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePX2-1-2-P3400-A-01 - \u003c\/strong\u003eGaslab Fixed Combustible Methane Detector\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePX2-1-2-P3480-A-01 - \u003c\/strong\u003eGaslab Fixed Combustible Propane Detector\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eWarranty\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e1-year warranty - see \u003ca title=\"View CO2Meter.com Terms and Conditions\" href=\"\/en-au\/pages\/terms-conditions\"\u003eCO2Meter Terms \u0026amp; Conditions\u003c\/a\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv class=\"specifications\"\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eGas Type:\u003c\/strong\u003e Hydrogen\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRange ppm:\u003c\/strong\u003e 0-1000ppm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAdmissible Range for Calibration Zero PPM:\u003c\/strong\u003e ± 10 % of measuring range\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAdmissible Range for Calibration Gain Test Gas:\u003c\/strong\u003e 30–120 % of test gas5\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTemperature Range: \u003c\/strong\u003e-30 to +50°C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStorage Temperature Range: \u003c\/strong\u003e0–20°C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHumidity Range: \u003c\/strong\u003e15-90 %RH\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePressure Range: \u003c\/strong\u003e80–120 kPa\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eReaction Time:\u003c\/strong\u003e ≤ 10 sec.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRun-in time2:\u003c\/strong\u003e 24 h\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFlow Rate:\u003c\/strong\u003e 500 ml\/min\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWarm-up Time:\u003c\/strong\u003e 300 Sec.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eResponse Time: \u003c\/strong\u003e≤ 200 Sec.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLife-time: \u003c\/strong\u003e\u0026gt;15 Years\u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"documents\"\u003e\n\u003ch3\u003eDocuments\u003c\/h3\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/PX2-1-2-E1194-A-01_Gaslab_Fixed_Combustible_Hydrogen_Detector_0-1000ppm_H2.pdf?v=1719896057\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/CO2METER_PDF.png?1094\" alt=\"Gaslab Fixed Combustible H2 Detector\"\u003e\u003c\/a\u003e\u003cspan\u003e\u003c\/span\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/PX2-1-2-E1194-A-01_Gaslab_Fixed_Combustible_Hydrogen_Detector_0-1000ppm_H2.pdf?v=1725040101\" title=\"Gaslab Fixed Combustible H2 Detector\"\u003e\u003cstrong\u003e\u003cspan style=\"color: #ff0000;\" color=\"#ff0000\"\u003eData Sheet (pdf)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/MAN_GA_PX2_Ex_Tox_CO2Meter_1.pdf?v=1755545267\" title=\"Manual Combustible Fixed Gas Detector - CO2Meter\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/CO2METER_PDF.png?1094\" alt=\"Gaslab Fixed Combustible NH3 Detector\"\u003e\u003cstrong\u003e\u003cspan style=\"color: #ff0000;\" color=\"#ff0000\"\u003e Manual (pdf)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/MAN_GA_PX2_Ex_Tox_CO2Meter.pdf?v=1716564528\"\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e","brand":"CO2 Meter","offers":[{"title":"PX2-1-2-E1194-A-01: Hydrogen (H2) Combustible Fixed Gas Detector (0-1000ppm)","offer_id":43920596500678,"sku":"PX2-1-2-E1194-A-01","price":1629.0,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/PX2-1-2-E1194-A-01___800x800_5650503e-248c-46f5-a909-0848e08a044f.jpg?v=1753283941"},{"product_id":"fixed-hydrogen-h2-gas-detection-system","title":"Hydrogen (H2) Fixed Gas Detection System | Industrial Gas Leak Detection \u0026 Safety Monitoring System","description":"\u003cdiv style=\"text-align: left;\"\u003e\n\u003cp data-start=\"270\" data-end=\"533\"\u003eThe \u003cspan style=\"color: rgb(17, 94, 103);\"\u003e\u003cstrong data-start=\"274\" data-end=\"344\"\u003eHydrogen (H₂) Fixed Gas Detection System with Remote Sensor (MSC2)\u003c\/strong\u003e\u003c\/span\u003e is an industrial-grade hydrogen gas detector designed for continuous H2 monitoring in high-risk environments such as energy systems, battery storage, welding and manufacturing facilities.\u003c\/p\u003e\n\u003cp data-start=\"535\" data-end=\"860\"\u003eHydrogen is a highly flammable gas that can ignite at low concentrations and disperse rapidly, making early detection critical. This fixed hydrogen gas detection system provides real-time leak monitoring, rapid alarm response and system integration to help prevent explosions, equipment damage, and safety incidents.\u003c\/p\u003e\n\u003cp data-start=\"862\" data-end=\"1111\"\u003eBuilt on the flexible MSC2 multi-gas safety platform, this system uses a remote hydrogen gas sensor to detect leaks at the source, trigger alarms, activate ventilation systems and integrate with BMS for immediate response.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003ch2\u003eFeatures\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli data-section-id=\"5skc37\" data-start=\"1131\" data-end=\"1203\"\u003e🔥 \u003cstrong data-start=\"1136\" data-end=\"1164\"\u003eContinuous H₂ Monitoring\u003c\/strong\u003e \u003c\/li\u003e\n\u003cli data-section-id=\"notiu7\" data-start=\"1204\" data-end=\"1269\"\u003e📡 \u003cstrong data-start=\"1209\" data-end=\"1236\"\u003eRemote Sensor Detection\u003c\/strong\u003e \u003c\/li\u003e\n\u003cli data-section-id=\"1523hzl\" data-start=\"1270\" data-end=\"1339\"\u003e🏭 \u003cstrong data-start=\"1275\" data-end=\"1302\"\u003eIndustrial-Grade Design\u003c\/strong\u003e \u003c\/li\u003e\n\u003cli data-section-id=\"odmbzr\" data-start=\"1340\" data-end=\"1417\"\u003e⚠️ \u003cstrong data-start=\"1345\" data-end=\"1377\"\u003eAudio\/Visual Alarms + Relays\u003c\/strong\u003e \u003c\/li\u003e\n\u003cli data-section-id=\"fo9vbv\" data-start=\"1418\" data-end=\"1480\"\u003e🔄 \u003cstrong data-start=\"1423\" data-end=\"1447\"\u003eMulti-Gas Expandable\u003c\/strong\u003e \u003c\/li\u003e\n\u003cli data-section-id=\"9b9z3w\" data-start=\"1481\" data-end=\"1537\"\u003e🔌 \u003cstrong data-start=\"1486\" data-end=\"1511\"\u003eBMS \u0026amp; PLC Integration\u003c\/strong\u003e \u003c\/li\u003e\n\u003cli data-section-id=\"s5looo\" data-start=\"1538\" data-end=\"1618\"\u003e🛠️ \u003cstrong data-start=\"1544\" data-end=\"1569\"\u003eCustom Configurations\u003c\/strong\u003e \u003c\/li\u003e\n\u003cli data-section-id=\"dosia2\" data-start=\"1619\" data-end=\"1675\"\u003e⚡ \u003cstrong data-start=\"1623\" data-end=\"1649\"\u003eFlexible Power Options\u003c\/strong\u003e \u003c\/li\u003e\n\u003cli data-section-id=\"yrpvr4\" data-start=\"1676\" data-end=\"1739\"\u003e🧱 \u003cstrong data-start=\"1681\" data-end=\"1706\"\u003eIP65 Rugged Enclosure\u003c\/strong\u003e \u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 data-end=\"1768\" data-start=\"1746\" data-section-id=\"101sl6h\"\u003e📦 What’s Included?\u003c\/h2\u003e\n\u003cul data-end=\"2090\" data-start=\"1770\"\u003e\n\u003cli data-end=\"1829\" data-start=\"1770\" data-section-id=\"438bkx\"\u003eMSC2 Fixed Gas Detection Controller (Main Display Unit)\u003c\/li\u003e\n\u003cli data-end=\"1869\" data-start=\"1830\" data-section-id=\"owp0q8\"\u003e(1) Remote Hydrogen (H2) Gas Sensor\u003c\/li\u003e\n\u003cli data-end=\"1913\" data-start=\"1870\" data-section-id=\"zyx6sy\"\u003e(2) Audible \u0026amp; Visual Horn\/Strobe Alarms\u003c\/li\u003e\n\u003cli data-end=\"1957\" data-start=\"1914\" data-section-id=\"io3u1f\"\u003ePre-Configured Alarm Relays (3 Outputs)\u003c\/li\u003e\n\u003cli data-end=\"2011\" data-start=\"1958\" data-section-id=\"1hwy61f\"\u003ePower Supply Compatibility (100–240 VAC \/ 24 VDC)\u003c\/li\u003e\n\u003cli data-end=\"2054\" data-start=\"2012\" data-section-id=\"1kfu224\"\u003eWall-Mount Hardware \u0026amp; Installation Kit\u003c\/li\u003e\n\u003cli data-end=\"2090\" data-start=\"2055\" data-section-id=\"12t0ca\"\u003eUser Manual \u0026amp; Quick Start Guide\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv class=\"specifications\"\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMeasurement Range:\u003c\/strong\u003e 0-1000ppm H2\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eGas: \u003c\/b\u003eHydrogen (H2)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHousing Type C\/E: \u003c\/strong\u003ePolycarbonate\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInstallation: \u003c\/strong\u003eWall Mounted\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eKnockouts for Cable Entry: \u003c\/strong\u003eStandard 6x M20\/25\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIngress Protection: \u003c\/strong\u003eIP65\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTemperature Range: \u003c\/strong\u003e-13°F to 140°F (-30°C to 50°C\u003cstrong\u003e)\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHumidity Range: \u003c\/strong\u003e15-90% RH non-condensing\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStorage Temperature: \u003c\/strong\u003e-4°F to 149°F (0° to 20°C)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Supply:\u003c\/strong\u003e 100-240 VAC or 24VDC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Consumption: \u003c\/strong\u003e24 V DC | Max. 60 mA (1.5 VA), w\/ sensor, w\/o WAO\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAlarm Relay (3): \u003c\/strong\u003e5 A Dry Contact Configurable\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTransistor Output (2):\u003c\/strong\u003e 24 V DC\/0.1 A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAnalog Input (2\/3): \u003c\/strong\u003e4-20mA, overload and short-circuit proof, input resistance 130 proportional, overload and short-circuit proof, load ≤ 500 4–20 mA = measuring range\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAnalog Output Signal (1):\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003e2.4–\u0026lt; 4 mA = tolerable under range\u003c\/li\u003e\n\u003cli\u003e20–21.2 mA = tolerable over range \u003c\/li\u003e\n\u003cli\u003e≥ 21,2 mA= error over range\u003c\/li\u003e\n\u003cli\u003e≤ 2,0 mA = fault\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eController Dimensions:\u003c\/strong\u003e 5.12 x 5.12 x 2.95 in. (130 x 130 x 75 mm)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eController Weight:\u003c\/strong\u003e 1.32 lbs. (0.6 kg)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"specifications\"\u003e\n\u003ch3\u003eWarranty\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e1 year - See \u003cstrong\u003e\u003ca href=\"https:\/\/www.co2meter.com\/pages\/terms-conditions\" title=\"CO2Meter Terms and Conditions\"\u003eCO2Meter Terms and Conditions\u003c\/a\u003e\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"documents\"\u003e\n\u003cdiv class=\"data-sheets\"\u003e\n\u003cp style=\"text-align: left;\"\u003e\u003ca title=\"Gaslab Fixed Hydrogen Gas Detector Datasheet\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/DS_-_MSC2-H2-System-Fixed-Hydrogen-System-Remote-2-Horn-Strobes.pdf?v=1775757717\" target=\"_blank\"\u003e\u003cimg alt=\"Fixed Hydrogen Industrial Gas Detector DataSheet\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/CO2METER_PDF.png?1093\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/DS_-_MSC2-H2-System-Fixed-Hydrogen-System-Remote-2-Horn-Strobes.pdf?v=1775757717\" title=\"Fixed Hydrogen Industrial Gas Detector Datasheet\" rel=\"noopener\" target=\"_blank\"\u003e\u003cstrong\u003e\u003cspan style=\"color: red;\"\u003eData Sheet - MSC2 Fixed Controller (pdf)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003cstrong\u003e\u003cspan style=\"color: red;\"\u003e\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"manuals\"\u003e\n\u003cp style=\"text-align: left;\"\u003e\u003cimg alt=\"Gaslab Fixed Hydrogen Gas Detector\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/CO2METER_PDF.png?1093\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/MAN_GA_MSC2_MSB2_CO2Meter-compressed_1.pdf?v=1755194606\"\u003e\u003cstrong\u003e\u003cspan style=\"color: red;\"\u003eManual\u003c\/span\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/MAN_GA_MSC2_MSB2_CO2Meter-compressed_1.pdf?v=1755194606\"\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"CO2Meter","offers":[{"title":"Hydrogen (H2) Fixed Gas Detection System | Industrial Gas Leak Detection \u0026 Safety Monitoring System","offer_id":43920615342278,"sku":"MSC2-H2-System","price":2899.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/MSC2-H2-System-Fixed-Hydrogen-System-Remote-2-Horn-Strobes.jpg?v=1775502911"},{"product_id":"digital-multi-gas-controller-system","title":"Digital Multi-Gas Controller System","description":"\u003cp style=\"text-align: left;\"\u003eThe \u003cspan style=\"color: #115e67;\"\u003e\u003cstrong\u003eDGC-06: Digital Multi-Gas Controller System \u003c\/strong\u003e\u003c\/span\u003eis used for the monitoring and warning of toxic and combustible gases and vapors, as well as refrigerants within a wide range of gas measurements.\u003c\/p\u003e\n\u003cp style=\"text-align: left;\"\u003eThe controller system is designed to monitor and manage up to \u003cstrong\u003e128 gas options\u003c\/strong\u003e, 96 digital sensors, and 32 analog sensor options. The controller series also provides 4 free adjustable alarm thresholds with each provided sensor. \u003c\/p\u003e\n\u003cp\u003eThe \u003cstrong\u003eDGC-06\u003c\/strong\u003e also meets most gas safety code requirements, standards, and conformities along fulfilling current EN50545-1 CO monitoring, EN 378, VBG 20 NH3 monitoring and more.\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"color: rgb(255, 42, 0);\"\u003e\u003cstrong\u003e*This digital multi-gas controller system ONLY works in conjunction with our Fixed Multi-Gas Detector Series or Combustible Fixed Gas Detectors.*\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eModular, easy to use, for large facilities\u003c\/li\u003e\n\u003cli\u003e128 gas sensor capabilities\u003c\/li\u003e\n\u003cli\u003e4 free adjustable alarm thresholds per sensor\u003c\/li\u003e\n\u003cli\u003e5 menu languages, free adjustable settings\u003c\/li\u003e\n\u003cli\u003eSeveral alarm relays configurable per alarm\u003c\/li\u003e\n\u003cli\u003eAlarm release by falling or increasing gas concentrations\u003c\/li\u003e\n\u003cli\u003eConnector for PCE06 Software at the controller module\u003c\/li\u003e\n\u003cli\u003eFlexible configuration and programmable parameters\/set points\u003c\/li\u003e\n\u003cli\u003eWarning buzzer\/LED alarm, fault + operation option\u003c\/li\u003e\n\u003cli\u003eCompatible with a wide range of BMS\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eSIL2 Level Compliant\u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv class=\"specifications\"\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMeasurement Range:\u003c\/strong\u003e Dependent upon gas sensors selected\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eGas Type: \u003c\/b\u003eDependent upon gas sensors selected\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHousing Type C\/E: \u003c\/strong\u003ePlastic Housing with View Cover\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInstallation: \u003c\/strong\u003eWall Mounted\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eKnockouts for Cable Entry: \u003c\/strong\u003eStandard 6x M20\/25\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIngress Protection: \u003c\/strong\u003eIP65\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTemperature Range: \u003c\/strong\u003e23 °F to 104 °F (-5 °C to +40 °C)\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStorage Temp Range: \u003c\/strong\u003e32 °F to 104 °F (0°C to +40°C)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHumidity Range: \u003c\/strong\u003e15-95% RH non-condensing\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Supply:\u003c\/strong\u003e 90\/230 V AC, 50\/60 Hz; 24VDC ± 20 %\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Consumption: \u003c\/strong\u003eMin. 30W, 0.15A, max. ca. 160W, 0.7A, depending on type\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAnalog Input (4 to max. 32): \u003c\/strong\u003e4–20 mA, overload and short-circuit proof, input resistance 130\u003cspan\u003eµ\u003c\/span\u003e\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTension for external analog transmitter: \u003c\/strong\u003e24VDC ±20 %, max130mA - per sensor\u003c\/li\u003e\n\u003cli style=\"font-weight: bold;\"\u003e\n\u003cstrong\u003eAnalog output (max 16) configurable for each input:\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli style=\"font-weight: bold;\"\u003e\u003cstrong\u003eProportional, overload and short-circuit proof, charge ≤ 500µ\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: bold;\"\u003e\u003cstrong\u003e 4–20 mA = measuring range \u003c\/strong\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: bold;\"\u003e\u003cstrong\u003e3.0–\u0026lt;4 mA = under range \u003c\/strong\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: bold;\"\u003e\u003cstrong\u003e\u0026gt; 20–21.2 mA = over range\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: bold;\"\u003e\u003cstrong\u003e 2.0 mA = fault\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRelay (max. 32): \u003c\/strong\u003e250 VAC, 5 A; 30 V DC, 2 A, potential-free, change-over (SPDT)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFault relay (1): \u003c\/strong\u003e250VAC, 5A; 30VDC, 2A, potential-free, normally open contact (SPST)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMenu Language (selectable): \u003c\/strong\u003eGerman, English, French, or Italian\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTransceiver: \u003c\/strong\u003eRS485 \/ 19200 Baud\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDimensions: \u003c\/strong\u003eW x H x D - 11.7 x 10.2 x 5.5 in. | (298 x 260 x 140 mm)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight: \u003c\/strong\u003eMin. 4.4 Ib. (2.7 kg), max. 28.7 Ibs. (13 kg) depending on type\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e 1.32 lbs. (0.6 kg)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eRegulations\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eEMC Directive 2014\/30\/EU\u003c\/li\u003e\n\u003cli\u003eLow Voltage Directive 2014\/35\/EU\u003c\/li\u003e\n\u003cli\u003eEN 50271\u003c\/li\u003e\n\u003cli\u003eEN 61010-1:2010\u003c\/li\u003e\n\u003cli\u003eANSI\/UL 61010-1\u003c\/li\u003e\n\u003cli\u003eCAN\/CSA-C22.2 No. 61010-1\u003c\/li\u003e\n\u003cli\u003eEN 50545-1\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"specifications\"\u003e\n\u003ch3\u003eWarranty\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e1 year - See \u003cstrong\u003e\u003ca title=\"CO2Meter Terms and Conditions\" href=\"https:\/\/www.co2meter.com\/pages\/terms-conditions\"\u003eCO2Meter Terms and Conditions\u003c\/a\u003e\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"documents\"\u003e\n\u003cdiv class=\"data-sheets\"\u003e\n\u003cp style=\"text-align: left;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/DS-DGC-06-ALL-CO2Meter-2024Y.pdf?v=1721232679\" title=\"Digital Multi-Gas Controller System Datasheet\" target=\"_blank\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/CO2METER_PDF.png?1093\" alt=\"Digital Multi-Gas Controller System DataSheet\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/DS-DGC-06-ALL-CO2Meter-2024Y.pdf\" target=\"_blank\" title=\"Digital Multi-Gas Controller System Datasheet\" rel=\"noopener\"\u003e\u003cstrong\u003e\u003cspan style=\"color: red;\"\u003eData Sheet (pdf)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"manuals\"\u003e\n\u003cp style=\"text-align: left;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/CO2METER_PDF.png?1093\" alt=\"Digital Multi-Gas Controller System\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/DGC06_Digital_Gas_Controller_CO2Meter-compressed.pdf?v=1755187339\"\u003e\u003cstrong\u003e\u003cspan style=\"color: red;\"\u003eManual\u003c\/span\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/DGC06_Digital_Gas_Controller_CO2Meter-compressed.pdf?v=1755187339\"\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"accessories\"\u003e\n\u003ch3\u003eOptions\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca title=\"Fixed Multi Gas Detector\" href=\"https:\/\/www.co2meter.com\/products\/fixed-multi-gas-detector\"\u003e\u003cstrong\u003eMSC-2 \u003c\/strong\u003e| Multi-Gas Fixed Gas Detector\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSC2-E1110-A-P-00\u003c\/strong\u003e | CO Digital Sensor for MSC2\u003ca href=\"\/en-au\/collections\/restaurants-food\/products\/remote-co2-storage-safety-alarm-strobe-lights\" title=\"CO2Meter CM-1027 Safety Alarm Strobe Lights\" target=\"_blank\"\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/a\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSC2-E1130-B-P-00\u003c\/strong\u003e | NO2 Digital Sensor for MSC2\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSC2-E1194-A-P-00\u003c\/strong\u003e | H2 Digital Sensor for MSC2\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSC2-E1195-A2-P-00\u003c\/strong\u003e | O2 Digital Sensor for MSC2\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSC2-I464-B-P-00\u003c\/strong\u003e | CO2 Digital Sensor for MSC2\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"text-align: center;\"\u003e\u003cspan style=\"text-decoration: underline;\"\u003e\u003cstrong\u003e\u003cspan style=\"color: rgb(11, 95, 220); text-decoration: underline;\"\u003eLooking for More? View our full list of gas sensor capabilities and options here\u003c\/span\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cbr\u003e\n\u003c\/div\u003e","brand":"CO2Meter","offers":[{"title":"DGC-06-0EP-DL: Gaslab Digital Gas Controller (no expansion modules) w\/ data logger","offer_id":45702019875014,"sku":"DGC-06-0EP-DL","price":3499.0,"currency_code":"USD","in_stock":true},{"title":"DGC-06-4EP: Gaslab Digital Gas Controller (4 Expansion Module)","offer_id":45702015385798,"sku":"DGC-06-4EP","price":3999.0,"currency_code":"USD","in_stock":true},{"title":"DGC-06-4EP-DL: Gaslab Digital Gas Controller (7 expansion modules) w\/ data logger","offer_id":45702020366534,"sku":"DGC-06-4EP-DL","price":4999.0,"currency_code":"USD","in_stock":true},{"title":"DGC-06-7EP: Gaslab Digital Gas Controller (7 expansion modules)","offer_id":45702019743942,"sku":"DGC-06-7EP","price":7499.0,"currency_code":"USD","in_stock":true},{"title":"DGC-06-7EP-DL: Gaslab Digital Gas Controller (7 Expansion Modules w\/ Data Logger)","offer_id":45702020694214,"sku":"DGC-06-7EP-DL","price":8499.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/DGC-06-0EP-Digital-Gas-Controller-no-expansion-pack-data-logger-CO2Meter.jpg?v=1775756721"},{"product_id":"carbon-monoxide-combustible-fixed-gas-detector-0-150ppm","title":"Carbon Monoxide (CO) Combustible Fixed Gas Detector (0-150ppm)","description":"\u003cp\u003e\u003cspan style=\"color: #115e67;\"\u003e\u003cspan style=\"color: rgb(0, 0, 0);\"\u003eThe\u003c\/span\u003e\u003cstrong\u003e Carbon Monoxide (CO) Combustible Fixed Gas Detector (PX2-1-2-E1110-C-01): \u003c\/strong\u003e\u003c\/span\u003eis designed for continuous monitoring of carbon dioxide gases to prevent leaks in the range of 0 to 150ppm for 24 hours in the confined space or automotive industries. \u003c\/p\u003e\n\u003cp\u003eThis detector is also compatible with a wide range of controlled BMS systems and alarms,\u003cspan\u003e is based with a 4-20 mA \/ RS485 Modbus output signal, alarm and fault relays (all SIL2 certified) for monitoring the ambient air to detect toxic gases.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThis solution is ideal for those industries using toxic gases such as car parks, automotive, refrigeration, chemical processing, and industrial manufacturing applications.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003eFeatures\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eModular industrial design, protection class IP66\u003c\/li\u003e\n\u003cli\u003eEx db: Ignition protection for zone 1 and 2\u003c\/li\u003e\n\u003cli\u003eEx nR: Ignition protection for zone 2\u003c\/li\u003e\n\u003cli\u003eFast and Precise CO Measurements 0-150ppm\u003c\/li\u003e\n\u003cli\u003eCompatible across a broad range of BMS\u003c\/li\u003e\n\u003cli\u003eDevice can be used independent of control systems\u003c\/li\u003e\n\u003cli\u003eIndividual configuration options available\u003c\/li\u003e\n\u003cli\u003eRobust against dust, humidity, and high\/low temperatures\u003c\/li\u003e\n\u003cli\u003eSuitable for multiple industries and applications\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eCertifications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eATEX and IECEx certificates MSR-Electronic GmbH for electrical Ex protection\u003c\/li\u003e\n\u003cli\u003eSIL2 safety functions 4–20 mA, RS-485 and relay\u003c\/li\u003e\n\u003cli\u003ePX2-1 for zone 1 (and also suitable for zone 2):\u003c\/li\u003e\n\u003cli\u003eType “Ex db” protection flame-proof enclosure\u003c\/li\u003e\n\u003cli\u003ePX2-2 for zone 2\u003c\/li\u003e\n\u003cli\u003eType “Ex nR” protection\u003c\/li\u003e\n\u003cli\u003eEnclosure: Additional FM and CSA certificates for Class I, Div. 1\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eModels\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePX2-1-2-E1130-E-01 - \u003c\/strong\u003eGaslab Fixed Combustible Nitrogen Dioxide Detector\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePX2-1-2-E1125-A-01 - \u003c\/strong\u003eGaslab Fixed Combustible Ammonia Detector\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePX2-1-2-E1195-A5-01 - \u003c\/strong\u003eGaslab Fixed Combustible Oxygen Detector\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePX2-1-2-E1197-B-01 - \u003c\/strong\u003eGaslab Fixed Combustible Hydrogen Sulfide Detector\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePX2-1-2-I464-C-01 - \u003c\/strong\u003eGaslab Fixed Combustible Carbon Dioxide Detector\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePX2-1-2-P3400-A-01 - \u003c\/strong\u003eGaslab Fixed Combustible Methane Detector\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePX2-1-2-P3480-A-01 - \u003c\/strong\u003eGaslab Fixed Combustible Propane Detector\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eWarranty\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e1-year warranty - see \u003ca href=\"\/en-au\/pages\/terms-conditions\" title=\"View CO2Meter.com Terms and Conditions\"\u003eCO2Meter Terms \u0026amp; Conditions\u003c\/a\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv class=\"specifications\"\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eGas Type:\u003c\/strong\u003e Carbon Monoxide\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRange ppm:\u003c\/strong\u003e 0-150ppm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAdmissible Range for Calibration Zero PPM:\u003c\/strong\u003e ± 10 % of measuring range\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAdmissible Range for Calibration Gain Test Gas:\u003c\/strong\u003e 30–120 % of test gas5\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTemperature Range: \u003c\/strong\u003e-30 to +50°C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStorage Temperature Range: \u003c\/strong\u003e0–20°C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHumidity Range: \u003c\/strong\u003e15-90 %RH\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePressure Range: \u003c\/strong\u003e80–120 kPa\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eReaction Time:\u003c\/strong\u003e ≤ 10 sec.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRun-in time2:\u003c\/strong\u003e 24 h\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFlow Rate:\u003c\/strong\u003e 500 ml\/min\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWarm-up Time:\u003c\/strong\u003e 300 Sec.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eResponse Time: \u003c\/strong\u003e≤ 200 Sec.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLife-time: \u003c\/strong\u003e\u0026gt;15 Years\u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"documents\"\u003e\n\u003ch3\u003eDocuments\u003c\/h3\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/PX2-1-2-E1110-C-01_Gaslab_Fixed_Combustible_Carbon_Monoxide_Detector_0-150ppm_CO.pdf?v=1721236547\"\u003e\u003cimg alt=\"Gaslab Fixed Combustible CO Detector\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/CO2METER_PDF.png?1094\"\u003e\u003c\/a\u003e\u003cspan\u003e\u003c\/span\u003e\u003ca title=\"Gaslab Fixed Combustible CO Detector\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/PX2-1-2-E1110-C-01_Gaslab_Fixed_Combustible_Carbon_Monoxide_Detector_0-150ppm_CO.pdf?v=1725039907\"\u003e\u003cstrong\u003e\u003cspan color=\"#ff0000\" style=\"color: #ff0000;\"\u003eData Sheet (pdf)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/MAN_GA_PX2_Ex_Tox_CO2Meter_1.pdf?v=1755545267\" title=\"Manual Combustible Fixed Gas Detector - CO2Meter\"\u003e\u003cimg alt=\"Gaslab Fixed Combustible NH3 Detector\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/CO2METER_PDF.png?1094\"\u003e\u003cstrong\u003e\u003cspan color=\"#ff0000\" style=\"color: #ff0000;\"\u003e Manual (pdf)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/MAN_GA_PX2_Ex_Tox_CO2Meter.pdf?v=1716564528\"\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e","brand":"CO2 Meter","offers":[{"title":"PX2-1-2-E1110-C-01: Carbon Monoxide (CO) Combustible Fixed Gas Detector (0-150ppm)","offer_id":43963095056582,"sku":"PX2-1-2-E1110-C-01","price":1589.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/PX2-1-2-E1110-C-01-Combustible-CO-Detector.jpg?v=1753283920"},{"product_id":"nitrogen-dioxide-combustible-fixed-gas-detector","title":"Nitrogen Dioxide (NO2) Combustible Fixed Gas Detector (0-100ppm)","description":"\u003cp\u003e\u003cspan style=\"color: #115e67;\"\u003e\u003cspan style=\"color: rgb(0, 0, 0);\"\u003eThe\u003c\/span\u003e\u003cstrong\u003e Nitrogen Dioxide (NO2) Combustible Fixed Gas Detector (PX2-1-2-E1130-E-01)\u003c\/strong\u003e\u003c\/span\u003e is designed for continuous monitoring of nitrogen dioxide gases to prevent leaks in the range of 0 to 100ppm for 24 hours in confined spaces or industrial manufacturing industries. \u003c\/p\u003e\n\u003cp\u003eThis detector is also compatible with a wide range of controlled BMS systems and alarms,\u003cspan\u003e is based with a 4-20 mA \/ RS485 Modbus output signal, alarm and fault relays (all SIL2 certified) for monitoring the ambient air to detect toxic gases.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThis solution is ideal for those industries using toxic gases such as food processing, cooling, preservation, healthcare, metal fabrication, welding and industrial manufacturing applications.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003eFeatures\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eModular industrial design, protection class IP66\u003c\/li\u003e\n\u003cli\u003eEx db: Ignition protection for zone 1 and 2\u003c\/li\u003e\n\u003cli\u003eEx nR: Ignition protection for zone 2\u003c\/li\u003e\n\u003cli\u003eFast and Precise NO2 Measurements 0-100ppm\u003c\/li\u003e\n\u003cli\u003eCompatible across a broad range of BMS\u003c\/li\u003e\n\u003cli\u003eDevice can be used independent of control systems\u003c\/li\u003e\n\u003cli\u003eIndividual configuration options available\u003c\/li\u003e\n\u003cli\u003eRobust against dust, humidity, and high\/low temperatures\u003c\/li\u003e\n\u003cli\u003eSuitable for multiple industries and applications\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eCertifications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eATEX and IECEx certificates MSR-Electronic GmbH for electrical Ex protection\u003c\/li\u003e\n\u003cli\u003eSIL2 safety functions 4–20 mA, RS-485 and relay\u003c\/li\u003e\n\u003cli\u003ePX2-1 for zone 1 (and also suitable for zone 2):\u003c\/li\u003e\n\u003cli\u003eType “Ex db” protection flame-proof enclosure\u003c\/li\u003e\n\u003cli\u003ePX2-2 for zone 2\u003c\/li\u003e\n\u003cli\u003eType “Ex nR” protection\u003c\/li\u003e\n\u003cli\u003eEnclosure: Additional FM and CSA certificates for Class I, Div. 1\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eModels\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePX2-1-2-E1110-C-01 - \u003c\/strong\u003eGaslab Fixed Combustible Carbon Monoxide Detector\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePX2-1-2-E1125-A-01 - \u003c\/strong\u003eGaslab Fixed Combustible Ammonia Detector\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePX2-1-2-E1195-A5-01 - \u003c\/strong\u003eGaslab Fixed Combustible Oxygen Detector\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePX2-1-2-E1197-B-01 - \u003c\/strong\u003eGaslab Fixed Combustible Hydrogen Sulfide Detector\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePX2-1-2-I464-C-01 - \u003c\/strong\u003eGaslab Fixed Combustible Carbon Dioxide Detector\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePX2-1-2-P3400-A-01 - \u003c\/strong\u003eGaslab Fixed Combustible Methane Detector\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePX2-1-2-P3480-A-01 - \u003c\/strong\u003eGaslab Fixed Combustible Propane Detector\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eWarranty\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e1-year warranty - see \u003ca href=\"\/en-au\/pages\/terms-conditions\" title=\"View CO2Meter.com Terms and Conditions\"\u003eCO2Meter Terms \u0026amp; Conditions\u003c\/a\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv class=\"specifications\"\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eGas Type:\u003c\/strong\u003e Nitrogen Dioxide\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRange ppm:\u003c\/strong\u003e 0-100ppm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAdmissible Range for Calibration Zero PPM:\u003c\/strong\u003e ± 10 % of measuring range\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAdmissible Range for Calibration Gain Test Gas:\u003c\/strong\u003e 30–120 % of test gas5\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTemperature Range: \u003c\/strong\u003e-30 to +50°C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStorage Temperature Range: \u003c\/strong\u003e0–20°C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHumidity Range: \u003c\/strong\u003e15-90 %RH\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePressure Range: \u003c\/strong\u003e80–120 kPa\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eReaction Time:\u003c\/strong\u003e ≤ 10 sec.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRun-in time2:\u003c\/strong\u003e 24 h\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFlow Rate:\u003c\/strong\u003e 500 ml\/min\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWarm-up Time:\u003c\/strong\u003e 300 Sec.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eResponse Time: \u003c\/strong\u003e≤ 200 Sec.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLife-time: \u003c\/strong\u003e\u0026gt;15 Years\u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"documents\"\u003e\n\u003ch3\u003eDocuments\u003c\/h3\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/PX2-1-2-E1130-E-01_Gaslab_Fixed_Combustible_Nitrogen_Detector_0-100ppm_NO2.pdf?v=1721237958\"\u003e\u003cimg alt=\"Gaslab Fixed Combustible NO2 Detector\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/CO2METER_PDF.png?1094\"\u003e\u003c\/a\u003e\u003cspan\u003e\u003c\/span\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/PX2-1-2-E1130-E-01_Gaslab_Fixed_Combustible_Nitrogen_Detector_0-100ppm_NO2.pdf?v=1725040038\" title=\"Gaslab Fixed Combustible NO2 Detector\"\u003e\u003cstrong\u003e\u003cspan color=\"#ff0000\" style=\"color: #ff0000;\"\u003eData Sheet (pdf)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca title=\"Manual Combustible Fixed Gas Detector - CO2Meter\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/MAN_GA_PX2_Ex_Tox_CO2Meter_1.pdf?v=1755545267\"\u003e\u003cimg alt=\"Gaslab Fixed Combustible NH3 Detector\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/CO2METER_PDF.png?1094\"\u003e\u003cstrong\u003e\u003cspan color=\"#ff0000\" style=\"color: #ff0000;\"\u003e Manual (pdf)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/MAN_GA_PX2_Ex_Tox_CO2Meter.pdf?v=1716564528\"\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e","brand":"CO2 Meter","offers":[{"title":"PX2-1-2-E1130-E-01: Nitrogen Dioxide Combustible Fixed Gas Detector (0-100ppm)","offer_id":43963127333062,"sku":"PX2-1-2-E1130-E-01","price":1629.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/PX2-1-2-E1130-E-01-Combustible-NO2-Detector.jpg?v=1753283919"},{"product_id":"oxygen-combustible-fixed-gas-detector","title":"Oxygen (O2) Combustible Fixed Gas Detector (0-25%)","description":"\u003cp\u003e\u003cspan style=\"color: #115e67;\"\u003e\u003cspan style=\"color: rgb(0, 0, 0);\"\u003eThe\u003c\/span\u003e\u003cstrong\u003e Oxygen (O2) Combustible Fixed Gas Detector (PX2-1-2-E1195-A5-01)\u003c\/strong\u003e\u003c\/span\u003e is designed for continuous monitoring of toxic gases to prevent leaks in the range of 0 to 25% for 24 hours in confined spaces or industrial applications.\u003c\/p\u003e\n\u003cp\u003eThis detector is also compatible with a wide range of controlled BMS systems and alarms,\u003cspan\u003e is based with a 4-20 mA \/ RS485 Modbus output signal, alarm and fault relays (all SIL2 certified) for monitoring the ambient air to detect toxic gases.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThis solution is ideal for those industries and storage facilities where oxygen may be depleted such as battery rooms, industrial areas, factory settings, processing, sterilization, cleaning, livestock, and many others.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003eFeatures\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eModular industrial design, protection class IP66\u003c\/li\u003e\n\u003cli\u003eEx db: Ignition protection for zone 1 and 2\u003c\/li\u003e\n\u003cli\u003eEx nR: Ignition protection for zone 2\u003c\/li\u003e\n\u003cli\u003eFast and Precise O2 Measurements 0-25%\u003c\/li\u003e\n\u003cli\u003eCompatible across a broad range of BMS\u003c\/li\u003e\n\u003cli\u003eDevice can be used independent of control systems\u003c\/li\u003e\n\u003cli\u003eIndividual configuration options available\u003c\/li\u003e\n\u003cli\u003eRobust against dust, humidity, and high\/low temperatures\u003c\/li\u003e\n\u003cli\u003eSuitable for multiple industries and applications\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eCertifications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eATEX and IECEx certificates MSR-Electronic GmbH for electrical Ex protection\u003c\/li\u003e\n\u003cli\u003eSIL2 safety functions 4–20 mA, RS-485 and relay\u003c\/li\u003e\n\u003cli\u003ePX2-1 for zone 1 (and also suitable for zone 2)\u003c\/li\u003e\n\u003cli\u003eType “Ex db” protection flame-proof enclosure\u003c\/li\u003e\n\u003cli\u003ePX2-2 for zone 2\u003c\/li\u003e\n\u003cli\u003eType “Ex nR” protection\u003c\/li\u003e\n\u003cli\u003eEnclosure: Additional FM and CSA certificates for Class I, Div. 1\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eModels\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePX2-1-2-E1110-C-01 - \u003c\/strong\u003eGaslab Fixed Combustible Carbon Monoxide Detector\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePX2-1-2-E1125-A-01 - \u003c\/strong\u003eGaslab Fixed Combustible Ammonia Detector\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePX2-1-2-E1130-E-01 - \u003c\/strong\u003eGaslab Fixed Combustible Nitrogen Dioxide Detector\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePX2-1-2-E1197-B-01 - \u003c\/strong\u003eGaslab Fixed Combustible Hydrogen Sulfide Detector\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePX2-1-2-I464-C-01 - \u003c\/strong\u003eGaslab Fixed Combustible Carbon Dioxide Detector\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePX2-1-2-P3400-A-01 - \u003c\/strong\u003eGaslab Fixed Combustible Methane Detector\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePX2-1-2-P3480-A-01 - \u003c\/strong\u003eGaslab Fixed Combustible Propane Detector\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eWarranty\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e1-year warranty - see \u003ca title=\"View CO2Meter.com Terms and Conditions\" href=\"\/en-au\/pages\/terms-conditions\"\u003eCO2Meter Terms \u0026amp; Conditions\u003c\/a\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv class=\"specifications\"\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eGas Type:\u003c\/strong\u003e Nitrogen Dioxide\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRange ppm:\u003c\/strong\u003e 0-100ppm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAdmissible Range for Calibration Zero PPM:\u003c\/strong\u003e ± 10 % of measuring range\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAdmissible Range for Calibration Gain Test Gas:\u003c\/strong\u003e 30–120 % of test gas5\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTemperature Range: \u003c\/strong\u003e-30 to +50°C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStorage Temperature Range: \u003c\/strong\u003e0–20°C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHumidity Range: \u003c\/strong\u003e15-90 %RH\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePressure Range: \u003c\/strong\u003e80–120 kPa\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eReaction Time:\u003c\/strong\u003e ≤ 10 sec.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRun-in time2:\u003c\/strong\u003e 24 h\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFlow Rate:\u003c\/strong\u003e 500 ml\/min\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWarm-up Time:\u003c\/strong\u003e 300 Sec.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eResponse Time: \u003c\/strong\u003e≤ 200 Sec.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLife-time: \u003c\/strong\u003e\u0026gt;15 Years\u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"documents\"\u003e\n\u003ch3\u003eDocuments\u003c\/h3\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/PX2-1-2-E1195-A2-01_Gaslab_Fixed_Combustible_Oxygen_Detector_0-25_02.pdf?v=1723212527\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/CO2METER_PDF.png?1094\" alt=\"Gaslab Fixed Combustible O2 Detector\"\u003e\u003c\/a\u003e\u003cspan\u003e\u003c\/span\u003e\u003ca title=\"Gaslab Fixed Combustible O2 Detector\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/PX2-1-2-E1195-A2-01_Gaslab_Fixed_Combustible_Oxygen_Detector_0-25_02.pdf?v=1725039673\"\u003e\u003cstrong\u003e\u003cspan style=\"color: #ff0000;\" color=\"#ff0000\"\u003eData Sheet (pdf)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/MAN_GA_PX2_Ex_Tox_CO2Meter_1.pdf?v=1755545267\" title=\"Manual Combustible Fixed Gas Detector - CO2Meter\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/CO2METER_PDF.png?1094\" alt=\"Gaslab Fixed Combustible NH3 Detector\"\u003e\u003cstrong\u003e\u003cspan style=\"color: #ff0000;\" color=\"#ff0000\"\u003e Manual (pdf)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/MAN_GA_PX2_Ex_Tox_CO2Meter.pdf?v=1716564528\"\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e","brand":"CO2 Meter","offers":[{"title":"PX2-1-2-E1195-A5-01: Oxygen Combustible Fixed Gas Detector (0-25%)","offer_id":43963186151622,"sku":"PX2-1-2-E1195-A5-01","price":2079.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/PX2-1-2-E1195-A2-01-Combustible-O2-Detector.jpg?v=1753283918"},{"product_id":"hydrogen-sulfide-h2s-combustible-fixed-gas-detector","title":"Hydrogen Sulfide (H2S) Combustible Fixed Gas Detector (0-100ppm)","description":"\u003cp\u003e\u003cspan style=\"color: #115e67;\"\u003e\u003cspan style=\"color: rgb(0, 0, 0);\"\u003eThe\u003c\/span\u003e\u003cstrong\u003e Hydrogen Sulfide (H2S) Combustible Fixed Gas Detector (PX2-1-2-E1197-B-01)\u003c\/strong\u003e\u003c\/span\u003e is designed for continuous monitoring of H2S gases between 0-100ppm and vapors in hazardous areas of zones 1 and 2.\u003c\/p\u003e\n\u003cp\u003eThis detector is an explosion-proof \u003cspan\u003efixed H2S gas detector, based with a 4-20 mA \/ RS485 Modbus output signal, alarm and fault relays (all SIL2 certified) for monitoring the ambient air to detect toxic gases.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThis solution is ideal for those industries with dense magnetic or electronic products, such as tunnels, mines, confined spaces or industrial processing applications.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003eFeatures\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eModular industrial design, protection class IP66\u003c\/li\u003e\n\u003cli\u003eEx db: Ignition protection for zone 1 and 2\u003c\/li\u003e\n\u003cli\u003eEx nR: Ignition protection for zone 2\u003c\/li\u003e\n\u003cli\u003eFast and Precise H2S Measurements 0-100ppm\u003c\/li\u003e\n\u003cli\u003eCompatible across a broad range of BMS\u003c\/li\u003e\n\u003cli\u003eDevice can be used independent of control systems\u003c\/li\u003e\n\u003cli\u003eIndividual configuration options available\u003c\/li\u003e\n\u003cli\u003eRobust against dust, humidity, and high\/low temperatures\u003c\/li\u003e\n\u003cli\u003eSuitable for multiple industries and applications\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eCertifications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eATEX and IECEx certificates MSR-Electronic GmbH for electrical Ex protection\u003c\/li\u003e\n\u003cli\u003eSIL2 safety functions 4–20 mA, RS-485 and relay\u003c\/li\u003e\n\u003cli\u003ePX2-1 for zone 1 (and also suitable for zone 2):\u003c\/li\u003e\n\u003cli\u003eType “Ex db” protection flame-proof enclosure\u003c\/li\u003e\n\u003cli\u003ePX2-2 for zone 2\u003c\/li\u003e\n\u003cli\u003eType “Ex nR” protection\u003c\/li\u003e\n\u003cli\u003eEnclosure: Additional FM and CSA certificates for Class I, Div. 1\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eModels\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePX2-1-2-E1110-C-01 - \u003c\/strong\u003eGaslab Fixed Combustible Carbon Monoxide Detector\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePX2-1-2-E1130-E-01 - \u003c\/strong\u003eGaslab Fixed Combustible Nitrogen Dioxide Detector\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePX2-1-2-E1194-A-01 - \u003c\/strong\u003eGaslab Fixed Combustible Hydrogen Detector\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePX2-1-2-E1195-A5-01 - \u003c\/strong\u003eGaslab Fixed Combustible Oxygen Detector\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePX2-1-2-I464-C-01 - \u003c\/strong\u003eGaslab Fixed Combustible Carbon Dioxide Detector\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePX2-1-2-P3400-A-01 - \u003c\/strong\u003eGaslab Fixed Combustible Methane Detector\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePX2-1-2-P3480-A-01 - \u003c\/strong\u003eGaslab Fixed Combustible Propane Detector\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eWarranty\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e1-year warranty - see \u003cstrong\u003e\u003ca title=\"View CO2Meter.com Terms and Conditions\" href=\"\/en-au\/pages\/terms-conditions\"\u003eCO2Meter Terms \u0026amp; Conditions\u003c\/a\u003e\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv class=\"specifications\"\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eGas Type:\u003c\/strong\u003e Hydrogen Sulfide\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRange ppm:\u003c\/strong\u003e 0-100ppm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAdmissible Range for Calibration Zero PPM:\u003c\/strong\u003e ± 10 % of measuring range\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAdmissible Range for Calibration Gain Test Gas:\u003c\/strong\u003e 30–120 % of test gas5\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTemperature Range: \u003c\/strong\u003e-30 to +50°C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStorage Temperature Range: \u003c\/strong\u003e0–20°C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHumidity Range: \u003c\/strong\u003e15-90 %RH\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePressure Range: \u003c\/strong\u003e80–120 kPa\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eReaction Time:\u003c\/strong\u003e ≤ 10 sec.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRun-in time2:\u003c\/strong\u003e 24 h\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFlow Rate:\u003c\/strong\u003e 500 ml\/min\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWarm-up Time:\u003c\/strong\u003e 300 Sec.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eResponse Time: \u003c\/strong\u003e≤ 200 Sec.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLife-time: \u003c\/strong\u003e\u0026gt;2 Years\u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"documents\"\u003e\n\u003ch3\u003eDocuments\u003c\/h3\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/PX2-1-2-E1197-B-01_Gaslab_Fixed_Combustible_Hydrogen_Sulfide_Detector_0-100ppm_H2S.pdf?v=1721240295\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/CO2METER_PDF.png?1094\" alt=\"Gaslab Fixed Combustible H2S Detector\"\u003e\u003c\/a\u003e\u003cspan\u003e\u003c\/span\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/PX2-1-2-E1197-B-01_Gaslab_Fixed_Combustible_Hydrogen_Sulfide_Detector_0-100ppm_H2S.pdf?v=1725040160\" title=\"Gaslab Fixed Combustible H2S Detector\"\u003e\u003cstrong\u003e\u003cspan style=\"color: #ff0000;\" color=\"#ff0000\"\u003eData Sheet (pdf)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca title=\"Manual Combustible Fixed Gas Detector - CO2Meter\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/MAN_GA_PX2_Ex_Tox_CO2Meter_1.pdf?v=1755545267\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/CO2METER_PDF.png?1094\" alt=\"Gaslab Fixed Combustible NH3 Detector\"\u003e\u003cstrong\u003e\u003cspan style=\"color: #ff0000;\" color=\"#ff0000\"\u003e Manual (pdf)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/MAN_GA_PX2_Ex_Tox_CO2Meter.pdf?v=1716564528\"\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e","brand":"CO2 Meter","offers":[{"title":"Default Title","offer_id":43963197653190,"sku":"PX2-1-2-E1197-B-01","price":1629.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/PX2-1-2-E1197-B-01-Combustible-H2S-Detector.jpg?v=1753283916"},{"product_id":"carbon-dioxide-co2-combustible-fixed-gas-detector","title":"Carbon Dioxide (CO2) Combustible Fixed Gas Detector (0-5000ppm)","description":"\u003cp\u003e\u003cspan style=\"color: #115e67;\"\u003e\u003cspan style=\"color: rgb(0, 0, 0);\"\u003eThe\u003c\/span\u003e\u003cstrong\u003e Carbon Dioxide (CO2) Combustible Fixed Gas Detector (PX2-1-2-I464-C-01)\u003c\/strong\u003e\u003c\/span\u003e is designed for continuous monitoring of CO2 gases between 0-5000ppm and vapors in hazardous areas of zones 1 and 2.\u003c\/p\u003e\n\u003cp\u003eThis detector is an explosion-proof \u003cspan\u003efixed CO2 gas detector, based with a 4-20 mA \/ RS485 Modbus output signal, alarm and fault relays (all SIL2 certified) for monitoring the ambient air to detect toxic gases.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThis solution is ideal for those industries that need protection amongst hazardous CO2 gases such as laboratories, garages, process rooms, combustion control rooms, refineries, gas stations, boiler rooms, confined spaces, and many others.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThis device is also commonly purchased for cryogenic facilities, nitrogen applications, industrial, factory, dry ice freezing and much more.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003eFeatures\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eModular industrial design, protection class IP66\u003c\/li\u003e\n\u003cli\u003eEx db: Ignition protection for zone 1 and 2\u003c\/li\u003e\n\u003cli\u003eEx nR: Ignition protection for zone 2\u003c\/li\u003e\n\u003cli\u003eFast and Precise CO2 Measurements 0-5000ppm\u003c\/li\u003e\n\u003cli\u003eCompatible across a broad range of BMS\u003c\/li\u003e\n\u003cli\u003eDevice can be used independent of control systems\u003c\/li\u003e\n\u003cli\u003eIndividual configuration options available\u003c\/li\u003e\n\u003cli\u003eRobust against dust, humidity, and high\/low temperatures\u003c\/li\u003e\n\u003cli\u003eSuitable for multiple industries and applications\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eCertifications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eATEX and IECEx certificates MSR-Electronic GmbH for electrical Ex protection\u003c\/li\u003e\n\u003cli\u003eSIL2 safety functions 4–20 mA, RS-485 and relay\u003c\/li\u003e\n\u003cli\u003ePX2-1 for zone 1 (and also suitable for zone 2):\u003c\/li\u003e\n\u003cli\u003eType “Ex db” protection flame-proof enclosure\u003c\/li\u003e\n\u003cli\u003ePX2-2 for zone 2\u003c\/li\u003e\n\u003cli\u003eType “Ex nR” protection\u003c\/li\u003e\n\u003cli\u003eEnclosure: Additional FM and CSA certificates for Class I, Div. 1\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eModels\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePX2-1-2-E1110-C-01 - \u003c\/strong\u003eGaslab Fixed Combustible Carbon Monoxide Detector\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePX2-1-2-E1130-E-01 - \u003c\/strong\u003eGaslab Fixed Combustible Nitrogen Dioxide Detector\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePX2-1-2-E1194-A-01 - \u003c\/strong\u003eGaslab Fixed Combustible Hydrogen Detector\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePX2-1-2-E1195-A5-01 - \u003c\/strong\u003eGaslab Fixed Combustible Oxygen Detector\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePX2-1-2-P3400-A-01 - \u003c\/strong\u003eGaslab Fixed Combustible Methane Detector\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePX2-1-2-P3480-A-01 - \u003c\/strong\u003eGaslab Fixed Combustible Propane Detector\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eWarranty\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e1-year warranty - see \u003ca href=\"\/en-au\/pages\/terms-conditions\" title=\"View CO2Meter.com Terms and Conditions\"\u003eCO2Meter Terms \u0026amp; Conditions.\u003c\/a\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv class=\"specifications\"\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eGas Type:\u003c\/strong\u003e Carbon Dioxide (CO2)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRange ppm:\u003c\/strong\u003e 0-5000ppm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAdmissible Range for Calibration Zero PPM:\u003c\/strong\u003e ±10 % of measuring range\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAdmissible Range for Calibration Gain Test Gas:\u003c\/strong\u003e 30–120% of test gas\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTemperature Range: \u003c\/strong\u003e-30 to +50°C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStorage Temperature Range: \u003c\/strong\u003e0–20°C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHumidity Range: \u003c\/strong\u003e15-90% RH\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePressure Range: \u003c\/strong\u003e80–120 kPa\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eReaction Time:\u003c\/strong\u003e ≤ 10 sec.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRun-in time2:\u003c\/strong\u003e 24 h\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFlow Rate:\u003c\/strong\u003e 500 ml\/min\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWarm-up Time:\u003c\/strong\u003e 300 Sec.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eResponse Time: \u003c\/strong\u003e≤ 200 Sec.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLife-time: \u003c\/strong\u003e\u0026gt;2 Years\u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"documents\"\u003e\n\u003ch3\u003eDocuments\u003c\/h3\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/PX2-1-2-I464-C-01_Gaslab_Fixed_Combustible_Carbon_Dioxide_Detector_0-2_CO2.pdf?v=1721394712\"\u003e\u003cimg alt=\"Gaslab Fixed Combustible CO2 Detector\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/CO2METER_PDF.png?1094\"\u003e\u003c\/a\u003e\u003cspan\u003e\u003c\/span\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/PX2-1-2-I464-C-01_Gaslab_Fixed_Combustible_Carbon_Dioxide_Detector_0-2_CO2.pdf?v=1725040228\" title=\"Gaslab Fixed Combustible CO2 Detector\"\u003e\u003cstrong\u003e\u003cspan color=\"#ff0000\" style=\"color: #ff0000;\"\u003eData Sheet (pdf)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/MAN_GA_PX2_Ex_Tox_CO2Meter_1.pdf?v=1755545267\" title=\"Manual Combustible Fixed Gas Detector - CO2Meter\"\u003e\u003cimg alt=\"Gaslab Fixed Combustible NH3 Detector\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/CO2METER_PDF.png?1094\"\u003e\u003cstrong\u003e\u003cspan color=\"#ff0000\" style=\"color: #ff0000;\"\u003e Manual (pdf)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/MAN_GA_PX2_Ex_Tox_CO2Meter.pdf?v=1716564528\"\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e","brand":"CO2 Meter","offers":[{"title":"PX2-1-2-I464-C-01: Carbon Dioxide (CO2) Combustible Fixed Gas Detector (0-5000ppm)","offer_id":43967417942214,"sku":"PX2-1-2-I464-C-01","price":2009.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/PX2-1-2-I464-C-01-Combustible-CO2-Detector.jpg?v=1753283915"},{"product_id":"methane-ch4-combustible-fixed-gas-detector","title":"Methane (CH4) Combustible Fixed Gas Detector (0-100% LEL)","description":"\u003cp\u003e\u003cspan style=\"color: #115e67;\"\u003e\u003cspan style=\"color: rgb(0, 0, 0);\"\u003eThe\u003c\/span\u003e\u003cstrong\u003e Methane (CH4) Combustible Fixed Gas Detector (PX2-1-2-P3400-A-01)\u003c\/strong\u003e\u003c\/span\u003e is designed for continuous monitoring of CH4 gases between 0-100% LEL and vapors in hazardous areas of zones 1 and 2.\u003c\/p\u003e\n\u003cp\u003eThis detector is an explosion-proof \u003cspan\u003efixed CH4 gas detector, based with a 4-20 mA \/ RS485 Modbus output signal, alarm and fault relays (all SIL2 certified) for monitoring the ambient air to detect toxic gases.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThis solution is ideal for those industries that need protection amongst hazardous CH4 gases such as occupational spaces, garages, process rooms, factories, combustion control rooms, refineries, gas stations, boiler rooms, and many others.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003eFeatures\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eModular industrial design, protection class IP66\u003c\/li\u003e\n\u003cli\u003eEx db: Ignition protection for zone 1 and 2\u003c\/li\u003e\n\u003cli\u003eEx nR: Ignition protection for zone 2\u003c\/li\u003e\n\u003cli\u003eFast and Precise CH4 Measurements 0-100% LEL\u003c\/li\u003e\n\u003cli\u003eCompatible across a broad range of BMS\u003c\/li\u003e\n\u003cli\u003eDevice can be used independent of control systems\u003c\/li\u003e\n\u003cli\u003eIndividual configuration options available\u003c\/li\u003e\n\u003cli\u003eRobust against dust, humidity, and high\/low temperatures\u003c\/li\u003e\n\u003cli\u003eSuitable for multiple industries and applications\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eCertifications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eATEX and IECEx certificates MSR-Electronic GmbH for electrical Ex protection\u003c\/li\u003e\n\u003cli\u003eSIL2 safety functions 4–20 mA, RS-485 and relay\u003c\/li\u003e\n\u003cli\u003ePX2-1 for zone 1 (and also suitable for zone 2):\u003c\/li\u003e\n\u003cli\u003eType “Ex db” protection flame-proof enclosure\u003c\/li\u003e\n\u003cli\u003ePX2-2 for zone 2\u003c\/li\u003e\n\u003cli\u003eType “Ex nR” protection\u003c\/li\u003e\n\u003cli\u003eEnclosure: Additional FM and CSA certificates for Class I, Div. 1\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eModels\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePX2-1-2-E1110-C-01 - \u003c\/strong\u003eGaslab Fixed Combustible Carbon Monoxide Detector\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePX2-1-2-E1130-E-01 - \u003c\/strong\u003eGaslab Fixed Combustible Nitrogen Dioxide Detector\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePX2-1-2-E1194-A-01 - \u003c\/strong\u003eGaslab Fixed Combustible Hydrogen Detector\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePX2-1-2-E1195-A5-01 - \u003c\/strong\u003eGaslab Fixed Combustible Oxygen Detector\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePX2-1-2-I464-C-01 - \u003c\/strong\u003eGaslab Fixed Combustible Carbon Dioxide Detector\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePX2-1-2-P3480-A-01 - \u003c\/strong\u003eGaslab Fixed Combustible Propane Detector\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eWarranty\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e1-year warranty - see \u003ca title=\"View CO2Meter.com Terms and Conditions\" href=\"\/en-au\/pages\/terms-conditions\"\u003eCO2Meter Terms \u0026amp; Conditions.\u003c\/a\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv class=\"specifications\"\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eGas Type:\u003c\/strong\u003e Methane (CH4)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRange ppm:\u003c\/strong\u003e 0-100% LEL\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAdmissible Range for Calibration Zero PPM:\u003c\/strong\u003e ±10 % of measuring range\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAdmissible Range for Calibration Gain Test Gas:\u003c\/strong\u003e 30–120% of test gas\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTemperature Range: \u003c\/strong\u003e-30 to +50°C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStorage Temperature Range: \u003c\/strong\u003e0–20°C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHumidity Range: \u003c\/strong\u003e15-90% RH\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePressure Range: \u003c\/strong\u003e80–120 kPa\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eReaction Time:\u003c\/strong\u003e ≤ 10 sec.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRun-in time2:\u003c\/strong\u003e 24 h\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFlow Rate:\u003c\/strong\u003e 500 ml\/min\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWarm-up Time:\u003c\/strong\u003e 300 Sec.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eResponse Time: \u003c\/strong\u003e≤ 200 Sec.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLife-time: \u003c\/strong\u003e\u0026gt;2 Years\u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"documents\"\u003e\n\u003ch3\u003eDocuments\u003c\/h3\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/PX2-1-2-P3400-A-01_Gaslab_Fixed_Combustible_Methane_Detector_0-100_LEL_CH4.pdf?v=1721395769\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/CO2METER_PDF.png?1094\" alt=\"Gaslab Fixed Combustible CH4 Detector\"\u003e\u003c\/a\u003e\u003cspan\u003e\u003c\/span\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/PX2-1-2-P3400-A-01_Gaslab_Fixed_Combustible_Methane_Detector_0-100_LEL_CH4.pdf?v=1725040661\" title=\"Gaslab Fixed Combustible CH4 Detector\"\u003e\u003cstrong\u003e\u003cspan style=\"color: #ff0000;\" color=\"#ff0000\"\u003eData Sheet (pdf)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca title=\"Manual Combustible Fixed Gas Detector - CO2Meter\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/MAN_GA_PX2_Ex_Tox_CO2Meter_1.pdf?v=1755545267\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/CO2METER_PDF.png?1094\" alt=\"Gaslab Fixed Combustible NH3 Detector\"\u003e\u003cstrong\u003e\u003cspan style=\"color: #ff0000;\" color=\"#ff0000\"\u003e Manual (pdf)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/MAN_GA_PX2_Ex_Tox_CO2Meter.pdf?v=1716564528\"\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e","brand":"CO2 Meter","offers":[{"title":"PX2-1-2-P3400-A-01: Methane (CH4) Combustible Fixed Gas Detector (0-100% LEL)","offer_id":43967419515078,"sku":"PX2-1-2-P3400-A-01","price":1329.0,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/PX2-1-2-P3400-A-01-Combustible-CH4-Detector.jpg?v=1753283914"},{"product_id":"propane-c3h8-combustible-fixed-gas-detector","title":"Propane (C3H8) Combustible Fixed Gas Detector (0-100% LEL)","description":"\u003cp\u003e\u003cspan style=\"color: #115e67;\"\u003e\u003cspan style=\"color: rgb(0, 0, 0);\"\u003eThe\u003c\/span\u003e\u003cstrong\u003e Propane (C3H8) Combustible Fixed Gas Detector (PX2-1-2-P3480-A-01)\u003c\/strong\u003e\u003c\/span\u003e is designed for continuous monitoring of C3H8 gases between 0-100% LEL and vapors in hazardous areas of zones 1 and 2.\u003c\/p\u003e\n\u003cp\u003eThis detector is an explosion-proof \u003cspan\u003efixed C3H8 gas detector, based with a 4-20 mA \/ RS485 Modbus output signal, alarm and fault relays (all SIL2 certified) for monitoring the ambient air to detect toxic gases.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThis solution is ideal for those industries that need protection amongst hazardous C3H8 gases such as occupational spaces, petrochemical, garages, process rooms, construction factories, oil rigs, manufacturing plants, and many others.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003eFeatures\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eModular industrial design, protection class IP66\u003c\/li\u003e\n\u003cli\u003eEx db: Ignition protection for zone 1 and 2\u003c\/li\u003e\n\u003cli\u003eEx nR: Ignition protection for zone 2\u003c\/li\u003e\n\u003cli\u003eFast and Precise C3H8 Measurements 0-100% LEL\u003c\/li\u003e\n\u003cli\u003eCompatible across a broad range of BMS\u003c\/li\u003e\n\u003cli\u003eDevice can be used independent of control systems\u003c\/li\u003e\n\u003cli\u003eIndividual configuration options available\u003c\/li\u003e\n\u003cli\u003eRobust against dust, humidity, and high\/low temperatures\u003c\/li\u003e\n\u003cli\u003eSuitable for multiple industries and applications\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eCertifications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eATEX and IECEx certificates MSR-Electronic GmbH for electrical Ex protection\u003c\/li\u003e\n\u003cli\u003eSIL2 safety functions 4–20 mA, RS-485 and relay\u003c\/li\u003e\n\u003cli\u003ePX2-1 for zone 1 (and also suitable for zone 2):\u003c\/li\u003e\n\u003cli\u003eType “Ex db” protection flame-proof enclosure\u003c\/li\u003e\n\u003cli\u003ePX2-2 for zone 2\u003c\/li\u003e\n\u003cli\u003eType “Ex nR” protection\u003c\/li\u003e\n\u003cli\u003eEnclosure: Additional FM and CSA certificates for Class I, Div. 1\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eModels\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePX2-1-2-E1110-C-01 - \u003c\/strong\u003eGaslab Fixed Combustible Carbon Monoxide Detector\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePX2-1-2-E1130-E-01 - \u003c\/strong\u003eGaslab Fixed Combustible Nitrogen Dioxide Detector\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePX2-1-2-E1194-A-01 - \u003c\/strong\u003eGaslab Fixed Combustible Hydrogen Detector\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePX2-1-2-E1195-A5-01 - \u003c\/strong\u003eGaslab Fixed Combustible Oxygen Detector\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePX2-1-2-I464-C-01 - \u003c\/strong\u003eGaslab Fixed Combustible Carbon Dioxide Detector\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePX2-1-2-P3400-A-01 - \u003c\/strong\u003eGaslab Fixed Combustible Methane Detector\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eWarranty\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e1-year warranty - see \u003ca title=\"View CO2Meter.com Terms and Conditions\" href=\"\/en-au\/pages\/terms-conditions\"\u003eCO2Meter Terms \u0026amp; Conditions.\u003c\/a\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv class=\"specifications\"\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eGas Type:\u003c\/strong\u003e Propane (C3H8)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRange ppm:\u003c\/strong\u003e 0-100% LEL\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAdmissible Range for Calibration Zero PPM:\u003c\/strong\u003e ±10 % of measuring range\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAdmissible Range for Calibration Gain Test Gas:\u003c\/strong\u003e 30–120% of test gas\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTemperature Range: \u003c\/strong\u003e-30 to +50°C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStorage Temperature Range: \u003c\/strong\u003e0–20°C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHumidity Range: \u003c\/strong\u003e15-90% RH\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePressure Range: \u003c\/strong\u003e80–120 kPa\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eReaction Time:\u003c\/strong\u003e ≤ 10 sec.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRun-in time2:\u003c\/strong\u003e 24 h\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFlow Rate:\u003c\/strong\u003e 500 ml\/min\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWarm-up Time:\u003c\/strong\u003e 300 Sec.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eResponse Time: \u003c\/strong\u003e≤ 200 Sec.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLife-time: \u003c\/strong\u003e\u0026gt;2 Years\u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"documents\"\u003e\n\u003ch3\u003eDocuments\u003c\/h3\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/PX2-1-2-P3480-A-01_Gaslab_Fixed_Combustible_Propane_Detector_0-100_LEL_C3H8.pdf?v=1721396643\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/CO2METER_PDF.png?1094\" alt=\"Gaslab Fixed Combustible C3H8 Detector\"\u003e\u003c\/a\u003e\u003cspan\u003e\u003c\/span\u003e\u003ca title=\"Gaslab Fixed Combustible C3H8 Detector\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/PX2-1-2-P3480-A-01_Gaslab_Fixed_Combustible_Propane_Detector_0-100_LEL_C3H8.pdf?v=1725040766\"\u003e\u003cstrong\u003e\u003cspan style=\"color: #ff0000;\" color=\"#ff0000\"\u003eData Sheet (pdf)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca title=\"Manual Combustible Fixed Gas Detector - CO2Meter\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/MAN_GA_PX2_Ex_Tox_CO2Meter_1.pdf?v=1755545267\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/CO2METER_PDF.png?1094\" alt=\"Gaslab Fixed Combustible NH3 Detector\"\u003e\u003cstrong\u003e\u003cspan style=\"color: #ff0000;\" color=\"#ff0000\"\u003e Manual (pdf)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/MAN_GA_PX2_Ex_Tox_CO2Meter.pdf?v=1716564528\"\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e","brand":"CO2 Meter","offers":[{"title":"PX2-1-2-P3480-A-01: Propane (C3H8) Combustible Fixed Gas Detector (0-100% LEL)","offer_id":43967428722886,"sku":"PX2-1-2-P3480-A-01","price":1329.0,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/PX2-1-2-P3480-A-01-Combustible-C3H8-Detector.jpg?v=1753283913"},{"product_id":"products-carbon-monoxide-co-fixed-gas-detection-system","title":"Carbon Monoxide (CO) Fixed Gas Detection System | Continuous CO Monitoring with Alarm System","description":"\u003cdiv style=\"text-align: left;\"\u003e\n\u003cp data-end=\"449\" data-start=\"313\" style=\"text-align: left;\"\u003e\u003cstrong\u003e⚠️ Detect Carbon Monoxide before it becomes a Threat.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-end=\"1542\" data-start=\"898\"\u003eThe \u003cspan style=\"color: rgb(17, 94, 103);\"\u003e\u003cstrong data-end=\"991\" data-start=\"902\"\u003eCarbon Monoxide (CO) Fixed Gas Detection System with Remote Sensor (MSC2 + CO Sensor)\u003c\/strong\u003e\u003c\/span\u003e is designed for continuous monitoring of carbon monoxide in commercial and industrial environments where personnel safety and early hazard detection are critical.\u003c\/p\u003e\n\u003cp data-end=\"1934\" data-start=\"1544\"\u003eCarbon monoxide is a toxic gas that can accumulate in enclosed or poorly ventilated areas without obvious warning. Fixed CO gas detection is essential in environments such as automotive facilities, mechanical rooms, loading zones, manufacturing spaces, food and beverage facilities, and research applications.\u003c\/p\u003e\n\u003cp data-end=\"2175\" data-start=\"1936\"\u003eThis fixed CO monitoring system uses a remote carbon monoxide gas sensor mounted near the hazard zone to help identify unsafe conditions quickly, activate alarms, and support a faster response before dangerous exposure levels escalate.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003ch2\u003eFeatures\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli data-end=\"347\" data-start=\"163\" data-section-id=\"1hn0x6k\"\u003e🔍 \u003cstrong data-end=\"214\" data-start=\"168\"\u003eContinuous Carbon Monoxide (CO) Monitoring\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"506\" data-start=\"349\" data-section-id=\"wt0qcq\"\u003e📡 \u003cstrong data-end=\"399\" data-start=\"354\"\u003eRemote CO Gas Sensor for Hazard Detection\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"648\" data-start=\"508\" data-section-id=\"o1p6mj\"\u003e🚨 \u003cstrong data-end=\"546\" data-start=\"513\"\u003eAudible \u0026amp; Visual Alarm System\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"822\" data-start=\"650\" data-section-id=\"14j37fe\"\u003e🔗 \u003cstrong data-end=\"706\" data-start=\"655\"\u003eBMS \u0026amp; Control System Integration (Modbus Ready)\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"993\" data-start=\"824\" data-section-id=\"xq31he\"\u003e⚙️ \u003cstrong data-end=\"882\" data-start=\"829\"\u003eConfigurable Relays for Automated Safety Response\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 data-end=\"340\" data-start=\"316\" data-section-id=\"8bgedh\"\u003e\u003cspan role=\"text\"\u003e📦 What’s Included?\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli data-end=\"534\" data-start=\"342\" data-section-id=\"o7eaji\"\u003eMSC2 Fixed Gas Detection Controller (Main Display Unit)\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"711\" data-start=\"536\" data-section-id=\"1d98puf\"\u003e(1) Remote Methane (CH4) Gas Sensor\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"871\" data-start=\"713\" data-section-id=\"v4fgr9\"\u003e(2) Audible \u0026amp; Visual Horn\/Strobe Alarms\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"1040\" data-start=\"873\" data-section-id=\"1su4yby\"\u003ePre-Configured Alarm Relays (3 Outputs)\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"1175\" data-start=\"1042\" data-section-id=\"1p90s8v\"\u003ePower Supply Compatibility (100–240 VAC \/ 24 VDC)\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"1305\" data-start=\"1177\" data-section-id=\"1tk51f0\"\u003eWall-Mount Hardware \u0026amp; Installation Kit\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"1422\" data-start=\"1307\" data-section-id=\"jsmk4n\"\u003eUser Manual \u0026amp; Quick Start Guide\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv class=\"specifications\"\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMeasurement Range:\u003c\/strong\u003e 0-50ppm\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eGas Type: \u003c\/b\u003eCarbon Monoxide\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHousing Type C\/E: \u003c\/strong\u003ePolycarbonate\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInstallation: \u003c\/strong\u003eWall Mounted\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eKnockouts for Cable Entry: \u003c\/strong\u003eStandard 6x M20\/25\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIngress Protection: \u003c\/strong\u003eIP65\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTemperature Range: \u003c\/strong\u003e-13°F to 140°F (-25°C to 60°C)\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStorage Temperature: \u003c\/strong\u003e-4°F to 149°F (-20°C to 65°C)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHumidity Range: \u003c\/strong\u003e15-95% RH non-condensing\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Supply:\u003c\/strong\u003e 100-240 VAC or 24VDC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Consumption: \u003c\/strong\u003e24 V DC | Max. 60 mA (1.5 VA), w\/ sensor, w\/o WAO\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAlarm Relay (3): \u003c\/strong\u003e5 A Dry Contact Configurable\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTransistor Output (2):\u003c\/strong\u003e 24 V DC\/0.1 A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAnalog Input (2\/3): \u003c\/strong\u003e4-20mA, overload and short-circuit proof, input resistance 130 proportional, overload and short-circuit proof, load ≤ 500 4–20 mA = measuring range\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAnalog Output Signal (1):\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003e2.4–\u0026lt; 4 mA = tolerable under range\u003c\/li\u003e\n\u003cli\u003e20–21.2 mA = tolerable over range \u003c\/li\u003e\n\u003cli\u003e≥ 21,2 mA= error over range\u003c\/li\u003e\n\u003cli\u003e≤ 2,0 mA = fault\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMSC2 Dimensions:\u003c\/strong\u003e 5.12 x 5.12 x 2.95 in. (130 x 130 x 75 mm)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMSC2 Weight:\u003c\/strong\u003e 1.32 lbs. (0.6 kg)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"specifications\"\u003e\n\u003ch3\u003eWarranty\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e1 year - See \u003cstrong\u003e\u003ca title=\"CO2Meter Terms and Conditions\" href=\"https:\/\/www.co2meter.com\/pages\/terms-conditions\"\u003eCO2Meter Terms and Conditions.\u003c\/a\u003e\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"documents\"\u003e\n\u003ch2\u003eDocuments\u003c\/h2\u003e\n\u003cdiv class=\"data-sheets\"\u003e\n\u003cp style=\"text-align: left;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/MSC2-CO-SYSTEM_-_Carbon_Monoxide_CO_Fixed_Gas_Safety_Detection_System.pdf?v=1775160905\" title=\"Gaslab Fixed Gas Detector Datasheet\" target=\"_blank\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/CO2METER_PDF.png?1093\" alt=\"Gaslab Fixed Gas Detector DataSheet\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/MSC2-CO-SYSTEM_-_Carbon_Monoxide_CO_Fixed_Gas_Safety_Detection_System.pdf?v=1775160905\" title=\"Gaslab Fixed Gas Detector Datasheet\" rel=\"noopener\" target=\"_blank\"\u003e\u003cstrong\u003e\u003cspan style=\"color: red;\"\u003eData Sheet (pdf) - MSC2 Detector\u003c\/span\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cdiv class=\"manuals\"\u003e\n\u003cp style=\"text-align: left;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/CO2METER_PDF.png?1093\" alt=\"Gaslab Fixed Ammonia Gas Detector\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/MAN_GA_MSC2_MSB2_CO2Meter-compressed_1.pdf?v=1755194606\"\u003e\u003cstrong\u003e\u003cspan style=\"color: red;\"\u003eManual\u003c\/span\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/MAN_GA_MSC2_MSB2_CO2Meter-compressed_1.pdf?v=1755194606\"\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"CO2Meter","offers":[{"title":"MSC2-CO-System: Carbon Monoxide (CO) Fixed Gas Detection System","offer_id":43987854000326,"sku":"MSC2-CO-System","price":2699.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/MSC2-Fixed-CO-System-Remote-2-Horn-Strobes.jpg?v=1775159977"},{"product_id":"co2-o2-nh3-fixed-gas-detection-system-laboratory","title":"CO2, O2 and NH3 Fixed Gas Safety System for Laboratories \u0026 Pharma | Multi-Gas Monitoring with Alarms","description":"\u003cp\u003e\u003cstrong\u003e🚨 Protect Laboratories \u0026amp; Pharma Facilities from CO2, O2 and Ammonia Hazards\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eMSC2-CO2-O2-NH3 System: CO2, O2, and NH3 Fixed Gas Detection System is an advanced multi-gas safety solution designed for continuous monitoring of carbon dioxide, oxygen and ammonia (NH3) in laboratory, pharmaceutical and research environments.\u003c\/p\u003e\n\u003cp data-start=\"536\" data-end=\"876\"\u003eLaboratories and pharma facilities often face multiple gas hazards simultaneously from CO2 buildup and oxygen displacement to toxic ammonia exposure.\u003c\/p\u003e\n\u003cp data-start=\"878\" data-end=\"1094\"\u003eBuilt on the MSC2 multi-gas safety platform, this system uses remote sensors to detect hazards at the source: triggering alarms, activating ventilation, and integrating with BMS systems for immediate response.\u003c\/p\u003e\n\u003ch2\u003eFeatures\u003c\/h2\u003e\n\u003cp\u003e•    Triple Gas Monitoring (CO2 + O2 + NH3)\u003cbr\u003e•    Remote Sensor Detection\u003cbr\u003e•    Designed for Labs \u0026amp; Pharma\u003cbr\u003e•    Audio\/Visual Alarms + Relays\u003cbr\u003e•    Multi-Gas Expandable Platform\u003cbr\u003e•    BMS \u0026amp; PLC Integration Ready\u003cbr\u003e•    Custom Configurations\u003cbr\u003e•    Flexible Power Options\u003cbr\u003e•    IP65 Rugged Enclosure\u003c\/p\u003e\n\u003ch2 data-end=\"1875\" data-start=\"1853\" data-section-id=\"101sl6h\"\u003e📦 What’s Included?\u003c\/h2\u003e\n\u003cul data-end=\"2265\" data-start=\"1877\"\u003e\n\u003cli data-end=\"1936\" data-start=\"1877\" data-section-id=\"438bkx\"\u003eMSC2 Fixed Gas Detection Controller (Main Display Unit)\u003c\/li\u003e\n\u003cli data-end=\"1966\" data-start=\"1937\" data-section-id=\"c0ypip\"\u003e(3) Remote Gas Sensors (CO2, O2, and NH3)\u003c\/li\u003e\n\u003cli data-end=\"2088\" data-start=\"2045\" data-section-id=\"zyx6sy\"\u003e(2) Audible \u0026amp; Visual Horn\/Strobe Alarms\u003c\/li\u003e\n\u003cli data-end=\"2132\" data-start=\"2089\" data-section-id=\"io3u1f\"\u003ePre-Configured Alarm Relays\u003c\/li\u003e\n\u003cli data-end=\"2186\" data-start=\"2133\" data-section-id=\"1hwy61f\"\u003ePower Supply Compatibility (100–240 VAC \/ 24 VDC)\u003c\/li\u003e\n\u003cli data-end=\"2229\" data-start=\"2187\" data-section-id=\"1kfu224\"\u003eWall-Mount Hardware \u0026amp; Installation Kit\u003c\/li\u003e\n\u003cli data-end=\"2265\" data-start=\"2230\" data-section-id=\"12t0ca\"\u003eUser Manual \u0026amp; Quick Start Guide\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv class=\"specifications\"\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cb\u003eGas Types: \u003c\/b\u003eCO2 (Carbon Dioxide), O2 (Oxygen), NH3 (Ammonia)\u003c\/li\u003e\n\u003cli data-end=\"2427\" data-start=\"2359\" data-section-id=\"ebfih5\"\u003e\n\u003cstrong data-end=\"2387\" data-start=\"2361\"\u003eCO2 Measurement Range:\u003c\/strong\u003e 0–5,000 ppm (custom ranges available)\u003c\/li\u003e\n\u003cli data-end=\"2467\" data-start=\"2428\" data-section-id=\"yl5m4e\"\u003e\n\u003cstrong data-end=\"2455\" data-start=\"2430\"\u003eO2 Measurement Range:\u003c\/strong\u003e 0–25% Vol\u003c\/li\u003e\n\u003cli data-end=\"2537\" data-start=\"2468\" data-section-id=\"r324fe\"\u003e\n\u003cstrong data-end=\"2496\" data-start=\"2470\"\u003eNH3 Measurement Range:\u003c\/strong\u003e 0–100 ppm (expandable up to 5,000 ppm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHousing Type C\/E: \u003c\/strong\u003ePolycarbonate\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInstallation: \u003c\/strong\u003eWall Mounted\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eKnockouts for Cable Entry: \u003c\/strong\u003eStandard 6x M20\/25\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIngress Protection: \u003c\/strong\u003eIP65\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTemperature Range: \u003c\/strong\u003e-13°F to 140°F (-25°C to 60°C)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHumidity Range: \u003c\/strong\u003e15-95% RH non-condensing\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Supply:\u003c\/strong\u003e 100-240 VAC or 24VDC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Consumption: \u003c\/strong\u003e24 V DC | Max. 60 mA (1.5 VA), w\/ sensor, w\/o WAO\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAlarm Relay (3): \u003c\/strong\u003e5 A Dry Contact Configurable\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTransistor Output (2):\u003c\/strong\u003e 24 V DC\/0.1 A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAnalog Input (2\/3): \u003c\/strong\u003e4-20mA compatible\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAnalog Output Signal (1): \u003c\/strong\u003eFault \u0026amp; range monitoring included\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eController Dimensions:\u003c\/strong\u003e 5.12 x 5.12 x 2.95 in. (130 x 130 x 75 mm)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eController Weight:\u003c\/strong\u003e 1.32 lbs. (0.6 kg)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"specifications\"\u003e\n\u003ch3\u003eWarranty\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e1 year - See \u003cstrong\u003e\u003ca href=\"https:\/\/www.co2meter.com\/pages\/terms-conditions\" title=\"CO2Meter Terms and Conditions\"\u003eCO2Meter Terms and Conditions.\u003c\/a\u003e\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"documents\"\u003e\n\u003cdiv class=\"data-sheets\"\u003e\n\u003ch2\u003eDocuments\u003c\/h2\u003e\n\u003cp style=\"text-align: left;\"\u003e\u003ca title=\"Gaslab Fixed Gas Detector Datasheet\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/DS-MSC2-CO2-O2-NH3-SYSTEM_-_Carbon_Dioxide_CO2_Oxygen_O2_Ammonia_NH3_Fixed_Gas_Safety_Detection_System.pdf\" target=\"_blank\"\u003e\u003cimg alt=\"Gaslab Fixed Gas Detector DataSheet\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/CO2METER_PDF.png?1093\"\u003e\u003c\/a\u003e\u003ca rel=\"noopener\" title=\"Gaslab Fixed Gas Detector Datasheet\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/DS-MSC2-CO2-O2-NH3-SYSTEM_-_Carbon_Dioxide_CO2_Oxygen_O2_Ammonia_NH3_Fixed_Gas_Safety_Detection_System.pdf\" target=\"_blank\"\u003e\u003cstrong\u003e\u003cspan style=\"color: red;\"\u003eData Sheet (pdf) - MSC2 Detector\u003c\/span\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cimg alt=\"Gaslab Fixed Ammonia Gas Detector\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/CO2METER_PDF.png?1093\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/MAN_GA_MSC2_MSB2_CO2Meter-compressed_1.pdf?v=1755194606\"\u003e\u003cstrong\u003e\u003cspan style=\"color: red;\"\u003eManual\u003c\/span\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/MAN_GA_MSC2_MSB2_CO2Meter-compressed_1.pdf?v=1755194606\"\u003e\u003c\/a\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"CO2Meter","offers":[{"title":"MSC2-CO2-O2-NH3-System: CO2, O2, \u0026 NH3 Fixed Gas Detection System for Laboratories \u0026 Pharma","offer_id":43987877265606,"sku":"MSC2-CO2-O2-NH3-System","price":4699.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/MSC2-Fixed-CO2-O2-NH3-System-3_Remote-2-Horn-Strobes.jpg?v=1775752398"},{"product_id":"co2-o2-fixed-gas-detection-system-grow-room-beverage","title":"CO2 \u0026 O2 Fixed Gas Detection System for Grow Rooms \u0026 Indoor Agriculture | Multi-Gas Monitoring with Alarms","description":"\u003cdiv style=\"text-align: left;\"\u003e🚨 Protect Grow Rooms \u0026amp; Cannabis Cultivation Facilities from CO2 Buildup and O2 Deficiency Risks\u003c\/div\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\n\u003cp data-start=\"319\" data-end=\"578\"\u003eThe \u003cstrong data-start=\"323\" data-end=\"383\"\u003eMSC2-CO2-O2 System: CO2 \u0026amp; O2 Fixed Gas Detection System\u003c\/strong\u003e is an advanced multi-gas safety solution designed for continuous monitoring of carbon dioxide (CO2) and oxygen (O2) in indoor agriculture, grow rooms, restaurants, and beverage environments.\u003c\/p\u003e\n\u003cp data-start=\"580\" data-end=\"923\"\u003eCO2 enrichment is widely used to optimize plant growth and carbonation systems, but elevated CO2 levels can lead to oxygen displacement. This system provides real-time monitoring, early hazard detection, and automated alarm response to protect personnel, maintain safe environments, and ensure compliance.\u003c\/p\u003e\n\u003cp data-start=\"925\" data-end=\"1156\"\u003eBuilt on the \u003cstrong data-start=\"938\" data-end=\"972\"\u003eMSC2 multi-gas safety platform\u003c\/strong\u003e, this system uses remote sensors to detect gas concentration changes at the source; triggering alarms, activating ventilation and integrating with facility systems for rapid response.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003ch2\u003eFeatures\u003c\/h2\u003e\n\u003cp\u003e•    Dual Gas Monitoring (CO2 + O2)\u003cbr\u003e•    Remote Sensor Detection\u003cbr\u003e•    Designed for Grow Rooms \u0026amp; Beverage Systems\u003cbr\u003e•    Audio\/Visual Alarms + Relays\u003cbr\u003e•    Multi-Gas Expandable Platform\u003cbr\u003e•    BMS \u0026amp; Controller Integration\u003cbr\u003e•    Custom Configurations\u003cbr\u003e•    Flexible Power Options\u003cbr\u003e•    IP65 Rugged Enclosure\u003c\/p\u003e\n\u003ch2 data-section-id=\"101sl6h\" data-start=\"1890\" data-end=\"1912\"\u003e📦 What’s Included?\u003c\/h2\u003e\n\u003cul data-start=\"1914\" data-end=\"2262\"\u003e\n\u003cli data-section-id=\"438bkx\" data-start=\"1914\" data-end=\"1973\"\u003eMSC2 Fixed Gas Detection Controller (Main Display Unit)\u003c\/li\u003e\n\u003cli data-section-id=\"c0ypip\" data-start=\"1974\" data-end=\"2003\"\u003e(2) Remote Gas Sensors (CO2 and O2)\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"zyx6sy\" data-start=\"2042\" data-end=\"2085\"\u003e(2) Audible \u0026amp; Visual Horn\/Strobe Alarms\u003c\/li\u003e\n\u003cli data-section-id=\"io3u1f\" data-start=\"2086\" data-end=\"2129\"\u003ePre-Configured Alarm Relays\u003c\/li\u003e\n\u003cli data-section-id=\"1hwy61f\" data-start=\"2130\" data-end=\"2183\"\u003ePower Supply Compatibility (100–240 VAC \/ 24 VDC)\u003c\/li\u003e\n\u003cli data-section-id=\"1kfu224\" data-start=\"2184\" data-end=\"2226\"\u003eWall-Mount Hardware \u0026amp; Installation Kit\u003c\/li\u003e\n\u003cli data-section-id=\"12t0ca\" data-start=\"2227\" data-end=\"2262\"\u003eUser Manual \u0026amp; Quick Start Guide\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv class=\"specifications\"\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cb\u003eGas Types: \u003c\/b\u003eCarbon Dioxide (CO2) + Oxygen (O2)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong data-start=\"2344\" data-end=\"2370\"\u003eCO2 Measurement Range:\u003c\/strong\u003e 0–5,000 ppm (higher ranges available)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eO₂ Measurement Range:\u003c\/strong\u003e 0–25% Vol\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHousing Type C\/E: \u003c\/strong\u003ePolycarbonate\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInstallation: \u003c\/strong\u003eWall Mounted\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eKnockouts for Cable Entry: \u003c\/strong\u003eStandard 6x M20\/25\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIngress Protection: \u003c\/strong\u003eIP65\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTemperature Range: \u003c\/strong\u003e-13°F to 140°F (-25°C to 60°C)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHumidity Range: \u003c\/strong\u003e15-95% RH non-condensing\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Supply:\u003c\/strong\u003e 100-240 VAC or 24VDC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Consumption: \u003c\/strong\u003e24 V DC | Max. 60 mA (1.5 VA), w\/ sensor, w\/o WAO\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAlarm Relay (3): \u003c\/strong\u003e5 A Dry Contact Configurable\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTransistor Output (2):\u003c\/strong\u003e 24 V DC\/0.1 A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAnalog Input (2\/3): \u003c\/strong\u003e4-20mA compatible\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAnalog Output Signal (1): \u003c\/strong\u003eFault \u0026amp; range monitoring included\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eController Dimensions:\u003c\/strong\u003e 5.12 x 5.12 x 2.95 in. (130 x 130 x 75 mm)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eController Weight:\u003c\/strong\u003e 1.32 lbs. (0.6 kg)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"specifications\"\u003e\n\u003ch3\u003eWarranty\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e1 year - See \u003cstrong\u003e\u003ca href=\"https:\/\/www.co2meter.com\/pages\/terms-conditions\" title=\"CO2Meter Terms and Conditions\"\u003eCO2Meter Terms and Conditions.\u003c\/a\u003e\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"documents\"\u003e\n\u003cdiv class=\"data-sheets\"\u003e\n\u003ch2\u003eDocuments\u003c\/h2\u003e\n\u003cp style=\"text-align: left;\"\u003e\u003ca title=\"Gaslab Fixed Gas Detector Datasheet\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/DS-MSC2-CO2-O2-SYSTEM_-_Carbon_Dioxide_CO2_Oxygen_O2_Fixed_Gas_Safety_Detection_System.pdf\" target=\"_blank\"\u003e\u003cimg alt=\"Gaslab Fixed Gas Detector DataSheet\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/CO2METER_PDF.png?1093\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/DS-MSC2-CO2-O2-SYSTEM_-_Carbon_Dioxide_CO2_Oxygen_O2_Fixed_Gas_Safety_Detection_System.pdf\" title=\"Fixed Gas Detector MSC2\" rel=\"noopener\" target=\"_blank\"\u003e\u003cstrong\u003e\u003cspan style=\"color: red;\"\u003eData Sheet (pdf) - MSC2 Detector\u003c\/span\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cimg alt=\"Gaslab Fixed Ammonia Gas Detector\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/CO2METER_PDF.png?1093\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/MAN_GA_MSC2_MSB2_CO2Meter-compressed_1.pdf?v=1755194606\"\u003e\u003cstrong\u003e\u003cspan style=\"color: red;\"\u003eManual\u003c\/span\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/MAN_GA_MSC2_MSB2_CO2Meter-compressed_1.pdf?v=1755194606\"\u003e\u003c\/a\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"accessories\"\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003c\/div\u003e","brand":"CO2Meter","offers":[{"title":"MSC2-CO2-O2-SYSTEM: CO2 \u0026 O2 Fixed Gas Detection System for Grow Rooms \u0026 Indoor Agriculture","offer_id":43987918684358,"sku":"MSC2-CO2-O2-SYSTEM","price":3999.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/MSC2-Fixed-CO2-O2-System-2_Remote-2-Horn-Strobes.jpg?v=1775753330"},{"product_id":"remote-door-entrance-module-for-gas-safety-alarms","title":"Remote Door Entrance Module for Gaslab Safety Alarms","description":"\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cspan style=\"color: rgb(17, 94, 103);\"\u003e\u003cstrong\u003eDEM-06-M: Remote Door Entrance Module for Gaslab Safety Alarm\u003c\/strong\u003e\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eis a cutting-edge solution designed to keep your facility safe and informed. Using advanced micro-technology, it provides\u003cspan\u003e \u003c\/span\u003ereal-time visualization of gas alarms\u003cspan\u003e \u003c\/span\u003eat every access point, ensuring that personnel are immediately aware of any potential danger before entering a hazardous room.\u003c\/p\u003e\n\u003cp\u003eWhether you're enhancing safety protocols or upgrading to smarter building controls, the \u003cstrong\u003eDEM-06 Series\u003c\/strong\u003e brings reliable, visible, and instant gas alarm information to where it matters most, the entrance.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eReal-Time Gas Alarm Visualization before Hazardous Entry\u003c\/li\u003e\n\u003cli\u003eSeamless Integration with Gaslab Industrial Fixed Safety Systems\u003c\/li\u003e\n\u003cli\u003eSupports Up to 128 Relay Signals\u003c\/li\u003e\n\u003cli\u003eLED Display for Quick Alarm Indicators\u003c\/li\u003e\n\u003cli\u003eUser-Friendly Interface with 5 Language Options\u003c\/li\u003e\n\u003cli\u003eFlexible Mounting Options between 5-6 ft.\u003c\/li\u003e\n\u003cli\u003eIP6S version\u003c\/li\u003e\n\u003cli\u003eCompliance with Industry Standards\u003c\/li\u003e\n\u003cli\u003eOptional: Integrated warning buzzer with reset function - internal\/external\u003c\/li\u003e\n\u003cli\u003eOptional: 2x open collector output for warning light or horn with reset function - internal\/external\u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv class=\"specifications\"\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMeasurement Range:\u003c\/strong\u003e Dependent upon sensor selected\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eGas Type: \u003c\/b\u003eDependent upon sensor selected\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHousing Type C\/E: \u003c\/strong\u003ePolycarbonate\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInstallation: \u003c\/strong\u003eWall Mounted\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDisplay: \u003c\/strong\u003e2 lines 16 characters each\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStatus LED (3): \u003c\/strong\u003eNormal operation-fault-alarm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperation: \u003c\/strong\u003e6 push-buttons - menu-driven\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTransceiver: \u003c\/strong\u003eRS-485\/19200 Baud\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIngress Protection: \u003c\/strong\u003eIP65\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTemperature Range: \u003c\/strong\u003e4°F to 122°F\u003cstrong\u003e \u003c\/strong\u003e(-10°C to 50 °C)\u003cstrong\u003e\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHumidity Range: \u003c\/strong\u003e15–90 % RH not-condensing\u003cstrong\u003e \u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStorage Temperature: \u003c\/strong\u003e-4°F to 149°F (-20°C to 65°C)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStorage Temperature Range:\u003c\/strong\u003e -4°F to 149°F (-20°C to 65°C)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eElectrical\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Supply: \u003c\/strong\u003e18-28 V DC, reverse polarity protected\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Consumption w\/o options: \u003c\/strong\u003e40 mA. max. (1.0 VA)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFlammability Classification: \u003c\/strong\u003eUL 94 V2\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCable Entry:\u003c\/strong\u003e Standard 1 x M20\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection: \u003c\/strong\u003eScrew-type terminals, 0.25-2.5 mm2\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eDimensions Type A: \u003c\/b\u003e3.7 x 5.12 x 2.24 in \u003cb\u003e(\u003c\/b\u003e94 x 130 x 57 mm)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDimensions Type B: \u003c\/strong\u003e5.12 x 5.12 x 2.95 in (130 x 130 x 75 mm)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e 1.32 lbs. (0.6 kg)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"specifications\"\u003e\n\u003ch3\u003eWarranty\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e1 year - See \u003ca href=\"https:\/\/www.co2meter.com\/pages\/terms-conditions\" title=\"CO2Meter Terms and Conditions\"\u003eCO2Meter Terms and Conditions\u003c\/a\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"documents\"\u003e\n\u003cdiv class=\"data-sheets\"\u003e\n\u003cp style=\"text-align: left;\"\u003e\u003ca title=\"DEM 06 Door Module for Gaslab Safety Alarms Datasheet\" target=\"_blank\"\u003e\u003c\/a\u003e\u003cmeta charset=\"utf-8\"\u003e\u003cstrong\u003e\u003ca title=\"Remote Sensor for Gaslab Multi Gas Detector\" target=\"_blank\"\u003e\u003cimg alt=\"Remote Sensor Datasheet\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/CO2METER_PDF.png?1093\"\u003e\u003c\/a\u003e\u003ca rel=\"noopener\" title=\"DEM 06 Door Module for Gaslab Safety Alarms Datasheet\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/DS-DEM-06.pdf?v=1747944767\" target=\"_blank\"\u003e\u003cspan style=\"color: red;\"\u003eData Sheet (pdf)\u003c\/span\u003e\u003c\/a\u003e\u003ca title=\"DEM 06 Door Module for Gaslab Safety Alarms Datasheet\" target=\"_blank\"\u003e\u003c\/a\u003e\u003c\/strong\u003e\u003cstrong\u003e\u003ca title=\"DEM 06 Door Module for Gaslab Safety Alarms Datasheet\" target=\"_blank\"\u003e\u003c\/a\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"manuals\"\u003e\n\u003cp style=\"text-align: left;\"\u003e\u003cimg alt=\"DEM 06 Door Module for Gaslab Safety Alarms Manual\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/CO2METER_PDF.png?1093\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/GA_DEM_E.pdf_-_MSR-Electronic_Documentation-compressed_1.pdf?v=1755186702\"\u003e\u003cstrong\u003e\u003cspan style=\"color: red;\"\u003eManual\u003c\/span\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/GA_DEM_E.pdf_-_MSR-Electronic_Documentation-compressed_1.pdf?v=1755186702\"\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"accessories\"\u003e\n\u003ch3\u003eCompatible With: \u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.co2meter.com\/products\/fixed-multi-gas-detector\" title=\"MSC2 Gaslab Fixed Industrial Multi-Gas Detector\"\u003eMSC2 Series: Gaslab Fixed Industrial Multi-Gas System\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.co2meter.com\/products\/digital-multi-gas-controller-system\" title=\"Gaslab DGC-06 Digital Gas Controller System\"\u003eDGC-06: Gaslab Digital Gas Controller System\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.co2meter.com\/collections\/combustible-fixed-gas-detectors\" title=\"Gaslab Fixed Combustible Gas Detectors\"\u003ePX-2: Gaslab Combustible Gas Safety Systems\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e","brand":"CO2Meter","offers":[{"title":"DEM-06-M: Gaslab Digital Gas Controller Additional System Monitor for MSC2","offer_id":45702167003334,"sku":"DEM-06-M","price":999.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/DEM-06-M_Door_Entrance_Module-Master-Co2Meter.jpg?v=1775756749"},{"product_id":"fixed-multi-gas-detector-horn-strobe","title":"Multi-Gas Fixed Safety System Alarm Horn Strobe (Amber Lens)","description":"\u003cp\u003eThe \u003cspan style=\"color: #115e67;\"\u003e\u003cstrong\u003eFixed Multi-Gas Detector Alarm Safety Horn Strobe (Amber Lens)\u003c\/strong\u003e\u003c\/span\u003e is designed to provide an instant audible and visual indication of a potential gas leak in large or noisy areas to meet code compliance and protect against gas leaks.\u003c\/p\u003e\n\u003cp\u003eThis alarm safety strobe is compatible only with the corresponding \u003ca title=\"Fixed Multi Gas Industrial Detector\" href=\"\/en-au\/products\/fixed-multi-gas-detector\"\u003eFixed Multi-Gas Detector Series (MSC2)\u003c\/a\u003e \u003ca href=\"https:\/\/www.co2meter.com\/collections\/industrial-multi-gas-fixed-controllers-detectors\/products\/digital-multi-gas-controller-system\" title=\"Digital Multi-Gas Controller\"\u003eDigital Multi-Gas Controller (DGC-06)\u003c\/a\u003e, or the \u003ca title=\"Combustible Fixed Gas Detectors\" href=\"\/en-au\/collections\/combustible-fixed-gas-detectors\"\u003eCombustible Fixed Gas Detector Series (PX2)\u003c\/a\u003e.\u003c\/p\u003e\n\u003ch2\u003eFeatures\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cspan\u003eBase amber, flashing light \u003c\/span\u003e\u003cspan\u003e98dB alerts\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e24 VDC\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eProtection class: IP65\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eTemperature range: -40°C to +55°C\u003cbr\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003eEasy and clean install, no additional wiring is required\u003c\/li\u003e\n\u003cli\u003eMeets code compliance for OSHA, NFPA, NBIC, and CGA \u003c\/li\u003e\n\u003cli\u003eInstant strobe alarm indication when AL 1,2, or 3 is triggered\u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eWorks with\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca title=\"Fixed Multi Gas Industrial Detector\" href=\"\/en-au\/products\/fixed-multi-gas-detector\"\u003eFixed Multi-Gas Detector Series (MSC2)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.co2meter.com\/collections\/industrial-multi-gas-fixed-controllers-detectors\/products\/digital-multi-gas-controller-system\" title=\"Digital Multi-Gas Controller\"\u003eDigital Multi-Gas Controller (DGC-06)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\n\u003ca title=\"Combustible Fixed Gas Detectors\" href=\"\/en-au\/collections\/combustible-fixed-gas-detectors\"\u003eCombustible Fixed Gas Detector Series (PX2)\u003c\/a\u003e.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eModels\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cspan\u003e\u003cstrong\u003e\u003cspan data-teams=\"true\"\u003eMSC2-HS-Amber: \u003c\/span\u003eWhite\/Amber -\u003c\/strong\u003e Includes 1 horn strobe, 10 ft. Ethernet cable, 1 safety amber lens \u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan\u003e\u003cstrong\u003eMSC2-HS-Clear: White\/Clear \u003c\/strong\u003e- Includes 1 horn strobe, 10 ft. Ethernet cable, 1 safety clear lens\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv class=\"specifications\"\u003e\n\u003ch2\u003eSpecifications:\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Supply:\u003c\/strong\u003e 10-60 VDC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Consumption: \u003c\/strong\u003eMax. 35 mA at 24 VDC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHumidity:\u003c\/strong\u003e 15-95% RH non-condensing\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWorking Temperature: \u003c\/strong\u003e-13°F to -158°F (-25°C to 70°C)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePressure Range: \u003c\/strong\u003eAtmospheric ±10 %\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnclosure:\u003c\/strong\u003e Material Base ABS, lens PC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProtection Class:\u003c\/strong\u003e IP54\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e Fixed\/Wall Mount Installation\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCable Entry Ca.:\u003c\/strong\u003e 12mm diameter\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWire Connection: \u003c\/strong\u003eScrew-type terminals, min. 0.28 mm2, max. 2.5 mm2\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower: \u003c\/strong\u003esupplied by POE Ethernet cable (included)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight: \u003c\/strong\u003e0.33 lbs.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDimensions:\u003c\/strong\u003e 3.66 x 3.66 in\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eWarranty\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e1 year - See \u003cstrong\u003e\u003ca title=\"See CO2Meter Terms and Conditions\" href=\"https:\/\/www.co2meter.com\/pages\/terms-conditions\"\u003eCO2Meter Terms and Conditions\u003c\/a\u003e\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"documents\"\u003e\n\u003ch3\u003eDocuments\u003c\/h3\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/Data_Sheet_WH_CL_White-Amber_CO2Meter_2025Y.pdf?v=1753195432\" title=\"CO2 Storage Safety 3 Alarm Amber Horn Strobe Datasheet\"\u003e\u003cimg alt=\"Remote CO2 Storage Safety 3 Alarm\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/CO2METER_PDF.png?1093\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/Data_Sheet_MSC2-HS2Multi-Gas_Fixed_Safety_System_Alarm_Horn_Strobe_CO2Meter.pdf?v=1775478549\" title=\"Multi-Gas Fixed Safety System Alarm Horn Strobe Datasheet\"\u003e\u003cstrong\u003eData Sheet: Fixed Multi-Gas Detector Horn Strobe \u003c\/strong\u003e\u003c\/a\u003e \u003cstrong\u003e(pdf)\u003c\/strong\u003e\u003ca title=\"CO2 Storage Safety 3 Alarm Strobe Lights Datasheet\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/Data_Sheet_WH_CL_White-Amber_CO2Meter_2025Y.pdf?v=1753195432\"\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e","brand":"CO2Meter","offers":[{"title":"MSC2-HS-Amber - Fixed Multi Gas Detector Horn Strobe (Amber)","offer_id":44773288214726,"sku":"WH\/AM-White\/Amber","price":419.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/MSC2-HS2-AMB-industrialhornstrobe-co2meter.jpg?v=1775479574"},{"product_id":"methane-ch4-fixed-gas-detection-system","title":"Methane (CH4) Fixed Gas Detection System | Flammable Gas Detector with Remote Sensor \u0026 Alarms","description":"\u003cdiv style=\"text-align: left;\"\u003e\n\u003cp data-start=\"2286\" data-end=\"2636\"\u003e🚨 Protect Your Lab from Invisible Gas Hazards Before They Become Violations\u003c\/p\u003e\n\u003cp data-start=\"2286\" data-end=\"2636\"\u003eThe \u003cspan style=\"color: rgb(17, 94, 103);\"\u003e\u003cstrong data-start=\"2290\" data-end=\"2360\"\u003eMethane (CH4) Fixed Gas Detection System with Remote Sensor (MSC2)\u003c\/strong\u003e\u003c\/span\u003e is an industrial-grade flammable gas detector designed for continuous methane leak monitoring in high-risk environments.\u003c\/p\u003e\n\u003cp data-start=\"2286\" data-end=\"2636\"\u003eThis system combines advanced gas sensor technology with real-time gas detection to protect personnel and facilities from combustible gas hazards.\u003c\/p\u003e\n\u003cp data-start=\"2638\" data-end=\"2888\"\u003eBuilt for industrial applications, this fixed gas monitoring system uses a \u003cstrong\u003eremote gas detection sensor\u003c\/strong\u003e to identify methane leaks at the source, enabling fast response, alarm activation, and system integration with ventilation or shutdown controls.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003ch2\u003eFeatures\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli data-section-id=\"q6gxft\" data-start=\"1493\" data-end=\"1639\"\u003e\n\u003cstrong data-start=\"1495\" data-end=\"1549\"\u003eContinuous Methane Leak Detection (CH4 Monitoring)\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"shdb2x\" data-start=\"1641\" data-end=\"1779\"\u003e\n\u003cstrong data-start=\"1643\" data-end=\"1686\"\u003eRemote Sensor for Hazard-Zone Detection\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1ttuyh2\" data-start=\"1781\" data-end=\"1926\"\u003e\n\u003cstrong data-start=\"1783\" data-end=\"1830\"\u003eIndustrial-Grade Fixed Gas Detection System\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1xhgjtv\" data-start=\"1928\" data-end=\"2096\"\u003e\n\u003cstrong data-start=\"1930\" data-end=\"1983\"\u003eConfigurable Alarm System (Audio\/Visual + Relays)\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"zubizz\" data-start=\"2098\" data-end=\"2226\"\u003e\n\u003cstrong data-start=\"2100\" data-end=\"2149\"\u003eFlexible Multi-Gas Platform (MSC2 Controller)\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"g2qp4j\" data-start=\"2228\" data-end=\"2358\"\u003e\n\u003cstrong data-start=\"2230\" data-end=\"2279\"\u003eBMS \u0026amp; PLC Integration Ready (Modbus \/ DGC-06)\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1ggemw9\" data-start=\"2360\" data-end=\"2484\"\u003e\n\u003cstrong data-start=\"2362\" data-end=\"2405\"\u003eReliable Power Options for Any Facility\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"opqemp\" data-start=\"2486\" data-end=\"2603\"\u003e\n\u003cstrong data-start=\"2488\" data-end=\"2532\"\u003eRugged IP65 Enclosure for Industrial Use\u003c\/strong\u003e\u003cstrong data-start=\"2488\" data-end=\"2532\"\u003e\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 data-end=\"340\" data-start=\"316\" data-section-id=\"8bgedh\"\u003e\u003cspan role=\"text\"\u003e📦 What’s Included?\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli data-end=\"534\" data-start=\"342\" data-section-id=\"o7eaji\"\u003eMSC2 Fixed Gas Detection Controller (Main Display Unit)\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"711\" data-start=\"536\" data-section-id=\"1d98puf\"\u003e(1) Remote Methane (CH4) Gas Sensor\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"871\" data-start=\"713\" data-section-id=\"v4fgr9\"\u003e(2) Audible \u0026amp; Visual Horn\/Strobe Alarms\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"1040\" data-start=\"873\" data-section-id=\"1su4yby\"\u003ePre-Configured Alarm Relays (3 Outputs)\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"1175\" data-start=\"1042\" data-section-id=\"1p90s8v\"\u003ePower Supply Compatibility (100–240 VAC \/ 24 VDC)\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"1305\" data-start=\"1177\" data-section-id=\"1tk51f0\"\u003eWall-Mount Hardware \u0026amp; Installation Kit\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"1422\" data-start=\"1307\" data-section-id=\"jsmk4n\"\u003eUser Manual \u0026amp; Quick Start Guide\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv class=\"specifications\"\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMeasurement Range:\u003c\/strong\u003e 0–100% LEL\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eGas Type: \u003c\/b\u003eMethane (CH4)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHousing Type C\/E: \u003c\/strong\u003ePolycarbonate\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInstallation: \u003c\/strong\u003eWall Mounted\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eKnockouts for Cable Entry: \u003c\/strong\u003eStandard 6x M20\/25\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIngress Protection: \u003c\/strong\u003eIP65\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTemperature Range: \u003c\/strong\u003e-13°F to 140°F (-25°C to 60°C)\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHumidity Range: \u003c\/strong\u003e15-95% RH non-condensing\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStorage Temperature: \u003c\/strong\u003e-4°F to 149°F (-20°C to 65°C)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Supply:\u003c\/strong\u003e 100-240 VAC or 24VDC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Consumption: \u003c\/strong\u003e24 VDC | Max. 60 mA (1.5 VA), w\/ sensor, w\/o WAO\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAlarm Relay (3): \u003c\/strong\u003e5 A Dry Contact Configurable\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTransistor Output (2):\u003c\/strong\u003e 24 V DC\/0.1 A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAnalog Input (2\/3): \u003c\/strong\u003e4-20mA, overload and short-circuit proof, input resistance 130 proportional, overload and short-circuit proof, load ≤ 500 4–20 mA = measuring range\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAnalog Output Signal (1):\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003e2.4–\u0026lt; 4 mA = tolerable under range\u003c\/li\u003e\n\u003cli\u003e20–21.2 mA = tolerable over range \u003c\/li\u003e\n\u003cli\u003e≥ 21,2 mA= error over range\u003c\/li\u003e\n\u003cli\u003e≤ 2,0 mA = fault\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eController Dimensions:\u003c\/strong\u003e 5.12 x 5.12 x 2.95 in. (130 x 130 x 75 mm)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eController Weight:\u003c\/strong\u003e 1.32 lbs. (0.6 kg)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 style=\"text-align: center;\"\u003eComparison Chart\u003c\/h3\u003e\n\u003ctable data-start=\"4817\" data-end=\"5051\" class=\"w-fit min-w-(--thread-content-width)\" style=\"width: 100%; height: 97.969px;\"\u003e\n\u003cthead data-start=\"4817\" data-end=\"4853\"\u003e\n\u003ctr data-start=\"4817\" data-end=\"4853\" style=\"height: 19.5938px;\"\u003e\n\u003cth data-start=\"4817\" data-end=\"4827\" data-col-size=\"sm\" class=\"\" style=\"width: 48.0914%; height: 19.5938px;\"\u003eFeature\u003c\/th\u003e\n\u003cth data-start=\"4827\" data-end=\"4838\" data-col-size=\"sm\" class=\"\" style=\"width: 19.7266%; height: 19.5938px;\"\u003eCO2Meter\u003c\/th\u003e\n\u003cth data-start=\"4838\" data-end=\"4853\" data-col-size=\"sm\" class=\"\" style=\"width: 28.2534%; height: 19.5938px;\"\u003eOthers\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody data-start=\"4890\" data-end=\"5051\"\u003e\n\u003ctr data-start=\"4890\" data-end=\"4929\" style=\"height: 19.5938px;\"\u003e\n\u003ctd data-start=\"4890\" data-end=\"4914\" data-col-size=\"sm\" style=\"width: 48.0914%; height: 19.5938px;\"\u003e\u003cstrong\u003eCustom Configurations\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"4914\" data-end=\"4918\" data-col-size=\"sm\" style=\"width: 19.7266%; height: 19.5938px;\"\u003e✅\u003c\/td\u003e\n\u003ctd data-start=\"4918\" data-end=\"4929\" data-col-size=\"sm\" style=\"width: 28.2534%; height: 19.5938px;\"\u003eLimited\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"4930\" data-end=\"4978\" style=\"height: 19.5938px;\"\u003e\n\u003ctd data-start=\"4930\" data-end=\"4954\" data-col-size=\"sm\" style=\"width: 48.0914%; height: 19.5938px;\"\u003e\u003cstrong\u003eDirect Expert Support\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"4954\" data-end=\"4958\" data-col-size=\"sm\" style=\"width: 19.7266%; height: 19.5938px;\"\u003e✅\u003c\/td\u003e\n\u003ctd data-start=\"4958\" data-end=\"4978\" data-col-size=\"sm\" style=\"width: 28.2534%; height: 19.5938px;\"\u003eDistributor only\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"4979\" data-end=\"5021\" style=\"height: 19.5938px;\"\u003e\n\u003ctd data-start=\"4979\" data-end=\"5006\" data-col-size=\"sm\" style=\"width: 48.0914%; height: 19.5938px;\"\u003e\u003cstrong\u003eTurnkey Compliance Focus\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"5006\" data-end=\"5010\" data-col-size=\"sm\" style=\"width: 19.7266%; height: 19.5938px;\"\u003e✅\u003c\/td\u003e\n\u003ctd data-start=\"5010\" data-end=\"5021\" data-col-size=\"sm\" style=\"width: 28.2534%; height: 19.5938px;\"\u003ePartial\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"5022\" data-end=\"5051\" style=\"height: 19.5938px;\"\u003e\n\u003ctd data-start=\"5022\" data-end=\"5042\" data-col-size=\"sm\" style=\"width: 48.0914%; height: 19.5938px;\"\u003e\u003cstrong\u003eModular Multi-Gas\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"5042\" data-end=\"5046\" data-col-size=\"sm\" style=\"width: 19.7266%; height: 19.5938px;\"\u003e✅\u003c\/td\u003e\n\u003ctd data-start=\"5046\" data-end=\"5051\" data-col-size=\"sm\" style=\"width: 28.2534%; height: 19.5938px;\"\u003e✅\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"specifications\"\u003e\n\u003ch3\u003e\u003cbr\u003e\u003c\/h3\u003e\n\u003ch3\u003eWarranty\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e1 year - See \u003cstrong\u003e\u003ca href=\"https:\/\/www.co2meter.com\/pages\/terms-conditions\" title=\"CO2Meter Terms and Conditions\"\u003eCO2Meter Terms and Conditions.\u003c\/a\u003e\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003ch2\u003eDocuments\u003c\/h2\u003e\n\u003cdiv class=\"documents\"\u003e\n\u003cdiv class=\"data-sheets\"\u003e\n\u003cp style=\"text-align: left;\"\u003e\u003ca title=\"Gaslab Fixed Gas Detector Datasheet\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/MSC2-CH4-SYSTEM_Methane_CH4_Fixed_Gas_Safety_Detection_System_01.pdf?v=1775066103\" target=\"_blank\"\u003e\u003cimg alt=\"Gaslab Fixed Gas Detector DataSheet\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/CO2METER_PDF.png?1093\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/MSC2-CH4-SYSTEM_Methane_CH4_Fixed_Gas_Safety_Detection_System_01.pdf?v=1775066103\" title=\"Gaslab Fixed Gas Detector Datasheet\" rel=\"noopener\" target=\"_blank\"\u003e\u003cstrong\u003e\u003cspan style=\"color: red;\"\u003eData Sheet (pdf) - MSC2 Detector\u003c\/span\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cimg alt=\"Gaslab Fixed Ammonia Gas Detector\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/CO2METER_PDF.png?1093\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/MAN_GA_MSC2_MSB2_CO2Meter-compressed_1.pdf?v=1755194606\"\u003e\u003cstrong\u003e\u003cspan style=\"color: red;\"\u003eManual\u003c\/span\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/MAN_GA_MSC2_MSB2_CO2Meter-compressed_1.pdf?v=1755194606\"\u003e\u003c\/a\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"CO2Meter","offers":[{"title":"MSC2-CH4-System: Methane (CH4) Fixed Gas Detection System | Flammable Gas Detector with Remote Sensor \u0026 Alarms","offer_id":45670004228294,"sku":"MSC2-CH4-System","price":3099.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/MSC2-CH4-System-Fixed-CH4-System-Remote-2-Horn-Strobes.jpg?v=1775062520"},{"product_id":"multi-gas-fixed-safety-system-alarm-horn-strobe-clear-lens","title":"Multi-Gas Fixed Safety System Alarm Horn Strobe (Clear Lens)","description":"\u003cp\u003eThe \u003cspan style=\"color: #115e67;\"\u003e\u003cstrong\u003eFixed Multi-Gas Detector Alarm Safety Horn Strobe (Clear Lens)\u003c\/strong\u003e\u003c\/span\u003e is designed to provide an instant audible and visual indication of a potential gas leak in large or noisy areas to meet code compliance and protect against gas leaks.\u003c\/p\u003e\n\u003cp\u003eThis alarm safety strobe is compatible only with the corresponding \u003ca title=\"Fixed Multi Gas Industrial Detector\" href=\"\/en-au\/products\/fixed-multi-gas-detector\"\u003eFixed Multi-Gas Detector Series (MSC2)\u003c\/a\u003e \u003ca href=\"https:\/\/www.co2meter.com\/collections\/industrial-multi-gas-fixed-controllers-detectors\/products\/digital-multi-gas-controller-system\" title=\"Digital Multi-Gas Controller\"\u003eDigital Multi-Gas Controller (DGC-06)\u003c\/a\u003e, or the \u003ca title=\"Combustible Fixed Gas Detectors\" href=\"\/en-au\/collections\/combustible-fixed-gas-detectors\"\u003eCombustible Fixed Gas Detector Series (PX2)\u003c\/a\u003e.\u003c\/p\u003e\n\u003ch2\u003eFeatures\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cspan\u003eBase clear, flashing light \u003c\/span\u003e\u003cspan\u003e98dB alerts\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e24 VDC\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eProtection class: IP65\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eTemperature range: -40°C to +55°C\u003cbr\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003eEasy and clean install, no additional wiring is required\u003c\/li\u003e\n\u003cli\u003eMeets code compliance for OSHA, NFPA, NBIC, and CGA \u003c\/li\u003e\n\u003cli\u003eInstant strobe alarm indication when AL 1,2, or 3 is triggered\u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eWorks with\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca title=\"Fixed Multi Gas Industrial Detector\" href=\"\/en-au\/products\/fixed-multi-gas-detector\"\u003eFixed Multi-Gas Detector Series (MSC2)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.co2meter.com\/collections\/industrial-multi-gas-fixed-controllers-detectors\/products\/digital-multi-gas-controller-system\" title=\"Digital Multi-Gas Controller\"\u003eDigital Multi-Gas Controller (DGC-06)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\n\u003ca title=\"Combustible Fixed Gas Detectors\" href=\"\/en-au\/collections\/combustible-fixed-gas-detectors\"\u003eCombustible Fixed Gas Detector Series (PX2)\u003c\/a\u003e.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eModels\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cspan\u003e\u003cstrong\u003e\u003cspan data-teams=\"true\"\u003eMSC2-HS-Amber: \u003c\/span\u003eWhite\/Amber -\u003c\/strong\u003e Includes 1 horn strobe, 10 ft. Ethernet cable, 1 safety amber lens \u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan\u003e\u003cstrong\u003eMSC2-HS-Clear: White\/Clear \u003c\/strong\u003e- Includes 1 horn strobe, 10 ft. Ethernet cable, 1 safety clear lens\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv class=\"specifications\"\u003e\n\u003ch2\u003eSpecifications:\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Supply:\u003c\/strong\u003e 10-60 VDC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Consumption: \u003c\/strong\u003eMax. 35 mA at 24 VDC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHumidity:\u003c\/strong\u003e 15-95% RH non-condensing\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWorking Temperature: \u003c\/strong\u003e-13°F to -158°F (-25°C to 70°C)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePressure Range: \u003c\/strong\u003eAtmospheric ±10 %\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnclosure:\u003c\/strong\u003e Material Base ABS, lens PC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProtection Class:\u003c\/strong\u003e IP54\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e Fixed\/Wall Mount Installation\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCable Entry Ca.:\u003c\/strong\u003e 12mm diameter\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWire Connection: \u003c\/strong\u003eScrew-type terminals, min. 0.28 mm2, max. 2.5 mm2\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower: \u003c\/strong\u003esupplied by POE Ethernet cable (included)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight: \u003c\/strong\u003e0.33 lbs.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDimensions:\u003c\/strong\u003e 3.66 x 3.66 in\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eWarranty\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e1 year - See \u003cstrong\u003e\u003ca title=\"See CO2Meter Terms and Conditions\" href=\"https:\/\/www.co2meter.com\/pages\/terms-conditions\"\u003eCO2Meter Terms and Conditions\u003c\/a\u003e\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"documents\"\u003e\n\u003ch3\u003eDocuments\u003c\/h3\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/Data_Sheet_WH_CL_White-Amber_CO2Meter_2025Y.pdf?v=1753195432\" title=\"CO2 Storage Safety 3 Alarm Amber Horn Strobe Datasheet\"\u003e\u003cimg alt=\"Remote CO2 Storage Safety 3 Alarm\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/CO2METER_PDF.png?1093\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/Data_Sheet_MSC2-HS2Multi-Gas_Fixed_Safety_System_Alarm_Horn_Strobe_CO2Meter.pdf?v=1775478549\" title=\"Multi-Gas Fixed Safety System Alarm Horn Strobe Datasheet\"\u003e\u003cstrong\u003eData Sheet: Fixed Multi-Gas Detector Horn Strobe \u003c\/strong\u003e\u003c\/a\u003e \u003cstrong\u003e(pdf)\u003c\/strong\u003e\u003ca title=\"CO2 Storage Safety 3 Alarm Strobe Lights Datasheet\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/Data_Sheet_WH_CL_White-Amber_CO2Meter_2025Y.pdf?v=1753195432\"\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e","brand":"CO2Meter","offers":[{"title":"MSC2-HS-Clear - Fixed Multi Gas Detector Horn Strobe (Clear)","offer_id":45702167986374,"sku":"MSC2-HS-Clear","price":419.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/MSC2_Clear_Horn_Strobe_CO2Meter_1e9fa242-379e-4725-b9ae-09cb6e39d75e.jpg?v=1775479574"}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/collections\/Industrial_Fixed_Gas_Detectors.jpg?v=1776357958","url":"https:\/\/www.co2meter.com\/en-au\/collections\/fixed-gas-detection-systems.oembed","provider":"CO2 Meter","version":"1.0","type":"link"}