{"title":"CO2 Sensors","description":"\u003ch2 style=\"text-align: left;\"\u003eWhat does a CO2 sensor do?\u003c\/h2\u003e\n\u003cp style=\"text-align: left;\"\u003eFor \u003cstrong\u003eindoor air quality projects, indoor greenhouses, student projects, or connecting to Arduino or Raspberry Pi\u003c\/strong\u003e, CO2 sensors provide the easiest way to accurately measure carbon dioxide is the \u003ca href=\"\/products\/cozir-lp3-co2-sensor\" title=\"Cozir-LP3 1% Low Power CO2 Sensor\"\u003eCozIR®-LP3 1% CO2 Sensor.\u003c\/a\u003e\u003c\/p\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\u003ca href=\"https:\/\/www.co2meter.com\/collections\/gss\/products\/cozir-lp3-co2-sensor\" title=\"Cozir-Lp3 1% Low Power CO2 Sensor\"\u003e\u003cimg style=\"margin-bottom: 16px; float: left;\" alt=\"GSS Cozir-LP3 1% Low Power CO2 Sensor\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/LP3-COZIR-10000ppm-CO2-Sensor-GSS-CO2Meter_grande_bc42be06-263a-4f01-9880-243b932e3e8d_240x240.jpg?v=1638211382\"\u003e\u003c\/a\u003e\u003c\/div\u003e\n\u003cp style=\"text-align: left;\"\u003eThis sensor requires low power and features temperature stability, automatic adjustment for altitude, digital alarm, and PWM outputs.\u003c\/p\u003e\n\u003cp style=\"text-align: left;\"\u003eFor\u003cstrong\u003e scientific accuracy on a budget\u003c\/strong\u003e, we recommend \u003ca href=\"\/products\/k-30-co2-sensor-module\" title=\"K30 CO2 Sensor\"\u003eSenseAir's K30 10,000ppm CO2 sensor\u003c\/a\u003e. Used by scientists and engineers worldwide, The K30 is the most stable, accurate, and low-cost NDIR carbon dioxide sensor on the market. In fact, scientists running 2 properly calibrated K30 sensors in parallel have been able to match the accuracy requirements of CO2 meters costing tens of thousands of dollars.\u003c\/p\u003e\n\u003cp style=\"text-align: left;\"\u003eUse the USB development kit and free software to get running in minutes, or get out your soldering iron and programming skills to integrate it into any project.\u003c\/p\u003e\n\u003cp style=\"text-align: left;\"\u003e\u003ca href=\"https:\/\/us.co2meter.com\/ndir-co2-sensors\/\"\u003e\u003cspan\u003e\u003cimg style=\"display: block; margin-left: auto; margin-right: auto;\" alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/Learn_More_CO2_Sensor_Technologies_480x480.png?v=1644248687\"\u003e\u003c\/span\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp style=\"text-align: left;\"\u003e\u003cstrong\u003eOEM Manufacturers\u003c\/strong\u003e should consider the \u003ca href=\"\/products\/s8-miniature-co2-sensor-1\" title=\"S8 miniature CO2 Sensor\"\u003eS8 Miniature 10,000ppm CO2 sensor\u003c\/a\u003e. This next-generation NDIR sensor is reliable, has a small footprint, and is easy to integrate into high-volume OEM products. For applications where low power is a critical. look at the \u003ca href=\"\/products\/lp8-miniature-co2-sensor\" title=\"low power co2 sensor\"\u003eLP8 Miniature 10,000ppm CO2 Sensor\u003c\/a\u003e or the \u003ca href=\"\/products\/cozir-lp-ambient-air-co2-sensor\" title=\"low-power miniature 5,000ppm co2 sensor\" target=\"_blank\"\u003eCOZIR LP Miniature 5,000ppm CO2 Sensor\u003c\/a\u003e. Both are Designed for battery or solar-powered applications. If \u003cstrong\u003ereal-time sensing speed\u003c\/strong\u003e is important, check out the new \u003ca href=\"\/products\/sprintir6s-5-co2-smart-sensor\" title=\"fast ndir co2 sensor\"\u003eSprintIR6S 5% CO2 Sensor\u003c\/a\u003e, capable of measuring CO2 levels up to 20 times per second.\u003c\/p\u003e\n\u003ch2 style=\"text-align: left;\"\u003eWhat % CO2 Reading Do You Need?\u003c\/h2\u003e\n\u003cul style=\"text-align: left;\"\u003e\n\u003cli\u003eIndoor and outdoor air has between 400ppm and 2,000ppm CO2 by volume. This means that for projects from measuring indoor air quality to measuring atmospheric CO2, a 0-1% (0-10,000ppm) CO2 sensor is your best solution.\u003c\/li\u003e\n\u003cli\u003eFor applications like CO2 alarms in restaurants, breweries, or around stored CO2 tanks, a 5% CO2 sensor is used. OSHA requires alarms to be present at 1.5% and 5% CO2.\u003c\/li\u003e\n\u003cli\u003eOther applications like modified atmosphere packaging, bio-reactors, cryogenics, or SCUBA require sensors between 5 and 100% CO2. In general, you should know the highest level of CO2 you need to measure, then select the sensor that can read that level. This is because \u003ca title=\"CO2 Sensor Range vs Accuracy\" href=\"https:\/\/www.co2meter.com\/blogs\/news\/how-to-measure-carbon-dioxide\"\u003ethe wider the range of CO2 measured, the less precise the readings\u003c\/a\u003e.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"text-align: left;\"\u003e\u003ca href=\"\/blogs\/news\/56788737-co2-sensor-range-compared\" title=\"CO2 sensor range\"\u003eLearn more about CO2 sensor ranges here\u003c\/a\u003e.\u003c\/p\u003e","products":[{"product_id":"k-30-co2-sensor-module","title":"030-8-0006 K30 10,000 ppm CO2 Sensor","description":"\u003cp\u003eThe \u003cspan style=\"color: rgb(17, 94, 103);\"\u003e\u003cstrong\u003eK30 10,000ppm CO2 Sensor Module (030-8-0006)\u003c\/strong\u003e\u003c\/span\u003e is an industry favorite known for its low-cost, accuracy, long life and low maintenance. It is used in hundreds of HVAC and IAQ products and applications. In addition, this CO2 sensor is easy to program with several output options to meet virtually any OEM project specifications.\u003c\/p\u003e\n\u003ch2\u003eFeatures\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eIdeal for residential, commercial, HVAC or IAQ applications\u003c\/li\u003e\n\u003cli\u003eSimple to install, pre-calibrated and ready-to-use\u003c\/li\u003e\n\u003cli\u003e2 analogue outputs, 2 digital outputs\u003c\/li\u003e\n\u003cli\u003eProven reliability, low cost, maintenance free\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eModels\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eK30 CO2 Sensor\u003c\/strong\u003e (030-8-0006) - for integration into high-volume OEM products.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eK30 CO2 Sensor with Custom Outputs\u003c\/strong\u003e (030-8-0006-C) - Customize analog or digital outputs for your application. After ordering, email or fax the \u003ca title=\"Custom Outputs E-Mail Form\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/SE-0018-Configuration-Options-Form-2022.pdf\"\u003eCustom Outputs PDF form\u003c\/a\u003e and we will pre-configure your sensor’s settings. If the form is not received, your sensor will be delivered with default settings.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eK30 CO2 Sensor Development Kit\u003c\/strong\u003e (CM-0024) - Easy to use, simply plug the sensor module into your PC via USB. Use our free \u003ca title=\"Gaslab Software\" href=\"https:\/\/www.co2meter.com\/pages\/downloads\"\u003eGasLab® software\u003c\/a\u003e to measure and graph carbon dioxide in real time or for data logging.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSensor Development Kit\u003c\/strong\u003e (CM-200) - Easy to use, simply plug the sensor into the PCB and plug it into your PC via USB. Use our free \u003ca href=\"\/pages\/downloads\" title=\"Gaslab software\"\u003eGasLab® software\u003c\/a\u003e to measure and graph carbon dioxide or use our \u003ca href=\"https:\/\/github.com\/co2meter-org\/ExampleCode\" title=\"Source code on Github\" rel=\"noopener\" target=\"_blank\"\u003elibrary of source code on Github\u003c\/a\u003e to build your own application or for OEM batch testing\/configuration. Order sensors on this page, then \u003ca href=\"https:\/\/www.co2meter.com\/products\/gas-sensor-development-kit\" title=\"Gas Sensor Development Kit\"\u003eorder the Devkit here\u003c\/a\u003e.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan style=\"color: #286adc;\"\u003e\u003cstrong\u003eWe recommend that all first-time users purchase either the CM-0024 or CM-200 Development Kit for fastest and easiest results.\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cdiv class=\"specifications\"\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCO2 Measurement:\u003c\/strong\u003e non-dispersive infrared (NDIR)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMeasurement Range:\u003c\/strong\u003e 0 – 10,000 ppm (0-5,000 ppm within specifications)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRate of Measurement:\u003c\/strong\u003e every 2 seconds\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAutomatic Background Calibration (ABC):\u003c\/strong\u003e enabled unless specified\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eResponse Time Diffusion:\u003c\/strong\u003e 20 seconds\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eResponse Time Sample Draw:\u003c\/strong\u003e 2 seconds @ .5 l\/min tube gas flow\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWarm-up Time:\u003c\/strong\u003e \u0026lt; 1 min. (@ full specs \u0026lt; 15 min)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutputs:\u003c\/strong\u003e 2 analog, 2 digital\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProgrammable Range:\u003c\/strong\u003e 0-10,000 ppm (custom configuration required)\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRepeatability:\u003c\/strong\u003e ± 20 ppm ± 1 % of measured value within specifications\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAccuracy:\u003c\/strong\u003e ± 30 ppm ± 3 % of measured value within specifications\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaintenance Interval:\u003c\/strong\u003e no maintenance required\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSelf-Diagnostics:\u003c\/strong\u003e complete function check at startup\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDimensions:\u003c\/strong\u003e 51 x 58 x 14 mm (Length x Width x approximate Height)\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSensor Life Expectancy:\u003c\/strong\u003e \u0026gt; 15 years\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eConforms with Standards\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eEmission: EN61000-6-3:2001\u003c\/li\u003e\n\u003cli\u003eImmunity: EN61000-6-2:2001\u003c\/li\u003e\n\u003cli\u003eCompliant with ANSI\/ASHRAE Standard 62.1-2022\u003c\/li\u003e\n\u003cli\u003eCompliant with RESET grad B\u003c\/li\u003e\n\u003cli\u003eCompliant with WELL Building Standard® (WELL v2™)\u003c\/li\u003e\n\u003cli\u003eRoHS directive 2002\/95\/EG\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eElectrical \/ Mechanical\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003ePower Input: 5.5-14 VDC, stabilized to within 10% (external protection circuits required)\u003c\/li\u003e\n\u003cli\u003eCurrent Consumption: 40 mA average\u003c\/li\u003e\n\u003cli\u003eSampling Method: diffusion (tube cap optional)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eWarranty\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e90 days - See\u003ca title=\"Terms and Conditions\" href=\"https:\/\/www.co2meter.com\/pages\/terms-conditions\"\u003e CO2Meter Terms and Conditions.\u003c\/a\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"documents\"\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/rmtplusstoragesenseair.blob.core.windows.net\/docs\/publicerat\/PSH0131.pdf\"\u003e\u003cimg alt=\"Datasheet\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/CO2METER_PDF.png?1094\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/rmtplusstoragesenseair.blob.core.windows.net\/docs\/publicerat\/PSH0131.pdf\"\u003e\u003cstrong\u003e\u003cspan style=\"color: red;\"\u003e Data Sheet (pdf)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/Drawing_K30_K33_Revised_2023.pdf?v=1692893892\"\u003e\u003cimg alt=\"CO2 sensor drawing\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/CO2METER_PDF.png?1094\"\u003e\u003cstrong\u003e\u003cspan style=\"color: red;\"\u003e Dimensional Drawings Tube Cap Adapter (pdf)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/SenseairISO.pdf?v=1679586340\"\u003e\u003cimg alt=\"Senseair ISO Certification\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/CO2METER_PDF.png?1093\"\u003e\u003cstrong\u003e\u003cspan style=\"color: red;\"\u003e Senseair ISO Certification (pdf)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003ch3\u003eCustom Output\u003c\/h3\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/Output_Configuration_in_CO2_Engine_K30_Revised8.pdf?v=1653007118\"\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/CO2METER_PDF.png?1094\"\u003e\u003cstrong\u003e\u003cspan style=\"color: red;\"\u003e Custom Output Configuration Options (pdf)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca title=\"SE-0018 Configuration Options\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/SE-0018-Configuration-Options-Form-2022.pdf\"\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/CO2METER_PDF.png?1094\"\u003e\u003cstrong\u003e\u003cspan style=\"color: red;\"\u003e Custom Outputs E-Mail Form (pdf)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003ch4\u003eInstructions:\u003c\/h4\u003e\n\u003cp\u003e1. Download the PDF form above and save to your hard drive.\u003cbr\u003e2. Open the PDF and enter your values in the fields. Save.\u003cbr\u003e3. Please specify in the form if you wish the ABC\u003cbr\u003e(Automatic Background Calibration) on or off.\u003cbr\u003e4. Please specify in the form if you want to program the\u003cbr\u003esensor for communication with RS-485.\u003cbr\u003e5. Email as an attachment to sales@co2meter.com and reference your order code.\u003cbr\u003e6. Select \u003cstrong\u003eK30 1% Custom\u003c\/strong\u003e (030-8-0006-C) and complete your order.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"manuals\"\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/rmtplusstoragesenseair.blob.core.windows.net\/docs\/publicerat\/PSP110.pdf\"\u003e\u003cimg alt=\"Manual\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/CO2METER_PDF.png?1094\"\u003e\u003cstrong\u003e\u003cspan style=\"color: red;\"\u003e K30 1% Manual (pdf)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/DS-SenseAir-K30-CO2-Sensor-Revised-2023.pdf?v=1692893893\"\u003e\u003cimg alt=\"Datasheet\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/CO2METER_PDF.png?1094\"\u003e\u003cstrong\u003e\u003cspan style=\"color: red;\"\u003e K30 Terminal Descriptions (pdf)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/AN145-sensor-development-kit-quick-start-guide.pdf?v=1650749355\"\u003e\u003cimg alt=\"Quick Start Guide\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/CO2METER_PDF.png?1094\"\u003e\u003cstrong\u003e\u003cspan style=\"color: red;\"\u003e Devkit Quick Start Guide (pdf)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/AN_SE_0020_Sensor_Calibration_Procedure_2023.pdf?v=1692893892\"\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/CO2METER_PDF.png?1094\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/AN_SE_0020_Sensor_Calibration_Procedure_2023.pdf?v=1706541759\"\u003e\u003cstrong\u003e\u003cspan style=\"color: red;\"\u003e Sensor Calibration Procedure (pdf)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"technical-documents\"\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/rmtplusstoragesenseair.blob.core.windows.net\/docs\/Dev\/publicerat\/TDE2336.pdf\"\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/CO2METER_PDF.png?1094\"\u003e\u003cstrong\u003e\u003cspan style=\"color: red;\"\u003e Modbus Communication (pdf)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/rmtplusstoragesenseair.blob.core.windows.net\/docs\/Dev\/publicerat\/TDE4700.pdf\"\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/CO2METER_PDF.png?1094\"\u003e\u003cstrong\u003e\u003cspan style=\"color: red;\"\u003e I2C Communication (pdf)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/SenseAirCommGuide.zip?v=1638914112\"\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/assets\/zip.gif\"\u003e\u003cstrong\u003e\u003cspan style=\"color: red;\"\u003e I2C \u0026amp; Modbus Communication Example Code (zip)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/AN141-Labview-examples.zip?v=1647477681\"\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/assets\/zip.gif\"\u003e\u003cstrong\u003e\u003cspan style=\"color: red;\"\u003e Labview Examples for SenseAir K-30 (zip)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/AN_144_SE_0018_Revised8_CO2Meter.pdf?v=1710164404\"\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/CO2METER_PDF.png?1094\"\u003e\u003cstrong\u003e\u003cspan style=\"color: red;\"\u003e Web Application Using PHP and K30 DevKit (pdf)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/AN137-K30-sensor-raspberry-pi-Revised8.pdf?v=1653006660\"\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/assets\/zip.gif\"\u003e\u003cstrong\u003e\u003cspan style=\"color: red;\"\u003e Raspberry Pi UART Instructions (pdf)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/AN137-K30-sensor-raspberry-pi.zip?v=1653006700\"\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/assets\/zip.gif\"\u003e\u003cstrong\u003e\u003cspan style=\"color: red;\"\u003e Raspberry Pi UART Sample Code (zip)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/AN126-K3x-sensor-arduino-uart_2023.pdf?v=1692893893\"\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/CO2METER_PDF.png?1094\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/AN126-K3x-sensor-arduino-uart_2023.pdf?v=1715030056\"\u003e\u003cstrong\u003e\u003cspan style=\"color: red;\"\u003e Arduino UART Instructions (pdf)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/AN126-K3x-sensor-arduino-uart.zip?v=1653006884\"\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/assets\/zip.gif\"\u003e\u003cstrong\u003e\u003cspan style=\"color: red;\"\u003e Arduino UART Sample Code (zip)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/AN102-K30-Sensor-Arduino-I2C-2023.pdf?\"\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/CO2METER_PDF.png?1094\"\u003e\u003cstrong\u003e\u003cspan style=\"color: red;\"\u003e Arduino I2C Instructions (pdf)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/AN102-K30-Sensor-Arduino-I2C.zip?v=1653007039\"\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/assets\/zip.gif\"\u003e\u003cstrong\u003e\u003cspan style=\"color: red;\"\u003e Arduino I2C Sample Code (zip)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/AN_144_SE_0018_Revised8_CO2Meter.pdf?v=1710164404\"\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/CO2METER_PDF.png?1094\"\u003e\u003cstrong\u003e\u003cspan style=\"color: red;\"\u003e Troubleshooting Arduino or Raspberry Pi (pdf)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"case-studies\"\u003e\n\u003cp\u003e\u003ca title=\"CO2 Sensors compared\" href=\"\/blogs\/news\/6926946-senseair-k30-vaisala-cmm222c-elt-s100-kcd-an100-and-ge-sensing-t6615-sensor-comparison\"\u003eSenseAir K30, Vaisala CMM222C, ELT S100, KCD AN100 and GE Sensing T6615 Sensor Comparison\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca title=\"CO2 Monitoring during composting article\" href=\"\/blogs\/news\/co2-monitoring-and-composting-applications\"\u003eMonitoring CO2 Levels Critical for Compost Success\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca title=\"Haney test uses CO2 sensor\" href=\"\/blogs\/news\/haney-test-co2-sensor-soil-health\"\u003eHaney Test Uses CO2 Sensor to Measure Soil Health\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca title=\"K-30 CO2 sensor school science fair project\" href=\"\/blogs\/news\/15302513-school-science-fair-project-uses-co2meter-sensors\"\u003eSchool Science Fair Projects Using SenseAir CO2 Sensors\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca title=\"K30 sensor and Arduino Uno\" href=\"\/blogs\/news\/student-science-fair-project-co2-sensor-arduino\"\u003eStudent project combines CO2 sensor, Arduino Uno\u003c\/a\u003e\u003ca title=\"K30 sensor and CRDS CO2 measurement comparison\" href=\"\/blogs\/news\/senseair-co2-sensor-competes-with-crds-unit-that-costs-thousands-more\"\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"software\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv class=\"accessories\"\u003e\n\u003ch3\u003eAccessories\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003ca title=\"CO2Meter Gas Sensor Development Kit\" href=\"https:\/\/www.co2meter.com\/products\/gas-sensor-development-kit\"\u003e\u003cstrong\u003eGas Sensor Development Kit \u003c\/strong\u003e\u003c\/a\u003e- CM-0024 designed to provide customers with an easy drop-in solution. Includes our free \u003ca href=\"https:\/\/www.co2meter.com\/pages\/downloads\" title=\"Gaslab data logging software\"\u003eGaslab data logging software\u003c\/a\u003e. Sensor sold separately.\u003c\/li\u003e\n\u003cli\u003e\n\u003ca title=\"CO2Meter Sensor Tube Cap Adapter\" href=\"\/products\/sensor-flow-through-director\"\u003e\u003cstrong\u003eTube Cap Adapter\u003c\/strong\u003e\u003c\/a\u003e changes the sensor from reading CO2 in the air to a sample draw sensor. Use with a pump, tubing and filters to read CO2 levels in enclosed containers.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003ca href=\"\/products\/gas-sensor-micro-pump\"\u003eSample Draw Pump Kit\u003c\/a\u003e\u003c\/strong\u003e includes all the components you need with a sample draw sensor to create a closed CO2 measurement system.\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"\/products\/probe-enclosure-development-kit\" title=\"View the Probe Enclosure for Development Kits\"\u003e\u003cstrong\u003eProbe Enclosure\u003c\/strong\u003e\u003c\/a\u003e. Includes hydrophobic filters, protects the sensor when used in hostile environments.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e","brand":"Senseair","offers":[{"title":"030-8-0006 - K30 10,000ppm CO2 Sensor Module","offer_id":42786804793542,"sku":"030-8-0006","price":85.8,"currency_code":"USD","in_stock":true},{"title":"030-8-0006-C - K30 10,000ppm CO2 Custom Sensor (include form)","offer_id":19366342,"sku":"030-8-0006-C","price":142.0,"currency_code":"USD","in_stock":true},{"title":"CM-0024 - K30 Development kit","offer_id":43943390445766,"sku":"CM-0024","price":252.0,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/030-8-0006_K30_10_000ppm_CO2_Sensor_d86a0e88-d394-4f56-a14a-fa4dbd9513d3.jpg?v=1753284223"},{"product_id":"k-33-icb-co2-sensor","title":"033-9-0027 K33 ICB 30% CO2 Sensor","description":"\u003cp\u003eThe\u003cstrong\u003e \u003cspan style=\"color: #115e67;\"\u003e(033-9-0027) K33 ICB CO2 sensor\u003c\/span\u003e \u003c\/strong\u003e\u003cem\u003e(formerly known as the SE-0026)\u003c\/em\u003e is designed to measure up to 30% carbon dioxide in real time in biological or scientific applications where artificially high levels of CO2 are maintained in an enclosed apparatus.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eLong-life NDIR CO2 Sampling Sensor\u003c\/li\u003e\n\u003cli\u003eEasy communication using industry standard I\/O\u003c\/li\u003e\n\u003cli\u003eLittle interference or cross sensitivity from NO2 below and CO above\u003c\/li\u003e\n\u003cli\u003eProperly configured, can take a sample containing almost 100% humidity\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eModels\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCM-0027 K33 ICB 30% CO2 Sensor Development Kit\u003c\/strong\u003e - Easy to use, simply plug the sensor module into your PC via USB. \u003cspan\u003eThe Devkit includes a K33 ICB sensor with pre-soldered connectors that provide power and connectivity. Use it for evaluation, rapid application development or for experiments. \u003c\/span\u003eUses our free GasLab® software to measure and graph carbon dioxide, to configure the sensor or for data logging.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e033-9-0027: K33 ICB 30% CO2 Sensor Only\u003c\/strong\u003e - for integration into high-volume OEM products. Contact us directly for wholesale pricing on large quantities of this sensor. \u003ca href=\"https:\/\/www.co2meter.com\/collections\/10-co2\/products\/k-33-icb-10-co2-sensor\" title=\"high accuracy 10% co2 sensor\"\u003eFor higher accuracy 10% CO2 model click here\u003c\/a\u003e.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv class=\"specifications\"\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMeasurement Range:\u003c\/strong\u003e 0 – 300,000 ppm (0-30%)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCO2 Measurement:\u003c\/strong\u003e non-dispersive infrared (NDIR)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eResponse Time:\u003c\/strong\u003e \u0026lt;20s, diffusion or tube IN\/OUT (0.2l\/minute gas flow)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRate of Measurement:\u003c\/strong\u003e every 30 seconds\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAccuracy:\u003c\/strong\u003e \u003cspan data-teams=\"true\"\u003e±0.5% vol  ±3% of measured value\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRepeatability:\u003c\/strong\u003e \u003cspan\u003e± 0.1% vol. CO2 ± 2% of measured value\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eResolution:\u003c\/strong\u003e 0.01% \/ 100ppm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMeasurement Method:\u003c\/strong\u003e Sampling \u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCommunication Options:\u003c\/strong\u003e UART or I2C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAvailable Outputs:\u003c\/strong\u003e Digital\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSensor Life Expectancy:\u003c\/strong\u003e \u0026gt; 15 years\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaintenance Interval:\u003c\/strong\u003e no maintenance required\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSelf-Diagnostics:\u003c\/strong\u003e complete function check of the sensor module on startup\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eSensor Electrical \/ Mechanical\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Input:\u003c\/strong\u003e 5-14 VDC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCurrent Consumption:\u003c\/strong\u003e 40 mA average\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMax Current:\u003c\/strong\u003e 250 mA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDimensions:\u003c\/strong\u003e 2.0 × 2.25 × 0.62 inches\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eDevelopment Kit Includes \u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e6’ (1.8m)\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"caps\"\u003eUSB\u003c\/span\u003e -UART bridge cable (non-standard)\u003c\/li\u003e\n\u003cli\u003e6VDC universal wall power supply with connector for sensor 120\/240 VAC 50\/60 Hz\u003c\/li\u003e\n\u003cli\u003e4x AA battery pack w\/ connector for sensor\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eWarranty\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e90 days - \u003ca title=\"See CO2Meter Terms and Conditions\" href=\"https:\/\/www.co2meter.com\/pages\/terms-conditions\"\u003eSee CO2Meter Terms and Conditions\u003c\/a\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"documents\"\u003e\n\u003ch3\u003eDocuments\u003c\/h3\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/rmtplusstoragesenseair.blob.core.windows.net\/docs\/publicerat\/PSH0130.pdf\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/CO2METER_PDF.png?1094\" alt=\"Datasheet\"\u003e\u003cstrong\u003e\u003cspan style=\"color: red;\"\u003e Data Sheet (pdf)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/rmtplusstoragesenseair.blob.core.windows.net\/docs\/publicerat\/PSP141.pdf\"\u003e\u003cimg alt=\"Quick Start Guide\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/CO2METER_PDF.png?1094\"\u003e\u003cstrong\u003e\u003cspan style=\"color: red;\"\u003e Manual (pdf)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/SenseairISO.pdf?v=1613679881\"\u003e\u003cimg alt=\"Senseair ISO Certification\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/CO2METER_PDF.png?1093\"\u003e\u003cstrong\u003e\u003cspan style=\"color: red;\"\u003e Senseair ISO Certification (pdf)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/SenseAirCommGuide.zip?v=1638914112\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/assets\/zip.gif\" alt=\"\"\u003e\u003cstrong\u003e\u003cspan style=\"color: red;\"\u003e Communication Protocols Manuals (zip)\u003cbr\u003e\u003c\/span\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/AN_SE_0020_Sensor_Calibration_Procedure_2023.pdf?v=1706541759\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/CO2METER_PDF.png?1094\" alt=\"\"\u003e\u003cstrong\u003e\u003cspan style=\"color: red;\"\u003e Sensor Calibration Procedure (pdf)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003ca\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/AN171-K33-ICB-10-30-Sensor-Comparison.pdf?v=1653014626\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/CO2METER_PDF.png?1094\" alt=\"\"\u003e\u003cstrong\u003e\u003cspan style=\"color: red;\"\u003e 10% vs 30% ICB Sensor Accuracy Comparison (pdf)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003ch3\u003eCase Studies\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003ca title=\"K33 Sensor used for auto emission testing\" href=\"\/blogs\/news\/13380573-emission-reduction-in-diesel-engines-tested-with-k-33-co2-sensor\"\u003eEmission Reduction in Diesel Engines Tested with K-33 CO2 Sensor\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"software\"\u003e\n\u003ch3\u003eFree Easy-to-use Gaslab™ Software\u003c\/h3\u003e\n\u003cp\u003eThis device uses GasLab® software for setup, calibration, data logging, and real-time data analysis. GasLab® makes it easy to export data into a .CSV file that can be imported into any industry-standard software or spreadsheet. GasLab® runs on Windows XP or higher, and is free to use with our products.\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"\/pages\/downloads\"\u003e\u003cimg alt=\"Download Latest Software Here\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/download-drivers.gif?1253980035\"\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"accessories\"\u003e\n\u003ch3\u003eAccessories\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003ca href=\"\/products\/gas-sensor-micro-pump\"\u003eSample Draw Pump Kit\u003c\/a\u003e - includes pump, hose, filters\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"\/products\/usb2-0-extension-cable\"\u003eUSB Extension Cable\u003c\/a\u003e - extend USB cable 16 ft. (5m)\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"\/products\/probe-enclosure-development-kit\" title=\"Probe Enclosure for Development Kits\"\u003eProbe Enclosure for Development Kits\u003c\/a\u003e with hydrophobic filters.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e","brand":"Senseair","offers":[{"title":"033-9-0027: K33 ICB 30% CO2 Sensor","offer_id":19003982,"sku":"033-9-0027","price":164.0,"currency_code":"USD","in_stock":true},{"title":"CM-0027: K33 ICB 30% CO2 Sensor Dev Kit","offer_id":1074136612884,"sku":"CM-0027","price":362.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/033-9-00027K33ICB30_CO2SensorlCO2Meter.jpg?v=1753284217"},{"product_id":"tim10-desktop-co2-temp-humidity-monitor","title":"TIM10 Desktop CO2, Temp. \u0026 Humidity Monitor","description":"\u003cp\u003eThe \u003cspan style=\"color: #115e67;\"\u003e\u003cstrong\u003eTIM10 Desktop CO2, Temp, \u0026amp; Humidity Monitor\u003c\/strong\u003e\u003c\/span\u003e continuously shows carbon dioxide, temperature, and relative humidity levels so you can monitor the quality of air in your home, office, or indoor grow house.\u003c\/p\u003e\n\u003ch3\u003eFeatures:\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003e\u003cstrong\u003eNO MOVING PARTS:\u003c\/strong\u003e easy to use, nothing to break or wear out!\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan\u003e\u003cstrong\u003eACCURACY\u003c\/strong\u003e\u003cstrong\u003e:\u003c\/strong\u003e\u003c\/span\u003e\u003cspan\u003e\u003cstrong\u003e \u003c\/strong\u003edoes not lose accuracy in heat\/cold \u003c\/span\u003e\u003cspan\u003eenvironments\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan\u003e\u003cstrong\u003eLARGE STORAGE\u003c\/strong\u003e\u003c\/span\u003e\u003cspan\u003e\u003cstrong\u003e:\u003c\/strong\u003e ability to store data for long periods, does not lose value\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e\u003cstrong\u003eFRESH:\u003c\/strong\u003e Air Self-Calibration\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003e*Please note: All TIM10 AZ-0004 sales are final due to promotional discount price*\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003ch3\u003eABOUT CO2 STORAGE SAFETY CODES\u003c\/h3\u003e\n\u003cp\u003eThis device will \u003cspan style=\"text-decoration: underline; color: #f11111;\"\u003e\u003cstrong\u003eNOT\u003c\/strong\u003e\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003emeet requirements for CO2 safety monitoring which requires a Fixed\/Wall mounted, hard-wired alarm per the NBIC, NFPA, or IFC regulations. Refer to our\u003cspan\u003e \u003c\/span\u003e\u003ca title=\"CO2 Safety Products Page\" href=\"\/collections\/industrial-gas-safety\"\u003eCO2 Safety Products\u003c\/a\u003e\u003cspan\u003e \u003c\/span\u003epage for devices that meet your needs.\u003c\/p\u003e\n\u003cdiv class=\"specifications\"\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCO2 Range:\u003c\/strong\u003e 0 – 10,000 ppm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCO2 Accuracy:\u003c\/strong\u003e ± 70ppm ±3% reading value\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTemperature Range:\u003c\/strong\u003e +14 to +140F (-10 to +60C)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTemperature Accuracy:\u003c\/strong\u003e ±0.9 F (±0.6 C)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHumidity Range:\u003c\/strong\u003e 20-99% non-condensing (CO2 cannot be read under 20% RH)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHumidity Accuracy:\u003c\/strong\u003e ±5% RH\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDisplay:\u003c\/strong\u003e Clock, Calendar, Alarm, Temperature, Humidity and CO2\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eCO2 Air Quality Warning Alarm (Good, Normal \u0026amp; Poor)\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAlarms:\u003c\/strong\u003e 80 db audible alarm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSize:\u003c\/strong\u003e 4.72 x 3.14 in. (120 x 80 mm) diameter x depth\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e 7.05 oz (200g)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eIncludes\u003c\/h3\u003e\n110\/240 VAC International Wall AdapterUser’s Manual\n\u003ch3\u003eWarranty\u003c\/h3\u003e\n1 year - See \u003ca title=\"See CO2Meter Terms and Conditions\" href=\"https:\/\/www.co2meter.com\/pages\/terms-conditions\"\u003e\u003cstrong\u003eCO2Meter Terms and Conditions\u003c\/strong\u003e\u003c\/a\u003e\n\u003c\/div\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cdiv class=\"documents\"\u003e\n\u003ch3\u003eDocuments\u003c\/h3\u003e\n\u003cp\u003e\u003ca title=\"Data Sheet_AZ-0004-TIM10 Desktop CO2, Temp, and Humidity Monitor-co2meter\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/Data_Sheet_AZ-0004-TIM10_Desktop_CO2_Temp_and_Humidity_Monitor-20.pdf\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/CO2METER_PDF.png?1092\"\u003e\u003cstrong\u003e\u003cspan style=\"color: red;\"\u003e Data Sheet (pdf)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/Manual_AZ_0004_Revised8.pdf?v=1653500823\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/CO2METER_PDF.png?1092\"\u003e\u003cstrong\u003e\u003cspan style=\"color: red;\"\u003e Manual (pdf)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003ch3\u003eCase Studies\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003ca title=\"CO2 Meter Insures Superior Sound in Recording Booth\" href=\"\/blogs\/news\/co2-meter-insures-superior-sound-in-recording-booth\"\u003eCO2 Meter Insures Superior Sound in Recording Booth\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003ca title=\"TIM10 Helps Grow Record Onions\" href=\"\/blogs\/news\/tim10-helps-grow-record-onion\"\u003eTIM10 Helps Grow Record Onions\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"accessories\"\u003e\u003cbr\u003e\u003c\/div\u003e","brand":"AZ Instruments","offers":[{"title":"TIM10 Desktop CO2 Temp \u0026 Humidity Monitor","offer_id":44777926688966,"sku":"AZ-0004","price":39.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/AZ-0004TIM10IAQMonitor-SALE.jpg?v=1762349789"},{"product_id":"cozir-2000-ppm-co2-sensor","title":"CozIR®-A 2,000 ppm CO2 Sensor","description":"\u003cp\u003e\u003cspan\u003eThe \u003cspan style=\"color: rgb(17, 94, 103);\"\u003e\u003cstrong\u003eCozIR®-A 2,000 ppm CO2 sensor\u003c\/strong\u003e\u003c\/span\u003e is designed to monitor carbon dioxide levels indoors. It is ideal for monitoring CO2 in buildings, schools, offices, or anywhere indoor air quality is important for the personal comfort of the occupants.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eFeatures\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eLow Power Consumption\u003c\/li\u003e\n\u003cli\u003e2 measurements per second\u003c\/li\u003e\n\u003cli\u003eSensor Life Expectancy \u0026gt; 15 years\u003c\/li\u003e\n\u003cli\u003eIndustry-Standard Serial Communication\u003cb\u003e\u003cbr\u003e\u003c\/b\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eModels\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eGC-0010: CozIR®-A 2,000 ppm CO2 Sensor\u003c\/strong\u003e - \u003cspan\u003efor integration into high-volume OEM products.\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e\u003ca href=\"\/pages\/rfq\"\u003eContact us directly\u003c\/a\u003e\u003cspan\u003e \u003c\/span\u003efor wholesale pricing on large quantities of this sensor.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCM-0187: CozIR®-A Development Kit\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e-\u003cspan\u003e \u003c\/span\u003e\u003cspan\u003eEasy to use, simply plug the sensor module into your PC via USB. Use our free GasLab® software to measure and graph carbon dioxide, to configure the sensor, or for data logging.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCM-0047: Tube Cap Adapter\u003c\/strong\u003e\u003cspan\u003e - \u003c\/span\u003e\u003cstrong\u003eThis adapter has been discontinued.\u003c\/strong\u003e\u003cspan\u003e I\u003c\/span\u003e\u003cspan\u003ef you are looking for a tube cap adapter\u003c\/span\u003e\u003cspan\u003e, please contact us directly at \u003cstrong\u003eSales@CO2Meter.com\u003c\/strong\u003e\u003c\/span\u003e\u003cspan\u003e - you MUST provide us with which sensor you have purchased for a proper \u003c\/span\u003e\u003cspan\u003esolution.\u003c\/span\u003e\u003c\/p\u003e\n\u003cdiv class=\"specifications\"\u003e\n\u003cul\u003e\n\u003cli\u003eSensing Method: NDIR with Gold-plated optics\u003c\/li\u003e\n\u003cli\u003eSample Method: Diffusion (Optional Sampling with Tube Cap)\u003c\/li\u003e\n\u003cli\u003eMeasurement Range: 0-2,000 ppm (parts per million)\u003c\/li\u003e\n\u003cli\u003eMeasurement Rate: 0.5 sec \/ measurement\u003c\/li\u003e\n\u003cli\u003eAccuracy: ±50 ppm ± 3% of reading\u003c\/li\u003e\n\u003cli\u003eResolution: 1ppm\u003c\/li\u003e\n\u003cli\u003ePressure Dependence: 0.13% of reading per mm Hg\u003c\/li\u003e\n\u003cli\u003eNoise measurement: \u0026lt; 10 ppm\u003c\/li\u003e\n\u003cli\u003eAuto Calibration Default (can be changed in software)\u003c\/li\u003e\n\u003cli\u003eSerial communication 9600\/ 8\/ 1\/ n\u003c\/li\u003e\n\u003cli\u003eAnalog voltage output proportional to CO2 concentration\u003c\/li\u003e\n\u003cli\u003eSensor Life\u003cspan\u003e \u003c\/span\u003eExpectancy:\u003cspan\u003e \u003c\/span\u003e\u0026gt; 15 years\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eGeneral Performance\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eWarm-up Time: \u0026lt; 10 seconds (1.2s to first reading)\u003c\/li\u003e\n\u003cli\u003eOperating Conditions: 0°C to 50°C, 0-95% RH, 500 mbar to 40 bar\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eElectrical\/Mechanical\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003ePower Input: 3.3-5.5VDC (3.3V recommended)\u003c\/li\u003e\n\u003cli\u003eAverage Power Requirements: \u0026lt; 1.5mA @ 3.3V\u003c\/li\u003e\n\u003cli\u003ePeak current: 33mA\u003c\/li\u003e\n\u003cli\u003eWeight 20 grams\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eWarranty\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e90 days - See CO2Meter Terms and Conditions.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"documents\"\u003e\n\u003ch3\u003eDocuments\u003c\/h3\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/CozIR-A_Data_Sheet_Rev_4.11_-_Updated_Logo.pdf?v=1751037749\"\u003e\u003cimg alt=\"Datasheet\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/CO2METER_PDF.png?1093\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/CozIR-A_Data_Sheet_Rev_4.11_-_Updated_Logo.pdf?v=1751037749\"\u003e\u003cstrong\u003e\u003cspan style=\"color: red;\"\u003e Data Sheet (pdf) \u003c\/span\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/Manual_GC_0024_0025_0026_Revised8.pdf?v=1650749301\"\u003e\u003cimg alt=\"COZIR Manual\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/CO2METER_PDF.png?1093\"\u003e\u003cstrong\u003e\u003cspan style=\"color: red;\"\u003e Manual (pdf)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/CO2Meter-GSS-Cozir-A-User-Guide-Rev_4.1.pdf\"\u003e\u003cimg alt=\"COZIR GSS User Guide\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/CO2METER_PDF.png?1093\"\u003e\u003cstrong\u003e\u003cspan style=\"color: red;\"\u003e GSS COZIR A User Guide (pdf)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/AN145-sensor-development-kit-quick-start-guide.pdf?v=1650749355\"\u003e\u003cimg alt=\"Quick Start Guide\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/CO2METER_PDF.png?1093\"\u003e\u003cstrong\u003e\u003cspan style=\"color: red;\"\u003e DevKit Quick Start Guide (pdf)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/Mechanical_Diagram_-_CozIR-A_Cased-CO2Meter.pdf\"\u003e\u003cimg alt=\"Dimensional Sheet\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/CO2METER_PDF.png?1093\"\u003e\u003cstrong\u003e\u003cspan style=\"color: red;\"\u003e Dimensional Drawings (pdf)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/Mechanical_Diagram_-_CozIR-A_Cased-CO2Meter.pdf\"\u003e \u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/CO2METER_PDF.png?1093\" alt=\"Dimensional Sheet\"\u003e\u003c\/a\u003e \u003cspan style=\"color: #ff2a00;\"\u003e\u003ca title=\"Sensor Evaluation Kit\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/CO2_Sensor_Evaluation_Kit_User_Guide_9_June_2021_Rev_1.4.pdf?v=1640009264\" style=\"color: #ff2a00;\"\u003eSensor Evaluation\u003c\/a\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cstrong\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/2027_FM_ISO_Certificate.pdf?v=1742814585\"\u003e\u003cspan style=\"color: red;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/CO2METER_PDF.png?1094\" alt=\"GSS Quality Certification\"\u003e\u003cspan style=\"color: rgb(255, 42, 0);\"\u003e Quality Certificate - ISO9001 (pdf)\u003c\/span\u003e\u003c\/span\u003e\u003c\/a\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cbr\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"software\"\u003e\n\u003ch4\u003eFree Easy-to-use GasLab™ Software\u003c\/h4\u003e\n\u003cp\u003eThis device uses GasLab® software for setup, calibration, data logging, and real-time data analysis. GasLab® makes it easy to export data into a .CSV file that can be imported into any industry-standard software or spreadsheet. GasLab® runs on Windows XP or higher, and free to use with our products\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"\/pages\/downloads\"\u003e\u003cimg alt=\"Download Latest Software Here\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/download-drivers.gif?1253980035\"\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"accessories\"\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"\/products\/gas-sensor-micro-pump\"\u003eSample Draw Pump Kit\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e","brand":"GSS","offers":[{"title":"CozIR®-A 2,000ppm CO2","offer_id":72168722,"sku":"GC-0010","price":142.0,"currency_code":"USD","in_stock":false},{"title":"CozIR®-A Development Kit","offer_id":209887967,"sku":"CM-0187","price":175.0,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/products\/cozir-a-2000-ppm-co2-sensor-130252.jpg?v=1753284200"},{"product_id":"k-30-co2-sensor","title":"030-7-0007 K30 10% CO2 Sensor","description":"\u003cdiv style=\"text-align: left;\"\u003eThe \u003cspan style=\"color: #115e67;\"\u003e\u003cstrong\u003eK30 10% (100,000 ppm) CO2 sensor\u003c\/strong\u003e\u003c\/span\u003e \u003cstrong\u003e\u003c\/strong\u003e(\u003cem\u003eformerly known as SE-0118)\u003c\/em\u003e is a high performance CO2 sensor used commonly in scientific, medical, and biological applications. It is an accurate, low-cost solution for OEMs products like CO2 safety alarms or leak detectors.\u003c\/div\u003e\n\u003ch2\u003eFeatures\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eBuilt on tested K30 Sensor platform\u003c\/li\u003e\n\u003cli\u003eSimple to install, pre-calibrated and ready-to-use\u003c\/li\u003e\n\u003cli\u003eProven reliability, low cost\u003c\/li\u003e\n\u003cli\u003eFlexible analog and digital outputs\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eModels\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e030-7-0007 - K30 10% CO2 Sensor\u003c\/strong\u003e - F\u003cspan\u003eor integration into high-volume OEM products.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e030-7-0007-C - K30 10% CO2 Sensor with Custom Outputs \u003c\/strong\u003e-  Customize analog or digital outputs for your application. After ordering, email or fax the \u003cmeta charset=\"utf-8\"\u003e \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/SE-0018-Configuration-Options-Form-2022.pdf\" title=\"Custom Outputs E-Mail Form\"\u003eCustom Outputs PDF form\u003c\/a\u003e under the Documents tab and we will custom-configure your sensor’s settings. If the form is not received, your sensor will be delivered with the default specifications.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCM-0049 - K30 CO2 Sensor Development Kit\u003c\/strong\u003e - Easy to use, simply plug the sensor module into your PC via USB. Use our free \u003ca title=\"Gaslab Software\" href=\"https:\/\/www.co2meter.com\/pages\/downloads\"\u003eGasLab® software\u003c\/a\u003e to measure and graph carbon dioxide in real time or for data logging.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCM-200 - Sensor Development Kit\u003c\/strong\u003e - Easy to use, simply plug the sensor into the PCB and plug it into your PC via USB. Use our free \u003ca title=\"Gaslab software\" href=\"\/pages\/downloads\"\u003eGasLab® software\u003c\/a\u003e to measure and graph carbon dioxide or use our \u003ca rel=\"noopener\" title=\"Source code on Github\" href=\"https:\/\/github.com\/co2meter-org\/ExampleCode\" target=\"_blank\"\u003elibrary of source code on Github\u003c\/a\u003e to build your own application or for OEM batch testing\/configuration. Order sensors on this page, then \u003ca title=\"Gas Sensor Development Kit\" href=\"https:\/\/www.co2meter.com\/products\/gas-sensor-development-kit\"\u003eorder the Devkit here\u003c\/a\u003e.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan style=\"color: #286adc;\"\u003e\u003cstrong\u003eWe recommend that all first-time users purchase either the CM-0049 or CM-200 Development Kit for fastest and easiest results.\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cdiv class=\"specifications\"\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCO2 Measurement:\u003c\/strong\u003e non-dispersive infrared (NDIR)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMeasurement Method:\u003c\/strong\u003e Diffusion\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMeasurement Range:\u003c\/strong\u003e 0-100,000 ppm (0-10%)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRate of Measurement:\u003c\/strong\u003e  0.5Hz (every 2 seconds)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eResponse Time Diffusion:\u003c\/strong\u003e 20 seconds\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAccuracy:\u003c\/strong\u003e \u003cmeta charset=\"utf-8\"\u003e±30ppm ±3% of reading\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWarm-up Time:\u003c\/strong\u003e \u0026lt; 1 minute\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAvailable Outputs:\u003c\/strong\u003e 2 analog, 2 digital\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eScalable Analog voltage outputs\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eAnalog output pre-set to 3% - up to 10% available upon request\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eEach digital output has threshold and hysteresis \u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProgrammable Range:\u003c\/strong\u003e 0-100,000 ppm (custom configuration available)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCommunication Options:\u003c\/strong\u003e UART or I2C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSensor Life Expectancy:\u003c\/strong\u003e \u0026gt;15 years\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eConformance with Standards\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eEmission: EN61000-6-3:2001\u003c\/li\u003e\n\u003cli\u003eImmunity: EN61000-6-2:2001\u003c\/li\u003e\n\u003cli\u003eRoHS directive 2002\/95\/EG\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eElectrical \/ Mechanical\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eDimensions: 51 × 57 × 14 mm (Length x Width x approximate Height)\u003c\/li\u003e\n\u003cli\u003ePower Input: 4.5-14 VDC, stabilized to within 10% (external protection circuits required)\u003c\/li\u003e\n\u003cli\u003eMax Current: 300 mA\u003c\/li\u003e\n\u003cli\u003eCurrent Consumption: 40 mA average, \u0026lt; 300mA peak\u003c\/li\u003e\n\u003cli\u003eSampling Method: Diffusion (sampling kit optional)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eWarranty\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e90 days - See\u003ca title=\"Terms and Conditions\" href=\"https:\/\/www.co2meter.com\/pages\/terms-conditions\"\u003e CO2Meter Terms and Conditions.\u003c\/a\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"documents\"\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/rmtplusstoragesenseair.blob.core.windows.net\/docs\/publicerat\/PSH0131.pdf\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/CO2METER_PDF.png?1094\" alt=\"Data Sheet\"\u003e\u003cstrong\u003e\u003cspan style=\"color: red;\"\u003e Data Sheet (pdf)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/K30_10_co2_Sensor_SE-0118_Data_Sheet_Rev1220.pdf\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/CO2METER_PDF.png?1094\" alt=\"Manual\"\u003e\u003cstrong\u003e\u003cspan style=\"color: red;\"\u003e Manual (pdf)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/AN145-sensor-development-kit-quick-start-guide.pdf?v=1650749355\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/CO2METER_PDF.png?1094\" alt=\"Quick Start Guide\"\u003e\u003cstrong\u003e\u003cspan style=\"color: red;\"\u003e Devkit Quick Start Guide (pdf)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/Drawing_K30_K33_Revised8.pdf?v=1653005062\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/CO2METER_PDF.png?1094\" alt=\"CO2 sensor drawing\"\u003e\u003cstrong\u003e\u003cspan style=\"color: red;\"\u003e Dimensional Drawings (pdf)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"http:\/\/\/co2meters.com\/Documentation\/Other\/SenseairISO.pdf\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/CO2METER_PDF.png?1093\" alt=\"Senseair ISO Certification\"\u003e\u003cstrong\u003e\u003cspan style=\"color: red;\"\u003e Senseair ISO Certification (pdf)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/rmtplusstoragesenseair.blob.core.windows.net\/docs\/Dev\/publicerat\/TDE4700.pdf\"\u003e\u003cimg alt=\"\"\u003e\u003cstrong\u003e\u003cspan style=\"color: red;\"\u003e I2C \u0026amp; Modbus Communication Manuals (zip)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/AN_SE_0020_Sensor_Calibration_Procedure_2023.pdf?v=1706541759\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/CO2METER_PDF.png?1094\" alt=\"\"\u003e\u003cstrong\u003e\u003cspan style=\"color: red;\"\u003e Sensor Calibration Procedure (pdf)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/AN141-Labview-examples.zip\"\u003e\u003cimg alt=\"\"\u003e\u003cstrong\u003e\u003cspan style=\"color: red;\"\u003e Labview Examples for SenseAir K-30 (zip)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/AN_144_SE_0018_Revised8_CO2Meter.pdf\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/CO2METER_PDF.png?1094\" alt=\"\"\u003e\u003cstrong\u003e\u003cspan style=\"color: red;\"\u003e Web Application Using PHP and K30 DevKit (pdf)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/AN137-K30-sensor-raspberry-pi-Revised8.pdf?v=1653006660\"\u003e\u003cimg alt=\"\"\u003e\u003cstrong\u003e\u003cspan style=\"color: red;\"\u003e Raspberry Pi UART Instructions (pdf)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/AN137-K30-sensor-raspberry-pi.zip?v=1653006700\"\u003e\u003cimg alt=\"\"\u003e\u003cstrong\u003e\u003cspan style=\"color: red;\"\u003e Raspberry Pi UART Sample Code (zip)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/AN126-K3x-sensor-arduino-uart_2023.pdf?v=1715030056\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/CO2METER_PDF.png?1094\" alt=\"\"\u003e\u003cstrong\u003e\u003cspan style=\"color: red;\"\u003e Arduino UART Instructions (pdf)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/AN126-K3x-sensor-arduino-uart.zip?v=1679587755\"\u003e\u003cimg alt=\"\"\u003e\u003cstrong\u003e\u003cspan style=\"color: red;\"\u003e Arduino UART Sample Code (zip)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/AN102-K30-Sensor-Arduino-I2C-2023.pdf\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/CO2METER_PDF.png?1094\" alt=\"\"\u003e\u003cstrong\u003e\u003cspan style=\"color: red;\"\u003e Arduino I2C Instructions (pdf)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/AN102-K30-Sensor-Arduino-I2C.zip?v=1679587755\"\u003e\u003cimg alt=\"\"\u003e\u003cstrong\u003e\u003cspan style=\"color: red;\"\u003e Arduino I2C Sample Code (zip)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/AN_144_SE_0018_Revised8_CO2Meter.pdf?v=1702565512\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/CO2METER_PDF.png?1094\" alt=\"\"\u003e\u003cstrong\u003e\u003cspan style=\"color: red;\"\u003e Troubleshooting Arduino or Raspberry Pi (pdf)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/K30_10_Custom_Configuration_Form.pdf?v=1683822650\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/CO2METER_PDF.png?1094\" alt=\"\"\u003e\u003cstrong\u003e\u003cspan style=\"color: red;\"\u003e K30 10% Custom Configuration Form (pdf)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"software\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv class=\"accessories\"\u003e\n\u003ch3\u003eAccessories\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003ca title=\"CO2Meter Gas Sensor Development Kit\" href=\"https:\/\/www.co2meter.com\/products\/gas-sensor-development-kit\"\u003e\u003cstrong\u003eGas Sensor Development Kit \u003c\/strong\u003e\u003c\/a\u003e- designed to provide customers with an easy drop-in solution. Includes our free \u003ca href=\"https:\/\/www.co2meter.com\/pages\/downloads\" title=\"Gaslab data logging software\"\u003eGaslab data logging software\u003c\/a\u003e. Sensor sold separately.\u003c\/li\u003e\n\u003cli\u003e\n\u003ca title=\"CO2Meter Sensor Tube Cap Adapter\" href=\"\/products\/sensor-flow-through-director\"\u003e\u003cstrong\u003eTube Cap Adapter\u003c\/strong\u003e\u003c\/a\u003e changes the sensor from reading CO2 in the air to a sample draw sensor. Use with a pump, tubing and filters to read CO2 levels in enclosed containers.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003ca href=\"\/products\/gas-sensor-micro-pump\"\u003eSample Draw Pump Kit\u003c\/a\u003e\u003c\/strong\u003e includes all the components you need with a sample draw sensor to create a closed CO2 measurement system.\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"\/products\/probe-enclosure-development-kit\" title=\"View the Probe Enclosure for Development Kits\"\u003e\u003cstrong\u003eProbe Enclosure\u003c\/strong\u003e\u003c\/a\u003e. Includes hydrophobic filters, protects the sensor when used in hostile environments.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e","brand":"Senseair","offers":[{"title":"030-7-0007 - K30 10% CO2 Sensor","offer_id":79646062,"sku":"030-7-0007","price":136.4,"currency_code":"USD","in_stock":true},{"title":"030-7-0007-C - K30 10% CO2 Sensor Custom","offer_id":788193247252,"sku":"SE-0118-C-P","price":185.9,"currency_code":"USD","in_stock":true},{"title":"CM-0049 - K30 10% Sensor Development Kit","offer_id":43943410335942,"sku":"CM-0049","price":219.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/030-7-0007K3010_CO2Sensor_CO2Meter.jpg?v=1753284193"},{"product_id":"lp8-miniature-co2-sensor","title":"005-0-0001 Senseair LP8 10,000ppm CO2 Sensor","description":"\u003cp\u003eThe \u003cspan style=\"color: #115e67;\" data-mce-style=\"color: #115e67;\"\u003e\u003cstrong\u003e005-0-0001 \u003c\/strong\u003e\u003cstrong\u003eLP8 miniature 10,000 ppm CO2 sensor \u003c\/strong\u003e\u003c\/span\u003e(\u003cem\u003eformerly known as SE-0038) \u003c\/em\u003eis designed to monitor up to 10,000ppm CO2 concentrations in long-term battery or solar-powered applications.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eUltra-small footprint NDIR sensor\u003c\/li\u003e\n\u003cli\u003eOne measurement requires only \u003cspan data-mce-fragment=\"1\"\u003e11.9 mJ of energy\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003eDesigned for long-term battery operation\u003c\/li\u003e\n\u003cli\u003eVariable measurement period to save energy\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eA wide range of voltages (2.9-5.5V) enables a variety of power options. For example it can be powered by 3 alkaline 1.5V batteries, or a single 3.6V Li-SOCl2 battery for a more compact alternative.\u003c\/p\u003e\n\u003ch3\u003eModels\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e005-0-0001 LP8 Sensor Only\u003c\/strong\u003e - \u003cspan\u003efor integration into high-volume OEM products.\u003c\/span\u003e \u003ca href=\"https:\/\/www.co2meter.com\/pages\/rfq\" target=\"_blank\"\u003eContact us directly\u003c\/a\u003e for wholesale pricing on large quantities of this sensor.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv class=\"specifications\"\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCO2 Measurement:\u003c\/strong\u003e non-dispersive infrared (NDIR)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMeasurement Range:\u003c\/strong\u003e 0-10,000ppm CO2\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAccuracy:\u003c\/strong\u003e ± 50ppm, ± 3% of reading\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eResponse Time:\u003c\/strong\u003e 30 seconds\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMeasurement Method:\u003c\/strong\u003e Diffusion\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMeasurement Period:\u003c\/strong\u003e \u0026gt;15 seconds\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAvailable Output:\u003c\/strong\u003e Digital only\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCommunication:\u003c\/strong\u003e UART (host-slave protocol)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaintenance Interval:\u003c\/strong\u003e no maintenance required\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSelf-Diagnostics:\u003c\/strong\u003e complete function check on startup\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDimensions: \u003c\/strong\u003e\u003cspan data-mce-fragment=\"1\"\u003e32.7 × 19.7 × 8 mm (LxWxH)  \u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight: \u003c\/strong\u003e\u0026lt;8 grams\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSensor Life Expectancy:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e\u0026gt;15 years\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eElectrical \/ Mechanical\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Input:\u003c\/strong\u003e 2.9-5.5 VDC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMax Current: \u003c\/strong\u003e0.6 mA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCharge per measurement:\u003c\/strong\u003e 3.6mC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnergy per measurement:\u003c\/strong\u003e 11.9mJ @ 3.3V\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eWarranty\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e90 days - See CO2Meter Terms and Conditions \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"documents\"\u003e\n\u003ch3\u003eDocuments\u003c\/h3\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/rmtplusstoragesenseair.blob.core.windows.net\/docs\/Dev\/publicerat\/PSH1233.pdf\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/CO2METER_PDF.png?1094\" alt=\"CO2 Sensor Documention\"\u003e\u003cstrong\u003e\u003cspan style=\"color: red;\" data-mce-style=\"color: red;\"\u003e LP8 Sensor Datasheet (pdf)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/rmtplusstoragesenseair.blob.core.windows.net\/docs\/Dev\/publicerat\/PSP1334.pdf\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/CO2METER_PDF.png?1094\" alt=\"CO2 Sensor Documention\"\u003e\u003cstrong\u003e\u003cspan style=\"color: red;\" data-mce-style=\"color: red;\"\u003e LP8 Sensor Manual (pdf)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/AN_170_SE_0037_CO2_Sensor_Development_Kit_Revised8.pdf?v=1653015508\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/CO2METER_PDF.png?1094\" alt=\"CO2 Sensor Documention\"\u003e\u003cstrong\u003e\u003cspan style=\"color: red;\" data-mce-style=\"color: red;\"\u003e LP8 Sensor Power Options (pdf)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/AN_SE_0038_AN162_Revised8.pdf?v=1653015739\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/CO2METER_PDF.png?1094\" alt=\"CO2 Sensor Documention\"\u003e\u003cstrong\u003e\u003cspan style=\"color: red;\" data-mce-style=\"color: red;\"\u003e LP8 to Arduino via UART (pdf)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/SenseairISO.pdf?v=1613679881\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/CO2METER_PDF.png?1093\" alt=\"Senseair ISO Certification\"\u003e\u003cstrong\u003e\u003cspan style=\"color: red;\" data-mce-style=\"color: red;\"\u003e Senseair ISO Certification (pdf)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"software\"\u003e\u003c\/div\u003e\n\u003cdiv class=\"accessories\"\u003e\u003c\/div\u003e","brand":"Senseair","offers":[{"title":"LP8 CO2 Sensor","offer_id":22021514759,"sku":"005-0-0001","price":88.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/005-0-0001SenseairLP810_000ppmCO2SensorlCO2Meter_SE-0038.jpg?v=1753284191"},{"product_id":"sprintir6s-100-co2-smart-sensor","title":"SprintIR®-6S-100 100% CO2 Sensor","description":"\u003cp\u003eThe\u003cstrong\u003e \u003cspan style=\"color: #115e67;\"\u003eSprintIR®-6S-100 100% CO2 Sensor\u003c\/span\u003e\u003c\/strong\u003e\u003cem\u003e (formerly known as the GC-0030)\u003c\/em\u003e is a high-speed CO2 sensor that can take up to 20 readings per second, It is for fire suppression testing and safety applications.\u003c\/p\u003e\n\u003cp\u003eThis sensor is fitted with a standard flow-through adaptor so the CO2 gas can be passed over the optical sensor at high speed.\u003c\/p\u003e\n\u003cp\u003eThe SprintIR®-6S-100 uses patented NDIR solid-state LED optical technology enabling the sensor to respond to rapidly changing CO2 without compromising parametric performance.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eNDIR LED sensor measures up to 100% CO2\u003c\/li\u003e\n\u003cli\u003eFast response rate - 20 readings\/second\u003c\/li\u003e\n\u003cli\u003eVibration and shock resistant\u003c\/li\u003e\n\u003cli\u003eEasy integration in compact environments\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eModels\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSprintIR-6S 100% CO2 Sensor\u003c\/strong\u003e (SPRINTIR-6S-100)– for integration into high-volume OEM products.\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSensor Development Kit\u003c\/strong\u003e (CM-200) - Easy to use, simply plug the sensor into the PCB and plug it into your PC via USB. Use our free \u003ca title=\"Gaslab software\" href=\"\/pages\/downloads\"\u003eGasLab® software\u003c\/a\u003e to measure and graph carbon dioxide or use our \u003ca rel=\"noopener\" title=\"Source code on Github\" href=\"https:\/\/github.com\/co2meter-org\/ExampleCode\" target=\"_blank\"\u003elibrary of source code on Github\u003c\/a\u003e to build your own application or for OEM batch testing\/configuration. Order sensors on this page, then \u003ca title=\"Gas Sensor Development Kit\" href=\"https:\/\/www.co2meter.com\/products\/gas-sensor-development-kit\"\u003eorder the Devkit here\u003c\/a\u003e.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan style=\"color: #286adc;\"\u003e\u003cstrong\u003eWe recommend that all first-time users purchase either the CM-20801 or CM-200 Development Kit for fastest and easiest results\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cdiv class=\"specifications\"\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCO2 Sensing Method:\u003c\/strong\u003e Non-dispersive infrared (NDIR) absorption\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSample Method:\u003c\/strong\u003e Flow through\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMeasurement Range\u003c\/strong\u003e: 0-100%\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAccuracy:\u003c\/strong\u003e ±70 ppm +\/- 5% of reading @ STP\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAccuracy @ 100% Range:\u003c\/strong\u003e ±300 ppm +\/-5% of reading @ STP\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating Conditions - Temperature: \u003c\/strong\u003e0°C to 50°C\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eStorage Conditions - Temperature: \u003c\/b\u003e-40°C to +70°C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating Conditions - Humidity: \u003c\/strong\u003e0-95% RH, non-condensing\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eResolution:\u003c\/strong\u003e 100ppm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNon Linearity:\u003c\/strong\u003e \u0026lt; 1% of FS\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePressure Dependence:\u003c\/strong\u003e 0.13% of reading per mbar @STP\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWarm-up Time:\u003c\/strong\u003e \u0026lt; 30s.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eResponse Time:\u003c\/strong\u003e Flow Rate Dependent\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating Conditions:\u003c\/strong\u003e 0°C to 50°C, 0 to 95% RH, non-condensing\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSensor Life Expectancy:\u003c\/strong\u003e \u0026gt; 15 years\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eElectrical \/ Mechanical\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Input:\u003c\/strong\u003e 3.25 to 5.5V. (3.3V recommended)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePeak Current:\u003c\/strong\u003e 33mA @ 2 readings\/sec.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAverage Current:\u003c\/strong\u003e \u0026lt;12mA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Consumption:\u003c\/strong\u003e 3.5mW @ 2 readings\/sec.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInterface:\u003c\/strong\u003e UART (Serial)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDimensions:\u003c\/strong\u003e 25mm x 40mm x 31mm on PCB (L x W x H)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e 16g sensor, 5.8g board\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eWarranty\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e90 days - See\u003ca title=\"Terms and Conditions\" href=\"https:\/\/www.co2meter.com\/pages\/terms-conditions\"\u003e CO2Meter Terms and Conditions\u003c\/a\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"documents\"\u003e\n\u003ch3\u003eDocuments\u003c\/h3\u003e\n\u003cp\u003e\u003ca title=\"GSS and CO2Meter Product Flyer\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/SprintIR-6S_Data_Sheet_Rev_4.12_-_Updated_Logo.pdf?v=1751034889\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/CO2METER_PDF.png?1094\" alt=\"SprintIR-6S Data Sheet\"\u003e\u003cstrong\u003e\u003cspan style=\"color: red;\"\u003e Data Sheet (pdf)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca title=\"GSS and CO2Meter User Manual and Data Sheet\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/SprintIR-6S_Data_Sheet_Rev_4.12_-_Updated_Logo.pdf?v=1751034889\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/CO2METER_PDF.png?1094\" alt=\"SprintIR-6-S Manual\"\u003e\u003cstrong\u003e\u003cspan style=\"color: red;\"\u003e Sensor Manual (pdf)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/Mechanical_Diagram_-SprintIR-6S-CO2Meter.pdf\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/CO2METER_PDF.png?1094\" alt=\"Mechanical Diagram\"\u003e\u003cstrong\u003e\u003cspan style=\"color: red;\"\u003e Mechanical Diagram (pdf)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/AN015_Using_a_pump_to_sample_gas_Application_Note_Rev_1.1.pdf?v=1651156092\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/CO2METER_PDF.png?1094\" alt=\"\"\u003e\u003cstrong\u003e\u003cspan style=\"color: red;\"\u003e GSS Guide for Sample Draw Pumps (pdf)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/SprintIR-Speed-Comparison.pdf?v=1653495789\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/CO2METER_PDF.png?1094\" alt=\"\"\u003e\u003cstrong\u003e\u003cspan style=\"color: red;\"\u003e SprintIR Speed Comparison Test (pdf)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan style=\"color: red;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/2027_FM_ISO_Certificate.pdf?v=1742814585\"\u003e\u003cimg alt=\"GSS Quality Certification\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/CO2METER_PDF.png?1094\"\u003e\u003cspan style=\"color: rgb(255, 42, 0);\"\u003e Quality Certificate - ISO9001 (pdf)\u003c\/span\u003e\u003c\/a\u003e\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"\/pages\/co2meter-resources\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/CO2METER_PDF.png?1094\" alt=\"\"\u003e\u003cstrong\u003e\u003cspan style=\"color: red;\"\u003e Additional Application Notes\u003c\/span\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"software\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv class=\"accessories\"\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/www.co2meter.com\/products\/gas-sensor-development-kit\" title=\"CO2Meter Gas Sensor Development Kit\"\u003e\u003cstrong\u003eGas Sensor Development Kit\u003c\/strong\u003e (CM-200)\u003c\/a\u003e- designed to provide customers with an easy drop-in solution. Includes our free \u003ca title=\"Gaslab data logging software\" href=\"https:\/\/www.co2meter.com\/pages\/downloads\"\u003eGaslab data logging software\u003c\/a\u003e. Sensor sold separately.\u003c\/p\u003e\n\u003cp\u003e\u003ca title=\"micro-pump kit\" href=\"\/products\/gas-sensor-micro-pump\"\u003e\u003cstrong\u003eMicro-Pump Kit\u003c\/strong\u003e\u003c\/a\u003e\u003cspan\u003e \u003c\/span\u003eincludes all the tools you need to utilize the tube-cap adapters as part of a sampling sensor system.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003ca title=\"nafion tubing\" href=\"\/products\/nafion-gas-sample-drying-tubing\"\u003eNafion Tubing\u003c\/a\u003e \u003c\/strong\u003eis a highly selective, semi-permeable membrane to water vapor. If gases inside Nafion tubing are wetter than gases surrounding the tubing, drying will occur. If the surrounding gases are wetter, humidification will occur.\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"\/products\/gas-sampling-pump\"\u003e\u003cstrong\u003eMicro Gas Sampling Pumps\u003c\/strong\u003e\u003c\/a\u003e provide a constant flow of air across the sensor with a tube cap - perfect for bench-top testing of sensors for closed-loop sampling applications.\u003c\/p\u003e\n\u003c\/div\u003e","brand":"GSS","offers":[{"title":"SPRINTIR-6S-100: SprintIR-6S 100% CO2 Sensor","offer_id":43948874924230,"sku":"SPRINTIR-6S-100","price":318.0,"currency_code":"USD","in_stock":true},{"title":"CM-20800: CO2 100% SprintIR-6S Sensor w\/ MX Board","offer_id":43960919195846,"sku":"CM-20800","price":445.0,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/SprintIR_-6S100_CO2SensorlCO2MeterCM-20801.jpg?v=1753284151"},{"product_id":"cozir-wr-5-percent-co2-sensor","title":"ExplorIR®-W 5% CO2 Sensor","description":"\u003cp\u003eThe \u003cspan style=\"color: #115e67;\"\u003e\u003cstrong\u003eExplorIR®-W\u003c\/strong\u003e\u003c\/span\u003e \u003cspan\u003e(formerly known as CozIR Wide Range) \u003c\/span\u003eis a low power, high performance CO2 sensor that measures 5% CO2 in battery powered and portable alarm monitoring applications.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e0-5% CO2 Measurement\u003c\/li\u003e\n\u003cli\u003eDurable, low power consumption\u003c\/li\u003e\n\u003cli\u003eIndustry standard serial communication\u003c\/li\u003e\n\u003cli\u003eIdeal for battery powered applications, or harsh\/rugged environments\u003c\/li\u003e\n\u003cli\u003eSimple to install, pre-calibrated and ready-to-use\u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eModels\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eGC-0015 ExplorIR®-W 5% CO2 Sensor Only\u003c\/strong\u003e - \u003cspan\u003efor integration into high-volume OEM products.\u003c\/span\u003e \u003ca href=\"https:\/\/www.co2meter.com\/pages\/rfq\" target=\"_blank\"\u003eContact us directly\u003c\/a\u003e for wholesale pricing on large quantities of this sensor.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCM-0124 ExplorIR®-W 5% CO2 Sensor Development Kit \u003c\/strong\u003e- \u003cspan\u003eEasy to use, simply plug the sensor module into your PC via the included serial UART to USB cable. Use our free GasLab® software to measure and graph carbon dioxide, to configure the sensor or for data logging.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv class=\"specifications\"\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMeasurement Range:\u003c\/strong\u003e 0-5% CO2\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSensing Method:\u003c\/strong\u003e NDIR with Gold-plated optics\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSample Method:\u003c\/strong\u003e Diffusion (default) or sampling with optional tube adapter\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAccuracy:\u003c\/strong\u003e ±70 ppm ± 5% of reading\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eResolution:\u003c\/strong\u003e 10ppm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSample Rate:\u003c\/strong\u003e 500 ms (2 Hz) measurement interval\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eResponse Time Filter:\u003c\/strong\u003e 4 secs to 2 mins (user configurable)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSerial communications:\u003c\/strong\u003e 9600\/8\/1\/N\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWarm-up Time:\u003c\/strong\u003e \u0026lt; 10s\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating Conditions:\u003c\/strong\u003e 0°C to 50°C, 950 mBar to 10 Bar\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e8g\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSensor Life Expectancy:\u003c\/strong\u003e \u0026gt; 15 years\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eElectrical\/Mechanical\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Input:\u003c\/strong\u003e 3.3 ±0.1 volt  DC \u0026lt; 3.5 mW\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePeak current:\u003c\/strong\u003e 33mA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDevkit includes 6’ (1.8m) \u003cspan class=\"caps\"\u003eUSB\u003c\/span\u003e cable (non-standard)\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eWarranty\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e90 days - See \u003ca href=\"https:\/\/www.co2meter.com\/pages\/terms-conditions\" title=\"CO2Meter Terms and Conditions\"\u003e\u003cstrong\u003eCO2Meter Terms and Conditions.\u003c\/strong\u003e\u003c\/a\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"documents\"\u003e\n\u003ch3\u003eDocuments\u003c\/h3\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/Datasheet_ExplorIR_W_CO2Meter_4_15-compressed.pdf\"\u003e\u003cimg alt=\"Datasheet\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/CO2METER_PDF.png?1093\"\u003e\u003cstrong\u003e\u003cspan style=\"color: red;\"\u003e Data Sheet (pdf)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/Manual_GC_0024_0025_0026_Revised8.pdf?v=1679587743\"\u003e\u003cimg alt=\"COZIR Manual\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/CO2METER_PDF.png?1093\"\u003e\u003cstrong\u003e\u003cspan style=\"color: red;\"\u003e Manual (pdf)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/AN145-sensor-development-kit-quick-start-guide.pdf?v=1650749355\"\u003e\u003cimg alt=\"Quick Start Guide\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/CO2METER_PDF.png?1093\"\u003e\u003cstrong\u003e\u003cspan style=\"color: red;\"\u003e Devkit Quick Start Guide (pdf)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/CO2Meter-GSS-White-Paper-Incubation.pdf\"\u003e\u003cimg alt=\"Incubation White Paper\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/CO2METER_PDF.png?1094\"\u003e\u003cstrong\u003e\u003cspan style=\"color: red;\"\u003e Incubation White Paper (pdf)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/Mechanical_Diagram_-ExplorIR-W-CO2Meter.pdf\"\u003e\u003cimg alt=\"Dimensional Drawings\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/CO2METER_PDF.png?1093\"\u003e\u003cstrong\u003e\u003cspan style=\"color: red;\"\u003e Dimensional Drawings (pdf)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/AN_128_GC_15_16_7_5_Revised8.pdf?v=1652981868\"\u003e\u003cimg alt=\"Documentation\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/CO2METER_PDF.png?1093\"\u003e\u003cstrong\u003e\u003cspan style=\"color: red;\"\u003e Arduino Sample Code (pdf)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan style=\"color: red;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/2027_FM_ISO_Certificate.pdf?v=1742814585\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/CO2METER_PDF.png?1094\" alt=\"GSS Quality Certification\"\u003e\u003cspan style=\"color: rgb(255, 42, 0);\"\u003e Quality Certificate - ISO9001 (pdf)\u003c\/span\u003e\u003c\/a\u003e\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/AN141-Labview-examples.zip?v=1647477681\"\u003e\u003cimg alt=\"Documentation\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/assets\/zip.gif\"\u003e\u003cstrong\u003e\u003cspan style=\"color: red;\"\u003e Labview Examples for COZIR CO2 Sensors (zip)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cbr\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"software\"\u003e\n\u003ch3\u003eFree Easy-to-use GasLab™ Software\u003c\/h3\u003e\n\u003cp\u003eThis device uses GasLab® software for setup, calibration, data logging, and real-time data analysis. GasLab® makes it easy to export data into a .CSV file that can be imported into any industry-standard software or spreadsheet. GasLab® runs on Windows XP or higher, and free to use with our products.\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"http:\/\/www.co2meter.com\/pages\/downloads\"\u003e\u003cimg alt=\"Download Latest Software Here\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/download-drivers.gif?1253980035\"\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"accessories\"\u003e\n\u003ch3\u003eAccessories\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/www.co2meter.com\/collections\/accessories\/products\/probe-enclosure-development-kit\" title=\"View the Probe Enclosure for Development Kits\" target=\"_blank\"\u003eProbe Enclosure for Development Kits and Hydrophobic Filter Option\u003c\/a\u003e \u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e\u003ca href=\"https:\/\/www.co2meter.com\/products\/co2meter-sensor-tube-cap\" title=\"Sensor Tube Cap Adapter\" target=\"_blank\"\u003eTC1-5 Tube Cap Adapter\u003c\/a\u003e - easily converts a wide range of gas sensors from diffusion applications to sampling. \u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e","brand":"GSS","offers":[{"title":"GC-0015: ExplorIR®-W 5% CO2 Sensor","offer_id":828167127060,"sku":"GC-0015","price":142.0,"currency_code":"USD","in_stock":false},{"title":"CM-0124: ExplorIR®-W 5% CO2 Sensor Development Kit","offer_id":828167159828,"sku":"CM-0124","price":197.0,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/products\/explorir-w-5-co2-sensor-291992.jpg?v=1753284143"},{"product_id":"ndir-high-accuracy-co2-sensor","title":"CM1106H-NS NDIR CO2 Sensor","description":"\u003cp\u003eThe \u003cstrong\u003eCM1106H-NS High Accuracy NDIR CO2 Sensor \u003c\/strong\u003e(CU-1106H-NS) is a single beam, low cost CO2 sensor designed for OEMs to hobbyists. The sensor uses non-dispersive infrared (NDIR) technology, which can detect CO2 concentration of indoor air. With high accuracy, high stability, and a small size it is widely used for ventilation systems, air purifiers, air conditioners, HVAC transmitters, and IAQ monitors.\u003c\/p\u003e\n\u003cp\u003eThis sensor is designed to support WELL, RESET, ASHRAE 62.1 2019 Addendum aa \u0026amp; California Title 24 Applications.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eHigh accuracy and precise measurement\u003c\/li\u003e\n\u003cli\u003eNDIR sensor outputs either UART and PWM\u003c\/li\u003e\n\u003cli\u003eMaintenance free - Automatic Baseline Calibration (ABC)\u003c\/li\u003e\n\u003cli\u003eTemperature and humidity compensation throughout the entire measurement range\u003c\/li\u003e\n\u003cli\u003eLong life span (15+ years)\u003c\/li\u003e\n\u003cli\u003eSmall, Compact structure, easy to install\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eIndoor Air Quality\u003c\/li\u003e\n\u003cli\u003eVentilation Systems\u003c\/li\u003e\n\u003cli\u003eAir Purification\u003c\/li\u003e\n\u003cli\u003eHVAC\u003c\/li\u003e\n\u003cli\u003eDemand Control Ventilation\u003c\/li\u003e\n\u003cli\u003eAutomotive\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eModels\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCM1106H-NS: \u003c\/strong\u003eHigh Accuracy NDIR CO2 Sensor - for OEMs or hobbyists\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCU-1106H-NS-DK Development Kit\u003c\/strong\u003e - Includes the CU-1106H-NS sensor plus a USB\/FTDI cable to communicate with our free GasLab software. \u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSensor Development Kit\u003c\/strong\u003e (CM-200) - Easy to use, simply plug the sensor into the PCB and plug it into your PC via USB. Use our free \u003ca title=\"Gaslab software\" href=\"\/pages\/downloads\"\u003eGasLab® software\u003c\/a\u003e to measure and graph carbon dioxide or use our \u003ca rel=\"noopener\" title=\"Source code on Github\" href=\"https:\/\/github.com\/co2meter-org\/ExampleCode\" target=\"_blank\"\u003elibrary of source code on Github\u003c\/a\u003e to build your own application or for OEM batch testing\/configuration. Order sensors on this page, then \u003ca title=\"Gas Sensor Development Kit\" href=\"https:\/\/www.co2meter.com\/products\/gas-sensor-development-kit\"\u003eorder the Devkit here\u003c\/a\u003e. Note: pinned sensors may require minor pin clipping.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan style=\"color: #286adc;\"\u003e\u003cstrong\u003eWe recommend that all first time users purchase both this sensor and the CM-200 Development Kit for fastest and easiest results.\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cdiv class=\"specifications\"\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eGas Type: CO2 (Carbon Dioxide)\u003c\/li\u003e\n\u003cli\u003eOperating Principle: Non-dispersive infrared (NDIR)\u003c\/li\u003e\n\u003cli\u003eCO2 Range: PWM (0-2,000 ppm), UART (0-10,000 ppm)\u003c\/li\u003e\n\u003cli\u003eCO2 Accuracy: ± (30ppm+3% of reading) @ -10°C~50°C ,0-85%RH, UART\/PWM 0-2,000 ppm\u003c\/li\u003e\n\u003cli\u003eResponse time: 30s\u003c\/li\u003e\n\u003cli\u003eWorking Temperature: -10°C~+50°C\u003c\/li\u003e\n\u003cli\u003eWorking Humidity: 0-95%RH (non condensing)\u003c\/li\u003e\n\u003cli\u003eStorage Temperature: -30°C ~ 70°C\u003c\/li\u003e\n\u003cli\u003eStorage Humidity: 0-95%RH (non-condensing)\u003c\/li\u003e\n\u003cli\u003eSampling Frequency: 1s\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eTime to First Reading: ≤30s \u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003ePower Supply: DC4.5V-5.5V\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eRipple Wave: \u0026lt;50mV\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eWorking Current: \u0026lt;50mA @ 1s\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003eSignal output: UART-TTL, PWM\u003c\/li\u003e\n\u003cli\u003eDimensions: 33 x 19.7 x 8.9 mm\u003c\/li\u003e\n\u003cli\u003eWeight: 5g\u003c\/li\u003e\n\u003cli\u003eLifespan: ≥10 years\u003c\/li\u003e\n\u003cli\u003eMaintenance: Maintenance-free for normal indoor application with ABC\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eWarranty\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e90 days - See\u003ca title=\"Terms and Conditions\" href=\"https:\/\/www.co2meter.com\/pages\/terms-conditions\"\u003e CO2Meter Terms and Conditions.\u003c\/a\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"documents\"\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/innovaertech.com\/wp-content\/uploads\/2022\/05\/CM1106H-NS.pdf\" data-mce-href=\"https:\/\/innovaertech.com\/wp-content\/uploads\/2022\/05\/CM1106H-NS.pdf\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/CO2METER_PDF.png?1094\" alt=\"Manual\"\u003e\u003cstrong\u003e\u003cspan style=\"color: red;\"\u003e Manual (pdf)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"accessories\"\u003e\n\u003ch3\u003eAccessories\u003c\/h3\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/www.co2meter.com\/products\/gas-sensor-development-kit\" title=\"CO2Meter Gas Sensor Development Kit\"\u003e\u003cstrong\u003eGas Sensor Development Kit\u003c\/strong\u003e (CM-200)\u003c\/a\u003e- designed to provide customers with an easy drop-in solution. Includes our free \u003ca title=\"Gaslab data logging software\" href=\"https:\/\/www.co2meter.com\/pages\/downloads\"\u003eGaslab data logging software\u003c\/a\u003e. Sensor sold separately.\u003c\/p\u003e\n\u003c\/div\u003e","brand":"CO2 Meter","offers":[{"title":"CM1106H-NS: Cubic NDIR CO2 Sensor","offer_id":43961001181382,"sku":"CM1106H-NS","price":50.0,"currency_code":"USD","in_stock":true},{"title":"CU-1106H-NS-DK: Cubic NDIR CO2 Sensor Development Kit","offer_id":43961001214150,"sku":"CU-1106H-NS-DK","price":76.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/CM1106H-NS.jpg?v=1753284100"},{"product_id":"sprintir-r-20-co2-sensor","title":"SPRINTIR®-R 20% CO2 Sensor","description":"\u003cp\u003eThe \u003cspan style=\"color: #115e67;\"\u003e\u003cstrong\u003eSprintIR®-R 20% CO2 Sensor\u003c\/strong\u003e\u003c\/span\u003e \u003cem\u003e(formerly known as GC-0032)\u003c\/em\u003e\u003cstrong\u003e \u003c\/strong\u003eis the fastest carbon dioxide sensor on the market. Capable of measuring up to 20% CO2 levels up to 50 times a second, this sensor is designed for applications where high speed between measurements and fast response time are most important\u003c\/p\u003e\n\u003cp\u003eThis sensor is fitted with a standard flow-through adaptor so the CO2 gas can be passed over the optical sensor at high speed using an optional micro-pump.\u003c\/p\u003e\n\u003cp\u003eThe SprintIR®-R-5 uses patented NDIR solid-state LED optical technology enabling the sensor to respond to rapidly changing CO2 without compromising performance.\u003c\/p\u003e\n\u003ch2\u003eFeatures\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eTakes 50 readings per second\u003c\/li\u003e\n\u003cli\u003eOptional customized flow through adapters\u003c\/li\u003e\n\u003cli\u003eBuilt-in auto-zero functionality\u003c\/li\u003e\n\u003cli\u003eDigital (UART) data interface\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eRoHS and REACH compliant\u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eModels\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eGC-0032\u003c\/strong\u003e – 20% CO2 Sensor only, for integration into high-volume OEM products.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCM-20420\u003c\/strong\u003e – 20% CO2 Sensor w\/ MX Board\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eCM-20421\u003c\/b\u003e– 20% CO2 Sensor and Development Kit\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSensor Development Kit\u003c\/strong\u003e (CM-200) - Easy to use, simply plug the sensor into the PCB and plug it into your PC via USB. Use our free \u003ca title=\"Gaslab software\" href=\"\/pages\/downloads\"\u003eGasLab® software\u003c\/a\u003e to measure and graph carbon dioxide or use our \u003ca rel=\"noopener\" title=\"Source code on Github\" href=\"https:\/\/github.com\/co2meter-org\/ExampleCode\" target=\"_blank\"\u003elibrary of source code on Github\u003c\/a\u003e to build your own application or for OEM batch testing\/configuration. Order sensors on this page, then \u003ca title=\"Gas Sensor Development Kit\" href=\"https:\/\/www.co2meter.com\/products\/gas-sensor-development-kit\"\u003eorder the Devkit here\u003c\/a\u003e.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan style=\"color: #286adc;\"\u003e\u003cstrong\u003eWe recommend that all first time users purchase both this sensor and the CM-200 Development Kit for fastest and easiest results.\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cdiv class=\"specifications\"\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCO2 Sensing Method:\u003c\/strong\u003e Patented solid-state NDIR absorption\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMeasurement Range:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e0-20% CO2\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSample Method:\u003c\/strong\u003e Flow through adapter\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAccuracy:\u003c\/strong\u003e ±70 ppm +\/- 5% of reading @ STP\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTime to 1st Reading: \u003c\/strong\u003e\u0026lt;0.2 Seconds\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eResponse Time: \u003c\/strong\u003eFlow Dependent\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eReadings per Second: \u003c\/strong\u003e50\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eResolution:\u003c\/strong\u003e 10ppm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMeasurement Noise:\u003c\/strong\u003e \u0026lt;10% of reading with no digital filtering\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePressure Dependence:\u003c\/strong\u003e 0.15% of reading per mbar in normal conditions\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWarm-up Time:\u003c\/strong\u003e \u0026lt; 30s\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating Conditions:\u003c\/strong\u003e 0°C to 50°C, 0 to 95% RH, non-condensing\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDimensions: \u003c\/strong\u003e24.8mm x 28mm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e7.5g\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSensor Life Expectancy:\u003c\/strong\u003e \u0026gt;15 years\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eElectrical \/ Mechanical\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Input:\u003c\/strong\u003e 3.25V to 5.5V. (3.3V recommended)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Consumption (typ.): \u003c\/strong\u003e100mW @3.3V\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePeak Current:\u003c\/strong\u003e 100mA @ 2 readings\/sec.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAverage Current:\u003c\/strong\u003e \u0026lt;15mA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Consumption:\u003c\/strong\u003e 35mW\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMeasurement Output\/Interface:\u003c\/strong\u003e UART\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eWarranty\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e90 days - See\u003ca title=\"Terms and Conditions\" href=\"https:\/\/www.co2meter.com\/pages\/terms-conditions\"\u003e CO2Meter Terms and Conditions\u003c\/a\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"documents\"\u003e\n\u003ch3\u003eDocuments\u003c\/h3\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/SprintIR-R_Data_Sheet_Rev_4.12_-_Updated_Logo.pdf?v=1751034701\" title=\"GSS and CO2Meter Product Flyer\"\u003e\u003cimg alt=\"SprintIR R Data Sheet\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/CO2METER_PDF.png?1094\"\u003e\u003cstrong\u003e\u003cspan style=\"color: red;\"\u003e Data Sheet (pdf)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/Mechanical_Diagram_-SprintIR-6S-CO2Meter.pdf\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/CO2METER_PDF.png?1094\" alt=\"Mechanical Diagram\"\u003e\u003cstrong\u003e\u003cspan style=\"color: red;\"\u003e Mechanical Diagram (pdf)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/2027_FM_ISO_Certificate.pdf?v=1742814585\"\u003e\u003cstrong\u003e\u003cspan style=\"color: red;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/CO2METER_PDF.png?1094\" alt=\"GSS Quality Certification\"\u003e\u003cspan style=\"color: rgb(255, 42, 0);\"\u003e Quality Certificate - ISO9001 (pdf)\u003c\/span\u003e\u003c\/span\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003cbr\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/AN015_Using_a_pump_to_sample_gas_Application_Note_Rev_1.1.pdf?v=1651156092\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/CO2METER_PDF.png?1094\" alt=\"\"\u003e\u003cstrong\u003e\u003cspan style=\"color: red;\"\u003e GSS Guide for Sample Draw Pumps (pdf)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"\/pages\/co2meter-resources\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/CO2METER_PDF.png?1094\" alt=\"\"\u003e\u003cstrong\u003e\u003cspan style=\"color: red;\"\u003e Additional Application Notes\u003c\/span\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"software\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv class=\"accessories\"\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/www.co2meter.com\/products\/gas-sensor-development-kit\" title=\"CO2Meter Gas Sensor Development Kit\"\u003e\u003cstrong\u003eGas Sensor Development Kit\u003c\/strong\u003e (CM-200)\u003c\/a\u003e- designed to provide customers with an easy drop-in solution. Includes our free \u003ca title=\"Gaslab data logging software\" href=\"https:\/\/www.co2meter.com\/pages\/downloads\"\u003eGaslab data logging software\u003c\/a\u003e. Sensor sold separately.\u003c\/p\u003e\n\u003cp\u003e\u003ca title=\"micro-pump kit\" href=\"\/products\/gas-sensor-micro-pump\"\u003e\u003cstrong\u003eMicro-Pump Kit\u003c\/strong\u003e\u003c\/a\u003e\u003cspan\u003e \u003c\/span\u003eincludes all the tools you need to utilize the tube-cap adapters as part of a sampling sensor system.\u003c\/p\u003e\n\u003cp\u003e\u003ca title=\"nafion tubing\" href=\"\/products\/nafion-gas-sample-drying-tubing\"\u003e\u003cstrong\u003eNafion Tubing\u003c\/strong\u003e\u003c\/a\u003e is a highly selective, semi-permeable membrane to water vapor. If gases inside Nafion tubing are wetter than gases surrounding the tubing, drying will occur. If the surrounding gases are wetter, humidification will occur.\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"\/products\/gas-sampling-pump\"\u003e\u003cstrong\u003eMicro Gas Sampling Pumps\u003c\/strong\u003e\u003c\/a\u003e provides a constant flow of air across the sensor with a tube cap - perfect for bench-top testing of sensors for closed-loop sampling applications.\u003c\/p\u003e\n\u003c\/div\u003e","brand":"GSS","offers":[{"title":"SPRINTIR-R-20: 20% CO2 Sensor only","offer_id":43960917459142,"sku":"SPRINTIR-R-20","price":362.0,"currency_code":"USD","in_stock":true},{"title":"CM-20420: 20% CO2 Sensor w\/ MX Board","offer_id":43960917491910,"sku":"CM-20420","price":527.0,"currency_code":"USD","in_stock":false},{"title":"CM-20421: 20% CO2 Sensor and Development Kit","offer_id":43960917524678,"sku":"CM-20421","price":549.0,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/SPRINTIR-R-20lCO2Meter.jpg?v=1753284094"},{"product_id":"gss-co2meter-cozir-blink-co2-sensor","title":"CozIR®-Blink Sensor","description":"\u003cp\u003eThe \u003cstrong\u003e\u003cspan style=\"color: #115e67;\"\u003eCozIR®-Blink\u003c\/span\u003e \u003c\/strong\u003e(formerly known as the GC-0035) is an ultra low power CO2 sensor that enables customers to reduce power consumption of CO2 measurements to zero.  This allows full control of energy trade-offs for ultra-low power environments and applications.\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eGSS designed this CO2 sensor specifically for low power applications. \u003c\/span\u003e The CO2 module can be power cycled, allowing the user to wake up the unit from a dormant state, take a reading, and then power it down completely again.\u003c\/p\u003e\n\u003cdiv\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMeasures up to 1% CO2 concentration\u003c\/li\u003e\n\u003cli\u003eDigital (UART) and I2C Output\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eExtremely low power and energy consumption (32 mJ per measurement)\u003c\/li\u003e\n\u003cli\u003eIntegrates into smart-home environments, HVAC, Building Automation, Instrumentation, Agriculture, MAP, Automotive, Aerospace, and Safety.\u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eModels\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCOZIR-BLINK\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e–\u003cspan\u003e designed as a solid-state technology that enables best-in-class power consumption, durability, and lifespan.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"specifications\"\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCO2 Measurement: \u003c\/strong\u003ePatented Solid-state NDIR absorption\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSample Method:\u003c\/strong\u003e Solid-state LED NDIR Diffusion\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMeasurement Range:\u003c\/strong\u003e 0-2,000 ppm, 0-5000 ppm, 0-1%\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating Conditions - Temperature: \u003c\/strong\u003e0°C to 50°C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStorage Conditions - Temperature: \u003c\/strong\u003e-40°C to +70°C\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating Conditions - Humidity: \u003c\/strong\u003e0-95% RH, non-condensing\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAccuracy:\u003c\/strong\u003e ±(30ppm, +3% of reading)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eResolution:\u003c\/strong\u003e 1ppm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCalibration:\u003c\/strong\u003e Auto calibration\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnvironmental Compliance\u003c\/strong\u003e: RoHS and REACH\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePressure dependence:\u003c\/strong\u003e 0.15% of reading per mbar in normal atmospheric conditions\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating pressure range:\u003c\/strong\u003e 500mbar – 10 bar\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eResponse time:\u003c\/strong\u003e \u0026lt;30 seconds (diffusion limited)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTime to 1st Reading: \u003c\/strong\u003e\u0026lt;1.2 Seconds\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSensor Life Expectancy\u003c\/strong\u003e\u003cspan\u003e\u003cstrong\u003e:\u003c\/strong\u003e \u003c\/span\u003e\u0026gt;15 years\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDimensions: \u003c\/strong\u003e31mm x 19.5mm x 12.7mm, 5g (Pinned) \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eElectrical\/Mechanical\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Input:\u003c\/strong\u003e 3.25 to 5.5V (3.3V recommended)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Consumption:\u003c\/strong\u003e \u0026lt;3.5mW @ 3.3V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnector:\u003c\/strong\u003e 2 x 6-way 1.27mm header\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCommunication:\u003c\/strong\u003e UART\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eWarranty\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e90 days - See \u003ca title=\"CO2Meter Terms and Conditions\" href=\"https:\/\/www.co2meter.com\/pages\/terms-conditions\"\u003e\u003cstrong\u003eCO2Meter Terms and Conditions.\u003c\/strong\u003e\u003c\/a\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"documents\"\u003e\n\u003ch3\u003eDocuments\u003c\/h3\u003e\n\u003cp\u003e\u003ca title=\"CozIR-Blink_DataSheet\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/Datasheet_COZIR_Blink_CO2Meter_4_15_1_-compressed_1.pdf\"\u003e\u003cimg alt=\"Cozir  Blink Datasheet\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/CO2METER_PDF.png?1093\"\u003e\u003cstrong\u003e\u003cspan style=\"color: red;\"\u003e Data Sheet (pdf) \u003c\/span\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/www.gassensing.co.uk\/wp-content\/uploads\/2023\/05\/CozIR-Blink-DataSheet-Rev-4.25_3.pdf\"\u003e\u003cimg alt=\"User Guide\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/CO2METER_PDF.png?1093\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/CozIR-Blink_DataSheet_Rev_4.21_98be7b60-ac50-4074-bb20-6c1d8cd721c4.pdf\" title=\"GSS CO2Meter CoZir-Blink Manual\" target=\"_blank\"\u003e\u003cstrong\u003e\u003cspan style=\"color: red;\"\u003e User Guide (pdf)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan style=\"color: red;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/GSS-Certification.pdf?v=1650749519\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/CO2METER_PDF.png?1094\" alt=\"GSS Quality Certification\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/2027_FM_ISO_Certificate.pdf?v=1742814585\" title=\"ISO Certificate of Conformity\"\u003e Quality Certificate - ISO9001 (pdf)\u003c\/a\u003e\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/Mechanical_Diagram_-_CozIR-Blink-CO2Meter.pdf\"\u003e\u003cimg alt=\"CozIR Blink Dimensional Drawings\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/CO2METER_PDF.png?1093\"\u003e\u003cstrong\u003e\u003cspan style=\"color: red;\"\u003e Dimensional Drawings (pdf)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"\/pages\/co2meter-resources\"\u003eView More GSS CO2 Sensor Application Notes\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e","brand":"GSS","offers":[{"title":"COZIR-BLINK-5000: CozIR®-Blink Sensor","offer_id":30298281738358,"sku":"COZIR-BLINK","price":90.19,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/COZIR-BLINK-5000-CO2Meter.jpg?v=1753284089"},{"product_id":"030-8-0011-k30-extended-range","title":"030-8-0011 K30 Extended Range","description":"\u003cp\u003eThe \u003cstrong\u003eK30 Extended Range Sensor (030-8-0011) \u003c\/strong\u003eis intended to be built into devices that require up to 5,000 ppm CO2 monitoring or measurement.\u003c\/p\u003e\n\u003cp\u003eIt is an accurate, proven, low-cost solution for OEMs who want to integrate CO2 sensing into their products, research, or studies.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eSimple to install, pre-calibrated and ready-to-use\u003c\/li\u003e\n\u003cli\u003eProven reliability, low cost\u003c\/li\u003e\n\u003cli\u003eMaintenance free in normal applications\u003c\/li\u003e\n\u003cli\u003eFlexible analog and digital outputs\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eModels\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eK30 Extended Range CO2 Sensor\u003c\/strong\u003e (030-8-0011) - For integration into high-volume OEM products.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSensor Development Kit\u003c\/strong\u003e (CM-200) - Easy to use, simply plug the sensor into the PCB and plug it into your PC via USB. Use our free \u003ca title=\"Gaslab software\" href=\"\/pages\/downloads\"\u003eGasLab® software\u003c\/a\u003e to measure and graph carbon dioxide or use our \u003ca rel=\"noopener\" title=\"Source code on Github\" href=\"https:\/\/github.com\/co2meter-org\/ExampleCode\" target=\"_blank\"\u003elibrary of source code on Github\u003c\/a\u003e to build your own application or for OEM batch testing\/configuration. Order sensors on this page, then \u003ca title=\"Gas Sensor Development Kit\" href=\"https:\/\/www.co2meter.com\/products\/gas-sensor-development-kit\"\u003eorder the Devkit here\u003c\/a\u003e.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan style=\"color: #286adc;\" data-mce-style=\"color: #286adc;\"\u003e\u003cstrong\u003eWe recommend that all first time users purchase both this sensor and the CM-200 Development Kit for fastest and easiest results.\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cdiv class=\"specifications\"\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eCO2 Measurement: non-dispersive infrared (NDIR)\u003c\/li\u003e\n\u003cli\u003eMeasurement Range: 0 – 5,000ppm, Up to 10,000 ppm extended range\u003c\/li\u003e\n\u003cli\u003eRate of Measurement: 0.5 Hz\u003c\/li\u003e\n\u003cli\u003eResponse Time Diffusion: 20 seconds\u003c\/li\u003e\n\u003cli\u003eWarm-up Time: \u0026lt; 1 min. \u003c\/li\u003e\n\u003cli\u003eOutputs. 2 analog, 2 digital\u003c\/li\u003e\n\u003cli\u003eScalable Analog voltage outputs\u003c\/li\u003e\n\u003cli\u003eOperating Temperature:\u003c\/li\u003e\n\u003cli\u003eOperating Humidity:\u003c\/li\u003e\n\u003cli\u003eRepeatability: ± 20 ppm ± 1 % of measured value within specifications\u003c\/li\u003e\n\u003cli\u003eAccuracy: ± 30 ppm ± 3 % of measured value within specifications\u003c\/li\u003e\n\u003cli\u003eMaintenance Interval: no maintenance required\u003c\/li\u003e\n\u003cli\u003eSelf-Diagnostics: complete function check at startup\u003c\/li\u003e\n\u003cli\u003eABC (Automatic Background Calibration) enabled unless specified\u003c\/li\u003e\n\u003cli\u003eDimensions: 51 mm x 58 mm x 12 mm\u003c\/li\u003e\n\u003cli\u003eSensor Life Expectancy: \u0026gt; 15 years\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eConforms with Standards\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eEmission: EN61000-6-3:2001\u003c\/li\u003e\n\u003cli\u003eImmunity: EN61000-6-2:2001\u003c\/li\u003e\n\u003cli\u003eRoHS directive 2002\/95\/EG\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eElectrical \/ Mechanical\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003ePower Input: 4.5-140 VD C maximum rating (without reverse polarity protection)\u003c\/li\u003e\n\u003cli\u003eCurrent Consumption: 40 mA average,\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eWarranty\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e90 days - See\u003ca title=\"Terms and Conditions\" href=\"https:\/\/www.co2meter.com\/pages\/terms-conditions\"\u003e CO2Meter Terms and Conditions\u003c\/a\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"documents\"\u003e\n\u003cdiv class=\"data-sheets\"\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/rmtplusstoragesenseair.blob.core.windows.net\/docs\/publicerat\/PSH0131.pdf\" data-mce-href=\"https:\/\/rmtplusstoragesenseair.blob.core.windows.net\/docs\/publicerat\/PSH0131.pdf\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/CO2METER_PDF.png?1094\" alt=\"Datasheet\" data-mce-src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/CO2METER_PDF.png?1094\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/rmtplusstoragesenseair.blob.core.windows.net\/docs\/publicerat\/PSH0131.pdf\" data-mce-href=\"https:\/\/rmtplusstoragesenseair.blob.core.windows.net\/docs\/publicerat\/PSH0131.pdf\"\u003e\u003cstrong\u003e\u003cspan style=\"color: red;\" data-mce-style=\"color: red;\"\u003e Data Sheet (pdf)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/DS-SE-0018-K30-CO2-Sensor.pdf?v=1653003999\" data-mce-href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/DS-SE-0018-K30-CO2-Sensor.pdf?v=1653003999\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/CO2METER_PDF.png?1094\" alt=\"Datasheet\" data-mce-src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/CO2METER_PDF.png?1094\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/DS-SenseAir-K30-CO2-Sensor-Revised-2023.pdf?v=1692893893\" data-mce-href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/DS-SenseAir-K30-CO2-Sensor-Revised-2023.pdf?v=1692893893\"\u003e\u003cstrong\u003e\u003cspan style=\"color: red;\" data-mce-style=\"color: red;\"\u003e K30 Terminal Descriptions and Configurations (pdf)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/Drawing_K30_K33_Revised_2023.pdf?v=1692893892\" data-mce-href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/Drawing_K30_K33_Revised_2023.pdf?v=1692893892\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/CO2METER_PDF.png?1094\" alt=\"CO2 sensor drawing\" data-mce-src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/CO2METER_PDF.png?1094\"\u003e\u003cstrong\u003e\u003cspan style=\"color: red;\" data-mce-style=\"color: red;\"\u003e Dimensional Drawings (pdf)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"http:\/\/\/co2meters.com\/Documentation\/Other\/SenseairISO.pdf\" data-mce-href=\"http:\/\/\/co2meters.com\/Documentation\/Other\/SenseairISO.pdf\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/CO2METER_PDF.png?1093\" alt=\"Senseair ISO Certification\" data-mce-src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/CO2METER_PDF.png?1093\"\u003e\u003cstrong\u003e\u003cspan style=\"color: red;\" data-mce-style=\"color: red;\"\u003e Senseair ISO Certification (pdf)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"manuals\"\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/rmtplusstoragesenseair.blob.core.windows.net\/docs\/publicerat\/PSP110.pdf\" data-mce-href=\"https:\/\/rmtplusstoragesenseair.blob.core.windows.net\/docs\/publicerat\/PSP110.pdf\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/CO2METER_PDF.png?1094\" alt=\"Manual\" data-mce-src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/CO2METER_PDF.png?1094\"\u003e\u003cstrong\u003e\u003cspan style=\"color: red;\" data-mce-style=\"color: red;\"\u003e K30 1% Manual (pdf)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/AN145-sensor-development-kit-quick-start-guide.pdf?v=1650749355\" data-mce-href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/AN145-sensor-development-kit-quick-start-guide.pdf?v=1650749355\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/CO2METER_PDF.png?1094\" alt=\"Quick Start Guide\" data-mce-src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/CO2METER_PDF.png?1094\"\u003e\u003cstrong\u003e\u003cspan style=\"color: red;\" data-mce-style=\"color: red;\"\u003e Devkit Quick Start Guide (pdf)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/SenseAirCommGuide.zip?v=1638914112\" data-mce-href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/SenseAirCommGuide.zip?v=1638914112\"\u003e\u003cimg src=\"\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/assets\/zip.gif\" alt=\"\" data-mce-src=\"\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/assets\/zip.gif\"\u003e\u003cstrong\u003e\u003cspan style=\"color: red;\" data-mce-style=\"color: red;\"\u003e I2C \u0026amp; Modbus Communication Manuals (zip)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/AN_SE_0020_Sensor_Calibration_Procedure_2023.pdf?v=1692893892\" data-mce-href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/AN_SE_0020_Sensor_Calibration_Procedure_2023.pdf?v=1692893892\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/CO2METER_PDF.png?1094\" alt=\"\" data-mce-src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/CO2METER_PDF.png?1094\"\u003e\u003cstrong\u003e\u003cspan style=\"color: red;\" data-mce-style=\"color: red;\"\u003e Sensor Calibration Procedure (pdf)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"technical-documents\"\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/rmtplusstoragesenseair.blob.core.windows.net\/docs\/Dev\/publicerat\/TDE2336.pdf\" data-mce-href=\"https:\/\/rmtplusstoragesenseair.blob.core.windows.net\/docs\/Dev\/publicerat\/TDE2336.pdf\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/CO2METER_PDF.png?1094\" alt=\"\" data-mce-src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/CO2METER_PDF.png?1094\"\u003e\u003cstrong\u003e\u003cspan style=\"color: red;\" data-mce-style=\"color: red;\"\u003e Modbus Documentation Flexibility Counts (pdf)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/rmtplusstoragesenseair.blob.core.windows.net\/docs\/Dev\/publicerat\/TDE4700.pdf\" data-mce-href=\"https:\/\/rmtplusstoragesenseair.blob.core.windows.net\/docs\/Dev\/publicerat\/TDE4700.pdf\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/CO2METER_PDF.png?1094\" alt=\"\" data-mce-src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/CO2METER_PDF.png?1094\"\u003e\u003cstrong\u003e\u003cspan style=\"color: red;\" data-mce-style=\"color: red;\"\u003e I2C Communication Guide (pdf)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/AN141-Labview-examples.zip?v=1647477681\" data-mce-href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/AN141-Labview-examples.zip?v=1647477681\"\u003e\u003cimg src=\"\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/assets\/zip.gif\" alt=\"\" data-mce-src=\"\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/assets\/zip.gif\"\u003e\u003cstrong\u003e\u003cspan style=\"color: red;\" data-mce-style=\"color: red;\"\u003e Labview Examples for SenseAir K-30 (zip)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/AN_144_SE_0018_Revised8_CO2Meter.pdf?v=1710164404\" data-mce-href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/AN_144_SE_0018_Revised8_CO2Meter.pdf?v=1710164404\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/CO2METER_PDF.png?1094\" alt=\"\" data-mce-src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/CO2METER_PDF.png?1094\"\u003e\u003cstrong\u003e\u003cspan style=\"color: red;\" data-mce-style=\"color: red;\"\u003e Web Application Using PHP and K30 DevKit (pdf)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/AN137-K30-sensor-raspberry-pi-Revised8.pdf?v=1653006660\" data-mce-href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/AN137-K30-sensor-raspberry-pi-Revised8.pdf?v=1653006660\"\u003e\u003cimg src=\"\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/assets\/zip.gif\" alt=\"\" data-mce-src=\"\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/assets\/zip.gif\"\u003e\u003cstrong\u003e\u003cspan style=\"color: red;\" data-mce-style=\"color: red;\"\u003e Raspberry Pi UART Instructions (pdf)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/AN137-K30-sensor-raspberry-pi.zip?v=1653006700\" data-mce-href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/AN137-K30-sensor-raspberry-pi.zip?v=1653006700\"\u003e\u003cimg src=\"\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/assets\/zip.gif\" alt=\"\" data-mce-src=\"\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/assets\/zip.gif\"\u003e\u003cstrong\u003e\u003cspan style=\"color: red;\" data-mce-style=\"color: red;\"\u003e Raspberry Pi UART Sample Code (zip)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/AN126-K3x-sensor-arduino-uart_2023.pdf?v=1692893893\" data-mce-href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/AN126-K3x-sensor-arduino-uart_2023.pdf?v=1692893893\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/CO2METER_PDF.png?1094\" alt=\"\" data-mce-src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/CO2METER_PDF.png?1094\"\u003e\u003cstrong\u003e\u003cspan style=\"color: red;\" data-mce-style=\"color: red;\"\u003e Arduino UART Instructions (pdf)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/AN126-K3x-sensor-arduino-uart.zip?v=1653006884\" data-mce-href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/AN126-K3x-sensor-arduino-uart.zip?v=1653006884\"\u003e\u003cimg src=\"\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/assets\/zip.gif\" alt=\"\" data-mce-src=\"\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/assets\/zip.gif\"\u003e\u003cstrong\u003e\u003cspan style=\"color: red;\" data-mce-style=\"color: red;\"\u003e Arduino UART Sample Code (zip)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/AN102-K30-Sensor-Arduino-I2C-2023.pdf?v=1692893893\" data-mce-href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/AN102-K30-Sensor-Arduino-I2C-2023.pdf?v=1692893893\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/CO2METER_PDF.png?1094\" alt=\"\" data-mce-src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/CO2METER_PDF.png?1094\"\u003e\u003cstrong\u003e\u003cspan style=\"color: red;\" data-mce-style=\"color: red;\"\u003e Arduino I2C Instructions (pdf)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/AN102-K30-Sensor-Arduino-I2C.zip?v=1653007039\" data-mce-href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/AN102-K30-Sensor-Arduino-I2C.zip?v=1653007039\"\u003e\u003cimg src=\"\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/assets\/zip.gif\" alt=\"\" data-mce-src=\"\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/assets\/zip.gif\"\u003e\u003cstrong\u003e\u003cspan style=\"color: red;\" data-mce-style=\"color: red;\"\u003e Arduino I2C Sample Code (zip)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/AN_144_SE_0018_Revised8_CO2Meter.pdf?v=1710164404\" data-mce-href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/AN_144_SE_0018_Revised8_CO2Meter.pdf?v=1710164404\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/CO2METER_PDF.png?1094\" alt=\"\" data-mce-src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/CO2METER_PDF.png?1094\"\u003e\u003cstrong\u003e\u003cspan style=\"color: red;\" data-mce-style=\"color: red;\"\u003e Troubleshooting Arduino or Raspberry Pi (pdf)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"case-studies\"\u003e\n\u003cp\u003e\u003ca href=\"\/blogs\/news\/6926946-senseair-k30-vaisala-cmm222c-elt-s100-kcd-an100-and-ge-sensing-t6615-sensor-comparison\" title=\"CO2 Sensors compared\" data-mce-href=\"\/blogs\/news\/6926946-senseair-k30-vaisala-cmm222c-elt-s100-kcd-an100-and-ge-sensing-t6615-sensor-comparison\"\u003eSenseAir K30, Vaisala CMM222C, ELT S100, KCD AN100 and GE Sensing T6615 Sensor Comparison\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"\/blogs\/news\/co2-monitoring-and-composting-applications\" title=\"CO2 Monitoring during composting article\" data-mce-href=\"\/blogs\/news\/co2-monitoring-and-composting-applications\"\u003eMonitoring CO2 Levels Critical for Compost Success\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"\/blogs\/news\/10947573-senseairs-co2-sensor-more-accurate-than-ge-other-brands\" title=\"SenseAir CO2 Sensor More Accurate than other brands\" data-mce-href=\"\/blogs\/news\/10947573-senseairs-co2-sensor-more-accurate-than-ge-other-brands\"\u003eStudy Shows SenseAir CO2 Sensor More Accurate than GE, Other Brands\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"\/blogs\/news\/choosing-senseair-k30-co2-sensors\" title=\"Why choose K-30 CO2 Sensor?\" data-mce-href=\"\/blogs\/news\/choosing-senseair-k30-co2-sensors\"\u003eWhitepaper: Why Customers Choose the SenseAir K30 CO2 Sensor\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"\/blogs\/news\/15302513-school-science-fair-project-uses-co2meter-sensors\" title=\"K-30 CO2 sensor school science fair project\" data-mce-href=\"\/blogs\/news\/15302513-school-science-fair-project-uses-co2meter-sensors\"\u003eSchool Science Fair Project Uses SenseAir CO2 Sensors\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"\/blogs\/news\/haney-test-co2-sensor-soil-health\" title=\"Haney test uses CO2 sensor\" data-mce-href=\"\/blogs\/news\/haney-test-co2-sensor-soil-health\"\u003eHaney Test Uses CO2 Sensor to Measure Soil Health\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"\/blogs\/news\/student-science-fair-project-co2-sensor-arduino\" title=\"K30 sensor and Arduino Uno\" data-mce-href=\"\/blogs\/news\/student-science-fair-project-co2-sensor-arduino\"\u003eStudent project combines CO2 sensor, Arduino Uno\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"\/blogs\/news\/senseair-co2-sensor-competes-with-crds-unit-that-costs-thousands-more\" title=\"K30 sensor and CRDS CO2 measurement comparison\" data-mce-href=\"\/blogs\/news\/senseair-co2-sensor-competes-with-crds-unit-that-costs-thousands-more\"\u003eSenseAir CO2 Sensor Competes with CRDS Unit that Costs Thousands More\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"software\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv class=\"accessories\"\u003e\n\u003ch3\u003eAccessories\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/www.co2meter.com\/products\/gas-sensor-development-kit\" title=\"CO2Meter Gas Sensor Development Kit\" data-mce-href=\"https:\/\/www.co2meter.com\/products\/gas-sensor-development-kit\"\u003e\u003cstrong\u003eGas Sensor Development Kit \u003c\/strong\u003e\u003c\/a\u003e- designed to provide customers with an easy drop-in solution. Includes our free \u003ca title=\"Gaslab data logging software\" href=\"https:\/\/www.co2meter.com\/pages\/downloads\" data-mce-href=\"https:\/\/www.co2meter.com\/pages\/downloads\"\u003eGaslab data logging software\u003c\/a\u003e. Sensor sold separately.\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"\/products\/sensor-flow-through-director\" title=\"CO2Meter Sensor Tube Cap Adapter\" data-mce-href=\"\/products\/sensor-flow-through-director\"\u003e\u003cstrong\u003eTube Cap Adapter\u003c\/strong\u003e\u003c\/a\u003e changes the sensor from reading CO2 in the air to a sample draw sensor. Use with a pump, tubing and filters to read CO2 levels in enclosed containers\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"\/products\/gas-sensor-micro-pump\" data-mce-href=\"\/products\/gas-sensor-micro-pump\"\u003e\u003cstrong\u003eSample Draw Pump Kit\u003c\/strong\u003e\u003c\/a\u003e includes all the components you need with a sample draw sensor.\u003c\/li\u003e\n\u003cli\u003e\n\u003ca title=\"View the Probe Enclosure for Development Kits\" href=\"\/products\/probe-enclosure-development-kit\" data-mce-href=\"\/products\/probe-enclosure-development-kit\"\u003e\u003cstrong\u003eProbe Enclosure\u003c\/strong\u003e\u003c\/a\u003e. Includes hydrophobic filters, protects the sensor when used in hostile environments.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cp\u003e\u003cspan style=\"color: #ffffff;\" data-mce-style=\"color: #ffffff;\"\u003ek30 k-30 SE-0018 SE0018 SE018 SE18 Senseair SenseAire\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/div\u003e","brand":"Senseair","offers":[{"title":"Default Title","offer_id":42832600334534,"sku":"030-8-0011","price":78.0,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/030-8-0011.jpg?v=1753284024"},{"product_id":"006-1-0100-senseair-sunlight-co2-sensor","title":"006-1-0100 Senseair Sunlight CO2 Sensor","description":"\u003cp\u003eThe \u003cspan style=\"text-decoration: underline;\" data-mce-style=\"text-decoration: underline;\"\u003e\u003cstrong\u003eSenseair Sunlight CO2 Sensor (006-1-0100)\u003c\/strong\u003e\u003c\/span\u003e is a a module that is designed for power efficiency and optimal for battery and wireless applications.\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"font-size: 0.875rem;\" data-mce-style=\"font-size: 0.875rem;\"\u003eAny application with a tough environment or in environments with explosion risk is benefited by the solid-state design. It is also the first NDIR sensor with LED technology that truly saves power while maintaining a high precision.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\n\u003cspan style=\"font-size: 0.875rem;\" data-mce-style=\"font-size: 0.875rem;\"\u003e\u003c\/span\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eExtremely power efficient\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eMiniature size\u003c\/li\u003e\n\u003cli\u003eSelf Correcting\u003c\/li\u003e\n\u003cli\u003eHigh Precision\u003c\/li\u003e\n\u003cli\u003eLED technology\u003c\/li\u003e\n\u003cli\u003eCompliant with ANSI\/ASHRAE Standard 62.1-2022\u003c\/li\u003e\n\u003cli\u003eCompliant with Standard RESET grad B\u003c\/li\u003e\n\u003cli\u003eCompliant with WELL Building Standard (WELL v2)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eModels\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e006-1-0100 Senseair Sunlight CO2 Sensor -\u003c\/strong\u003e designed for optimal use in battery and wireless applications. \u003ca href=\"\/pages\/rfq\" title=\"request for quote\"\u003eContact us directly\u003c\/a\u003e for wholesale pricing on large quantities of this sensor.\u003c\/p\u003e\n\u003ch3\u003e\n\u003cstrong\u003e\u003c\/strong\u003eSpecifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMeasurement Gas: \u003cspan data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\" dir=\"ltr\" class=\"ui-provider ec bqc bqd bqe bqf bqg bqh bqi bqj bqk bql bqm bqn bqo bqp bqq bqr bqs bqt bqu bqv bqw bqx bqy bqz bra brb brc brd bre brf brg brh bri brj\"\u003eCarbon Dioxide\u003c\/span\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003eOperating Principle: Non-dispersive infrared (NDIR)\u003c\/li\u003e\n\u003cli\u003eMeasurement Range: 400-5,000ppm. Extended range 10,000ppm.\u003c\/li\u003e\n\u003cli\u003eAccuracy (CO2): \u003cspan data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\" class=\"ui-provider ec bqc bqd bqe bqf bqg bqh bqi bqj bqk bql bqm bqn bqo bqp bqq bqr bqs bqt bqu bqv bqw bqx bqy bqz bra brb brc brd bre brf brg brh bri brj\" dir=\"ltr\"\u003e±50ppm ±3% of reading, extended range ±10% of reading\u003c\/span\u003e\u003c\/span\u003e\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eAverage current: 30µA or lower\u003c\/li\u003e\n\u003cli\u003ePeak current: \u0026lt;80 mA\u003c\/li\u003e\n\u003cli\u003eSteady state current during sampling: 50 mA\u003c\/li\u003e\n\u003cli\u003eMeasurement period: default: 16s, 8 samples (adjustable host)\u003c\/li\u003e\n\u003cli\u003eOperating Range: 0\u003cspan data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\" class=\"ui-provider ec bqc bqd bqe bqf bqg bqh bqi bqj bqk bql bqm bqn bqo bqp bqq bqr bqs bqt bqu bqv bqw bqx bqy bqz bra brb brc brd bre brf brg brh bri brj\" dir=\"ltr\"\u003e-50°C, 0-85% RH \u003c\/span\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003eMaintenance: Periodic Zero Calibration or ABC Calibration\u003c\/li\u003e\n\u003cli\u003ePower Supply: 3.05-5.5 V DC\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eStorage Temperature: \u003cspan data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\" class=\"ui-provider ec bqc bqd bqe bqf bqg bqh bqi bqj bqk bql bqm bqn bqo bqp bqq bqr bqs bqt bqu bqv bqw bqx bqy bqz bra brb brc brd bre brf brg brh bri brj\" dir=\"ltr\"\u003e-40 – 85°C\u003c\/span\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003eDimensions: 34 x 21 x 12 mm, max\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eLife expectancy: \u0026gt;15 years \u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eCommunication Interface: UART, I2C\u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eWarranty\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e90 days - See CO2Meter Terms and Conditions.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv class=\"documents\"\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/rmtplusstoragesenseair.blob.core.windows.net\/docs\/Dev\/publicerat\/PSH12929.pdf\"\u003e\u003cimg alt=\"Sunlight Datasheet\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/CO2METER_PDF.png?1094\"\u003e\u003cstrong\u003e\u003cspan style=\"color: red;\" data-mce-style=\"color: red;\"\u003e Data Sheet (pdf)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/rmtplusstoragesenseair.blob.core.windows.net\/docs\/Dev\/publicerat\/PSP12930.pdf\"\u003e\u003cimg alt=\"Sunlight Manual\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/CO2METER_PDF.png?1094\"\u003e\u003cstrong\u003e\u003cspan style=\"color: red;\" data-mce-style=\"color: red;\"\u003e Manual (pdf)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/rmtplusstoragesenseair.blob.core.windows.net\/docs\/Dev\/publicerat\/ANO4947.pdf\"\u003e\u003cimg alt=\"Handling Manual\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/CO2METER_PDF.png?1094\"\u003e\u003cstrong\u003e\u003cspan style=\"color: red;\" data-mce-style=\"color: red;\"\u003e Handling Manual (pdf)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/rmtplusstoragesenseair.blob.core.windows.net\/docs\/Dev\/publicerat\/TDE5514.pdf\"\u003e\u003cimg alt=\"Modbus Guide\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/CO2METER_PDF.png?1094\"\u003e\u003cstrong\u003e\u003cspan style=\"color: red;\" data-mce-style=\"color: red;\"\u003eModbus Guide(pdf)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/rmtplusstoragesenseair.blob.core.windows.net\/docs\/Dev\/publicerat\/TDE5531.pdf\"\u003e\u003cimg alt=\"I2C Protocol\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/CO2METER_PDF.png?1094\"\u003e\u003cstrong\u003e\u003cspan style=\"color: red;\" data-mce-style=\"color: red;\"\u003e I2C Protocol Guide (pdf)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/SenseairISO.pdf?v=1613679881\"\u003e\u003cimg alt=\"Senseair ISO Certification\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/CO2METER_PDF.png?1093\"\u003e\u003cstrong\u003e\u003cspan style=\"color: red;\" data-mce-style=\"color: red;\"\u003e Senseair ISO Certification (pdf)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e","brand":"CO2 Meter","offers":[{"title":"Default Title","offer_id":42836241023174,"sku":"006-1-0100","price":39.0,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/006-1-0100.jpg?v=1753284020"},{"product_id":"030-8-0016-k30-1-co2-sensor","title":"030-8-0016 K30 1% CO2 Sensor","description":"\u003cp\u003eThe \u003cstrong\u003eK30 1% CO2 Sensor \u003c\/strong\u003e(030-8-0016) is intended to be used to monitor up to 1% CO2 where the levels are constantly higher than normal but still within safety levels.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eThis sensor comes with the Automatic Background Calibration turned off.\u003c\/strong\u003e ABC only works when the sensor can regularly detect fresh air. If CO2 levels are always higher than outdoor air, this sensor will not drift. However, periodic manual calibration will be required.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eSimple to install, pre-calibrated and ready-to-use\u003c\/li\u003e\n\u003cli\u003eProven reliability, low cost\u003c\/li\u003e\n\u003cli\u003eMaintenance free in normal applications\u003c\/li\u003e\n\u003cli\u003eFlexible analog and digital outputs\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eModels\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e030-8-0016 - K30 1% CO2 Sensor Only\u003c\/strong\u003e - For integration into high-volume OEM products. Automatic Baseline Calibration (ABC) turned off.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSensor Development Kit\u003c\/strong\u003e (CM-200) - Easy to use, simply plug the sensor into the PCB and plug it into your PC via USB. Use our free \u003ca title=\"Gaslab software\" href=\"\/pages\/downloads\"\u003eGasLab® software\u003c\/a\u003e to measure and graph carbon dioxide or use our \u003ca rel=\"noopener\" title=\"Source code on Github\" href=\"https:\/\/github.com\/co2meter-org\/ExampleCode\" target=\"_blank\"\u003elibrary of source code on Github\u003c\/a\u003e to build your own application or for OEM batch testing\/configuration. Order sensors on this page, then \u003ca title=\"Gas Sensor Development Kit\" href=\"https:\/\/www.co2meter.com\/products\/gas-sensor-development-kit\"\u003eorder the Devkit here\u003c\/a\u003e.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan style=\"color: #286adc;\"\u003e\u003cstrong\u003eWe recommend that all first time users purchase both this sensor and the CM-200 Development Kit for fastest and easiest results.\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cdiv class=\"specifications\"\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eCO2 Measurement: non-dispersive infrared (NDIR)\u003c\/li\u003e\n\u003cli\u003eMeasurement Range: 0 – 10,000 ppm (0-5,000 ppm within specifications)\u003c\/li\u003e\n\u003cli\u003eRate of Measurement: every 2 seconds\u003c\/li\u003e\n\u003cli\u003eResponse Time Diffusion: 20 seconds\u003c\/li\u003e\n\u003cli\u003eResponse Time Sample Draw: 2 seconds @ .5 l\/min tube gas flow\u003c\/li\u003e\n\u003cli\u003eWarm-up Time: \u0026lt; 1 min. (@ full specs \u0026lt; 15 min)\u003c\/li\u003e\n\u003cli\u003eOutputs. 2 analog, 2 digital\u003c\/li\u003e\n\u003cli\u003eScalable Analog voltage outputs\u003c\/li\u003e\n\u003cli\u003eEach digital output has threshold and hysteresis\u003c\/li\u003e\n\u003cli\u003eProgrammable Range: 0-10,000 ppm (custom configuration required)\u003c\/li\u003e\n\u003cli\u003eRepeatability: ± 20 ppm ± 1 % of measured value within specifications\u003c\/li\u003e\n\u003cli\u003eAccuracy: ± 30 ppm ± 3 % of measured value within specifications\u003c\/li\u003e\n\u003cli\u003eMaintenance Interval: no maintenance required\u003c\/li\u003e\n\u003cli\u003eSelf-Diagnostics: complete function check at startup\u003c\/li\u003e\n\u003cli\u003eABC (Automatic Background Calibration) enabled unless specified\u003c\/li\u003e\n\u003cli\u003eDimensions: 51 mm x 58 mm x 12 mm\u003c\/li\u003e\n\u003cli\u003eSensor Life Expectancy: \u0026gt; 15 years\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eConforms with Standards\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eEmission: EN61000-6-3:2001\u003c\/li\u003e\n\u003cli\u003eImmunity: EN61000-6-2:2001\u003c\/li\u003e\n\u003cli\u003eRoHS directive 2002\/95\/EG\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eElectrical \/ Mechanical\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eDimensions: 51 × 57 × 14 mm (Length x Width x approximate Height)\u003c\/li\u003e\n\u003cli\u003ePower Input: 5.5-14 VDC, stabilized to within 10% (external protection circuits required)\u003c\/li\u003e\n\u003cli\u003eCurrent Consumption: 40 mA average\u003c\/li\u003e\n\u003cli\u003eSampling Method: diffusion (tube cap optional)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eWarranty\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e90 days - See\u003ca title=\"Terms and Conditions\" href=\"https:\/\/www.co2meter.com\/pages\/terms-conditions\"\u003e CO2Meter Terms and Conditions.\u003c\/a\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"documents\"\u003e\n\u003cdiv class=\"data-sheets\"\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/rmtplusstoragesenseair.blob.core.windows.net\/docs\/publicerat\/PSH0131.pdf\"\u003e\u003cimg alt=\"Datasheet\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/CO2METER_PDF.png?1094\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/rmtplusstoragesenseair.blob.core.windows.net\/docs\/publicerat\/PSH0131.pdf\"\u003e\u003cstrong\u003e\u003cspan style=\"color: red;\"\u003e Data Sheet (pdf)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/DS-SE-0018-K30-CO2-Sensor.pdf?v=1653003999\"\u003e\u003cimg alt=\"Datasheet\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/CO2METER_PDF.png?1094\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/DS-SenseAir-K30-CO2-Sensor-Revised-2023.pdf?v=1692893893\"\u003e\u003cstrong\u003e\u003cspan style=\"color: red;\"\u003e K30 Terminal Descriptions and Configurations (pdf)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/Drawing_K30_K33_Revised_2023.pdf?v=1692893892\"\u003e\u003cimg alt=\"CO2 sensor drawing\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/CO2METER_PDF.png?1094\"\u003e\u003cstrong\u003e\u003cspan style=\"color: red;\"\u003e Dimensional Drawings (pdf)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"http:\/\/\/co2meters.com\/Documentation\/Other\/SenseairISO.pdf\"\u003e\u003cimg alt=\"Senseair ISO Certification\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/CO2METER_PDF.png?1093\"\u003e\u003cstrong\u003e\u003cspan style=\"color: red;\"\u003e Senseair ISO Certification (pdf)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"manuals\"\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/rmtplusstoragesenseair.blob.core.windows.net\/docs\/publicerat\/PSP110.pdf\"\u003e\u003cimg alt=\"Manual\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/CO2METER_PDF.png?1094\"\u003e\u003cstrong\u003e\u003cspan style=\"color: red;\"\u003e K30 1% Manual (pdf)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/SenseAirCommGuide.zip?v=1638914112\"\u003e\u003cimg alt=\"\"\u003e\u003cstrong\u003e\u003cspan style=\"color: red;\"\u003e I2C \u0026amp; Modbus Communication Manuals (zip)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/AN_SE_0020_Sensor_Calibration_Procedure_2023.pdf?v=1692893892\"\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/CO2METER_PDF.png?1094\"\u003e\u003cstrong\u003e\u003cspan style=\"color: red;\"\u003e Sensor Calibration Procedure (pdf)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"technical-documents\"\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/rmtplusstoragesenseair.blob.core.windows.net\/docs\/Dev\/publicerat\/TDE2336.pdf\"\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/CO2METER_PDF.png?1094\"\u003e\u003cstrong\u003e\u003cspan style=\"color: red;\"\u003e Modbus Documentation Flexibility Counts (pdf)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/rmtplusstoragesenseair.blob.core.windows.net\/docs\/Dev\/publicerat\/TDE4700.pdf\"\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/CO2METER_PDF.png?1094\"\u003e\u003cstrong\u003e\u003cspan style=\"color: red;\"\u003e I2C Communication Guide (pdf)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/AN141-Labview-examples.zip?v=1647477681\"\u003e\u003cimg alt=\"\"\u003e\u003cstrong\u003e\u003cspan style=\"color: red;\"\u003e Labview Examples for SenseAir K-30 (zip)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/AN_144_SE_0018_Revised8_CO2Meter.pdf?v=1710164404\"\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/CO2METER_PDF.png?1094\"\u003e\u003cstrong\u003e\u003cspan style=\"color: red;\"\u003e Web Application Using PHP and K30 DevKit (pdf)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/AN137-K30-sensor-raspberry-pi-Revised8.pdf?v=1653006660\"\u003e\u003cimg alt=\"\"\u003e\u003cstrong\u003e\u003cspan style=\"color: red;\"\u003e Raspberry Pi UART Instructions (pdf)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/AN137-K30-sensor-raspberry-pi.zip?v=1653006700\"\u003e\u003cimg alt=\"\"\u003e\u003cstrong\u003e\u003cspan style=\"color: red;\"\u003e Raspberry Pi UART Sample Code (zip)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/AN126-K3x-sensor-arduino-uart_2023.pdf?v=1692893893\"\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/CO2METER_PDF.png?1094\"\u003e\u003cstrong\u003e\u003cspan style=\"color: red;\"\u003e Arduino UART Instructions (pdf)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/AN126-K3x-sensor-arduino-uart.zip?v=1653006884\"\u003e\u003cimg alt=\"\"\u003e\u003cstrong\u003e\u003cspan style=\"color: red;\"\u003e Arduino UART Sample Code (zip)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/AN102-K30-Sensor-Arduino-I2C-2023.pdf?v=1692893893\"\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/CO2METER_PDF.png?1094\"\u003e\u003cstrong\u003e\u003cspan style=\"color: red;\"\u003e Arduino I2C Instructions (pdf)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/AN102-K30-Sensor-Arduino-I2C.zip?v=1653007039\"\u003e\u003cimg alt=\"\"\u003e\u003cstrong\u003e\u003cspan style=\"color: red;\"\u003e Arduino I2C Sample Code (zip)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/AN_144_SE_0018_Revised8_CO2Meter.pdf?v=1710164404\"\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/CO2METER_PDF.png?1094\"\u003e\u003cstrong\u003e\u003cspan style=\"color: red;\"\u003e Troubleshooting Arduino or Raspberry Pi (pdf)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"case-studies\"\u003e\n\u003cp\u003e\u003ca title=\"CO2 Sensors compared\" href=\"\/blogs\/news\/6926946-senseair-k30-vaisala-cmm222c-elt-s100-kcd-an100-and-ge-sensing-t6615-sensor-comparison\"\u003eSenseAir K30, Vaisala CMM222C, ELT S100, KCD AN100 and GE Sensing T6615 Sensor Comparison\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca title=\"CO2 Monitoring during composting article\" href=\"\/blogs\/news\/co2-monitoring-and-composting-applications\"\u003eMonitoring CO2 Levels Critical for Compost Success\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca title=\"SenseAir CO2 Sensor More Accurate than other brands\" href=\"\/blogs\/news\/10947573-senseairs-co2-sensor-more-accurate-than-ge-other-brands\"\u003eStudy Shows SenseAir CO2 Sensor More Accurate than GE, Other Brands\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca title=\"Why choose K-30 CO2 Sensor?\" href=\"\/blogs\/news\/choosing-senseair-k30-co2-sensors\"\u003eWhitepaper: Why Customers Choose the SenseAir K30 CO2 Sensor\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca title=\"K-30 CO2 sensor school science fair project\" href=\"\/blogs\/news\/15302513-school-science-fair-project-uses-co2meter-sensors\"\u003eSchool Science Fair Project Uses SenseAir CO2 Sensors\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca title=\"Haney test uses CO2 sensor\" href=\"\/blogs\/news\/haney-test-co2-sensor-soil-health\"\u003eHaney Test Uses CO2 Sensor to Measure Soil Health\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca title=\"K30 sensor and Arduino Uno\" href=\"\/blogs\/news\/student-science-fair-project-co2-sensor-arduino\"\u003eStudent project combines CO2 sensor, Arduino Uno\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca title=\"K30 sensor and CRDS CO2 measurement comparison\" href=\"\/blogs\/news\/senseair-co2-sensor-competes-with-crds-unit-that-costs-thousands-more\"\u003eSenseAir CO2 Sensor Competes with CRDS Unit that Costs Thousands More\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"accessories\"\u003e\n\u003ch3\u003eAccessories\u003c\/h3\u003e\n\u003cul\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003ca title=\"CO2Meter Gas Sensor Development Kit\" href=\"https:\/\/www.co2meter.com\/products\/gas-sensor-development-kit\"\u003e\u003cstrong\u003eGas Sensor Development Kit \u003c\/strong\u003e\u003c\/a\u003e- designed to provide customers with an easy drop-in solution. Includes our free \u003ca href=\"https:\/\/www.co2meter.com\/pages\/downloads\" title=\"Gaslab data logging software\"\u003eGaslab data logging software\u003c\/a\u003e. Sensor sold separately.\u003c\/li\u003e\n\u003cli\u003e\n\u003ca title=\"CO2Meter Sensor Tube Cap Adapter\" href=\"\/products\/sensor-flow-through-director\"\u003e\u003cstrong\u003eTube Cap Adapter\u003c\/strong\u003e\u003c\/a\u003e changes the sensor from reading CO2 in the air to a sample draw sensor. Use with a pump, tubing and filters to read CO2 levels in enclosed containers.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003ca href=\"\/products\/gas-sensor-micro-pump\"\u003eSample Draw Pump Kit\u003c\/a\u003e\u003c\/strong\u003e includes all the components you need with a sample draw sensor to create a closed CO2 measurement system.\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"\/products\/probe-enclosure-development-kit\" title=\"View the Probe Enclosure for Development Kits\"\u003e\u003cstrong\u003eProbe Enclosure\u003c\/strong\u003e\u003c\/a\u003e. Includes hydrophobic filters, protects the sensor when used in hostile environments.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e","brand":"Senseair","offers":[{"title":"Default Title","offer_id":42986726490310,"sku":"030-8-0016","price":99.0,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/030-8-0016.jpg?v=1753284019"},{"product_id":"cm-1106sl-n-low-power-ndir-co2-sensor","title":"CM1106SL-NS Super Low Power NDIR CO2 Sensor","description":"\u003cp\u003eThe \u003cstrong\u003eCM1106SL-N and CM1106-SL-NS Super Low Power NDIR CO2 Sensors\u003c\/strong\u003e are designed for wide use in battery-powered and wireless indoor applications where the need for continuous measurement mode is used.\u003c\/p\u003e\n\u003cp\u003eThese NDIR CO2 sensors are ideal for indoor air quality applications such as demand control ventilation, HVAC and commercial\/residential environments.\u003c\/p\u003e\n\u003cp\u003eBoth pinned and non-pin versions are available depending on your application. Note that the non-pinned version includes I2C output.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eNDIR technology with intellectual property\u003c\/li\u003e\n\u003cli\u003eSuper low power consumption\u003c\/li\u003e\n\u003cli\u003eAdjustable Automatic Background Calibration cycle\u003c\/li\u003e\n\u003cli\u003eTemperature calibration throughout the whole measurement range\u003c\/li\u003e\n\u003cli\u003eWide supply voltage range enabling battery options\u003c\/li\u003e\n\u003cli\u003eMaintenance free - Automatic Baseline Calibration (ABC)\u003c\/li\u003e\n\u003cli\u003eTemperature and Humidity Compensation Throughout the Entire Measurement Range\u003c\/li\u003e\n\u003cli\u003eLong life span (15+ years) \u003c\/li\u003e\n\u003cli\u003eSmall, Compact structure, easy to install\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications:\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eIAQ (Indoor Air Quality)\u003c\/li\u003e\n\u003cli\u003eVentilation Systems\u003c\/li\u003e\n\u003cli\u003eAir Purification\u003c\/li\u003e\n\u003cli\u003eHVAC\u003c\/li\u003e\n\u003cli\u003eDCV (Demand Control Ventilation)\u003c\/li\u003e\n\u003cli\u003eAutomotive\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eModels\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCM1106SL-N Super Low Power NDIR CO2 Sensor \u003c\/strong\u003e- single channel sensor, good accuracy, NDIR super low power, UART output only, with pins.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCM1106SL-NS Low Power NDIR CO2 Sensor \u003c\/strong\u003e-  single channel sensor, good accuracy, NDIR super low power, UART and I2C communications, without pins.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSensor Development Kit\u003c\/strong\u003e (CM-200) - Easy to use, simply plug the sensor into the PCB and plug it into your PC via USB. Use our free \u003ca title=\"Gaslab software\" href=\"\/pages\/downloads\"\u003eGasLab® software\u003c\/a\u003e to measure and graph carbon dioxide or use our \u003ca rel=\"noopener\" title=\"Source code on Github\" href=\"https:\/\/github.com\/co2meter-org\/ExampleCode\" target=\"_blank\"\u003elibrary of source code on Github\u003c\/a\u003e to build your own application or for OEM batch testing\/configuration. Order sensors on this page, then \u003ca title=\"Gas Sensor Development Kit\" href=\"https:\/\/www.co2meter.com\/products\/gas-sensor-development-kit\"\u003eorder the Devkit here\u003c\/a\u003e. Note: pinned sensors may require minor pin clipping.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan style=\"color: #286adc;\"\u003e\u003cstrong\u003eWe recommend that all first time users purchase both this sensor and the CM-200 Development Kit for fastest and easiest results.\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cdiv class=\"specifications\"\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eGas Type: CO2 (Carbon Dioxide)\u003c\/li\u003e\n\u003cli\u003eOperating Principle: Non-dispersive infrared (NDIR)\u003c\/li\u003e\n\u003cli\u003eCO2 Range: 0-5000ppm \u003c\/li\u003e\n\u003cli\u003eCO2 Accuracy: \u003cspan data-mce-fragment=\"1\"\u003e± (50ppm+5% of reading)\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eResponse time: 30s\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003eWorking Temperature: -10\u003cspan\u003e°C~+50°C\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003eWorking Humidity: 0-95%RH (non condensing)\u003c\/li\u003e\n\u003cli\u003eWorking Current: \u003cspan data-mce-fragment=\"1\"\u003e74uA (1 minute as measurement cycle)\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eStorage Temperature: -30°C ~ 70°C \u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eStorage Humidity: 0-95%RH (non-condensing)\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eSampling Frequency: 1s\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eTime to First Reading: ≤30s \u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003ePower Supply: DC3.3V-5.5V\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eRipple Wave: \u0026lt;50mV\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eWorking Current: \u0026lt;50mA @ 1s\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003eSignal output: \u003cspan data-mce-fragment=\"1\"\u003eUART_TTL\u003c\/span\u003e\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eDimensions: 33 x 19.7 x 8.9 mm\u003c\/li\u003e\n\u003cli\u003eWeight: 5g\u003c\/li\u003e\n\u003cli\u003eLifespan: ≥15 years\u003c\/li\u003e\n\u003cli\u003eMaintenance: Maintenance-free for normal indoor application with ABC\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003ch3\u003eWarranty\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e90 days - See\u003ca title=\"Terms and Conditions\" href=\"https:\/\/www.co2meter.com\/pages\/terms-conditions\"\u003e CO2Meter Terms and Conditions.\u003c\/a\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"documents\"\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan style=\"color: red;\" data-mce-style=\"color: red;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/CM1106SL-N_Super_Low_Power_CO2_Sensor_Module_Specification.pdf?v=1719986337\"\u003e\u003cimg alt=\"CM1106SL CO2 Sensor Manual\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/CO2METER_PDF.png?1094\"\u003e CM1106SL-N Manual (pdf)\u003c\/a\u003e\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan style=\"color: red;\" data-mce-style=\"color: red;\"\u003e\u003ca href=\"https:\/\/innovaertech.com\/wp-content\/uploads\/2022\/05\/CM1106SL-NS.pdf\"\u003e\u003cimg alt=\"CM1106SL CO2 Sensor Manual\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/CO2METER_PDF.png?1094\"\u003e CM1106SL-NS Manual (pdf)\u003c\/a\u003e\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"accessories\"\u003e\n\u003ch3\u003eAccessories\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/www.co2meter.com\/products\/gas-sensor-development-kit\" title=\"CO2Meter Gas Sensor Development Kit\" data-mce-href=\"https:\/\/www.co2meter.com\/products\/gas-sensor-development-kit\"\u003eGas Sensor Development Kit \u003c\/a\u003e-  designed to seamlessly integrate with CO2Meter \u003cem\u003eselect\u003cspan\u003e \u003c\/span\u003e\u003c\/em\u003egas sensors and provides customers with built-in pins for an easy drop-in solution. Also includes our free \u003ca href=\"https:\/\/www.co2meter.com\/pages\/downloads\" title=\"Gaslab data logging software\" data-mce-href=\"https:\/\/www.co2meter.com\/pages\/downloads\"\u003eGaslab data logging software\u003c\/a\u003e. \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e","brand":"CO2 Meter","offers":[{"title":"CM1106SL-N CO2 Sensor UART only (with pins)","offer_id":42979205284038,"sku":"CM1106SL-N","price":55.0,"currency_code":"USD","in_stock":true},{"title":"CM1106SL-NS CO2 Sensor UART and I2C (no pins)","offer_id":42979305357510,"sku":"CM1106SL-NS","price":55.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/CM1106SL-N_d4cab3d8-51a6-4b37-8b2a-61c3b0e99330.jpg?v=1753283979"},{"product_id":"am1008-integrated-iaq-co2-pm-sensor","title":"AM1008W CO2, PM, Temp, RH, and VOC Sensor","description":"\u003cp\u003eThe \u003cstrong\u003eAM1008W Integrated IAQ CO2 and PM Sensor\u003c\/strong\u003e measures carbon dioxide, volatile organic compounds, particulate matter, and relative humidity in one device. This is ideal for where the need to monitor indoor air quality can all be done from a single device.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eIntegrated particle, CO2, VOC and RH\u0026amp;T sensors on one board\u003c\/li\u003e\n\u003cli\u003ePM1.0 PM2.5 and PM10 output simultaneously\u003c\/li\u003e\n\u003cli\u003eSmall, compact design\u003c\/li\u003e\n\u003cli\u003eAuto-calibrated NDIR CO2 sensor\u003c\/li\u003e\n\u003cli\u003ePrecise accuracy and robust performance\u003c\/li\u003e\n\u003cli\u003eEMC compliant, strong anti-static ability\u003c\/li\u003e\n\u003cli\u003eAutomatic particulate identification \"switchs\" between algorithms based on environmental needs\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eModels\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eAM1008W - Integrated 5 in 1 IAQ Sensor\u003c\/strong\u003e - measures CO2, VOCs, particulate matter, temperature and relative humidity.\u003c\/p\u003e\n\u003cdiv class=\"specifications\"\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eOperating principle: NDIR, PM, and VOC scattering technology\u003c\/li\u003e\n\u003cli\u003eMeasurement range:  0~5,000 ppm (CO2)\u003c\/li\u003e\n\u003cli\u003eMeasurement range:\u003cspan\u003e \u003c\/span\u003e0~1000μg\/m³ (PM)\u003c\/li\u003e\n\u003cli\u003eMeasurement range: 0~3 level (VOC)\u003c\/li\u003e\n\u003cli\u003eAccuracy for CO2: ±50ppm +5% of reading @-10℃~50℃, 50±10%RH \u003c\/li\u003e\n\u003cli\u003eAccuracy for PM2.5: 0~35μg\/m³, ±5μg\/m³ \u0026gt;35μg\/m³, ±15% of reading @ 0℃~40℃, 50±10%RH\u003c\/li\u003e\n\u003cli\u003eTemperature Accuracy: ±1℃@0℃~40℃, 50±10%RH\u003c\/li\u003e\n\u003cli\u003eRH Accuracy: ±5%RH\u003c\/li\u003e\n\u003cli\u003ePM preheating time: ≤8s\u003c\/li\u003e\n\u003cli\u003eCO2 preheating time: ≤30s\u003c\/li\u003e\n\u003cli\u003eVOC preheating time: ≤180s\u003c\/li\u003e\n\u003cli\u003eData refresh rate: 1s\u003c\/li\u003e\n\u003cli\u003eWorking condition: -10~50℃, 0-95%RH (non condensing)\u003c\/li\u003e\n\u003cli\u003eStorage condition: -30~70℃, 0-95%RH (non condensing)\u003c\/li\u003e\n\u003cli\u003eWorking voltage: DC 5V±0.1V, ripple wave \u0026lt; 50mV \u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eAverage working current: ≤300mA\u003c\/li\u003e\n\u003cli\u003eSignal output: UART_TTL(3.3V TTL)\u003c\/li\u003e\n\u003cli\u003eDimensions: 80 x 50 x 13.6 mm\u003c\/li\u003e\n\u003cli\u003eLifespan: \u0026gt;10 years\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eWarranty\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e90 days - See\u003ca href=\"https:\/\/www.co2meter.com\/pages\/terms-conditions\" title=\"Terms and Conditions\"\u003e CO2Meter Terms and Conditions.\u003c\/a\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"documents\"\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/innovaertech.com\/wp-content\/uploads\/2022\/05\/AM1008.pdf\"\u003e\u003cimg src=\"https:\/\/co2meter.myshopify.com\/images\/admin\/icons\/mimes\/pdf.gif\" alt=\"Manual\"\u003e\u003cstrong\u003e\u003cspan style=\"color: red;\"\u003e Manual (pdf)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"software\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv class=\"accessories\"\u003e\u003cbr\u003e\u003c\/div\u003e","brand":"CO2 Meter","offers":[{"title":"Default Title","offer_id":42979374072006,"sku":"AM1008W","price":121.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/AM1008W.jpg?v=1753283977"},{"product_id":"cm1109-dual-ir-source-ndir-co2-sensor","title":"CM1109 Dual IR Source NDIR CO2 Sensor","description":"\u003cp\u003eThe \u003cspan style=\"color: #115e67;\" data-mce-style=\"color: #115e67;\"\u003e\u003cstrong\u003eCM1109 Dual IR Source NDIR CO2 Sensor\u003c\/strong\u003e \u003c\/span\u003eis designed to measure CO2 for safety, beverage, agriculture, industrial or cold chain storage applications.\u003c\/p\u003e\n\u003cp\u003eThe advantage of a dual source, dual beam sensor is that over time it self-compensates for the influence of temperature and humidity, light source aging and other factors that impact the sensor's accuracy. This results in better stability over its lifetime.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eSuperior Stability \u0026amp; Accuracy\u003c\/li\u003e\n\u003cli\u003eTemperature and Humidity Compensation\u003c\/li\u003e\n\u003cli\u003eHigh Accuracy Supports WELL, RESET, ASHRAE 62.1-2019 Addendum aa \u0026amp; California Title 24 Application\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eIndoor Air Quality (IAQ)\u003c\/li\u003e\n\u003cli\u003eHVAC controller\u003c\/li\u003e\n\u003cli\u003eCentral Air Conditioning\u003c\/li\u003e\n\u003cli\u003eAgriculture\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eModels\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCM1109 - Dual IR Source NDIR CO2 Sensor\u003c\/strong\u003e - designed for long-term stability.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSensor Development Kit\u003c\/strong\u003e (CM-200) - Easy to use, simply plug the sensor into the PCB and plug it into your PC via USB. Use our free \u003ca href=\"\/pages\/downloads\" title=\"Gaslab software\"\u003eGasLab® software\u003c\/a\u003e to measure and graph carbon dioxide or use our \u003ca href=\"https:\/\/github.com\/co2meter-org\/ExampleCode\" title=\"Source code on Github\" rel=\"noopener\" target=\"_blank\"\u003elibrary of source code on Github\u003c\/a\u003e to build your own application or for OEM batch testing\/configuration. Order sensors on this page, then \u003ca href=\"https:\/\/www.co2meter.com\/products\/gas-sensor-development-kit\" title=\"Gas Sensor Development Kit\"\u003eorder the Devkit here\u003c\/a\u003e.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan style=\"color: #286adc;\"\u003e\u003cstrong\u003eWe recommend that all first time users purchase both this sensor and the CM-200 Development Kit for fastest and easiest results.\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cdiv class=\"specifications\"\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eTarget gas:\u003c\/strong\u003e Carbon Dioxide (CO2)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating principle:\u003c\/strong\u003e Non-dispersive infrared (NDIR)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMeasurement range:\u003c\/strong\u003e 0-5,000ppm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAccuracy:\u003c\/strong\u003e ± (50ppm+3% of reading) @ 0°C ~ 50°C , 50±10%RH\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWorking Humidity:\u003c\/strong\u003e 0-95%RH (non-condensing)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStorage Temperature:\u003c\/strong\u003e -30°C ~ 70°C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStorage Humidity:\u003c\/strong\u003e 0-95%RH (non-condensing)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSampling frequency:\u003c\/strong\u003e 2s\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTime to first reading:\u003c\/strong\u003e ≤30s\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower supply:\u003c\/strong\u003e 4.5V-5.5 VDC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSupply current: \u003c\/strong\u003e\u0026lt;50mA\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCommunication Interfaces:\u003c\/strong\u003e UART and I²C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLife span:\u003c\/strong\u003e \u0026gt;10 years\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eWarranty\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e90 days - See\u003ca href=\"https:\/\/www.co2meter.com\/pages\/terms-conditions\" title=\"Terms and Conditions\"\u003e CO2Meter Terms and Conditions.\u003c\/a\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"documents\"\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/AM1009_Integrated_Air_Quality_Sensor_Module_Specification-2024.pdf\"\u003e\u003cimg alt=\"Manual\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/CO2METER_PDF.png?1094\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/AM1009_Integrated_Air_Quality_Sensor_Module_Specification-2024.pdf\" title=\"CO2Meter NDIR Dual Beam CO2 Sensor Module\"\u003e\u003cstrong\u003e\u003cspan style=\"color: red;\" data-mce-style=\"color: red;\"\u003e Manual (pdf)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"accessories\"\u003e\n\u003ch3\u003eAccessories\u003c\/h3\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/www.co2meter.com\/products\/gas-sensor-development-kit\" title=\"CO2Meter Gas Sensor Development Kit\"\u003e\u003cstrong\u003eGas Sensor Development Kit\u003c\/strong\u003e (CM-200)\u003c\/a\u003e- designed to provide customers with an easy drop-in solution. Includes our free \u003ca title=\"Gaslab data logging software\" href=\"https:\/\/www.co2meter.com\/pages\/downloads\"\u003eGaslab data logging software\u003c\/a\u003e. Sensor sold separately.\u003c\/p\u003e\n\u003c\/div\u003e","brand":"CO2 Meter","offers":[{"title":"Default Title","offer_id":42981412765894,"sku":"CM1109","price":50.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/CM1109DualIRSourceNDIRCO2SensorlCO2Meter.jpg?v=1753283976"},{"product_id":"gas-sensor-development-kit","title":"Gas Sensor Development Kit","description":"\u003cp\u003eThe \u003cstrong\u003e\u003cspan style=\"color: #115e67;\"\u003eCM-200 Gas Sensor Development Kit\u003c\/span\u003e\u003c\/strong\u003e is a PCB developed to help customers, students, researchers, OEMs and hobbyists go from concept to product as quickly as possible. This PCB can interface with our free \u003ca title=\"Free Gaslab Data Logging Software\" href=\"\/pages\/downloads\"\u003eGasLab® Data logging software\u003c\/a\u003e or any terminal application to evaluate sensors and view the communication protocols.\u003c\/p\u003e\n\u003cp style=\"text-align: center;\"\u003e\u003cspan style=\"color: rgb(43, 0, 255);\"\u003e\u003ca style=\"color: rgb(43, 0, 255);\" href=\"https:\/\/github.com\/co2meter-org\/ExampleCode\" title=\"CM-200 Gas Sensor Development Kit Protocol\"\u003e\u003cstrong\u003eLooking for a full repository with production ready code? View CM-200 operation, example code and more, \u0026gt;\u0026gt; click here \u0026lt;\u0026lt;\u003c\/strong\u003e\u003c\/a\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp style=\"text-align: center;\"\u003e\u003cem\u003e\u003cspan style=\"color: rgb(0, 0, 0);\"\u003e\u003cspan dir=\"ltr\" class=\"ui-provider a b c d e f g h i j k l m n o p q r s t u v w x y z ab ac ae af ag ah ai aj ak\"\u003e*Please note: Prior to purchasing please make sure to check the specifications to see all compatible sensors as shown below in the \"works with these sensors\" list*\u003c\/span\u003e\u003c\/span\u003e\u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003eUse the CM-200 as an Arduino Shield with the example code provided in this repository can rapidly get a prototype running for interfacing our most popular sensors with Arduino Uno and Arduino Mega. or use the CM-200 as a Raspberry Pi Hat to prototype using the Raspberry Pi ecosystem.\u003c\/p\u003e\n\u003cp\u003eFinally, users can develop production ready code with the onboard STM32WB55, with available BLE, USB, User LEDs, User Buttons, and multiple communication protocols.is designed to make it easy to use our most popular gas sensors.\u003c\/p\u003e\n\u003cp\u003eFor quick, real-time data analysis use the \u003ca title=\"Free Gaslab Data Logging Software\" href=\"\/pages\/downloads\"\u003eGasLab® Data logging software\u003c\/a\u003e. Plug in a sensor, plug the PCB into a PC's USB port, and begin to graph and store data as industry standard .csv files in minutes for project analysis, trends and reporting.\u003c\/p\u003e\n\u003cp\u003eWhether you are evaluating production code, building prototypes, doing data analysis or are in need of a full software development platform, the CM-200 is the right technology for you.\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003ePlease note: To ensure safety and proper operation, please observe precaution regarding electrical components on the CM-200 near other metal materials. \u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/co2meter.club\/3TlaPyf\" title=\"A CO2Meter Video on How-To Connect a Gas Sensor to the CM-200\"\u003e\u003cem\u003eHere's a CO2Meter Video on How-To Connect a Gas Sensor to the CM-200\u003c\/em\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003ch2\u003eFeatures\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e“Plug and Play” sensor compatibility\u003c\/li\u003e\n\u003cli\u003eCross-platform operating systems\u003c\/li\u003e\n\u003cli\u003eOpen source and extensible software\u003c\/li\u003e\n\u003cli\u003eSimple, clear programming environment\u003c\/li\u003e\n\u003cli\u003eData logging\u003c\/li\u003e\n\u003cli\u003eUltra-low power\u003c\/li\u003e\n\u003cli\u003eArduino Uno Shield Capable\u003c\/li\u003e\n\u003cli\u003eRaspberry Pi Hat Capable\u003c\/li\u003e\n\u003cli\u003eProgrammable STM32WB\u003c\/li\u003e\n\u003cli\u003eGit Repository with Full Working Code\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv class=\"specifications\"\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eTarget Gases:\u003c\/strong\u003e CO2 or Oxygen\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSensors Used:\u003c\/strong\u003e Varies. See list below.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInputs\/Outputs: \u003c\/strong\u003eUSB, Arduino, Raspberry Pi\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInterface:\u003c\/strong\u003e USB, BLE, Serial\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnectors:\u003c\/strong\u003e USB Type-C with 0.10 Male Header Pins\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDimensions:\u003c\/strong\u003e 2.25\" x 2.75\"\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e 0.1 lbs.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eWorks with these Sensors:\u003c\/h3\u003e\n\u003ch4\u003eSenseair K-Series CO2 Sensors\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"\/products\/k-30-co2-sensor-module\"\u003e030-8-0006 K30 10,000 ppm CO2 Sensor\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/products\/k-30-co2-sensor\"\u003e030-7-0007 K30 10% CO2 Sensor\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/products\/030-8-0011-k30-extended-range\"\u003e030-8-0011 K30 Extended Range\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/products\/030-8-0016-k30-1-co2-sensor\"\u003e030-8-0016 K30 1% CO2 Sensor\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/products\/k-30-fr-co2-sensor\"\u003e030-8-0010 K30 FR Fast Response 10,000ppm CO2 Sensor\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eSenseair Sunrise CO2 Sensors\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"\/products\/senseair-sunrise-co2-sensor\"\u003e006-0-0008 HVAC CO2 Sensor\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/products\/006-0-0007-senseair-sunrise-co2-sensor\"\u003e006-0-0007 CO2 Sensor\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/products\/009-4-0001-senseair-sunlight-refrigerant-r32-sensor?variant=42820894064838\"\u003e009-4-0001 Sunlight Refrigerant R32 Sensor\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eSenseair S8 Miniature CO2 Sensors\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"\/products\/s8-miniature-co2-sensor\"\u003e004-0-0013 S8 10,000ppm CO2 Sensor\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/products\/s8-miniature-5-co2-sensor\"\u003e004-0-0071 S8 5% CO2 Sensor\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/products\/004-0-0010-senseair-s8-commercial-co2-sensor\"\u003e004-0-0010 S8 Commercial CO2 Sensor\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/products\/004-0-0017-s8-alarm-5-co2-sensor\"\u003e004-0-0017 S8 Alarm 5% CO2 Sensor\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/products\/004-0-0050-senseair-2-percent-co2-sensor\"\u003e004-0-0050 Senseair S8 2% CO2 Sensor\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eLuminOx Oxygen Sensors\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"\/products\/25-percent-oxygen-sensor\"\u003eLOX-O2 UV Flux 25% Oxygen Sensor\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/products\/uv-flux-25-oxygen-smart-flow-through-sensor\"\u003eLOX-O2-F 25% Oxygen Flow Through Sensor\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eGSS CO2 Sensors\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"\/products\/sprintir6s-5-co2-smart-sensor\"\u003eSprintIR®-6S 5% CO2 Sensor\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/products\/sprintir6s-20-co2-smart-sensor\"\u003eSprintIR®-6S 20% CO2 Sensor\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/products\/sprintir6s-100-co2-smart-sensor\"\u003eSprintIR®-6S 100% CO2 Sensor\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/products\/gss-sprintir-r-5-co2-sensor\"\u003eSprintIR®-R 5% CO2 Sensor\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/products\/sprintir-r-20-co2-sensor\"\u003eSPRINTIR®-R 20% CO2 Sensor\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/products\/copy-of-sprintir-r-100-co2-sensor\"\u003eSprintIR®-R 100% CO2 Sensor\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/products\/minir-co2-sensor\"\u003eExplorIR®-M 5% CO2 Sensor\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/products\/explorir-20-co2-smart-led-sensor\"\u003eExplorIR®-M 20% CO2 Sensor\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/products\/explorir-100-pct-co2-sensor\"\u003eExplorIR®-M 100% CO2 Sensor\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eCubic CO2 Sensors\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"\/products\/ndir-high-accuracy-co2-sensor\"\u003e*CM1106H-NS NDIR CO2 Sensor\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/products\/cm-1106sl-n-low-power-ndir-co2-sensor\"\u003e*CM1106SL-N Super Low Power NDIR CO2 Sensor\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"\/products\/cm1109-dual-ir-source-ndir-co2-sensor\"\u003e*CM1109 Dual IR Source NDIR CO2 Sensor\u003c\/a\u003e\u003ca href=\"\/products\/ndir-high-accuracy-co2-sensor\"\u003e\u003c\/a\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eIf marked with a * request no pins. May need to purchase longer pin headers.\u003c\/p\u003e\n\u003ch3\u003eWarranty\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e90 days - \u003ca title=\"CO2Meter Terms and Conditions\" href=\"\/pages\/terms-conditions\"\u003eSee CO2Meter Terms and Conditions\u003c\/a\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"documents\"\u003e\n\u003ch2\u003eDocuments\u003c\/h2\u003e\n\u003cp\u003e\u003ca title=\"CM-200 Datasheet\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/Data_Sheet_CM-200_Gas_Sensor_Development_Kit-20.pdf?v=1770921795\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/CO2METER_PDF.png?1094\"\u003e\u003cstrong\u003e\u003cspan style=\"color: red;\"\u003e Datasheet (pdf)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/CM200_Quick_Start_Guide_-_CO2Meter.pdf?v=1720019146\" title=\"CM-200 Quick Start Guide\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/CO2METER_PDF.png?1094\"\u003e\u003c\/a\u003e\u003ca title=\"CM-200 Quick Start Guide\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/CM200_Quick_Start_Guide_-_CO2Meter.pdf?v=1721918109\"\u003e\u003cstrong\u003e\u003cspan style=\"color: red;\"\u003e CM-200 Quick Start Guide (pdf)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/AN145-sensor-development-kit-quick-start-guide.pdf?v=1650749355\" title=\"quick start guide\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/CO2METER_PDF.png?1094\"\u003e\u003cstrong\u003e\u003cspan style=\"color: red;\"\u003e Gaslab Quick Start Guide (pdf)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/github.com\/co2meter-org\/ExampleCode\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/assets\/zip.gif\" alt=\"Quick Start Guide\"\u003e\u003c\/a\u003e\u003ca rel=\"noopener\" title=\"Github code\" href=\"https:\/\/github.com\/co2meter-org\/ExampleCode\" target=\"_blank\"\u003e\u003cstrong\u003e\u003cspan style=\"color: red;\"\u003e GitHub Example Code\u003c\/span\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"accessories\"\u003e\n\u003ch3\u003eAccessories\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003ca href=\"\/products\/sensor-flow-through-director\" title=\"CO2Meter Sensor Tube Cap Adapter\"\u003eTube Cap Adapter\u003c\/a\u003e changes the sensor from reading CO2 in the air to a sample draw sensor. Use with a pump, tubing and filters to read CO2 levels in enclosed containers\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"\/products\/gas-sensor-micro-pump\"\u003eSample Draw Pump Kit\u003c\/a\u003e includes all the components you need with a sample draw sensor.\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/www.co2meter.com\/products\/co2meter-sensor-tube-cap?variant=30298906230902\" title=\"Sensor Tube Cap Adapter for 20mm Sensors\"\u003eSensor Tube Cap Adapter for 20mm Sensors\u003c\/a\u003e \u003cmeta charset=\"utf-8\"\u003e \u003cspan\u003eeasily converts a wide range of gas sensors from diffusion applications to sampling. \u003c\/span\u003e\u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e","brand":"CO2 Meter","offers":[{"title":"Gas Sensor Development Kit","offer_id":45069770326214,"sku":"CM-200","price":252.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/CM-200_Universal_Development_Kit_l_NoSensor_l_CO2Meter.jpg?v=1753283961"},{"product_id":"digital-gas-sensor-gaslab-fixed-detector","title":"Digital Gas Sensors for Gaslab Fixed Multi Gas Detector","description":"\u003cp\u003eThe\u003cstrong\u003e \u003c\/strong\u003e\u003cb\u003eDigital Gas Sensors for the Gaslab Fixed Multi Gas Detector\u003c\/b\u003e are designed to measure combustible, toxic, and oxygen gases as well as refrigerants.\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"color: rgb(43, 0, 255);\"\u003e\u003cstrong\u003eThese digital sensors are only to be operated in conjunction with the Gaslab Fixed Multi-Gas Detector series.\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eThese sensors are also \u003cstrong\u003enot\u003c\/strong\u003e to be used in potentially explosive atmospheres and must be employed in areas within environmental conditions as specified in the attached manual.\u003c\/p\u003e\n\u003cp\u003eIn addition, these gas sensors vary by operation dependent upon which gas is being measured and are used commonly for personal protection in hazardous gas environments to ensure safety and protect against exceeded gas safety thresholds during industrial processes.\u003c\/p\u003e\n\u003cp style=\"text-align: center;\"\u003e\u003cstrong\u003eLooking for a particular gas type or concentration range that is not shown? We offer over 128 gas sensor capabilities, \u003ca title=\"Contact a CO2Meter Expert Today\" href=\"https:\/\/www.co2meter.com\/pages\/contact\"\u003eplease contact us to learn more\u003c\/a\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch2\u003eFeatures\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eAccurate, High Quality Sensor Technologies\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eEasily Integrated into Gaslab Fixed Multi Gas Detectors\u003c\/li\u003e\n\u003cli\u003eLow Cross-Sensitivity across multiple gases\u003c\/li\u003e\n\u003cli\u003eEasy to use, Low Maintenance\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eProven and trusted design - 90 day warranty\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv class=\"specifications\"\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eGas Type: \u003c\/strong\u003eVaries by sensor\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMeasurement Range: \u003c\/strong\u003e\u003cstrong\u003e\u003c\/strong\u003eVaries by sensor\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHousing: \u003c\/strong\u003eStainless Steel, Plastic\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaterial: \u003c\/strong\u003ePolycarbonate, CrNi Steel: 1.4404\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eAccuracy:\u003c\/b\u003e 5 ± % sig.\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eDisplay Resolution: \u003c\/b\u003e0.1ppm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRepeatability: \u003c\/strong\u003e10 \u0026lt;± % sig.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003et90 Time: \u003c\/strong\u003e120 ≤ sec.\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eZero-point variation: \u003c\/strong\u003e5 ± ppm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTemperature Range: \u003c\/strong\u003e-22 \/ 122 °F (30 \/ +50 °C)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHumidity Range: \u003c\/strong\u003e15-90 %RH\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHousing Color: \u003c\/strong\u003e Similar to RAL 7035 (light grey), Natural\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProtection Class: \u003c\/strong\u003eIP65, IP64\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting: \u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003eScrew mounting, external thread M25 x 1.5 mmv\u003c\/li\u003e\n\u003cli\u003eScrew mounting, NPT ¾“ ANSI\/ B1.20.1 \/ M30 x 1,5 mm\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Supply: \u003c\/strong\u003e5 VDC from Board, e.g. SB2\/MSB2, reverse polarity protected\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Consumption: \u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCatalytic (Pellistor):\u003c\/strong\u003e 200 mA, max. (1.0 VA)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eElectrochemical:\u003c\/strong\u003e 10 mA, max. (0.05 VA)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSemiconductor:\u003c\/strong\u003e 160 mA, max. (0.8 VA)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInfrared Premium:\u003c\/strong\u003e 60 mA, max. (0.3 VA)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInfrared:\u003c\/strong\u003e 50 mA, max. (0.25 VA)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMPS\u003c\/strong\u003e: 25 mA, max. (0.13 VA)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection Type: \u003c\/strong\u003e3-pin connector\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCable Length:\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003eStandard: Ca. 150 mm (5.91 in.) Cable extension (5, 10 or 15 m)\u003c\/li\u003e\n\u003cli\u003eCable extension (5, 10 or 15 m)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDimensions: \u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eType P: \u003c\/strong\u003e0.94 x 0.87 in. (24 x 22 mm)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eType L: \u003c\/strong\u003e0.94 x 1.18 in. (24 x 30 mm)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eType S: \u003c\/strong\u003e1.18 x 2.40 in. (30 x 61 mm)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight: \u003c\/strong\u003e0.07 lb. (Ca. 30 g), 0.35 lb. (Ca. 150 g)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eREGULATIONS\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eEMC Directives 2014\/30\/EU\u003c\/li\u003e\n\u003cli\u003eCE\u003c\/li\u003e\n\u003cli\u003eUKCA\u003c\/li\u003e\n\u003cli\u003eEN 378\u003c\/li\u003e\n\u003cli\u003eEN 14624\u003c\/li\u003e\n\u003cli\u003eEN 45544-1, -3\u003c\/li\u003e\n\u003cli\u003eEN 50104 (for O2)\u003c\/li\u003e\n\u003cli\u003eEN 50271\u003c\/li\u003e\n\u003cli\u003eEN 50545-1\u003c\/li\u003e\n\u003cli\u003eEN 61508-1–3\u003c\/li\u003e\n\u003cli\u003eEN 61010-1:2010\u003c\/li\u003e\n\u003cli\u003eANSI\/UL 61010-1\u003c\/li\u003e\n\u003cli\u003eCAN\/CSA-C22.2 No. 61010-1\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003ch3\u003eWarranty\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e90 Days - See \u003ca title=\"CO2Meter Terms and Conditions\" href=\"https:\/\/www.co2meter.com\/pages\/terms-conditions\"\u003eCO2Meter Terms and Conditions.\u003c\/a\u003e (if not poisoned or overloaded)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"documents\"\u003e\n\u003ch3\u003eDocuments\u003c\/h3\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/DS-SC2-E1110-A-P-00-Carbon_Monoxide_CO_digital_sensor_for_gaslab_fixed_multi-gas_detector-CO2Meter.pdf?v=1724861195\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/CO2METER_PDF.png?1093\" alt=\"Datasheet\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/DS-SC2-E1110-A-P-00-Carbon_Monoxide_CO_digital_sensor_for_gaslab_fixed_multi-gas_detector-CO2Meter.pdf?v=1724861195\" title=\"Datasheet\"\u003e\u003cstrong\u003e \u003cspan style=\"color: red;\"\u003eData Sheet - CO Digital Sensor (pdf)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/DS-SC2-E1125-A-P-00-Ammonia_NH3_digital_sensor_for_gaslab_fixed_multi-gas_detector-CO2Meter.pdf?v=1724861341\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/CO2METER_PDF.png?1093\" alt=\"Datasheet\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/DS-SC2-E1125-A-P-00-Ammonia_NH3_digital_sensor_for_gaslab_fixed_multi-gas_detector-CO2Meter.pdf?v=1724861341\" title=\"Datasheet\"\u003e\u003cstrong\u003e\u003cspan style=\"color: red;\"\u003e Data Sheet - NH3 Digital Sensor (pdf)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/DS-SC2-E1130-B-P-00-Nitrogen_Dioxide_NO2_digital_sensor_for_gaslab_fixed_multi-gas_detector-CO2Meter.pdf?v=1724861418\"\u003e \u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/CO2METER_PDF.png?1093\" alt=\"Datasheet\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/DS-SC2-E1130-B-P-00-Nitrogen_Dioxide_NO2_digital_sensor_for_gaslab_fixed_multi-gas_detector-CO2Meter.pdf?v=1724861418\" title=\"Datasheet\"\u003e \u003cstrong\u003e\u003cspan style=\"color: red;\"\u003e Data Sheet - NO2 Digital Sensor (pdf)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/DS-SC2-E1194-A-P-00-Hydrogen_H2_digital_sensor_for_gaslab_fixed_multi-gas_detector-CO2Meter.pdf?v=1724861489\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/CO2METER_PDF.png?1093\" alt=\"Datasheet\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/DS-SC2-E1194-A-P-00-Hydrogen_H2_digital_sensor_for_gaslab_fixed_multi-gas_detector-CO2Meter.pdf?v=1724861489\" title=\"Datasheet\"\u003e\u003cstrong\u003e\u003cspan style=\"color: red;\"\u003e Data Sheet - H2 Digital Sensor (pdf)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/DS-SC2-E1195-A2-P-00-oxygen_o2_digital_sensor_for_gaslab_fixed_multi-gas_detector-CO2Meter.pdf?v=1724861600\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/CO2METER_PDF.png?1093\" alt=\"Datasheet\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/DS-SC2-E1195-A2-P-00-oxygen_o2_digital_sensor_for_gaslab_fixed_multi-gas_detector-CO2Meter.pdf?v=1724861600\" title=\"Datasheet\"\u003e \u003cstrong\u003e\u003cspan style=\"color: red;\"\u003e Data Sheet - O2 Digital Sensor (pdf)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/DS-SC2-I464-B-P-00-carbon_dioxide_co2_digital_sensor_for_gaslab_fixed_multi-gas_detector-CO2Meter.pdf?v=1724861777\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/CO2METER_PDF.png?1093\" alt=\"Datasheet\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/DS-SC2-I464-B-P-00-carbon_dioxide_co2_digital_sensor_for_gaslab_fixed_multi-gas_detector-CO2Meter.pdf?v=1724861777\" title=\"DataSheet\"\u003e\u003cstrong\u003e\u003cspan style=\"color: red;\"\u003e Data Sheet - CO2 Digital Sensor (pdf)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/GA_MC2_SC2_CO2Meter_E.pdf?v=1718288619\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/CO2METER_PDF.png?1093\" alt=\"Manual\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/GA_MC2_SC2_CO2Meter_E.pdf?v=1718288619\" title=\"Manual\"\u003e\u003cstrong\u003e\u003cspan style=\"color: red;\"\u003e Manual - Digital Sensor Portfolio (pdf)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e","brand":"CO2Meter","offers":[{"title":"SC2-E1110-A-P-00: CO Digital Sensor for Gaslab Fixed Gas Detector (0-50ppm CO)","offer_id":43731100696774,"sku":"SC2-E1110-A-P-00","price":410.0,"currency_code":"USD","in_stock":true},{"title":"SC2-E1125-A-P-00: NH3 Digital Sensor for Gaslab Fixed Gas Detector (0-100ppm NH3)","offer_id":43781059576006,"sku":"SC2-E1125-A-P-00","price":610.0,"currency_code":"USD","in_stock":true},{"title":"SC2-E1130-B-P-00: NO2 Digital Sensor for Gaslab Fixed Gas Detector (0-20ppm NO2)","offer_id":43781059903686,"sku":"SC2-E1130-B-P-00","price":454.0,"currency_code":"USD","in_stock":true},{"title":"SC2-E1194-A-P-00: H2 Digital Sensor for Gaslab Fixed Gas Detector (0-1000ppm H2)","offer_id":43781060231366,"sku":"SC2-E1194-A-P-00","price":585.0,"currency_code":"USD","in_stock":true},{"title":"SC2-E1195-A2-P-00: O2 Digital Sensor for Gaslab Fixed Gas Detector (0-25% O2)","offer_id":43781060526278,"sku":"SC2-E1195-A2-P-00","price":320.0,"currency_code":"USD","in_stock":true},{"title":"SC2-I464-B-P-00: CO2 Digital Sensor for Gaslab Fixed Gas Detector (0-5% CO2)","offer_id":43781060821190,"sku":"SC2-I464-B-P-00","price":1015.0,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/SC2-E1110-A-P-00_800x800_75b4c4d5-5ff3-4217-ad31-e3be510e403a.jpg?v=1753283950"},{"product_id":"fixed-multi-gas-detector-sensor","title":"Analog Gas Sensors for Gaslab Fixed Multi Gas Detector","description":"\u003cp\u003eThe \u003cstrong\u003eAnalog\u003c\/strong\u003e\u003cb\u003e Gas Sensors for the Gaslab Fixed Multi Gas Detector\u003c\/b\u003e are designed to measure combustible, toxic, and oxygen gases as well as refrigerants.\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"color: rgb(0, 0, 0);\"\u003e\u003cstrong\u003e*Please note: these analog sensors are only to be operated in conjunction with the Gaslab Fixed Multi-Gas Detector series.\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eThese sensors are also \u003cstrong\u003enot\u003c\/strong\u003e to be used in potentially explosive atmospheres and must be employed in areas within environmental conditions as specified in the attached manual.\u003c\/p\u003e\n\u003cp\u003eIn addition, these gas sensors vary by operation dependent upon which gas is being measured and are used commonly for personal protection in hazardous gas environments to ensure safety and protect against exceeded gas safety thresholds during industrial processes.\u003c\/p\u003e\n\u003cp style=\"text-align: center;\"\u003e\u003cstrong\u003eLooking for a particular gas type or concentration range that is not shown? We offer over 128 gas sensor capabilities, \u003ca href=\"https:\/\/www.co2meter.com\/pages\/contact\" title=\"Contact a CO2Meter Expert Today\"\u003eplease contact us to learn more.\u003c\/a\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch2\u003eFeatures\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eAccurate, High Quality Sensor Technologies\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eEasily Integrated into Gaslab Fixed Multi Gas Detectors\u003c\/li\u003e\n\u003cli\u003eLow Cross-Sensitivity across multiple gases\u003c\/li\u003e\n\u003cli\u003eEasy to use, Low Maintenance\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eProven and trusted design - 90 day warranty\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv class=\"specifications\"\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eGas Type: \u003c\/strong\u003eVaries by Sensor Selection\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMeasurement Range: \u003c\/strong\u003e\u003cstrong\u003e\u003c\/strong\u003eVaries by Sensor Selection\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHousing: \u003c\/strong\u003ePlastic, Stainless Steel\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaterial\u003c\/strong\u003e: Polycarbonate, CrNi steel: 1.4404\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFlammability Classification: \u003c\/strong\u003eUL 94 V2\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStorage Temperature Range: \u003c\/strong\u003e0 °C to +20 °C (32 °F to 68 °F)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStorage Time: \u003c\/strong\u003eCa. 6 months\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHumidity Range: \u003c\/strong\u003e0–95 % RH non-condensing\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePressure Range:\u003c\/strong\u003e 90–110 kPa\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHousing Color: \u003c\/strong\u003e Similar to RAL 7035 (light grey), Natural\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProtection Class: \u003c\/strong\u003eIP65, IP64\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting: \u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003eScrew mounting, external thread M25 x 1.5 mmv\u003c\/li\u003e\n\u003cli\u003eScrew mounting, NPT ¾“ ANSI\/ B1.20.1 \/ M30 x 1,5 mm\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Supply: \u003c\/strong\u003e5 VDC from Board, e.g. SB2\/MSB2, reverse polarity protected\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Consumption: \u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCatalytic (Pellistor):\u003c\/strong\u003e 200 mA, max. (1.0 VA)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eElectrochemical:\u003c\/strong\u003e 10 mA, max. (0.05 VA)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSemiconductor:\u003c\/strong\u003e 160 mA, max. (0.8 VA)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInfrared Premium:\u003c\/strong\u003e 60 mA, max. (0.3 VA)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInfrared:\u003c\/strong\u003e 50 mA, max. (0.25 VA)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMPS\u003c\/strong\u003e: 25 mA, max. (0.13 VA)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eSerial interface local bus: \u003c\/b\u003e1-wire \/ 19200 Baud\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection Type: \u003c\/strong\u003e3-pin connector\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCable Length:\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003eStandard: Ca. 150 mm (5.91 in.) Cable extension (5, 10 or 15 m)\u003c\/li\u003e\n\u003cli\u003eCable extension (5, 10 or 15 m)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDimensions: \u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eType P: \u003c\/strong\u003e0.94 x 0.87 in. (24 x 22 mm)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eType L: \u003c\/strong\u003e0.94 x 1.18 in. (24 x 30 mm)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eType S: \u003c\/strong\u003e1.18 x 2.40 in. (30 x 61 mm)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight: \u003c\/strong\u003e0.07 lb. (Ca. 30 g), 0.35 lb. (Ca. 150 g)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cstrong\u003eCROSS SENSITIVITY\u003c\/strong\u003e\u003cbr\u003e\n\u003cul\u003e\n\u003cli\u003eH2S sensitivity % measured gas@ 20ppm H2S  \u0026lt; \u003cb data-mce-fragment=\"1\"\u003e±\u003c\/b\u003e3\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eH2 sensitivity % measured gas@ 400ppm H2@ 20°C \u0026lt; 15\u003c\/li\u003e\n\u003cli\u003eNO2 sensitivity % measured gas@ 20ppm NO2 \u0026lt; -60\u003c\/li\u003e\n\u003cli\u003eCl2 sensitivity % measured gas@ 10ppm Cl2 \u0026lt; -300\u003c\/li\u003e\n\u003cli\u003eNO sensitivity % measured gas@ 50ppm NO \u0026lt; 20\u003c\/li\u003e\n\u003cli\u003eSO2 sensitivity % measured gas@ 20ppm SO2 nd\u003c\/li\u003e\n\u003cli\u003eC2H4 sensitivity % measured gas@ 400ppm C2H4 \u0026lt;2\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eREGULATIONS\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eEMC Directives 2014\/30\/EU\u003c\/li\u003e\n\u003cli\u003eCE\u003c\/li\u003e\n\u003cli\u003eUKCA\u003c\/li\u003e\n\u003cli\u003eEN 378\u003c\/li\u003e\n\u003cli\u003eEN 14624\u003c\/li\u003e\n\u003cli\u003eEN 45544-1, -3\u003c\/li\u003e\n\u003cli\u003eEN 50104 (for O2)\u003c\/li\u003e\n\u003cli\u003eEN 50271\u003c\/li\u003e\n\u003cli\u003eEN 50545-1\u003c\/li\u003e\n\u003cli\u003eEN 61508-1–3\u003c\/li\u003e\n\u003cli\u003eEN 61010-1:2010\u003c\/li\u003e\n\u003cli\u003eANSI\/UL 61010-1\u003c\/li\u003e\n\u003cli\u003eCAN\/CSA-C22.2 No. 61010-1\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003ch3\u003eWarranty\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e90 Days - See \u003ca href=\"https:\/\/www.co2meter.com\/pages\/terms-conditions\" title=\"CO2Meter Terms and Conditions\" data-mce-href=\"https:\/\/www.co2meter.com\/pages\/terms-conditions\"\u003eCO2Meter Terms and Conditions.\u003c\/a\u003e \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"documents\"\u003e\n\u003ch3\u003eDocuments\u003c\/h3\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/DS-MC2-0-E1110-A-0-P-_CO_Analog_Sensor_for_Gaslab_Fixed_Multi_Gas_Detector_0-50ppm_CO_-co2meter.pdf?v=1721825878\" data-mce-href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/DS-MC2-0-E1110-A-0-P-_CO_Analog_Sensor_for_Gaslab_Fixed_Multi_Gas_Detector_0-50ppm_CO_-co2meter.pdf?v=1721825878\"\u003e\u003cimg alt=\"Datasheet\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/CO2METER_PDF.png?1093\" data-mce-src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/CO2METER_PDF.png?1093\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/DS-MC2-0-E1110-A-0-P-_CO_Analog_Sensor_for_Gaslab_Fixed_Multi_Gas_Detector_0-50ppm_CO_-co2meter.pdf?v=1721825878\" title=\"Datasheet for Analog CO Sensor\" data-mce-href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/DS-MC2-0-E1110-A-0-P-_CO_Analog_Sensor_for_Gaslab_Fixed_Multi_Gas_Detector_0-50ppm_CO_-co2meter.pdf?v=1721825878\"\u003e\u003cstrong\u003e\u003cspan style=\"color: red;\" data-mce-style=\"color: red;\"\u003e Data Sheet - CO Analog Sensor (pdf)\u003c\/span\u003e \u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/DS-MC2-0-E1125-A-0-P-_NH3_Analog_Sensor_for_Gas_lab_Fixed_Multi-Gas_Detector_0-100ppm_NH3_-co2meter.pdf?v=1721825889\" data-mce-href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/DS-MC2-0-E1125-A-0-P-_NH3_Analog_Sensor_for_Gas_lab_Fixed_Multi-Gas_Detector_0-100ppm_NH3_-co2meter.pdf?v=1721825889\"\u003e\u003cimg alt=\"Datasheet\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/CO2METER_PDF.png?1093\" data-mce-src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/CO2METER_PDF.png?1093\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/DS-MC2-0-E1125-A-0-P-_NH3_Analog_Sensor_for_Gas_lab_Fixed_Multi-Gas_Detector_0-100ppm_NH3_-co2meter.pdf?v=1721825889\" title=\"Datasheet NH3 Analog Gas Sensor\" data-mce-href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/DS-MC2-0-E1125-A-0-P-_NH3_Analog_Sensor_for_Gas_lab_Fixed_Multi-Gas_Detector_0-100ppm_NH3_-co2meter.pdf?v=1721825889\"\u003e\u003cstrong\u003e\u003cspan style=\"color: red;\" data-mce-style=\"color: red;\"\u003e Data Sheet - NH3 Analog Sensor (pdf)\u003c\/span\u003e \u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/DS-MC2-0-E1130-B-0-P-_NO2_Analog_Sensor_for_Gas_lab_Fixed_Multi-Gas_Detector_0-20ppm_NO2.pdf?v=1721825898\" data-mce-href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/DS-MC2-0-E1130-B-0-P-_NO2_Analog_Sensor_for_Gas_lab_Fixed_Multi-Gas_Detector_0-20ppm_NO2.pdf?v=1721825898\"\u003e\u003cimg alt=\"Datasheet\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/CO2METER_PDF.png?1093\" data-mce-src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/CO2METER_PDF.png?1093\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/DS-MC2-0-E1130-B-0-P-_NO2_Analog_Sensor_for_Gas_lab_Fixed_Multi-Gas_Detector_0-20ppm_NO2.pdf?v=1721825898\" title=\"Datasheet NO2 Analog Gas Sensor\" data-mce-href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/DS-MC2-0-E1130-B-0-P-_NO2_Analog_Sensor_for_Gas_lab_Fixed_Multi-Gas_Detector_0-20ppm_NO2.pdf?v=1721825898\"\u003e\u003cstrong\u003e\u003cspan style=\"color: red;\" data-mce-style=\"color: red;\"\u003e Data Sheet - NO2 Analog Sensor (pdf)\u003c\/span\u003e \u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/DS-MC2-0-E1194-A-0-P-_H2_Analog_Sensor_for_Gas_lab_Fixed_Multi-Gas_Detector_0-1000ppm_H2.pdf?v=1721825921\" data-mce-href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/DS-MC2-0-E1194-A-0-P-_H2_Analog_Sensor_for_Gas_lab_Fixed_Multi-Gas_Detector_0-1000ppm_H2.pdf?v=1721825921\"\u003e\u003cimg alt=\"Datasheet\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/CO2METER_PDF.png?1093\" data-mce-src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/CO2METER_PDF.png?1093\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/DS-MC2-0-E1194-A-0-P-_H2_Analog_Sensor_for_Gas_lab_Fixed_Multi-Gas_Detector_0-1000ppm_H2.pdf?v=1721825921\" title=\"Datasheet H2 Analog Gas Sensor\" data-mce-href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/DS-MC2-0-E1194-A-0-P-_H2_Analog_Sensor_for_Gas_lab_Fixed_Multi-Gas_Detector_0-1000ppm_H2.pdf?v=1721825921\"\u003e\u003cstrong\u003e\u003cspan style=\"color: red;\" data-mce-style=\"color: red;\"\u003e Data Sheet - H2 Analog Sensor (pdf)\u003c\/span\u003e \u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/DS-MC2-0-E1195-A5-0-P-_O2_Analog_Sensor_for_Gas_lab_Fixed_Multi-Gas_Detector_0-25_O2.pdf?v=1721825939\" data-mce-href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/DS-MC2-0-E1195-A5-0-P-_O2_Analog_Sensor_for_Gas_lab_Fixed_Multi-Gas_Detector_0-25_O2.pdf?v=1721825939\"\u003e\u003cimg alt=\"Datasheet\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/CO2METER_PDF.png?1093\" data-mce-src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/CO2METER_PDF.png?1093\"\u003e\u003c\/a\u003e\u003cstrong\u003e\u003ca title=\"Datasheet O2 Analog Gas Sensor\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/DS-MC2-0-E1195-A5-0-P-_O2_Analog_Sensor_for_Gas_lab_Fixed_Multi-Gas_Detector_0-25_O2.pdf?v=1723211165\"\u003e\u003cspan style=\"color: red;\" data-mce-style=\"color: red;\"\u003e Data Sheet - O2 Analog Sensor (pdf)\u003c\/span\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/DS-MC2-0-E1195-A5-0-P-_O2_Analog_Sensor_for_Gas_lab_Fixed_Multi-Gas_Detector_0-25_O2.pdf?v=1721825939\" title=\"Datasheet O2 Analog Gas Sensor\" data-mce-href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/DS-MC2-0-E1195-A5-0-P-_O2_Analog_Sensor_for_Gas_lab_Fixed_Multi-Gas_Detector_0-25_O2.pdf?v=1721825939\"\u003e \u003c\/a\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/DS-MC2-0-I464-B-0-P-_CO2_Analog_Sensor_for_Gas_lab_Fixed_Multi-Gas_Detector_0-5_CO2.pdf?v=1721826008\" data-mce-href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/DS-MC2-0-I464-B-0-P-_CO2_Analog_Sensor_for_Gas_lab_Fixed_Multi-Gas_Detector_0-5_CO2.pdf?v=1721826008\"\u003e\u003cimg alt=\"Datasheet\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/CO2METER_PDF.png?1093\" data-mce-src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/CO2METER_PDF.png?1093\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/DS-MC2-0-I464-B-0-P-_CO2_Analog_Sensor_for_Gas_lab_Fixed_Multi-Gas_Detector_0-5_CO2.pdf?v=1721826008\" title=\"Datasheet for CO2 Analog Gas Sensor\" data-mce-href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/DS-MC2-0-I464-B-0-P-_CO2_Analog_Sensor_for_Gas_lab_Fixed_Multi-Gas_Detector_0-5_CO2.pdf?v=1721826008\"\u003e\u003cstrong\u003e\u003cspan style=\"color: red;\" data-mce-style=\"color: red;\"\u003e Data Sheet - CO2 Analog Sensor (pdf)\u003c\/span\u003e \u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/GA_MC2_SC2_CO2Meter_E.pdf?v=1718288619\" data-mce-href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/GA_MC2_SC2_CO2Meter_E.pdf?v=1718288619\"\u003e\u003cimg alt=\"Manual\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/CO2METER_PDF.png?1093\" data-mce-src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/CO2METER_PDF.png?1093\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/GA_MC2_SC2_CO2Meter_E.pdf?v=1718288619\" title=\"Manual for Digital Gas Sensor Portfolio\" data-mce-href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/GA_MC2_SC2_CO2Meter_E.pdf?v=1718288619\"\u003e\u003cstrong\u003e\u003cspan style=\"color: red;\" data-mce-style=\"color: red;\"\u003eManual - Analog Sensor Portfolio (pdf)\u003c\/span\u003e \u003c\/strong\u003e\u003c\/a\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cstrong\u003e \u003c\/strong\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003c\/div\u003e","brand":"CO2Meter","offers":[{"title":"MC2-0-E1110-A-0-P: CO Analog Sensor for Gaslab Fixed Gas Detector (0-50ppm CO)","offer_id":43849926607046,"sku":"MC2-0-E1110-A-0-P","price":495.0,"currency_code":"USD","in_stock":true},{"title":"MC2-0-E1125-A-0-P: NH3 Analog Sensor for Gaslab Fixed Gas Detector (0-100ppm NH3)","offer_id":43849926639814,"sku":"MC2-0-E1125-A-0-P","price":689.0,"currency_code":"USD","in_stock":true},{"title":"MC2-0-E1130-B-0-P: NO2 Analog Sensor for Gaslab Fixed Gas Detector (0-20ppm NO2)","offer_id":43849926672582,"sku":"MC2-0-E1130-B-0-P","price":540.0,"currency_code":"USD","in_stock":true},{"title":"MC2-0-E1194-A-0-P: H2 Analog Sensor for Gaslab Fixed Gas Detector (0-1000ppm H2)","offer_id":43849926705350,"sku":"MC2-0-E1194-A-0-P","price":675.0,"currency_code":"USD","in_stock":true},{"title":"MC2-0-E1195-A2-0-P: O2 Analog Sensor for Gaslab Fixed Gas Detector (0-25% O2)","offer_id":43849926738118,"sku":"MC2-0-E1195-A2-0-P","price":799.0,"currency_code":"USD","in_stock":true},{"title":"MC2-0-I464-B-0-P: CO2 Analog Sensor for Gaslab Fixed Gas Detector (0-5% CO2)","offer_id":43849926770886,"sku":"MC2-0-I464-B-0-P","price":1105.0,"currency_code":"USD","in_stock":true},{"title":"MC2-0-E1197-B-0-P: H2S Analog Sensor for Gaslab Fixed Gas Detector 0-100ppm","offer_id":44009768288454,"sku":"MC2-0-E1197-B-0-P","price":979.0,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/MC2-0-E1110-A-0-P_-_CO_Analog_Sensor_for_Gaslab.jpg?v=1753283946"}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/collections\/co2-sensors-949203.jpg?v=1674682136","url":"https:\/\/www.co2meter.com\/collections\/co2-sensors\/carbon-dioxide.oembed","provider":"CO2 Meter","version":"1.0","type":"link"}